~ %el 0
~
~ A 19
- mes -G-Sei sH.> ot= S C.AGE l(4 tF HAIJERAIL (Tvy).t.'F (ht ttt COIL CHAIIJ j
I.
TYP s
L 4 LAFtDEP POCF H
P. EL 4).&O YPtL'
'/
E <OPF HAIJD) t RE)/I Rtt(NELS sl FRA)/IE bttt AttOUT '
REM, PX(NEL k.ls4 ~44 S'-0 L3 REO'D EA LOC)
IA5TM A-533 CLASS 2 STF EL)
Ig4 HAND PAlL K (>HI5)
ROOF PAPT PLAhJ 8.EL49.50 tg= ILO
'3
~! 5GP SECT( 6 I'-I,'OP SECT H LAD
'3AP CAGE 5ATl
')
t I
t( 4 HOLES FOP zttt C T K BOLTS FOR CAGE UAFI 6 "tt, O'OLE>
FO~@0 CTSV, I3OLTS FOR LADDER Elgb CTSX HD OH IHSkE OF CAGE.
P.
LAI/0E,IY 5AP; 5t (tt7)
I I
t (tt.
Ill C
t C>
'L
'D.bd t53 4 D F t 2. STiFF ItS Stw TO DET C (L'Tt~
4 t)L'g+ WEEP WO
- i. (
3-0 I
~~OPEN()IG It4 CONC, t/ttALL F(Otttt(D 60TH 80T I'D(A E5. IttADtD5=2M [
(TYF" I
t t
I It I
le+ R.
RE.NI PAIIEC.
', ~
- CI2 i
-t. 5 "3'z I L5A3'2 t'l C I2
'I t.
2Ll 2'- 2 t
t i' '-l EI EVA7ION A tcs) i-t0,,
I
'3 Lm'A'I tt
-It(I(ND I.INi tL LtfT I UG, 2 PER EA RANEL ( 'F'>
SEE DET (te>)
I o
tt~t LOT L DE'T (
SINAI IC2) tt CIS/4'a STIFF tt UT tt(tT FLS)
SECT 8
(C~)
TT IY)
I
. -ZA 2 I3A)JD +
(TYP) 2"'2 BAR)
(TYP) t
- 4 'z I3AIJO FACE Cii COIJC WALL 'I
, PLA'TFf '3,0F, 7
- FOR PLAT F 't)ET SEE G-84I 5H,t PIJ3',.
~~(~A. TACV 3NELO-Ft DE r L(( I4)
TCtP OF(ROOF t i~,ft)
CL I
( gt(
5 "2BT 0{TYP)
(3FIZ) ~6 W2 (2'-O) HOPIS (TYP) -~I FOP PET SEE G-I323 5H I
i co 0
'l I3AIJO
'g lg
"-HOP WELD EACH tz BAR TO SA)J0.
ATTACH CAGE TO LADI'Ek WITH '2 (I
~C( HD A>07 EIOLTS WITH HE. X hlUT5 I -I<
FOR SECT G I'- 5'2 FOR SECT H SPLICE SE;E 0E'T J (3EI5)
SE.CT G (~ES) 5E.CT H (Or.e) 34= I'-O LADE)EP fMP t r 0 PUIJG TYP PUklC) DET g'@LICE 2 II'. (TYI 4 (tt EtSB FOIL CHAIN WITH SPPIIJG SIJAP RING(AT EtOTLI EIJL>>
DET J (3F~)
SFCT K (30E)
II O 2)LOTTED Hoi ES (gal" ~ I4 I %ok cAGE E/AII Et, tttt,e << l4 f FOR LADDER IMPAR
, N'OTES FOR GENERAl, NOTES SEE DWG 2998 G-807 SH.I ALL CREEL SMA'LL BE ASTNI ASCtt L)ttl.
TTP>-tg 3T. g I
. S4<~7stt, S'IL NF,LSON STOO3 SftACE 0 (tA I' 0 C tttAt(. (.TYP) to i ta ttttLttOI( 5TeADS'tt(ELO TO F(IAFtE L'.
2-0 (3.L MAtt, STA(t(t6%'ED w/TH NF LSOtt ST(t'IlffTY(t)
- CI2.) (C(t7 CNE FLC A5 Stt.t(A<<}
I I
24 CUT ALONG THt5 LINE g SEND TOOPrtt REFERENCE DRANfI N G5 LIST OF DRA3tVINGS 2998-A-Iea TURB INE BLDG COL SCHEDULE 5H. I 29tlt8.GM7 Sttl COMPONENT COOLIltIG AREA NIISSILE PROTECTION
- MA%
2 5t '38 -6."%5, CotttIPQNENT COOL(NG wATER AREA II DIESEL GENERATOR SLOG 2998-&-077SO 7 >tt It Rett, F%NEL fENO LttIE-t(NLtt:2 St'Ru /=
4 2 CLtT FROM L5~3'z~-+ (ALONG StI 00T CF Ft&s PANEL.)
T/ItTEFL WELDED tEt CORNE(LS I'z 3'2, FOR Otttt SEC PLAIJ (C$ )
FOR INFO NOT SMOttYN SEE DET C,
L It'23
- t. (Itt Ste
. CI2 K
D E 7 C
(I33,Gw,t/h9 3 = I'-O 3ml'ci SK (;7 E
Lt -,DS; 3= i(0 SEISMlC CLASS t
L LIFT l.U6-<
(FOFL t OC SEE EL)
< 2S,(.+ HOLE 2:,
IS4 6 RE)/3 PANEL.
TB'S APERmgp litt se
~
p B(L'3 lst I
I FT LU 6 DET
(,E2)(FS)
CARD THIS DOCUMENT IS THE PROPERTY Ot EBASCO SERVICES KGRPORATED ITS USE IS EXPRESSLY RES'TRtCTEO IFY THE ERMS OF THE
LIGMT COMPANY.
R.QRIGA POWER 8 LSHT CQN%NY.
ST. LUCIE PLANT IS83%90MW(e ) EXTENSION-UNIT NO.R CPIIIIIPONENT COOLING AREA F'RAIIIIING SH.3 EBASCO SERVICES INCORPORATED
'2
?,I 'le-3')
lDATE RBV CCtCt)PLAH(tlat H((tt)SEI T ADD- (Eii) LADDER 8. CAGE A.G, gvl) wl FI.S. 7 <<
CH.
'17 APPSOVED SCALE %
I'-0 Lt hl.
18 Aee 3t DATtt f T0 (O t"37"j 19 I81090&Q "