ML17207A718

From kanterella
Jump to navigation Jump to search
Requests Topical Rept Be Performed Re Rocs Coarse Mesh Neutronics Nodal Code.List of Topics to Be Explored Encl
ML17207A718
Person / Time
Site: Millstone, Calvert Cliffs, Saint Lucie, Arkansas Nuclear  
Issue date: 12/17/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Scherer A
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
References
NUDOCS 8001080027
Download: ML17207A718 (6)


Text

~p,o REoo P0 o

I I

cA

+~

~O

+**++

ig ~

'NITED'sTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 December 17, 1979 go</m>

5 Q-3/5 Nr. A. E. Scherer Licensing Manager Combustion Engineering, Inc.

1000 Prospect Hill Road Mindsor, Connecticut 06095

Dear Mr. Scherer:

Recently the coarse mesh neut'ronics nodal code ROCS has been employed in CE reload safety analyses.

To date the only information we have received on ROCS is in the form of responses to requests for additional information on reload applications plus a few short articles in the literature.

With this limited information it is difficult'for us to assess the correctness of the uses CE is putting to ROCS.

Therefore, we request that CE submit a topical report on the POCS code.

This topical report should discuss the following subjects:

1.

A theoretical development of the ROCS neutronic methodology including all neutronics equations solved by ROCS, 2.

A description of all benchmark comparisons of ROCS with other codes and with experiements.

3.

An assessment of the uncertainty in parameters computed by ROCS based on the benchmarks of (2) above.

4, A description of all ROCS calculations being performed in reload safety analyses.

5.

An estimate of the uncertainty of ROCS parameters for all safety analysis parameters of (4) above.

6.

A description and justification for the criteria used by CE to determine whether to compute reload safety parameters using PDg or ROCS.

There criteria should be stated concisely and in numberical terms.

7.

A description of possible additional future uses of ROCS in reload safety analyses.

8.

A description of all planned uses of ROCS in new plant safety analyses.

Qoox68o ~2~

If it seems more appropriate you may wish to instead discuss items 4, 5, 6

and 7 above in the reload methodology topical report which we recently re-quested from you.

Until this ROCS topical report is reviewed and approved by us, it is our position that we will not approve an increase in the scope of ROCS usage over that which has appeared in reload applications to date, Me believe that you can prepare a

ROCS topical report within a few months.

Please contact us if you have any questions concerning this matter.

Sincerely,

(~~~~~~y ll'C.C~~

Robert W. Reid, Chief Operating Reactors Branch 04 Division of Operating Reactors Office of Nuclear Reactor Regulation

Arkansas Power 8 Light Company Phillip K. Lyon, Esq.

House, Holms 8 Jewell 1550 Tower Building Little Rock, Arkansas 72201 Mr. David C. Trimble
Manager, Licensing Arkansas Power 5 Light Company P. 0.

Box 551 Little Rock, Arkansas 72203 Mr. James P. O'Hanlon General Manager Arkansas Nuclear One P.

0.

Box 608 Russellville, Arkansas 72801 Mr. William Johnson U. S. Nuclear Regulatory Commission P. 0.

Box 2090 Russellville, Arkansas 72801 Mr. Robert B. Borsum Babcock 8 Wilcox Nuclear Power Generation Division Suite 420, 7735 Old Georgetown Road

Bethesda, Maryland 20014 Troy B. Conner, Jr.,

Esq.

Conner, Moore 8 Corber 1747 Pennsylvania
Avenue, N.W.

Washington, D.C.

20006 Arkansas Polytechnic College Russellville, Arkansas 72801 Honorable Ermil Grant Acting County Judge of Pope County Pope County Courthouse Russellville, Arkansas 72801 Director, Technical Assessment Division Office of Radiation Programs (AW-459)

U. S.

Environmental Protection Agency Crystal Mall 0'2 Arlington, Virginia 20460 U. S.

Environmental Protection Agency Region VI Office ATTN:

E IS COORDINATOR 1201 Elm Street First International Building

Dallas, Texas 75270 I

Director, Bureau of Environmental Health Services 4815 West Mar kham Street Little Rock, Arkansas 72201 Mr. William Cavanaugh, III Vice President, Generation and Construction Arkansas Power 8 Light Co.

P. 0.

Box 551 Little Rock, Arkansas 72203

Baltimore Gas and Electric Company

'James A. Biddison, Jr.

General Counsel G and E Building Charles Center Baltimore, llaryland 21203 George F. Trovibridge, Esquire Shavr, Pittman, Potts and Trowbridqe 1800 H Street, tJ.W.

Washington, D.

C.

20036 Hr. R.

C. L. Olson Baltimore Gas and Electric Company Room 922 -

G and E Building Post Office Box 1475 Baltimore, Harvland 21203 Mr. Leon B. Russell, Chief Engineer Calvert Cliffs lluclear Power Plant Baltimore Gas and Electric Company Lusby, tlaryland 20657 Bechtel Power Corporation ATTN:

fir. J.

C. Judd Chief tluclear Engineer 1574U Shady Grove Road Gai ttiersbura, tlaryl and 20760 Combustion Engineering, Inc.

ATTN:

Mr. P.

W. Kruse, llanager Engineering Services Post Office Box 500 Windsor, Connecticut 06095 Calvert County L'ibrary Prince Frederick, tharyl'and 20678 Hr. Bernard Fowler President, Board of County Commissioners Prince Frederick, llaryland 20768 Director, Technical Assessment Division Office of Radiation Programs (AW-459)

U.

S.

Environmental Protection Agency Crystal Mall f/2 Arlington, Virginia 20460 U.

S. Environmental Protection Agency Region III Office ATTN:

EIS COORDINATOP, Curtis Building (Sixth Floor)

Sixth and Walnut Streets Philadelphia, Pennsylvania 19106 Administrator, Power Plant Siting Program Energy and Coastal Zone Administration Department of tlatural Resources Tawes State Office Building Annapol i s, t1aryl and 21401 Mr. A. E; Lundvall, Jr.

Vice President

- Supply Baltimore Gas 8 Electric Co.

P. 0.

Box 1475 Baltimore, Maryland 21203 Director, Department of State Planning 301 1Jest Preston Street Baltimore, Maryland 21201 Mr.

R.

M. Douglass, t1anager equality Assurance Department Room 923 Gas

8. Electric Building P.

0.

Box 1475 Baltimore, Maryland 21203

Northeast Nuclear Energy Company William H. Cuddy, Esquire Day, Berry

& Howard Counselors at Law One Constitution Plaza Hartford, Connecticut 06103 Anthony Z. Roisman Natural Resources Defense Council 917 15th Street, N.W.

Washington, D.C.

20005 Mr. Lawrence Bettencourt. First Selectman Town of Waterford Hall of Records - 200 Boston Post Road Waterford, Connecticut 06385'ortheast Nuclear Energy Company ATTN:

Superintendent Mi11stone Plant Post Office Box 128 Waterford, Connecticut 06385 Director, Technical Assessment Division Office of Radiation Programs (AW-459)

U.

S.

Environmental Protection Agency Crystal Mall A'2 Arlington, Virginia 20460 U. S. Environmental Protection Agency Region I Office ATTN:

EIS COORDINATOR John F.

Kennedy Federal Building

Boston, Massachusetts 02203 Waterford Pub1ic Library

'ope Ferry Road, Route 156 Waterford, Connecticut 06385 Mr. John T. Shedlosky U.

S. Nuclear Regulatory Commission P. 0.

Drawer KK

Niantic, CT 06357 Connecticut Energy Agency

~ ATTN:

Assistant Director, Research

~

and Policy Development Department of Planning and Energy Policy 20 Grand Street Hartford, Connecticut 06106 Mr. W.

G. Counsil, Vice President Nuclear Engineering and Operations Northeast Nuclear Energy Co.

P. 0.

Box 270 Hartford, Connecticut 06101 Northeast Utilities Service Company ATTN:

Mr. James R. Himmelwright Nuclear Engineering and Operations P. 0.

Box 270 Hartford, Connecticut 06101

Fl'orida Power 8 Light Company R'obert Lowenstein, Esquire Lowenstein,

Newman, Reis 5 Axelrad 1025 Connecticut
Avenue, N.W.

Washington, D;C.

20036 Norman A. Coll, Esquire McCarthy, Steel, Hector 8 Davis 14th Floor, First National Bank Building Miami, Florida 33131 Indian River Junior College Library 3209 Virginia Avenue-Fort Pierce, Florida 33450 Mr. Hamilton Oven, Jr., Administrator Florida Department of Environmental Reg.

Power Plant Siting Section Montgomery Building 2562 Executive Center Circle Tallahassee, Florida 32301 Mr. Weldon B. Lewis County Administrator St: Lucie County 2300 Virginia Avenue, Room 104 Fort Pierce, Florida 33450 Director, Technical Assessment Division.

Office of Radiation Programs

'(AW-459)

U. S.

Environmental Protection Agency Crystal Mall ¹2 Arlington, Virginia 20460 U.S. Environmental Protection Agency Region IV Office ATTN'IS COORDINATOR 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Mr. Jack-Shreve Office of the Public Counsel Room 4, Holland Bldg.

Tallahassee, Florida 32304 Bureau of Intergovernmental Relations 660 Apalachee Parkway Tallahassee,'lorida 32304 Dr. Robert E. Uhrig Vice President Florida Power 8 Light Co.

, Advanced -Systems 8 Technology P. 0.

Box 529100 Miami, Florida 33152