ML17206A588

From kanterella
Jump to navigation Jump to search
Forwards LER 78-044/03L-0
Date released: 01/25/2018 Download: ML17206A588


LER 78-044/03L-0 on 781121:motor Operated Valve Mv 07-13 Failed to Open Electrically Following Closure Due to Faulty Torque Switch on Valve Operator.Switch Replaced & Valve Checked
ML17266A019
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 12/20/1978
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17266A019 (1)
Forwards LER 78-044/03L-0
ML17206A587
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 12/20/1978
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17206A587 (4)