ES-301 Simulator Scenario Quality Checklist Form ES-301-4 Facility: PBNP Date of Exam: 5lB - 5119, 2017 Scenario Numbers: 1 I 2 I 3l 4 Operating Test No.: 2017 QUALITATIVE ATTRI BUTES lnitials a

b.

c#

The initial conditions are realistic, in that some equipment and/or instrumentation may be out of service, but it does not cue the operators into expected events.

/4 'fv t

2. The scenarios consist mostly of related events.

,,4 f1" (,

3. Each event description consists of the point in the scenario when it is to be initiated the malfunction(s) or conditions that are entered to initiate the event the symptoms/cues that will be visible to the crew the expected operator actions (by shift position) the event termination point (if applicable)

/

l\\- "

4. The events are valid with regard to physics and thermodynamics.

h/ fv

?/

Sequencing and timing of events is reasonable, and allows the examination team to obtain complete evaluation results commensurate with the scenario objectives.

r;/ f\\-- (/-

C) lf time compression techntques are used, the scenario summary clearly so indicates.

Operators have sufficient time to carry out expected activities without undue time constraints.

Cues are given.

J/ P f

7. The simulator modeling is not altered

/r,1 n-9' The scenarios have been validated. Pursuant to 1 0 CFR 55.46(d), any open simulator performance deficiencies or deviations from the referenceci plant have been evaluated to ensure that functional fidelity is maintained while running the planned scenarios.

.4/ fu-

@r 9

Every operator will be evaluated using at least one new or significantly modified scenario. All other scenarios have been altered in accordance with Section D.5 of ES-301.

ø1 P ç.'

1 0. All individual operator competencies can be evaluated, as verified using Form ES-301-6 (submit the form along with the simulator scenarios).

.¿/ P l/

11. The scenario set provides the opportunity for each applicant to be evaluated in each of the applicable rating factors. (Competency Rating factors as described on forms ES-303-1 and ES-303-3.)

/,/ rt k

12. Each applicant will be significantly involved in the minimum number of transients and events specifed on Form ES-301-5 (submit the form with the simulator scenarios).

._¿,/ n- /

13. The level of difficulty is appropriate to support licensng decisions for each crew position.

-4/ 'lw I Target Quantitative Attributes (Per Scenario; See Section D.5.d)

Actual Attributes 1.

lValfunctions after EOP entry (1-2) 2t3t3l3 it f-L 9

2.

Abnormal events (2-4) 5t3l4l3

'-¿l f*

ç,

3.

Major transients (1*2) 1t2t112 ltt ft, I

4.

EOPs entered/requiring substantive actions (1-2) 1t2t113 JI f-\\- ç

5.

EOP contingencies requiring substantive actions (0-2) 0t1l0l1

l'"/ P

(

6.

EOP based Critical tasks (2-3) 21212l2

-4/ lv NOTE

. The facility signature is not applicable for NRC-developed tests

  1. lndependent NRC reviewer initial items in Column "c"; chief examiner concurrence required.

Notc l: NC o^-ciIo va);,)nh'on arh'"i*i¿ç lp Lc çonpt<-feJ /""n1 Wtek of /1y;l 10,

^017,