7590-01 U. S.. NUCLEAR *REGULATORY COMMISSION DOCKET NOS. 50-237, 50-249, 50-254 AND 50-265 COMMONWEALTH EDISON COMPANY NOTICE OF DENIAL OF APPLICATION By letter dated September 15, 198l~*to Commonwealth Edison Company
)'
'. J,_.
- 1
' I (the lic~nsee), the Nuclear Regulatory Commission (the Corrrnission) has *
- j.
- denied the licen~ee's application dated October 28, 1976.
This applica-tion~ requested Corrrnission approval to allow the licensee to opera!te with one relief valve out of service at each of its Dresden Nuclear Power Station, Units 2 and 3, and Quad Cities Station, Units 1 and 2.
These faciliti~s are located in Grundy and Rock Island Counties, Illinois, respectively.
For further details, see the (1) reque~t for action dated October 28, 1Q76, (2) Conrnission staff's request for additional information dated Jp.nuaryS,*1977 and related letters dated Jam~ary 8, 1981 (from.
D. Crutchfield to J. /:.bel) and February 2, 1981 (from T. Ippolito to J.,C.,bel), (3) the lice.nsee's letter dated April 8, 1981 relating to the letters identified in Item (2) above, and (4) the Corn:nission's letter dated.*September 15, 1981, :-=nyin9 appl1catic:11 -/°or failure to sL:~*~*ly inf9rrr.ation.
.A.11 of these docu!i1ents are available at the Corrrnission's P~~lic Document Room, 1717 H Street, N.W'., Washington, D. C., the Morris Public Library, 604 ~iberty Street,.Morris, Illinois (Dresden Station):,,*
and at the Moline Public Library, 504 17th Street, Mol1ne, Illinois (Quad Citi~s).
Dated at Bethesda, Maryland, this 15t~ day 6f S~~lember, 1981.
-a1*1-0010095--e1091'5 7
PDR ADOCK 0500023 p_ --*--*--~--J PO_B Le;; ~u~
1 c~;;ssJON Dennis M. Crutch~~:*.*
Operating Reactor~.Branch #5 l Division of Licensing
- j*
Docket Nos. 50~237,. 50*249, 50~254, 50-265 tsos-a1.
Mr. J *. s *. Abel Dir-ecgor.of Nuclear licensing Commonweal:t;h *Edison Company Post.Offiee Box 767.
Ch1cago 9. 11 HnoiS 60690
Dear Mr.. Abe 1 :
r~
DISTRIBUTION:
Dockets. ( 4)
NRC PDR.$.(4)
LPDRs (4)
TERA ( 4 )t NSIC (4)/
HDenton(
ECase
~--
DEi senMt Glaihas DCrutchfield HSmith (2)
PO'Connor OELD OI&E (3)
GDeegan. (16)
ACRS {],Q)
RDiggs RBevan Tippol ito SMorris
SUBJECT:
DRESDEN STATION 2 ANP.3 AND* QUAD CITIES STATION *. ND 2,..
DENIAL OF REQUEST FOR *APPROVAL' ro:*~llERAT.E Wl NE RELIEF VALVE *OUT OF SERVICE.
'"'We~have received your letter diited.April a, l98 0 in -response to.o~r letters dated January a,.
d February 2,. 1981 whtch reque~ts that the
.NRC staff keep your.Octob r 28, 1976 reque *. for ~pproval"\\to.operate.
- -\\ with one relief.valve.out of service 1n inactive status.rather than considering i.t :withdrawn.
By letter dated January 5, 1977, t staff requested additional 1nfor-m~tion related to this 1ss e *. Fa years.have ll~Jtsed since.our request
~
fo_r the addition.al 1hforma ion.
Commo_nwea1th Edison has sta.ted th~t~
li_.'tt".
- ~
is pursuing :this action on w priority!
. 1~.:,. ~
1 ;rQ..:, ~"'t' t~ ~U/~~
Accordingly*.your applicat n 1$ ~ereby denied.A You may re*submi~ your application. at a.future t, accompanied by ~r,~ requested fnfonnati.on anq the appropr-fate lt. n:Se ee.
cc: See next page
- .SEE ATTACHED YELLOW FOR PREVIOUS CONCURRENCES
/
(
ays from the date of this letter.
Sincer~1y.
Darrell G. Eisenhut, 01rec:tor D.iv1s1on of l fcensing.
DL:ORB #2/PM RBevan 5/20/8i*
_ _oFF.'.~E* ~ ~.:. ~'.~~.. ~ ?/ ~*~:. -~~
.. :. ~-~?-~ /_lft: _i **. :.. ~E.LD.... *..... 0.~ :. O_RB.. ~ ~(C.,. D L.:. ~_D f.SA....... ; :.o~: _D~B.: #.?f.C.. ;. L.: °.! _R..........*
lsURNAME. ~Q.'J.<?n~.qr. ;*q:.. :...... 1.t.... ~.. :.. J~9.1 m?.t~~.<L.... Q~r~ t.~r.f.1. ~.1 ~.: -~-~9: Ul?-.~......... i ** II.PP.~ 1.1 t.9..... J.1 ~-~n~.YL.....
DATE~: 7/o'V81
//6/81 5/07 /81*.
5/27/81*. *. 5/27 /81*
5/20/81*
- 7 I
/81
. NRC FORM -3.18.1101801 NRCM E>.2AO *
- > USGPO; 1980-329*824..,.,
. DISTRIBUTION Docket files (4)
NRC PDR (4)
L PDR (_4 r Docket Nos. 50-237 /249 254/265 ORB#5 Reading TNovak RTedesco GLainas DEisenhut RDiggs HDenton NSIC TERA LSOS Mr. *J. S. Abel HSmith (2)
P0 1 Connor D Crutchfield OELD
- *- 'Director of Nuclear T1c'ehs'i'ng Coml)lOnwealth Edison Company Post Office Box 767 OI&E **(5) */*
TBa rnh*a.rdt ( 16)
'Acf~s- (16)
Dear Mr. Abel:
SUBJECT:
DRESDEN STATION 2 ANO 3 ANO QUAD CITIES STATION l AND 2, DENIAL OF REQUEST FOR APPROVAL TO OPERATE ONE RELIEF VALV VT OF SERVICE letter dated April 8, 1981 in response to our letters dated-Januar 8, and February 2, 1981 which requests that the
- NRC staff keep your Oc ober 28, 1976 reques for approval to operate with one relief valve o t of service in a inactive status rather than c?ns i deri'ng. i-t with draw _
/
By letter date'd January' 5, 1977, toe sta.ff requested addtt1onal infor-mation related to this iss
- Foor years have passed since our request for the additional informat n Commonwealth Edison has stated that it is pursuing this action o a low priority.
Accordingly, your appli ation i hereby denied.
You may resubmit your application at a futu date,,ace mpanied by the requested information and the appropriate. 1cense fee.
A copy of a Not e, which has been fo arded to the Office of the Federal Regis. r for publication, is e closed. Within thirty _(30) days after p lication of this Notice i the Federal Register, Commonwea)Y~ Edison Company may request a hearing.
j/
S1-ncere ~
Darrell G. Eisenhut, Director Division of Licensing cc: See next page ORB#2:DL RBevan*
5/20/ 81
- fD
.~
~FFICE. * ~~.~~?. * * * *..... ~.9~~:.........
~!.~.~~.~.~.=.~~ * * *... ~~.~~~.: ~~*-*..... ~(~~~.~?.:.~~. * * * *..
~:.~~ * * * * * * * * * * *
- SURNAME ** ?.9.l.~9n~9.t::.. ry.~~~1.o/......... ~....
......... ~.~!'.:~.~~.~.~].~ ].9... ~~.~ ~.~.~?.~....... nPP.9.1~.~.~~._..... ~~.i.~.~~~.~~.....
BATE~.~/IQ/?.1......... ~!(Q.~~]... ~......!?.. ~.........
.~(~?/~~........... ~(~!.(~~......... ~(~~/~~........... ~!.... !.~.l........
/
_NRC l"ORM*.31811El/801'NRCM El2-'1()
ECORD COPY
- USGPO: 1980-329-824
I
- ~
- "',.~*......
/ ~
Docket Nos. 50-237/249 254/265 LSOS Mr. J
- S. Abe 1 Director of Nuclear Licensing Commonwea.th Edison Company Post Office Box 767 Chicago, Ill ois 60690
Dear Mr. Abel:
SUBJECT:
DRESDEN riJATION 2 AND 3 AND QUAD CITIES STAtION 1 AND 2, DENIAL OF EQUEST FOR APPROVAL TO OPERAT-E/ONE RELIEF
- VALVE*OUT SERVICE We have received your let er dated April
, 1981, in response to our letters dated January 8, a February 2, 981, which requests that the NRC staff keep your Octo er 28, 19 request for approval to operate with one relief valve ut of ervice in an inactive status rather than considering it wit raw
- By letter dated January 5, 1977,; ~e staff requested additional infor-mation related to this issue.nl~ou~ears have passed since our request for the additional informatio;:
Co nwealth Edison has stated that it is pursuing this *action on a low p iority.
Accordingly, pursuant to l/cFR 2.108,
- ur application is hereby denied.
You may resubmiVyour applicatio at a future date, accompanied by the requested information and the app~o iate license fee.
A copy of a Notice, wh,/ch has been forwar~e~ o the Office of the Fed~ral.
Register for publication, is enclosed.
I
Enclosure:
Notice
_,>.IRC !"ORM 318110/801.NRCM 02*Hl Sincerely, Darrell G. Etsenhut, Director Division of Licensing OFFICIAL* RECORD COPY
- USGPO: 1980-329*824
- >..~ - '.
.*~.
~ *t..
-**,, ~---*. \\J, ______ *-
~-.
Docket Nos. 50-237/249 254/265 LS05 Mr. J
- S. Abe 1 Director of Nuclear Licensing
... conunonweal th Edison.Company.,
Post Office Box 767
.Chi ca go, ll l 1noi s 60690
Dear Mr. Abel:
We nave received your letter dated April 8, 1981 which requests that the NRC staff keep your October 28, 1976 request for. approval to operate with one relief valve out of service in an inactive status rather than considering it withdrawn.
Based upon the fact that four years have passed s.ince our request for additional information, we find that Conmonwealth Edison is not pursuing this action with sufficient vigor to warrant our continued involvement with the issue.
\\
Accordingly, your request is hereby denied.
You may resubmit your request at a future date, accompanied by the requested information and the appropriate license fee.
cc: See next page Sincerely, Gus C. La1nas, Assistant Director for Safety Assessment Division of Licensing a
~---
- 1.
- 2.
- 8.
(
ROUTING AND TRANSMITTAL SUP
- (Name. office symbol, room number, bulldin& Agency I Post)
- Smith For Correction For Your Information mment Investigate Coordination Justl
- Date 09/04/81
. Initials Date REMARKS rr,.,., LL co. ~ j ~-.
~
..... fl>
J
~
l lve apologize for again~~*
notice and letter of denial in this matter.
We have taken the statement that the public notice is given as a matter of discretion out of the Federal Regi*ster notice and put it in the referenced.
lette~ to th~ applicant. Joe Scinto has concurred in this rewording.
j
'.[~Cl
.. µ<? ~'2 ~Q~ ~p_
DO NOT use* this form* as.a RECORD1~oncurrences, ~
clearances, and similar actions FROM: (Name, org. symbol, Agency P Edw'n J. Reis Ass stant Chief He 5Gt1-102
~U.S. G.P.O. 1977-241-530/3090 Room No.-Bldg.
Phone No.
X27505 OPTIONAL FORM 41 (Rev. 7-76)
Prescribed ~-GSA FPMR (41 CFRJ 101-11.206
{
(
(,
---'----~. ill. ~+ *_ c.Qg~_\\o '\\A,U_
CJ*~
\\ :._.
- ~
~
~
- -~--~~**
=-=~-~-=-=--------
--'----~-*
- .~c._:_*
___,,.~~~~**~-*~**."*~* ~---=------------
~---~~. *~~~-**_i~u~~*~-*-~~~-~~.~
'l.-
~---*-------- -------
---~~-~
~
"--~----------
---~--- --74i---- ________,, ___ _
-r
~------'------'-----~----~----*-----------* --
---~c ----------------.~~- *--'-~
.;::------~--------
(
. (
U. S. NUCLEAR REGULATORY COMMISSION.
DOCKET NOS~ 50~237, 50-249, 50~254 AND 50-26~
COMMONWEALTH.EDISON COMPANY NOTICE OF DENIAL OF APPLICATION 7590-01 By letter dated to the Commonwealth Edison Company (the licensee), the Nuclear Regulatory Commission (the Corrunission) has denied the licensee's application dated October 28, 1976.
This applica-tion requested Commission approval to allow the licensee to operate with one relief valve out of service at each of its Dresden Nuclear Power Station, Units 2 and 3, and Quad Cities Station, Units 1 and 2.
These facilities are located in Grundy and Rock Island Counties, Illinois, respectively.
For. further details,' see the ( l) request for action dated October 28, 1976, (2) Commission' staff's request for addftional information dated January 5, 1977 and related letters dated January 8, 1981 (from D. Crutchfield to J. Abel) and February 2, 1981 (from T. Ippolito to J. Abel), (3) the licensee's letter dated April 8, 1981 relating to the letters identified in Item (2) above, and (4) the. Corrrrnissi,on's letter dated denying application for failure to supply information.
All of these documents are available at the Commission's Public Document Room, 1717 H Street, N.W., Washington, D. C, the Morris Public Library, 604 liberty Street,,Morris, Illinofs (Dresden Station),,*
and at the Moline Public library, 504 17th Street, Mollne,,Illinois (Quad Ci ti.es).
or by the Commission' discretionary I
e e
UNITED STATES NUCLEAR REGUL_ATORY COMMISSION
. WASHINGTO,N, D'. C. 2055.5 Docket Nos. 50-237, 50-249, 50-254, *50-265 LS05-81 Mr. J. S. Abel
. ~ecgor of Nuclear Licensing Commonwealth Edison Company Post~Office Box 767 Chicago, Illinois 60690
Dear*Mr. Abel:
SUBJECT:
DRESDEN STATION 2 AND 3 AND. QUAD CITIES STATION 1 AND 2, DENIAL OF REQUEST FOR APPROVAL TO OPERATE WITH ONE RELIEF VALVE OUT OF SERVICE We have received your letter dated April 8, 1981, in response to.our letters dated January 8, and February 2, 1981, whi.ch request:~ that the
- NRC staff keep your.October 28, 1976 request**for approval td operate,
with one -relief valve.out of service in an inactive status rather than consi~ering it withdrawn.
By letter dated January 5, 1977, the staff requested additional infor-mation related to this i~sue. Four years.. have passed since our requ~st for the additional informati.on.
Commonwealth Edison has stated that it/I
/ J "
is pursuing this action on a low priority.
f~~
-~7;:::4'-~"";j,
Accordi.ngly, your application is hereby denied.tYou ~~your ~,
application at a future date, accompanied by the requested information and the appropriate license fee.
You may request a hearing 30 days from the date of this letter.
cc: See next page Sincerely, Darrell G. Eisenhut, Director Division of Licensing
Mr. J. S. Abel 2 -
Enclosure:
Notice cc w/enclosure:
(
(
U. S. NUCLEAR REGULATORY COMM I SS IO" DOCKET NOS. 50-237, 50-249, 50-254 AND 50-265 COMMONWEALTH EDISON COMPANY NOTICE -OF DENIAL OF APPLICATION 7590-01 By letter dated
'to Commonwealtl:1 Edison Company (the licensee), the Nuclear Regulatory Commission (the Commission) has denied the licensee's application dated October 28~ 1976~ This applica-tion requested Corrmi ss ion approva 1
- to a 11 ow the licensee to operate with one relief valve 6ut of service at each of its Dre~den Nuclear Power Station, Units 2 and 3, and Quad Cities Station, Units l and 2.
These facilities are located in Grundy and Rock Island Counties, Illinois, respectively.
For further details, see the (1) request for action_ dated October 28, 1976, (2) Commission staff's* request for additional information dated January 5, 1977 and related letters dated January 8, 1981 (from D. Crutchfield to J. Abel) and February 2, 1981 (from T.. Ippolito to J. Abel)., (3) the_ licensee's letter dated April 8, 1981 relating to the letters identified in Item (2) above, and (4) the Commission's letter dated denying application for failure to supply information.
All of these documents are available at the Corrmission's Public Document Room, 1717 H Street, N.W., Washington, D. C, ttie Morris Public Library, 604 Liberty Street, Morris,. Illinofs (Dresden Stationh' and at the Moline Public Library, 504 17th Street, Mollne, Illinois (Quad Ci ti es).
Dated at Bethesda, Maryland, this FOR THE NUCLEAR REGULATORY COMMISSION Dennis M. Crutchfield, Chief Operating Reactors Branch #5 Division of Licensing
- J I
"~*:, _; _,j,..
Note to Hazel Smith July 1. 1981 Thank you for revising this notice along the earlier note.
I have, however, changed~m--
for the 1
tter (it should be cast in terms o 30 da *5 rom the date of the let er. However, I think that ~~-_.._TH a Federal eg1ster Notice in the form we have drafted is not advisable.
It appears to be a notice of denial which does not contain the information required by section 2.108(b).
Thus, it appears to be a defective no ti ce--i n its failure to pro vi de an opportunity for hearing by any persons who may be affected. This notice is not required by
->-N::-'::t!J:J~
section 2.108(b), but would be a discretionary notice.
Consequently, it need not fully comply with section 2.108(b).
However, the nature of the notice is not clear and unless we make it very clear that the Federal Register Notice is not a notice required by the regulations but is a notice we are providing simply as a matter of the agency's discretionar authorit to inform eo Te of our activities the en s to be confusing an ten s to appear to e erroneous w1th respect.
to an important legal right.
A notice that ~p at odds with the provisions of section 2.108(b) is no
~,~............_-
cc: P. O'Connor l/"'
R. Purple
- ~
Docket Nos. 50-237/249 254/265 LS05 Mr. J. S. Abe 1 Director of Nuclear Licensing Commonwealth Edison Company Post Office *Box 767 Chicago, Illinois 60690
Dear Mr. Abel:
SUBJECT:
DRESDEN STATION 2 AND 3 AND QUAD CITIES STATION 1 AND 2, DENIAL OF REQUEST FOR APPROVAL TO OPERATE\\ONE RELIEF VALVE OUT. OF_.SERVICE
-LNi~
We have received your letter dated April 8, 1981, in response to our letters dated January 8, and February 2, 1981, which requests that the NRC staff keep your October 28, 1976 request for approval to operate with one relief val.ve out-of*service in an inactive ~tatus rather than considering.it withdrawn.
By letter dated January 5,' 1977, tbe staff requested additional infor-mation related to this issue.
Four years have passed since our request
!or.the add~tiona~ info~mation.
Commo~we~lth Edison has stated tAhat. ~, ~~
1t_ 1s pursuing th1s.. a.ct1pn on a low pri rity.
, ~"/~~-~~#
Accordingly, your a*pplication is hereby enied.
You may resubmit your 1 application at a future date, accompanied by ~equested information and the appropri~te license fee.
. -l Go p-y-of-.a-No-t--i~e~:~wh.ich--h a-s--been-**-f o.rwarde*d**-to--tm~-offfce-oi_=t°h~~.=.\\,
~ederav~_st~~qf6( p_ubi-i-ea~ion.., __ ~s--e~-crosed.. ---W-i'thin t~irty (30)[
aa.y~s:.:gft ~ r pub 1 1 cat lo n *-of~th;-s-Net-1-e-e-ln--tb e....E.e_<;l_e.r.ii_LH.e_g_i:s_te.r-,.--.. ---*
nwea+th-Edi'son Comp-a-r:i1'may requ*e~t a hearing..:r0 j---~.J ~~
~
.. -~-------~(A.,I.
Sincerely, *
µ-..:*~
cc:
See next page.
rv -
f/1.,Jt I.>
Darrell G.. E~*senhut, Director
~~.G Di vj s ion /of "Licensing
- ~
..;""1 *:..
) ***',, *.,,
~,t
- ' I.~
'. -'.. ii
('.
U. S. NUCLEAR REGULATORY COMMISSION DOCKET NOS. 50-237, 50-249, 50-254 AND 50-265 COMMONWEALTH EDISON COMPANY NOTICE OF DENIAL OF APPLICATION
/!:>YU-UI By letter dated to the Commonwealth Edison Company (the ilicensee), the Nuclear Regulatory Commission (the -Corrunission) has denied the licensee's application dated October 28, 1976.
This applica-tioh requested Corrunission approval to allow the licensee to operate with one relief valve out of se~vice at each of its Dresden Nuclear ~ewer Station, Units 2 and 3, and Quad Cities Station, Units 1 and 2.
These facilities are located in Grundy and Rock Island Counties, Illinois, respectively.
For further details, see the (1) request for action dated October 28, 1976, (2) Corrunission staff's request for additional information dated January 5, 1977 and related letters dated January 8, 1981 (from D. Crutchfield to J. Abel) and February 2, 1981 (from T. Ippolito to J. Abel), (3) the licensee's letter dated April 8, 1981 relating to the letters identified in Item (2) above, and (4) the Commission's letter dated denying application for failure to supply information.* All of these documents are available at the Corrunission's Publit Doc~ment Rbom, 1717 H Street, N.W., Washington, D. C., the Morris Public Library, 604 Liberty.Street, Morris, Illinois (Dresden Station),..
- and at the Moline Public Library, 504 17th Street, Mol1ne, Illinois (Quad Cities).
I.
J..
. e Docket Nos; 50-237/249 LS05-8l-254/265 Mr. J. S. Abel Director 6f Nuclear Li~ensin Commonwealth Edison Company Pait Office Box 767 thicago, Illinois 60~90
Dear Mr. Abel:
WASHINGTON, D. C. 205S5
SUBJECT:
'DRESDE.N STATION*2 AND 3 AND QUA. 'C
!ES SJATIQN 1 AND 2, DENIAL OF REQUEST FOR APPROVAL T OPERATE ONE RELIEF VALVE OUT OF SERVICE.
We have~re eived your letter d~ted Apri
. letters 1dat January* 8., and February.,
the NRC ~taf keep your October 28, 1 76 request for operate with o e relief valve out of service in an **
rather than con idering it withdraw.
- A. copy of *a Nati ce, which Register fpr publicatio
~~
'-\\./~**
- r,.'
Dar ell G. Eisenhut, 'Director Div'; *on of Licensing *
Enclosure:
Notice cc w/enclosure:
. *See next page
\\J
.\\\\**. \\.,'*
- -\\
. \\
~l l
.~.)
~~c ~ <:?z___j) *~.~~~<---
C:lJ
~ t;:;/ J:> i r
~ ~-
U. S. NUCLEAR REGULATORY COMMISSION DOCKET NOS.
50-237~ 50-249, 50-254 AND ~0-265 COMMON\\*JEAL TH EDISON COMPANY NOTICE OF DENIAL OF APPLICATION 7590-01 By letter dated*
to the Commonwealth Edison Company (the,licensee), the Nu*clear Regulatory Commission (the Commission) has r
denied the licensee's application ?atep Octo.ber 2~, l9761
~-1~s"'aa'"rTi1L--+t-o-
- lQ.._CFR se*ction 2 1o'g o.ftl:rn Commjssion'sreg11latiefl3J This application requested Commi~sion approV~l to allow th~ licensee.to operate with one relief.valve out of servi~e at ~ach of *its Dresden Nucl~a~ Power.
Station, Units 2 and 3~ and Quad Cities Station, Units l and 2.
These
. fa'cilities are located in Grundy and Rock Island Counties, Illinois, respectively.
For further details, see the (1) request for action dated October 28, 1976, (2) Commission staff's request.for.additional information dated January 5, 1977 and related* letters d~ted Januafy 8, 1981 (from
""!;-t D. Crutchfield to J. Abel) and*February 2, 1981 (from T. Ippolito to J. Abel), (3) the lice~see's letter dated April 8, 1981 r~lating to the letters identified in Item (2) above, and (4) the Commission's letter dated de~~ing ;pplic~tio~ for failure to supply information.
All of' these documents are available at the Co.mmission's Public.Document Room, 1717 H Street, N.W., Washington, D. C., the.Morris
- Public Libra'ry, 604 Liberty Street, Morris, Illinois (Dresden Station),*"
and at the Moline Public Library,, 504 17th Street, Mollne, Illinois
('Quad Cities).
(
(
J m (N~~:::T::::~* SUP Dam ~~~4/81 building, Agency/Post)
,rtt--.._
- 1.
-r. a I Com 10 r
~'-P'--f...-P~,_..+,f---'1-f--+---;-~
File Note and Return For Clearance Per Conversation For Correction Prepare Reply For Your Information See Me Investigate Signature Justi 6..
Rosetta - assign number
- 7.
Donna - dispatch
- 4sa ~*
1
~*
DO NOT use this form as a RECORD of approvals, concurrences, disposals,
- clearances, and similar actions FROM: (Name, org. symbol, Agency/Post)
Room No.-Bldg.
~U.S. G.P.O. 1977-241-530/3090 Phone No.
OPTIONAL FORM 41 (Rev. 7-76) 1 Prescribed ~ GSA FPMR (41 CFR) 101-11.206
l I
)
(
_.,............ §tf;::J
- ........-1(.~
=-
ROUTING AND TRANSMITTAL SLIP
(
Date 5/13/31 TO: (Name. office symbol, room number, Initials Date *
- building, Agency/Post)
- 1.
Gus Lainas
~
- 2.
\\
- 3.
- 4.
- 5.
~ction.
File Note and Return
~pproval
- For Clearance Per eonv.ersation As Requested For: Correction Prepare Reply
- Circulate For Your Information*
See Me Comment Investigate Signature Coordination Justlfv
- REMARKS The provision providing for a denial of an applj.. caJ:ion for a license or an amendment is" 10 CFR §~
There is no need for a dis-C'LiSS10n of whether or not they are pursuing the matter. with vigor.
Four
- ears are longer than 30*da~..........---r15elieve it has been a custo ln denial letters to provide a notice to the licensee of his opportunity for a hearing, even in cases not covered by§§ 2.108(b) and (c).
- DO NOT use this form as a RECORD of approvals, concurrences, disposals, clearances, and similar actions FROM: (Name, org. symbol, Agency/P Room No.-Bldg.
Joe.Scinto Phone No.
5041'-102 PTIONAL FORM 41 (Rev. 7-76.
Prescribed ~
GSA tr U.S. GOVERNMENT PRINTING OFFICE, 1979-280*18<1JJ It. fP"'.'ij)ft (41 C
) 101-ll.206 I I
)