--r: -*~~\\.. ~ e I Commonwea1t9'tison
'f:-*
One First National Plaza, Chicago, Illinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690 Mr.. Paul O'Connor, Project Manager Operating Reactors U.S. Nuclear. Regulatory Commissi.on Washington D.C. 20555 August 4, 1981
Subject:
SEP Tnpic III-4.B, Turbine Missiles NRC Docket 50/237 Per Mr. John Schiffkin's request at the June l and*2 Dresden site visit the following information is provided.
Radwaste Storage Tank~
T-105A, Unit Contaminated Storage Tank Height 30 feet, Diameter 35 feet Capacity 200,000 gallon~
T~l05B, Unit l Clean De~ineralized Storage.T~nks Height 30 feet,* Diameter 35 fe*et Capacity 200,000 gallons T-108, Unit l Well Water Stora~e-Hei ght 30 feet, *Diameter 35 feet Capacity 200,000.gallons 2/3-A-3303, Unit 2/3 ~ontaminated Storage Height 34 feet 7 inches, Diameter 37 feet Capacity 250,000 gallons*
2/3-B-3303, Unit 2/3 Contaminated Storage Height 34 feet 7 inches, Diameter 37 feet Capacity 250,000 gallons 2001-436, Waste Surge Tank Height 25 feet, Diameter 23 feet Capacity 77,000 gallons A-2001-484-A, Floor Drain Sample Tanks B-2001-484-B, Height 18 feet 6 inches, Diameter 14 feet 6 inches Capacity 22,000 gallons 200l-468A, Waste Sample Tanks 2001-4688, Height 19 feet Diameter 17 feet 6 inches
.2PQ1-468C, Capacity 33,000 gallons
-a i oai 10590-010804
. PDR ADOCK 05000237 p
- ~
Gene~al Electric has stated they will provide the requested information on the turbine discs on July 17, 1981.
Edison will forward the information to you as soo~ as we receive it.
Please address any questions you may have concerning this matter to this office.
One (1) signed original and thirty-nine (39) copies of this transmittal letter have been provided for your use.
In addition six (6) c o p i e s of d r aw i n g M - 1 D 11 P 1 a n t D e v e 1 o pm e n t P 1 a n 11 h a v e a 1 s o b e e. n p r o v i d e d for your use.
NPS:mnh 02.88a c c :
R I I I *R e s i d e n t I n s p e c t i o n D r e s d e n Very truly yours,
- //If~
T. J. Rausch Nuclear Licensing Administrator*
Boiling Water Reactors