ML17192A580

From kanterella
Jump to navigation Jump to search
Forwards LER 80-006/03L-0
Date released: 11/15/2019 Download: ML17192A580


LER 80-006/03L-0:on 800215,during Local Leak Rate Test Performed on a Feedwater Inboard Check Valve 3-220-58A Measured Leakage Exceeded Tech Specs.Caused by Worn Seat/ Disc Assembly Pins
ML19305B358
Person / Time
Site: Dresden 
Issue date: 03/13/1980
From: Ciesla T
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19305B358 (2)
Forwards LER 80-006/03L-0
ML17192A579
Person / Time
Site: Dresden 
Issue date: 03/13/1980
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17192A579 (2)