July 1, 1994 Oc:iC'ket Nos. 50-237 and 50-249
- Mr. D. L. Farrar, Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, Illinois 60515
Dear Mr. Farrar:
SUBJECT:
EVALUATION OF REQUEST FOR RELIEF RELATED TO THE THIRD TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM FOR DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3 (TAC NOS. M89315 AND M89316)
By letter dated February 24, 1994, as supplemented by letter dated April 6, 1994, you submitted Revision 3 to the third ten-year interval inservice inspection (ISi) program plan.
Revision 3 requests the staff's review and approval of Relief Request PR-14, Revision 1, PR-18 and CR-17.
The staff has reviewed the relief requests.
The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation (SE).
The staff has concluded that the alternative testing proposal in Relief Request PR-18 is acceptable and relief is authorized pursuant to 10 CFR 50.55a(a)(3)(ii).
Use of Relief Request PR-18 for joints not classified as hard joints is denied.
Relief request PR-14 was previously granted by letter dated May 25, 1994.
Relief request CR-17 and specific changes in Revision 3 of the ISI program plan will be evaluated under separate cover.
9408080059 940701 PDR ADOCK 05000237 P
Enclosure:
Safety Evaluation cc w/enclosure:
See next page DISTRIBUTION:
Docket File NRC & Local PDRs PDII 1-2 R/F Sincerely, Original signed by:
John F. Stang, Project Manager Project Directorate 111-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation
' ?rfjf\\< ffb~i@~*
\\\\\\RC f*ilJf [~S~~l ct~ il!Jt:;~ ~
OGC BClayton, Riii JRoe RCapra JZwol i nski JStang ACRS (10) r: ;'1 ( ', r* r-,9'1,oore
\\.J ':i:; U \\.) *. ~.J]trosnider, EMCB EMCB OGC D:PDIII-2 JStrosnider*
MYoung*
RCa ra*
07/01 94 07/01/94 07/01 94 YES/NO YES/NO YES/NO pd~}
Jfo' l I
Mr. D. L. Farrar Commonwealth Edison Compa~
cc:
Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. G. Spedl Plant Manager Dresden Nuclear Power Stat*fon 6500 North Dresden Road Morris, Illinois 60450-97~5 U. S. Nuclear Regulatory ~~mmission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, Illinois 60450-97166 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Regional Administrator U. S. NRC, Region III 801 Warrenville Road lisle, Illinois 60532-435Il 111 inoi s Department of Nud:ear Safety Office of Nuclear Facil i t.w.'Safety 1035 Outer Park Drive Springfield, Illinois 627'4 Dresden Nuclear Power Station Unit Nos. 2 and 3