UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Docket Nos.

STN 50-456, STN 50-457, STN 50-454, STN 50-455, 50-237, 50-249, 50-373, 50-374, 50-254, 50-265, 50-295, and 50-304 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Pl ace Downers Grove, Illinois 60515

Dear Mr. Farrar:

December 29, 1993

SUBJECT:

SAFETY EVALUATION FOR PROPOSED CHANGES TO THE EMERGENCY ACTION LEVELS FOR COMMONWEALTH EDISON'S GENERATING STATION EMERGENCY PLAN ANNEXES (TAC NOS. M87325, M87326, M87327, M87328, M87329, M87330, M87331, M87332, M87333, M87334, M87335, AND M87336)

By *1ette*r dated September 1, 1993, as supplemented by letters dated October 1, 1993, November 30, 1993, December 17, December 21, and December 23, 1993, Commonwealth Edison Company (CECo) submitted proposed changes to the emergency action levels (EALs) for the Generating Station Emergency Plan (GSEP) Annexes.

They were reviewed against the guidance in NUMARC/NESP-007, Rev. 2, "Methodology for Development of Emergency Action Levels."

NUMARC/NESP-007 has been endorsed by the NRC in Regulatory Guide 1.101, "Emergency Planning and Preparedness for Nuclear Reactors," as an alternative means by which licensees can meet the requirements of 10 CFR 50.47(b)(4}. and Appendix E to 10 CFR Part 50.

We have completed our review of the submittals and concluded that with the exception of the departures from the NUMARC guidance that were identified and accepted~ the revised EALs are consistent with the guidance in NUMARC/NESP-007, and therefore, meet the requirements of 10 CFR 50.47(b}(4) and Appendix £ to 10 CFR Part 50.

With one exception, all EALs will be implemented by January 1, 1994.

The exceptio~ is the inclusion of an EAL for evaluation of the Fuel Clad and Fission Product Barrier Matrix which will be implemented by March 23, 1994.

For the Potential Loss of the Fuel Clad Barrier condition, CECo committed to add an additional Threshold Value to account for the condition when the n5nn~**1c!

~-Y

\\) t.J 4 U y

fai

r-OFC NAME DATE COPY Mr. D. average of the ten highest core exit thermocouples indicate 708°F for Byron and Braidwood Stations, and 700°F for Zion Station.

Our Safety Evaluations are enclosed.

Sincerely, Original Signed By:

George F. Dick, Jr., Senior Project Manager Project Directorate III-2

Enclosures:

As stated cc w/enclosures:

See next page DI STR IBUT ION Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation Docket File NRC & Local PDRs POI II-2 r /f CMoore RAssa AGodyJr RErickson GDick JRoe JZwolinski JDyer ACRS(lO)

BClayton, Riil JStang CPatel JO' Brien SBoynton JMcCormick-Barger, Riii LA: PD II I"'2 PM: PDI}I-2 D: POI 11-2 CMOORE d,-~ [of. GDICKiJ~/1 JOVER CP~it..

1i. I z..'l;93 u (2../ 2q/93 -,

iv J"lf\\/93 YES/NO tfEs)No YESJNOl

'-.__./

'-..../

I

/93 I

YES/NO OGC HDawson CShiraki TPloski, Riil

/93 YES/NO I

/93 YES/NO

OFC NAME DATE COPY Mr. D. average of the ten highest core exit thermocouples indicate 708°F for Byron and Braidwood Stations, and 700°F for Zion Station.

Our Safety Evaluations are enclosed.

Sincerely, Original Signed By:

George F. Dick, Jr., Senior Project Manager Project Directorate III-2

Enclosures:

As stated cc w/enclosures:

See next page DISTRIBUTION Docket File NRC & Local PDRs JZwolinski JOyer ACRS(lO)

BClayton, RIII JStang CPatel JO'Brien SBoynton JMcCormick-Barger, RIII Division of Reactor Projects - 111/IV/V Office of Nuclear Reactor Regulation POI 11-2 r /f CMoore RAssa AGodyJr RErickson GDick JRoe OGC HDawson CShi raki TPl oski, RI II 0: POI II-2 JOVER CfMl-I

/93 I

/93 YES/NO YES/NO YES/NO I

/93 YES/NO

Mr. D. average of the ten highest core exit thermocouples indicate 708°F for Byron and Braidwood Stations, and 700°F for Zion Station.

Our Safety Evaluations are enclosed.

Enclosures:

As stated cc w/enclosures:

See next page Sincerely,

~~F.~i~~enior Project Manager Project Directorate III-2 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation

Commonwealth Edison Company cc:

Mr. William P. Poirier Westinghouse Electric Corporation Energy Systems Business Unit Post Office Box 355, Bay 236 West Pittsburgh, Pennsylvania 15230 Joseph Gallo, Esquire Hopkins and Sutter 888 16th Street, N.W., Suite 700 Washington, D.C.

20006 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Ms. Bridget Little Rorem Appleseed Coordinator 117 North Linden Street Essex, Illinois 60935 Mr. Edward R. Crass Nuclear Safeguards and Licensing Division Sargent & Lundy Engineers 55 East Monroe Street Chicago, Illinois 60603 U. S. Nuclear Regulatory Commission Resident Inspectors Office Rural Route #1, Box 79 Braceville, Illinois 60407 Mr. Ron Stephens, Director Illinois Emergency Services and Disaster Agency 110 East Adams Street Springfield, Illinois 62706 Robert Neumann Office of Public Counsel State of Illinois Center 100 W. Randolph, Suite 11-300 Chicago, Illinois 60601 EIS Review Coordinator Environmental Protection Agency Region V 230 S. Dearborn Street Chicago, Illinois 60604 Chairman Will County Board of Supervisors Will County Board Courthouse Joliet, Illinois 60434 U. S. Nuclear Regulatory Commission*

Byron Resident Inspectors Office 4448 North German Church Road Byron, Illinois 61010-9750 Ms. Lorraine Creek Rt. 1, Box 182 Manteno, Illinois 60950 Mrs. Phillip B. Johnson 1907 Stratford Lane Rockford, Illinois 61107 Attorney General 500 South 2nd Street Springfield, Illinois 62701 U. S. Nuclear Regulatory Commission Resident Inspectors Office 105 Shiloh Blvd.

Zion, Illinois 60099 George L. Edgar Newman & Holtzinger, P.C.

1615 L Street, N.W.

Washington, D.C.

20036 Commonwealth Edison Company Byron Station Manager 4450 North German Church Road Byron, Illinois 61010 Illinois Dept. of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Commonwealth Edison Company Braidwood Station Manager Rt. 1, Box 84 Braceville, Illinois 60407 Chairman, Ogle County Board Post Office Box 357 Oregon, Illinois 61061 Mayor of Zion Zion, Illinois 60099 Howard A. Learner Environmental Law and Policy Center of the Midwest 203 North LaSalle Street Suite 1390 Chicago, Illinois 60601

1-Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. G. Spedl Plant Manager Dresden Nuclear Power Station Rural Route #1 Morris, Illinois 60450 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, Illinois 60450-9766 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Phillip P. Steptoe, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 Assistant Attorney General 100 West Randolph Street Suite 12 Chicago, Illinois 60601 Resident Inspector/LaSalle, NPS U. S. Nuclear Regulatory Commission Rural Route No. 1 P. 0. Box 224 Marseilles, Illinois 61341 Chairman LaSalle County Board of Supervisors LaSalle County Courthouse Ottawa, Illinois 61350 Dr. Cecil Lue-Hing Director of Research and Development Metropolitan Sanitary District of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 Robert Cushing Chief, Public Utilities Division Illinois Attorney General's Office 100 West Randolph Street Chicago, Illinois 60601 LaSalle Station Manager LaSalle County Station Rural Route 1 P. 0. Box 220 Marseilles, Illinois 61341 Chairman Illinois Commerce Commission Le 1 and Building 527 East Capitol Avenue Springfield, Illinois 62706 Mr. Stephen E. Shelton Vice President Iowa-Illinois Gas and Electric Company P. 0. Box 4350 Davenport, Iowa 52808 Mr. Richard Bax Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Resident Inspector U. S. Nuclear Regulatory Commission 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, Illinois 60515