Forwards LER 79-029/03L-0
Date released: 09/30/2019 Download: ML17173A902


LER 79-029/03L-0 on 790508:DIS 1400-3,pressure Switch 2-1430-1466D Failed to Trip.Caused by Sticky Plunger in Pressure Switch.Switch Removed,Cleaned & Reset to Trip at 94.5 Psig Increasing
ML19259C068
Person / Time
Site: Dresden 
Issue date: 06/05/1979
From: Galen Smith
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19259C068 (1)
Forwards LER 79-029/03L-0
ML17173A901
Person / Time
Site: Dresden 
Issue date: 06/05/1979
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17173A901 (2)