a November 21, 19.

Docket Nos.

50-387 and 50-388 Hr. Harold W. Keiser Senior Vice President

- Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Al1 entown, Pennsy 1 vani a 18101

Dear Hr. Keiser:

SUBJECT:

., TOPICAL REPORT PL-NF-90-001, "APPLICATION OF REACTOR ANALYSIS METHODS FOR BWR DESIGN AND ANALYSIS," SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1

AND 2, (TAC NOS.

H75999 AND H76000)

By letters dated August 8, 1990 and August 29, 1991, Pennylvania Power and Light Company, requested NRC review and approval of Topical Report PL-NF-90-001, "Application of Reactor Analysis Methods for BWR Design and Analysis" for Susquehanna Steam Electric Station (SSES),

Units 1 and 2.

Based upon the staff's review, as given in the enclosed Safety Evaluation, we find the application of PL-NF-90-001 acceptable for use in reload analyses for the

SSES, Units 1 and 2 under the limitations delineated in the associated technical evaluation.

This completes the staff effort on this issue and closed TAC NOs.

H75999 and M76000.

Sincerely,

/S/

James J. Raleigh, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DISTRIBUTION j~

I NRC

& Local PDRs PDI-2 Reading SVarga JCalvo CHi 1 1er J Raleigh HO'Brien(2)

OGC EJordan 3701 ADRS(10 RBlooghi RGN-1

JWhite, RGN-I SI3IIC Id=i%,E CBPTR CIPV
PDI-27D
CMi 1 1 e Ii I

9i120h02ea 9S g iar PDR ADOCN 05000387 PDR C:

A

,:D-P RANE:$0 '

JRaleig b

DATE: (

)91 9'I 7o7(791

~IIEIIIIOIIII Document Name:

SU LTR,75999/76000

I N

~

~

7

~p,Q AE'gy (4

~4 0

Cy 0O

+0

&0

>>>>*<<+

Docket Nos.

50-387 and 50-388 0

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 21, 1991 Mr. Harold W. Kei ser Senior Yice President

- Nuclear Pennsylvania Power and Light Company 2 North Ninth Street Allentown, Pennsylvania 18101

Dear Mr. Keiser:

SUBJECT:

TOPICAL REPORT PL-NF-90-001, "APPLICATION OF REACTOR ANALYSIS METHODS FOR BWR DESIGN AND ANALYSIS," SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1

AND 2, (TAC NOS.

M75999 AND M76000)

By letters dated August 8, 1990 and August 29, 1991, Pennylvania Power and Light Company, requested tlRC review and approval of Topical Report PL-NF-90-001, "Application of Reactor Analysis Methods for BWR Design and Analysis" for Susquehanna Steam Electric Station (SSES),

Units 1 and 2.

Based upon the staff's review, as given in the enclosed Safety Evaluation, we find the application of PL-flF-90-001 acceptable for use in reload analyses for the

SSES, Units 1 and 2 under the limitations delineated in the associated technical evaluation.

This completes the staff effort on this issue and closed TAC NOs.

M75999 and M76000.

Sincerely,

Enclosure:

Safety Evaluation cc w/enclosure:

See next page ames J. Raleigh, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation