ML17157A832

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-387/91-12 & 50-388/91-12 on 910729- 0802.No Safety Concerns or Violations Observed
ML17157A832
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 08/30/1991
From: Joyner J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
Shared Package
ML17157A833 List:
References
NUDOCS 9109090005
Download: ML17157A832 (4)


See also: IR 05000387/1991012

Text

a~~ ~~co>

0

00

,g'

~

~

r

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION I

476 ALLENDALEROAD

KING OF PRUSSIA, PENNSYLVANIA19406-1415

Docket Nos.

50-387

50-388

License Nos. NPF-14

NPF-22

Mr. Harold W. Keiser

Senior Vice President - Nuclear

Pennsylvania Power and Light Company

2 North Ninth Street

Allentown, Pennsylvania

18101

Dear Mr. Keiser:

Subject:

Combined Inspection Nos. 50-387/91-12 and 50-388/91-12

This letter refers to the inspection conducted by Dr. Richard K. Struckmeyer of this office on

July 29-August 2, 1991, ofactivities authorized by NRC License Numbers NPF-14 and NPF-22

at the Susquehanna

Steam

Electric Station,

Berwick, Pennsylvania

and at your office in

Allentown, Pennsylvania.

At the conclusion of the inspection, a discussion of our findings was

held by Dr. Struckmeyer with Dr. K. Shank and other members of your staff.

Areas

examined

during this inspection

included

the implementation of your radiological

environmental

monitoring program

and your personnel

dosimetry

processing

'program

as

described in the NRC Region I Inspection Report which is enclosed with this letter.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative

records, interviews with personnel,

and observations by the inspector.

Within the scope of this inspection, no safety concerns or violations were observed and no reply

to this letter is required.

Your cooperation with us in this matter is appreciated.

Sincerely,

ames H. Jo, Chief

Facilities Radiological Safety

and Safeguards

Branch

Division of Radiation Safety

and Safeguards

9109090005

910830

PDR

ADOCK 05000387

G

,PDR

I

OFFICIAL RECORD

COPY

~C- (,

Pennsylvania Power

2.

and Light Co.

Enclosure:

NRC Region I Combined Inspection Report Nos. 50-387/91-12 and 50-388/91-12

cc w/encl:

A. R. Sabol, Manager, Nuclear Quality Assurance

J. M. Kenny, Licensing Group Supervisor

H. C. Stanley, Superintendent of Plant-SSES

R. G. Bryam, Superintendent of Plant-SSES

'. B. Ungerer, Manager, Joint Generation Projects Department

J. D. Decker, Nuclear Services Manager, General Electric Co.

B. A. Snapp, Esquire, Assistant Corporate Counsel

H. D. Woodeshick, Special Assistant to the President

J. C. Tilton, III, Allegheny Electric Cooperative, Inc.

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

K. Abraham, PAO (2)

NRC Resident Inspector

Commonwealth of Pennsylvania

0

Pennsylvania Power

and Light Co.

bcc w/encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

J. Joyner, DRSS

W. Pasciak, DRSS

J. White, DRP

R. Blough, DRP

P. Kaufman, DRP

DRS SALP Coordinator

DRSS SALP Coordinator

K, Brockman

P, Cortland, NRR

RI:DRSS/~

Struckmeyer

8/~~/91

RI:DRS

Bores

8Ã/91

S

Joyner

8/P/91