se MEMORANDUM fOR:

THRU:

FROM:

SUBJECT:

DV soNN Jack E. Rosenthal, Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data George F. Lanik, Chief Reactor Systems Section GE 5 CE Reactor Opera tions Ana lys i s Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data Theodore C. Cintula, Reactor Systems Engineer Reactor Systems Section GE Im CE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data DELAMINATING FOIL INSULATION IN PRIMARY CONTAINMENT AEOD/T923 This study completes our investigation of the large quantities of loose aluminum o

1 found throughout the drywell during the start of a refueling outage at Sus uehanna-2 (LER 388/88-010).

The aluminum foil resulted from extensive delamination of insulation used in the drywell.

As the NRC has long been concerned with potential sources of debris generation in containment, and because the generic issue was resolved in 1986, the data bases were surveyed to see if similar problems might still be ongoing in the nuclear industry.

The data searches did not find any additional recent events so it would appear that the insulation delamination was an isolated occurrence and further industry action would not be appropriate at this time.

/~/

Theodore C. Cintula Reactor Systems Section GE E

CE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data Distribution:

PDR DSP R/F KBlack HFau 1 kner VBenaroya (Centra 1:file~

TCintula MWi 1 1 iams MTaylor ROAB R/F GLanik TNovak BBrady CHeltemes EJordan CHaughney LSpessard ROAB:ISP:AEOO 7i TCintula: ks 11/ 9/89 89ii280i02 85'1120 PDR ADOCK 05000388 P

PDC R(4 SP:AEOD 11/1 /89 RO

DSP:AEOD JR senthel Jp 11/g,~/89