Notice of Violation from Insp on 890901-02.Violations Noted: on 890831,surveys Not Made to Assure Compliance W/ 10CFR20.101 & Two Individuals Working in Restricted Area Not Adequately Instructed in Precautions or Procedures
ML17156B442
Person / Time
Site: Susquehanna 
Issue date: 11/01/1989
From: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML17156B441 List:
References
50-388-89-25, EA-89-182, NUDOCS 8911080474
Download: ML17156B442 (3)


Text

NOT'ICE OF VIOLATION Susquehanna Steam Electric Station Unit 2 Berwick, Pennsylvania Docket No.

50-388 License No.

NPF-22 EA 89-182 During a special NRC inspection conducted on September 1-2, 1989, violations of NRC requirements were identified.

In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions,"

10 CFR Part 2, Appendix C (1989}, the particular violations are set forth below:

A.

10 CFR 20.201(b) requires, in part, that each licensee make or cause to be made such surveys as may be necessary to comply with the regulations of 10 CFR Part 20.

10 CFR 20.201(a) defines a survey, in part, as an evaluation of the radiation hazards incident to the production,

use, release, disposal or presence of radioactive materials or other sources of radiation under a specific set of conditions.

When appropriate, such evaluation includes a physical survey of the location of materials and equipment and measurements of levels of radiation present.

Contrary to the above, on August 31,

1989, surveys were not made to assure compliance with 10 CFR 20. 101, which requires that no licensee
possess, use or transfer licensed material in such a manner as to cause any individual in a restricted area to receive in a calendar quarter from radioactive material and other sources of radiation a total occupational dose in excess of the limits set forth therein.

Specifically, a

contractor technician and a chemistry technician retrieved a filter (sample medium) that had been collecting radioactive material from the reactor coolant via a sampling rig located at the chemistry sampling station; however, prior to the sampling rig being dissassembled and the sample medium being handled, a radiation survey was not made to determine the levels of radiation emanating from the sample medium.

B.

10 CFR 19. 12 requires, in part, that all individuals working in or frequenting any portion of a restricted area be kept informed of radiation in such portions of the restricted area and be instructed in precautions or procedures to minimize exposure to radioactive materials.

Contrary to the above, on August 31,

1989, two individuals working in a restricted area (a contractor technician and a chemistry technician who were collecting a sample from a sampling rig located at the chemistry sampling station) were not adequately instructed in precautions or procedures to minimize exposure to radioactive materials.

Specifically, the individuals were not informed that the sample being collected was a

different type of sample from that which was normally collected (and as

such, would exhibit significant contact radiation dose rates),

nor were the individuals provided any special instructions, precautions, procedures or guidance to minimize their radiation exposure during collection of the sample.

8'Pi i080474 89i iOi PDR ADOCK 05000388 G

OFFICIAL RECORD COPY SUSQUEHANNA " 0005.0.0 11/01/89

Notice of Viol ati on C.

Technical Specification

6. 11 (Radiation Protection Program) requires that procedures for personnel radiation protection be 'prepared consistent with the requirements of 10 CFR Part 20 and be approved, maintained and adhered to for all operations involving personnel radiation exposure.

Section 4.10 of Radiation Protection Procedure A0-00-705, Revision 12 (Access Control and Radiation Work Permit System),

dated March 16,

1989, states that it is the responsibility of each radiation worker to under-stand and comply with all health physics access control and radiation work permit (RWP) requir'ements.

Signature on the RWP sign-in sheet indi-cates knowledge of the radiological conditions in the work area and the requirements of the RWP.

RWP No.89-452, (Obtain Chemistry

Samples, Analyze Samples in the Hot Chemistry Lab and Perform Sample Preparation as Necessary),

dated July 31, 1989, required individuals to (1) wear a lab coat, surgeon' gloves and cotton glove liners when sampling radioactive systems; (2) possess a survey meter to measure the radiation dose rate of samples prior to transport and to be used while transporting samples measuring 100 mR/hr or greater; (3) possess a shielding pig to transport samples measuring 100 mR/hour or greater on the outside of the sample container; and (4) obtain or provide constant health physics coverage when transpor-ting samples with 100 mR per hour or greater on the outside of the sample transport container.

Contrary to the above, on August 31,

1989, a contractor technician and chemistry technician, who had signed the sign-in sheet for RWP 89-452, collected a radioactive sample under the authority and requirements of RWP No.89-452 without complying with the RWP requirements, as evidenced by the following examples:

1.

the contractor technician who collected the sample did not wear a

lab coat and cotton glove liners while collecting the sample; 2.

although the sample was, subsequently determined to have a contact radiation dose rate of more than 100 mR/hr (600 mR/hr),

a survey meter was not obtained and used to determine the dose rate on the sample either prior to, or during transport of the sample; 3.

although the sample container had a radiation dose rate of more than 100 mR/hr (600 mR/hr) on the outside of the sample container, a

shielding pig was not used to transport the sample; and although the sample transport container had a radiation dose rate of more than 100 mR/hr on the outside, constant health physics coverage was not provided during the transport of the sample.

Technical Specification 6.8 (Procedures and Programs)

requires, in part, that the procedures recommended in Appendix A of Regulatory Guide 1.33,
1978, be established and implemented.

OFFICIAL RECORO COPY SUSQUEHANNA - 0006.0.0 11/01/89

Notice of Violation Section 10 of Appendix A of Regulatory Guide 1.33, 1978, specifies that chemical and radiochemical procedures be written to prescribe the nature and frequency of sampling and analyses, and should'nclude laboratory instructions and calibration of equipment.

Contrary to the above, as developed for prescribing reactor coolant using the calibrating the equipment of August 31,

1989, procedures were not the nature and frequency of the sampling of resin impregnated filter medium, nor for used.

These violations have been categorized in the aggregate as a Severity Level III problem.

(Supplement IV)

Pursuant to the provisions of 10 CFR 2.201, Pennsylvania Power and Light Company is hereby required to submit a written statement or explanation to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, with a copy to the Regional Administrator, Region I within 30 days of the date of this Notice.

This reply should be clearly marked as a "Reply to a Notice of Violation" and should include for each alleged violation:

( 1) admission or denial of the alleged violation, (2) the reasons for the violation if

admitted, (3) the corrective steps that have been taken and the results
achieved, (4) the corrective steps that will be taken to avoid further violations, and (5) the date when full compliance will be achieved.

If an adequate reply is not received within the time specified in this Notice, an order may be issued to show cause why the license should not be modified, suspended, or revoked or why such other action as may be proper should not be taken.

Consideration may be given to extending the response time for good cause shown.

FOR THE NUCLEAR REGULATORY COMMISSION Orf~i~al Steel Bp'.'JS S'LL William T. Russell Regional Administrator Dated ag King of Prussia, Pennsylvania this /P-day of November 1989 OFFICIAL RECORD COPY SUSQUEHANNA 0007.0.0 11/01/89