Summary of 850515 Meeting W/Util Re Implementation of Fire Protection Program & 850318-21 Site Visit.List of Meeting Attendees Encl
ML17156A285
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 05/20/1985
From: Campagnone M
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8506040581
Download: ML17156A285 (6)


Text

Docket No.:

50-387/388 l@Y 20

$986 FACILITY:

Susquehanna Steam Electric Station Units 1 and 2 (SSES)

LICENSEE:

Pennsylvania Power and Light Company (PP&L)

SUBJECT:

SUMMARY

OF MAY 15, 1985 MEETING ON THE IMPLEMENTATION OF THE SUSQUEHANNA FIRE PROTECTION PROGRAM On May 15, 1985 representatives of the NRC staff met with representatives of the Pennsylvania Power and Light Company to further discuss the results of the March 18-21, 1985 NRR site visit and the" April 18, 1985 letter from T.

M. Novak (NRC) to N.

W. Curtis (PP&L).

This meeting was held with the licensee in an effort to support the licensee's commitment in the April 23, 1985 Fire Protection meeting in which PP&L committed to respond formally to the staffs'oncerns.

A list of attendees'is enclosed.

Enclosure:

As stated cc:

See next page DISTRIBUTION.

NRC PDR Local PDR PRC System NSIC LB82 Reading OELD RButler MCampa none EHylto Ferguson BLeFave DKubicki F

M. J.

Campagnone, Project Manager Licensing Branch No.

2 Division of Licensing Ca 5/

5 LBk'2/DL MRButler 05////85 850b04058i 850520 PDR ADOCK 05000387~

F'DR I

1

~ v Docket No.:

50-387/388

&N 2 0 f985 FACILITY:

Susquehanna Steam Electric Station Units 1 and 2

(SSES)

LICENSEE:

Pennsylvania Power and Light Company (PPIntL)

SUBJECT:

SUMMARY

OF MAY 15, 1985 MEETING ON THE IMPLEMENTATION OF THE SUSQUEHANNA FIRE PROTECTION PROGRAM On May'l5, 1985 representatives of the NRC staff met with representatives of the Pennsylvania Power and Light Company to further discuss the results of the March 18-21, 1985 NRR site visit and the April 18, 1985 letter from T. M. Novak (NRC) to N. tl. Curtis (PPSL).

This meeting was held with the licensee in an effort to support the licensee's commitment in the April 23, 1985 Fire Protection meeting in which PPIlL committed to respond formally to the staffs'oncerns.

A list of attendees is enclosed.

Enclosure:

As stated cc:

See next page DISTRIBUTION

~Fi NRC PDR Local PDR PRC System NSIC LB82 Reading OELD RButler

'Campanone EHylto Ferguson BLeFave DKubicki M. J.

Campagnone, Project Manager Licensing Branch No.

2 Division of Licensing Ca 5/

LBd2/DL hRButler 05////85

yPR RECyCCg

~

y4 ~

0~A0 O$

/J +>>*++

UNITED STATES NUCLEAR R EGULATORY COMMISSION WASHINGTON, D. C. 20555 o'-7 80 ax.~

Docket No.:

50-387/388 FACILITY:

Susquehanna Steam Electric Station Units 1 and 2

(SSES)

LICENSEE:

Pennsylvania Power and Light Company (PP&L)

SUBJECT:

SUtiMARY OF MAY 15, 1985 MEETING ON ThE IMPLEMENTATION OF THE SUS(UEHANNA FIRE PROTECTION PROGRAM On May 15, 1985 representatives of the NRC staff met with representatives of the Pennsylvania Power and Light Company to further discuss the results of the March 18-21, 1985 NRR site visit and the April 18, 1985 letter from T.

M. Novak (NRC) to N. H. Curtis (PPSL).

This meeting was held with the licensee in an effort to support the licensee's commitment in the April 23, 1985 Fire Protection meeting in which PPSL committed to respond formally to the staffs'oncerns.

A list of attendees is enclosed.

Enclosure:

As stated cc:

See next page

'Np. c M. J.

Campagnone, Project Manager Licensing Branch No.

2 Division of Licensing

Encl osure ATTENDEES Mari-Jo Campagnone Robert Ferguson Clif Anderson Bill LeFave Dennis Kubicki Too Gorman Don Kohn L. Steven lleed Ken Backenstoe A. 'll. Netzger C. T. Coddington ll. E. Barberich NRR/DL/LBd2 NRR/DE/C!1EB Region I NRR/DS I/ASB NRR/DE/CMEB PP8L/NEP/Civil PPSL/NPE/Fire Prot.

PPGL/NEP/Sys.

Eng.

PPSL/NEP/Electrical PPSL/NEP/Mgr.

Nuc. Design PPGL/Licensing PPGL/Licensing

Mr. Norman W. Curtis Pennsylvania Power

& Light Company Susquehanna Steam Electric Station Unit 1

& 2 cc:

Jay Silberg, Esq; Shaw, Pittman, Potts,

& Trowbridge 1800 M Street, N.

W.

Washington, D.C.

20036 Edward M. Nagel, Esq.

General Counsel and Secretary Pennsylvania Power

& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Mr. William E. Barberich Manager-Nuclear Licensing Pennsylvania Power

& Light Company 2 North Ninth Street Allentown, Pennsylvania 18101 Mr. R. Jacobs Resident Inspector P.O.

Box 52 Shickshinny, Pennsylvania 18655 Mr. E. B. Poser Project Engineer Bechtel Power Corporation P. 0.

Box 3965 San Francisco, California 94119 Mr. Thomas M. Gerusky, Director Bureau of Radiation Protection Resources Commonwealth of Pennsylvania P. 0.

BOx 2063 Harrisburg, Pennsyl vani a 17120 Mr. N. D. Weiss, Project Manager Maile Code 391 General Electric Company 175 Curtner Avenue San Jose, California 95125 Robert W. Alder, Esquire Office of Attorney General P.O.

Box 2357 Harrisburg, Pennsyl vani a 17120 Mr. William Matson Allegheny Elec. Coorperative, Inc.

212 Locust Street P. 0.

Box 1266 Harri sburg, PA 17108-1266 Mr. Anthony J. Pietrofitta, General Manager Power Production Engineering and Construction Atlantic Electric 1199 Black Horse Pike Pleasantville, NJ 08232 Mr. Thomas E. Murley U.S.

NRC, Region I 631 Park Avenue King of Prussia, Pennsylvania 19406