ML17152A405

From kanterella
Jump to navigation Jump to search
Registration of Use of Cask to Store Spent Fuel
ML17152A405
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 06/01/2017
From: Bono S
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
Download: ML17152A405 (2)


Text

Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 June1,2017 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 10 CFR 72.4 10 CFR 72.212 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, 50-296, and 72-052

Subject:

Registration of Use of Cask to Store Spent Fuel In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 72.212, "Conditions of general license issued under §72.21 O," paragraph (b)(2), the Tennessee Valley Authority (TVA) is submitting the registration for the use of two spent fuel storage casks under the general license to store spent fuel at the Browns Ferry Nuclear Plant (BFN) Independent Spent Fuel Storage Installation. The initial use of the first cask listed below to store spent fuel occurred on May 8, 2017. This registration is required to be submitted to the Nuclear Regulatory Commission (NRC) within 30 days of initial use. Accordingly, this registration is due to the NRC by June 7, 2017 in accordance with 10 CFR 72.4. The registration of one additional cask, which was initially used on May 13, 2017 is also being submitted with this report.

Pursuant to 10 CFR 72.212(b)(2), TVA is providing the following cask loading information:

Licensee Name:

Licensee Address:

Reactor License Numbers:

Reactor Docket Numbers:

ISFSI Docket Number:

Tennessee Valley Authority Post Office Box 2000 Decatur, Alabama 35609-2000 DPR-33, DPR-52, and DPR-68 50-259, 50-260, 50-296 72-052

U.S. Nuclear Regulatory Commission Page 2 June1, 201 7 Responsible Individual:

Cask Certificate Number:

Cask Model Number:

Michael W. Oliver Site Licensing Manager, Browns Ferry Nuclear Plant 1032, Amendment 0, Revision 1 Holtec International, HI-STORM FW MPC Storage System For the cask system placed in service on May 8. 2017:

Cask Identification Numbers Multi-Purpose Canister Type89, SerialNo. 028 Overpack Serial No. 060 For the cask system placed in service on May 13. 2017:

Cask Identification Numbers Multi-Purpose Canister Type 89, Serial No. 029 Overpack Serial No. 061 There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact M.W. Oliver, Nuclear Site Licensing Manager, at (256) 729-787 4.

Re('\\ct~\\\\

\\\\~'0"

,/(9~

S. M. Bono Vice President cc: NRC Regional Administrator - Region II