Updates 800403 Analysis of Fuel Requirements for Tarapur I & Ii.Analysis Is Based on More Detailed & Current Info. Provides Discussion,Conclusions,Refueling Schedule & Projected Operating Schedule for Reactor.Gs Bedi Ltr Encl
ML17146B331
Person / Time
Site:
(XSNM-1222, XSNM-1379)
Issue date: 01/16/1979
From: Pedersen K
NRC OFFICE OF POLICY EVALUATIONS (OPE)
To: Gilinsky V, Hendrie J, Kennedy R
NRC COMMISSION (OCM)
Shared Package
ML17146B332 List:
References
FOIA-80-336 NUDOCS 8007310247
Download: ML17146B331 (9)


Text

ALL POWER REACTOR LICENSEES Docket No. 50-348 farley Unit 1

Docket No. 50-313 Arkansas Unit 1

Docket No. 50-368 Arkansas Unit 2 Docket No. 50-317 Calvert Cliffs Unit l.

Docket No. 50-318 Calvert Cliffs Unit 2 Docket No. 50-293 Pilgrim Unit 1

Docket No. 50-325 Brunswick Unit 1

Docket No. 50-324 Brunswick Unit 2 Docket No. 50-261 H. B. Robinson Unit 2 Docket No. 50-10" Dresden Unit 1

Docket No. 237 Dresden Unit 2 Docket No. 50-249 Dresden Unit 3 Docket No. 50-254 squad-Cities Unit 1, Docket No. 50-265 squad-Cities Unit 2'ocket No. 50-295 Zion Unit 1

Docket No. 50-304 Zion Unit 2 Docket No. 50-213 Connecticut Yankee (Haddam Neck)

Docket No. 50-3 Indian Point Unit 1

Docket No. 50-247 Indian Point 'Jnit 2

Docket 50-286 Indian Point Unit 3 Docket No. 50-155 Big Rock Point Docket No. 50-255 Palisades Docket No. 50-409 Lacrosse Docket No. 50-269 Oconee Unit 1

Docket No. 50-270 Oconee Unit 2 Docket No. 50-287 Oconee Unit 3 Docket No. 50-334 Beaver Valley Unit 1

Docket No. 50-302 Crystal River 3

Docket No. 50-335 St. Lucie Unit 1

Docket No. 50-250 Turkey Point Unit 3 Docket No. 50-251 Turkey Point Unit 4 Docket No. 50-321

'dwin I. Hatch Unit 1

Docket No. 50-366 Edwin I. Hatch Unit 2 Docket No. 50-315 D. C.

Cook Unit 1

Docket No. 50-316 D. C.

Cook Unit 2 Docket No. 50-331 Duane Arnold Docket No. 50-219 Oyster Creek Unit 1

Docket No. 50-309 Maine Yankee Docket No. 50-289 Three Mile Island Unit 1

Docket No. 50-320 Three Mile Island Unit 2 Docket No. 50-298 Cooper Station Docket No. 50-220 Nine Mile Point Unit 1

Docket No. 50-245 Millstone Unit 1

Docket No. 50-336 Millstone Unit 2 Docket No. 50-263 Monticello Docket No. 50-282 Prairie Island Unit 1

Docket No. 50-306 Prairie Island Unit 2 Docket No..50-285 Ft. Calhoun Docket No. 50-133 Humboldt Bay Docket No. 50-277 Peach Bottom 2 Docket No. 50-278 Peach Bottom 3 Docket No. 50-344 Trojan Docket No. 50-333 FitzPatrick Docket No. 50-267 Ft. St. Vrain Docket No. 50-272 Salem Unit 1

Docket No. 50-244 R.

E. Ginna 1

Docket No. 50-312 Rancho Seco Docket No. 50-206 San Onofre 1

Docket No. 50-259 Browns Ferry Unit 1

Docket No. 50-260 Browns Ferry Unit 2 Docket No. 50-296 Browns Ferry Unit 3 Docket No. 50-346 Davis-Besse 1

Docket No. 50-271 Vermont Yankee Docket No. 50-338 North Anna 1

Docket No. 50-280 Surry Unit 1

Docket No. 50-281 Surry Unit 2 Docket No. 50-266 Point Beach Unit 1

Docket No. 50-301 Point Beach Unit 2

Docket No. 50-305 Kewaunee Docket No. 50-29 Yankee-Rowe

I 4

I

. ~rrt zt <rigP ocket o

50 508 WPPSS 4

Docket Ho. 50-397 WPPSS 1

Docket No. 50-460 WPPSS 2

Docket No. 50-513 Docket Ho. 50-509 WPPSS 3

WPPSS 5

Docket Ho.

STH 50-528 Palo Verde 1

Docket Ho.

STH 50-529 Palo Verde 2

Docket Ho.

STH 50-530 Pal Verde 3

Docket Ho.

S AN 50-553 Phipps Bend 1

Docket Ho.

STN 50-554 Phipps Bend 2

Docket No.

STN 50-566 Yellow Creek 1

Docket Ho.

STH 50-567 Yellow Creek 2

Docket Ho. 50-467 A1'iens Creek 2

Docket Ho. 50-437 Floating Nuclear Plant 1-8 Docket Ho. 50-488 Perkins 1

Docket Ho. 50-489 Perkins 2

Docket Ho.

STN, 50-556 Black Fox 1

Docket No.

STH 50-557 Black Fox 2 Docket No. 50-514 Pebble Springs 1

Docket Ho. 50-515 Pebble Springs 2

Docket Ho. 50-522 Skagit 1

Docket No. '50-523 Skagit 2

Docket Ho. 50-471 Pilgrim 2 Cocket Ho. 50-412 Beaver Val 1 ey 2

Docket Ho. 50-413 Catawba 1

Oocket.Ho.

50-414 Catawba 2

Docket Ho. 50-322 Shoreham Docket Ho. 50-275 Diablo Canyon 1

Docket No. 50-323 Diablo Canyon 2

Docket Ho. 50-461 Clinton, 1 II Docket No. 50-462 Clinton 2 Docket No. 50-416 Grand Gulf 1

Docket No. 50-417 Grand Gulf 2 Docket No, 50-354 Hope Creek 1

Docket No. 50-355 Hope Creek 2

Docket Ho. 50-311 Salem 2

Docket No. 50-458 Riverbend 1

Docket Ho. 50-459 Riverbend 2

Docket Ho. 50-361 San Onofre 2

Docket No. 50-362 San Onofre 3

Docket No. 50-329 Midland 1

Docket No. 50-330 Midland 2 Docket Ho. 50-358 Zinger 1

Docket No. 50-382 Waterford 3

Docket Ho. 50-390 Watts Bar 1

Docket No. 50-391 Watts Bar 2

Docket Ho. 50-424 Vogtle 1

Docket Ho. 50-425 Vogtle 2 Docket Ho. 50-483 Callaway 1

Docket Ho. 50-340 Seabrook Docket No. 50-327 Sequoyah 1

Docket Ho. 50-328 Sequoyah 2

Docket STH 50-498 So.

Texas 1

Docket STN 50-499 So. Texas 2

Docket No. 50-395 Summer 1

Docket No. 50-440 Perry 1

Docket No. 50-441 Perry 2

. Docket No. 50-352 Limerick 1

Docket No. 50-353 Limerick 2 Docket STN 50-518 Hartsville 1

Docket STN 50-519 Hartsville 2 Docket STN 50-520 Hartsville 3

Docket STN 50-521 Hartsvil le 4 Docket No. 50-363 Forked River 1

'ocket 50-341 Fermi 2 Docket No. 50-364 Farley 2 Docket No. 50-445 Comanche Peak 1

Docket No. 50-446 Comanche Peak 2

Docket No. 50-491 Cherokee 1:

Docket No. 50-492 Cherokee 2

Docket No. 50-493 Cherokee 3

Docket No. 50-486 Callaway 2

Docket No. 50-339 North Anna 2

Docket No. 50-454 Byron 1

Docket No. 50-455 Byron 2

Docket No. 50-456 Braidwood 1

Docket Ho. 50-457 Braidwood 2

Docke. No. 50-367 Bail ly Docket Ho. 50-410 Nine. Mile Point 2

Docket No. 50-546 Marble H>11 1

Docket No. 50-547 Marble Hill 2 Docket No. 50-400 Shearon Harris 1

Docket No. 50-401 Shearon Harris 2

Docket No. 50-402.

Shearon Harris 3

Docket No. 50-403 Shearon Harris 4

Docket No. 50-373 LaSalle 1

Docket No. 50-374 LaSalle 2

Docket No. 50-389 St. Lucie 2 Docket No. 50-482 Wolf Creek Docket No. 50-423 Millstone 3 Docket Ho. 50-438 Bellefonte 1

Docket No. 50-439 Bellefonte 2 Docket Ho. 50-369 McGuire 1

Docket Ho. 50-370 McGuire 2 Docket No. 50-387 Susquehanna 1

Docket No. 50-388 Susquehanna 2

I 0

r Y

'I lk L

pS REOg C~

~4 0

%p*y4 UNITED STATES CLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 JUN 2 >

1980 8MKN08Y DOIKP FLI~ gop~

Dr. Hancock Chau, Chairman Mark II Owners Group Nuclear Licensing Divisions Long Island Lighting Company 175 E. Old Country Road Hicksville, New York 11801

Dear Dr,

Chau:

Attached is a copy of the staff's evaluation of the GE topical report, "Technical Bases for the Use of the Square-Root-of-the-Sum-of-Squares (SRSS)

Method for Combining Dynamic Loads for Mark II Plants",

NEDE-24010-P and Supplements 1 through 3.

This evaluation concludes that the SRSS method is acceptable for the design and assessment of mechanical

systems, components, and supports for Nark II plant=subject to certain constraints related to the seismic loading level and the containment structure.

The staff positions included in this evaluation report extend beyond those in our previous report "Methodology for combining Dynamics Response",

NUREG-0484 and Supplement 1 to that report.

The primary purpose of this evaluation report is to address the acceptability of SRSS based on NEDE-24010-P without additional justification for Mark II plants.

The staff is continuing its work on response combination methodology beyond that addressed in NUREG-0484, Supplement 1 to NUREG-0484 and, this evaluation report.

Phase 2B of Task Action Plan B-6 will investigate the validity of several proposed "loading level" criteria.

'kr f

k

-.Dr. Hhncock Chau JUN 25

>BOO Should you have any questions regarding this letter, contact R. Mattu (301) 492-9475.

Sincerely,

Enclosure:

Technical Bases for the Use of the SRSS Method for Combining Dynamic Loads for Mark II

Plants, NEDE-24010-P and Supplements 1 through 3

ector chnology C.'~g Roger J.

Ma