Amend 28 to License NPF-22,revising Tech Specs to Include Operational Control on Newly Installed Containment Isolation Valves
ML17146A513
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 08/27/1986
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17146A514 List:
References
NUDOCS 8609040392
Download: ML17146A513 (8)


Text

~pa AEQUI c>

0

~>> +i i4 UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 PENNSYLVANIA POWER 8

LIGHT COMPANY ALLEGHENY ELECTRIC COOPERATIVE INC.

DOCKET NO. 50-388 SUSOLIEHANHA STEAM ELECTRIC STATION UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment Ho.

License No. NPF-22 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for the amendment filed by the Pennsylvania Power A

Light Company, dated April 4, 1986, complies with the standards and reauirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the regulations of the ComIission; C.

There is reasonable assurance:

(i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment and paragraph 2.C.(2) of the Facilitv Operating License Ho. NPF-22 is hereby amended to read as follows:

(2)

Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 28 and the Environmental Protection Plan con-tained in Appendix B, are hereby incorporated in the license.

PPSL shall operate the facility in accordance with the Technical Specifica-tions and the Environmental Protection Plan.

PDR PD 92 860827 8609040 ADOCK 05000388 PDR 3.

This amendment is effective upon start-up following the Unit 2 first refueling outage.

FOR THE NUCLEAR REGULATORY COMMISSION

Enclosure:

Changes to the Technical Specifications Date of Issuance:

August 27, lgB6 Elinor G. Adensam, Director BWR Project Direc~orate No.

3 Division of BWR Licensing

ATTACHMENT TO LICENSF.

AMENDMENT NO.

FACJLJTY OPERATINA LICFNSE NO.

NPF-22 DOCKET NO. 50-388 Replace the followino paces of the Apoendix "A" Technical Specifications with enclosed oaaes.

The revised pages are identified by Amendment number and contain vertical lines indicatina the area of chanoe.

The correspondina overleaf pages are also provided to maintain document completeness.

REMOVE 3/4 6-21 3/4 6-92 3/4 8-33 3/4 8-34 INSERT 3/~

6-21

< over 1 eaf )

3/4 6-P2 3/4 8-33 (overleaf) 3/4 8-34

TABLE 3. 6. 3-1 (Continued)

PRIMARY CONTAINMENT ISOLATION VALVES VALVE FUNCTION AND NUMBER HAXIHUM ISOLATION TIME Seconds ISOLATION Automatic Isolation Valves (Continued)

Containment Atmos here Sam le SV"25734 A,B SV-25736 A

SV"25736 8

SV-25740 A,B SV-25742 A,B SV-25750 A,B SV-,25752 A,B SV-25774 A,B SV-25776 A

SV-25776 8

SV"25780 A,B SV-25782 A,B Nitro en Makeu SV-25737 SV-25738 SV-25767 SV-25789 Reactor Coolant Sam le HV-243F019 HV-243F020 Li uid Radwaste HV-26108 A1, A2 HV"26116 Al,A2 RHR -

Su ression Pool

~/

c)

HV-251F011 A, B HV-251F028 A, B CS Test HV-252F015 A,B HPCI Suction HV-255F042 SUS(UEHANNA - UNIT 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15 15 23 90 60 90 3/4 6-21 B,Y B,Y B,Y B,Y B,Y B,Y B,Y B,Y B,Y B,Y B,Y B,Y',Y,R B,Y,R B,Y,R B,Y,R B,C B,C B,Z B,Z X,Z X,Z X,Z L,LB Amendment No. 2

TABLE 3.6.3-1 (Continued)

PRIMARY CONTAINMENT ISOLATION VALVES YALYE FUNCTION AND NUMBER Automatic Isolation Valves (Continued)

Su ression Pool Cleanu HV-25766 HV-25768 MAXIMUM ISOLATION TIME Seconds 35 30

" I SOL'ATION',Z;,

A,Z.

HPCI Yacuum Breaker HV-255F075 HV-255F079 15 15 LB,Z; '...

LB,Z:.,

RCIC Yacuum Breaker HV-249F062 HV-249F084 TIP Ball Yalyes (d 10 10 KB,Z.

KB,Z:

C51-J004 A,B,C,D,E A,Z b.

Manual Isolation Valves MSIV-LCS Bleed Valve HV-239F001 B,F,K)P Feedwater (e')

HV-241F032 A, B RWCU Return HV-24182 A, 8 RCIC In'ection HY-249F013 2-49-020 SUS(UEHANNA - UNIT 2 3/4 6-22 Amendment No.

28

TABLE 3.8.4.2-1 (Continued)

MOTOR-OPERATED VALVES THERMAL OYERLOAD PROTECTION VALVE NUMBER HV-Ell-2F0288 HV-El1"2F0478 HV-El1-2F 0168 HV-Ell"2F 0038 HV-Ell-2F0178 HV-E21-2F0318 HV-E21-2F 0018 HV-Ell-2F1038 HV-Ell-2F0758 HV-Ell-2F0738 HV-Ell-2F006D HV-Ell-2F004D HV-Ell-2F0248 HV-E21-2F 0158 HV-E21-2F0048 HV-E21-2FOOSB HV-E32-2F 001K HV-E32-2F 002K HV-E32-2F003K HV-E32-2F001P HV-E32-2F002P HV"E32-2F003P HV-E32-2F 0018 HV"E32-2F0028 HV-E32-2F0038 HV-E32" 2F001F HV-E32-2F002F HV-E32-2F003F HV-E32-2F006 HV-E32-2F007 HV-E32"2FOOS HV-E32-2F009 HV-E51" 2F045 HV-E51" 2F012 HV-E51-2F013 HV-25012 HY-E51-2F046 HV-E51-2FOOB HV-E51-2F031 HV-E51-2F010 SYSTEM(S)

AFFECTED RHR RHR RHR RHR RHR CS CS RHR RHRSM RHRSW RHR RHR RHR CS CS CS MSIY MSIY MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV MSIV RCI C RCIC RCIC RCIC RCIC RCIC RCIC RCIC SUSQUEHANNA " UNIT 2 3/4 8-33

TABLE 3.8.4.2-1 (Continued)

MOTOR-OPERATED VALVES THERMAL OVERLOAD PROTECTION VALVE NUMBER HV-E51-2F 019 HV-E51-2F060 HV-E51-2F059 HV-E51-2F022 HV-E51-2F062 HV-E41-2F012 HV-E41-2F001 HV-E41" 2F011 HV-E41-2F006 HV-E41-2F079 HV-E41-2F 059 HV-E41-2F004 HV-E41-2F 003 HV-E41-2F042 HV-E41-2F075 HV-E41"2F008 HV-E41-2F007 HV-E41-2 F066 HV-G33-2F004 HV-B21-2F019 HV-E11-2F 008 HV-E11-2F023 HV-E11-2F049 HV-B31-2F032A HV-B31-2F032B HV-B31-2F031A HV-B31-2F031B HV-24182A HV-24182B SYSTEM(S):

AFFECTED..

RCIC RCIC RCIC RCIC RCIC HPCI HPCI HPCI HPCI HPCI HPCI:

HPCI-HPCI

'PCI.

HPC.I:,

HPCI HPCI.

HPCI RWCU NSSS RHR RHR RHR Rx Recirc

'x Recirc Rx Recirc Rx Recirc RMCU RWCU SUSQUEHANNA - UNIT 2 3/4 8-34 Amendment No. 28