Pe
~
~pS AE0y 0
0
~+**+
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 PENNSYLVANIA POWER AND LIGHT COMPANY LL NY L
R, N
DOCKET N
. 50-38 SUSQUEHANNA S E
L ION, UNIT 1 MENDM NT T F CILITY PERATING L
C N
Amendment No. 18 License No. NPF-14 1.
The Nuclear Regulatory Commission (the Commission or the NRC) having found that:
A.
The application for amendment filed by the Pennsylvania Power and Light Company, dated October 7, 1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the regulations of the Comnission; C.
D.
There is reasonable assurance:
(i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities w'ill be conducted in compliance with the Comission's regulations; r
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of'he ComIission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specif-ications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of the Facility Operating License No. NPF-14 is hereby amended to read as follows:
(2)
Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 18
, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.
PP&L shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
8312120478 831118 PDR ADOCK 05000387 P
PDR 3.
This amendment was effective as of October 7, 1983.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical Specifications P><etaac 6<<< b>.
A. Schwencer, Chief Licensing Branch No.
2 Division of Licensing Date of Issuance:
November'8, 1983 DL:LB8 M
RLPerch:pt
)0/l4/83 D
/LA E
lton I /j /83 0 :LB82/BC OELD'Schwencer ovak l6/g/83 9$/[
83 l +83
g l,l II J
~
r~>m>
W q.<< ~
$QI'I, lk h
,il )
ll i f,
1 +,I
't l'
I
)
g
'I I
II Q
~ ~l
ATTACHMENT TO LICENSE AMENDMENT NO.
F L
R N
N.NP-Replace the following pages of the Appendix "A" Technical Specifications with enclosed pages.
The revised pages are identified'y Amendment number and contain vertical lines indicating the area of change.
REMOVE 3/4 6-19 3/4 6-20 INSERT 3/4 6-19 3/4 6-20
TABLE 3.6.3-1 PRIMARY CONTAINMENT ISOLATION VALVES VALVE FUNCTION AND NUMBER a.
Automatic Isolation Valves (b)
MSIV HV-141F022 A,B,C,D HV-141F028 A,B, C, D MSL Drain HV"141F016 HY-141F019 RCIC Steam Su 1
HV"149F007,')
HV-149F008(')
HY-149F088 HPCI Steam Su l
HV-155F002 HV-155F003(')
HV-155F100 RHR - Shutdown Coolin Suction HV-151F008 HV-151F009 RHR - Shutdown Coolin Return/
MAXIMUM ISOLATION TIME Seconds 5
5 10 10 20 20 3
50 50 3
52 52 ISOLATION( )
SIGNAL(s B,C,D,E,P,UA B,C,D,E,P,UA B,C,D,E,P,UA M,UB M,UB HV-151F122 A,B RWCU Suction HV-144F001 HV-144F004 RHR - Reactor Vessel Head S ra HV"151F022 HV-151F023 30 30 30 20 Z
B,J,W M)UB,Z M,UB,Z SUSQUEHANNA " UNIT 1 I
3/4 6-19 Amendment No
TABLE 3. 6. 3-1 (Continued)
PRIMARY CONTAINMENT ISOLATION VALVES MAXIMUM ISOLATION TIME VALVE FUNCTION AND NUMBER Seconds Automatic Isolation Valves (Continued)
Containment Instrument Gas ISOLATION( )
SIGNAL s HV-12603 SV-12605 SV"12651 SV-.12661 SV"12671 RBCCW HV-.11313 HV-11314 HV"11345 HV"11346 Containment Purge HV-15703 HV"15704 HV-15705 HV-15711 HV"15713 HV-15714 HV"15721 HV-15722 HV"15723 HV-15724 HV-15725 RHR - Or ell S ra (~)
HV"151F016 A,B RB Chilled Water HV-18781 A1,A2,B1,B2 HV-18782 A1,A2, B1, B2 HV"18791 A1,A2,B1, B2 HV-18792 Al,A2, B1, B2 20 N/A N/A N/A N/A 30 30 30 30 19 19 5
5 30 30 6
30 30 19 19 90 40 6
15-4 X
X.
Y Y
Y,R Y,R Y,R Y,R Y,R Y,R Y,R Y,R Y,R Y,R Y,R X
X Y
Y SUSQUEHANNA " UNIT 1 3/4 6-20 Amendment t!g a.