APPENDIX A

'NOTICE OF'IOLATION Pennsyl vania Power and Light Company Docket No. 50-387 This refers to the inspection conducted by a representative of-the Region I (Philadelphia) office at the Susquehanna Steam Electric Station,

Berwick, Pennsylvania, of activities authorized by NRC License No.

CPPR-101.

During this inspection conducted on September 10-October 5,. 1979, the following apparent items of noncompliance were identified.

These items are infractions.

a.

10 CFR 50, Appendix B, Criterion VI, states, in part:

"These measures shall assure that documents; including changes, are reviewed for adequacy and approved for release by authorized personnel..."

-The Susquehanna PSAR Section.0.2.6,. states, in part:

"When applicable, suppliers wi.ll be required to maintain document control systems to assure that documents, including

changes, are reviewed for adequacy and approved for release by authorized per sonnel..."

The General Electric Installation and Service Engineering (GEI&SE) Nuclear guality Assurance.

Manual Section 7.7 states,'in part:

"Revised documents shall be reviewed,

approved, released, and distributed in the same manner as original documents."

Contrary to the above, as of September 19, 1979, GE, I&SE Procedure SRSE 1-12, Revision 2, had been approved for-'use without an adequate review as indicated by three instances'of failure to refer to the correct detailed welding pro-cedure,'incorrect identification of one welder qualification procedure as a

detailed welding procedure and failure to include references to two detailed welding procedures.

As a result, welding could have been performed by wel-ders who were not properly qualified.

b.

10 CFR 50, Appendix B, Criterion V, states, in part:

"Activities affecting quality will be prescribed by documented instructions, procedures or draw-ings appropriate to the circumstances."

The Susquehanna PSAR Section,D.2.5 states, in part: "Activities affecting quality will be prescribed by documented instructions, procedures or drawings appropriate to the circumstances."

Bechtel Field Procedure FP-W-l, Revision 7, Section

3. 1. 1 states, in part:

"All piping and integral...piping attachments shall be welded in accordance with the procedures specified on drawing 8856-M-198 for the applicable pipe