ML17138A695

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 790306-08
ML17138A695
Person / Time
Site: Susquehanna  
Issue date: 04/06/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML17138A692 List:
References
50-387-79-11, 50-388-79-07, 50-388-79-7, NUDOCS 7907230585
Download: ML17138A695 (1)


Text

APPENDIX A NOTICE OF VIOLATION Pennsylvania Power and Light Company Docket No. 50-387 This refers to the inspection conducted by a representative of the Region I (Philadelphia) office at the Susquehanna Steam Electric Station Unit 1, Berwick, Pennsylvania, of activities authorized by NRC License No.

CPPR-101.

During this inspection, conducted on March 6-8, 1979, the following apparent item of noncompliance was identified:

10 CFR 50, Appendix B, Criterion V, states, in part, that:

"Activities affecting quality shall be prescribed by documented instructions, procedures, or drawings...

and shall be accomplished in accordance with these instructions, procedures, or drawings."

. The Susquehanna PSAR, Appendix D, guality Assurance

Program, Paragraph D.2.5 states, in part, that:

"Activities affecting quality will be prescribed by documented instructions, procedures, or drawing appropriate to the circumstances..."

Bechtel Field Project Procedure E-8, Revision 0, states in Section

6. 3.1 that, "Aluminum conductors shall be thoroughly brushed with a fine bristle stainless steel wire brush immediately prior to installation of the conductor to remove any oxide film from the conductor strands. "

Contrary to the above, on March 7, 1979, the installation of terminations on twq 500 NCH aluminum conductors for the 250 VDC battery charger ID653B was completed without brushing with a wire brush as required.

This item is an infraction.

vaovss o UZI