UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 FEB 1 i 1979 Docket Nos.

50-387/388 MEMORANDUM FOR:

0. 'D. Parr, LWR Branch b'3, DPM morc:

SUBJECT:

PLANT NAME:

DOCKET NOS:

P.

F. Collins, Chief, Operator Licensing Branch, DPM

RESPONSE

TO REVIEW ASSIGNMENT SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1

AND 2'usquehanna Steam Electric Station 50-387/388 LICENSING STAGE:

OL BRANCH AND LPM REQUESTING ASSISTANCE:

LWR-3, S. Miner REVIEW BRANCH INVOLVED:

OLB:DPM REQUESTED COMPLETION DATE:

March 3, 1979 REVIEW STATUS:

Second Round Questions We have reviewed the additional information submitted for Sections 13.2 and 13.5 of the FSAR as Revision 4.

Based on our review, we have determined that Sections 13.2 and 13.5 should be revised, as, indicated in Attachment A, to bring the FSAR into conformance wi th previously approved submittals.

We will be available to discuss these

items,

.should the applicant desire.

(r r Operator Licensing Branch Division of Project Management cc:

D. Skovholt W. Ilaass D. Vassallo S. Miner W. Pike

Enclosure:

Attachment A

rBo3068 G~I

0

~,

~

~

P v

s< ~'(.

< ~

~ Q'>> l,j'i i,i 4

ATTACHMENT A 440.0 OPERATOR LICENSING BRANCH I

The Susquehanna Fire Safety 'Training program remains I

unacceptable.

The SSES response meets

some, but not all of the acceptance criteria required by question 441.6 of our previous submittal.

As an example, using the numbering scheme of First-Round guestion 441.6, an NRC acceptance criteria and 'SSES response is as follows:

NRC Acce ta nce Cri teri a A. 1. d i)

An identification of the,fire hazards and associated types of fires that could occur in the plant, and an identification of the location of the hazards, includ-ing areas where breathing apparatus is required, regard-less of the size of the fire.

SSES Res onse A.

1 a.

Identification of fire hazards.

Many other instances of oversimplification and material deletion exist in the applicants response.

SSES is required to meet the acceptance criteria of First-Round guestion 441.6 or provide adequate justification for deviations.

Additionally, the applicant must include the response to this question as part of FSAR Section

a 13.2.

Also, SSES.,must commit to not using the Shift Supervisor as th'e individual responsible for directing

(

ki:'he actual firi; fighting forces.

442.1 (13.5.1.3)

Figure 13.5-2, submitted by Revision 4, does not ade-quately define the "at the controls" area.

For example, an operator should not routinely enter areas behind the control panels, yet Figure 13.5-2 shows the area behind panel 1Z 651 (2Z 651) as being "at the controls".

It does not appear that an operator would have an unobstructed view of the control panels from this position.

Revise Figure 13.5-2 to indicate the surveillance area (an area where continuous attention can be given to reactor operating conditions and to the manipulations of reactor controls) and areas which may be entered by the operator at the controls to verify receipt of an annunciator alarm or initiate corrective action in the event of an emergency.

Please note that Regulatory Guide

1. 114 "Guidance on Being Operator at the Controls of a Nuclear Power Plant" provides information on this subject.