ML17128A064

From kanterella
Jump to navigation Jump to search
Independent Spent Fuel Storage Installation - Annual Radiological Environmental Operating Report for 2016
ML17128A064
Person / Time
Site: Maine Yankee
Issue date: 03/31/2017
From:
Radiation Safety & Control Services
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML17128A051 List:
References
OMY-17-016
Download: ML17128A064 (28)


Text

MAINE YANKEE INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-36 and SFGL-14 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT January - December 2016

~SGS Radiation Safety & Controi Services March 2017 Prepared by:

Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885-2468

EXECUTIVE

SUMMARY

The Maine Yankee Independent Spent Fuel Storage Installation (ISFSI) has been in operation since 2001. All fuel has been transferred into dry storage casks and placed at the Independent Spent Fuel Storage Installation. The Radiological Environmental Monitoring Program (REMP) for the Maine Yankee ISFSI located in Wiscasset, ME was continued for the period January through December 2016 in compliance with the Maine Yankee Offsite Dose Calculation Manual (ODCM).

By design, there are no liquid or gaseous effluents associated with the operation of the ISFSI. Therefore, the ODCM only requires monitoring of direct exposure from the facility. TLDs were used to measure direct gamma exposure at nine locations in the vicinity of the ISFSI and one control location 5.2 kilometers away. The results of these measurements showed no significant change in exposure rates and potential doses to members of the public during the monitoring period. The results of the monitoring performed in 2016 also show that operating the Maine Yankee ISFSI results in only a small fraction of the 40 CFR Part 190 and 10 CFR Part 72.104 direct radiation dose limit of 25 mrem/year to members of the public.

MY 2016 Annual REO Report Page 2of28

Section 1.0 2.0 3.0 3.1 3.2 3.3 4.0 5.0 5.1 5.2 6.0 TABLE OF CONTENTS INTRODUCTION............................................................................................ 6 GENERAL ISFSI AND SITE INFORMATION................................................ ?

PROGRAM DESIGN...................................................................................... 7 MONITORING ZONES........................................................................................... 7 PATHWAYS MONITORED...................................................................................... 8 DESCRIPTION OF MONITORING PROGRAM............................................................ 8 RADIOLOGICAL DATA

SUMMARY

TABLES............................................ 13 ANALYSIS OF ENVIRONMENTAL RESUL TS............................................ 27 SAMPLING PROGRAM DEVIATIONS..................................................................... 27 DIRECT RADIATION PATHWAY............................................................................ 27 l

REFERENCES............................................................................................. 28.

MY 2016 Annual REO Report Page 3of28

LIST OF TABLES 3.1 Radiological Environmental Monitoring Program..................................... 9 3.2 Radiological Environmental Monitoring Locations................................. 10 4.1 TLD Measurements by Half-Year............................................................... 14 4.2 TLD Data Summary.................................................................................... 15 4.3 Direct Dose from ISFSI Operations........................................................... 16 MY 2016 Annual REO Report Page 4of28

LIST OF FIGURES Figure 3.1 Radiological Environmental Monitoring Locations (within 0.28 km)..... 11 3.2 Direct Radiation Monitoring Locations (outside 1 km)........................... 12 4.1 Annual Dose Trend at TL-1-02.................................................................... 18 4.2 Annual Dose Trend at TL-1-04.................................................................... 19 4.3 Annual Dose Trend at TL-1-06.................................................................... 20 4.4 Annual Dose Trend at TL-1-08.................................................................... 21 4.5 Annual Dose Trend at TL.:1.10.................................................................... 22 4.6 Annual Dose Trend at TL-1-12.................................................................... 23 4.7 Annual Dose Trend at TL-1-14.................................................................... 24 4.8 Annual Dose Trend at TL-1-15.................................................................... 25 4.9 Annual Dose Trend at TL-1-16.................................................................... 26 MY 2016 Annual REO Report Page 5 of 28

1.0 INTRODUCTION

This report summarizes the findings of the Radiological Environmental Monitoring Program (REMP) conducted by Maine Yankee in the vicinity of the Independent Spent Fuel Storage Installation in Wiscasset, Maine during the calendar year 2016. It is submitted annually in compliance with Appendix A, of the Offsite Dose Calculation Manual (ODCM). The remainder of this report is organized as follows:

Section 2:

Provides a brief description of the Maine Yankee site and its environs.

Section 3:

Provides a description of the overall REMP design. Included is a summary of the requirements for REMP sampling, tables listing routine TLD monitoring locations with compass sectors and distances from the ISFSI, and maps showing the location of each of the TLD monitoring locations.

Section 4:

Provides a complete set of TLD data showing measured results (mR) and calculated doses (mrem per year). This section also provides the summarized exposure rate data in the format specified by the NRC Branch Technical Position on Environmental Monitoring (Reference 1 ).

Section 5:

Provides the results of the monitoring program. The performance of the program in meeting ODCM requirements is discussed, and the data acquired during the year is analyzed.

Section 6:

References MY 2016 Annual REO Report Page 6of28

2.0 GENERAL ISFSI AND SITE INFORMATION The Maine Yankee Independent Spent Fuel Storage Installation (ISFSI) is located in the town of Wiscasset, Lincoln County, Maine, approximately six miles northeast of Bath, Maine. The site vicinity is rural and lightly populated.

The ISFSI site is located near Bailey Point, a peninsula bounded to the east by the Back River and to the west by a shallow inlet known as Bailey Cove, both of which are part of the Montsweag Bay-Sheepscot River Estuary. Bailey point is an elongated bedrock ridge with flat or gently rolling topography rising to an average elevation of about 25 feet above sea level.

The REMP for the ISFSI began pre-operational measurements in the 4th quarter of 1999, approximately 2 years prior to the initial spent fuel transfer to the ISFSI.

The ISFSI REMP has been in continuous operation since this transfer began.

3.0 PROGRAM DESIGN The REMP for the Maine Yankee ISFSI was designed to provide assurance to regulatory agencies and the public that the station's environmental impact is known and within anticipated limits. The direct dose limit for members of the public from operation of the ISFSI is 25 mrem per year (References 3 and 4).

The detailed sampling requirements of the REMP are given in the ODCM. The sampling requirements specified in the ODCM are summarized in Table 3.1 of this report. Details of the monitored locations are shown in Table ~.2, as well as Figures 3.1 and 3.2 of this report.

3.1 Monitoring Zones The REMP is designed to allow comparison of levels of radioactivity in samples from the area possibly influenced by the ISFSI to levels found in areas not influenced by the ISFSI. The first area is called "indicator stations". The second area is called "control stations". The distinction between the two is based on relative direction from the facility and distance. Analysis of survey data from the two zones aids in determining if there is a significant difference between the two areas. It can also help in differentiating between radioactivity or radiation due to releases and that due to other fluctuations in the environment, such as seasonal variations in the natural background.

MY 2016 Annual REO Report Page 7of28

3.2 Pathways Monitored Based on the design of the ISFSI, only the direct radiation exposure pathway is monitored by the REMP. This pathway is monitored by the collection of thermoluminescent dosimeters (TLDs) which are described in more detail below.

3.3 Description of Monitoring Program 3.3.1 Direct Radiation Direct gamma radiation exposure was continuously monitored during 2016 with the use of thermoluminescent dosimeters (TLDs). At each monitoring location, these TLDs are sealed in plastic bags and attached to an object such as a tree, fence or utility pole. The TLDs are posted and retrieved on a semi-annual basis.

All TLDs are provided and processed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified vendor. The TLDs are placed at various locations around the ISFSI. Table 3.2 lists the Station ID Codes, distances and direction of the TLDs from the ISFSI.

3.3.2 Special Monitoring Special samples can be taken that are not required in the ODCM. No special samples were collected in 2016.

MY 2016 Annual REO Report Page 8 of 28

Table 3.1 Radiological Environmental Monitoring Program Exposure Collection Analysis Pathway Number of Routine and/or Collection Analysis Analysis Sample Sample Sampling Frequency Type Frequency Media Locations Mode Direct Total Continuous Semi-Gamma Semi-Radiation Locations: 10 annual dose annual (TLD)

(9 around perimeter of the site and 1 offsite control location)

MY 2016 Annual REO Report Page 9of28

Table 3.2 Radiological Environmental Monitoring Locations Station Distance Direction Station Description Zone

From ISFSI TL-1-02 Spent Fuel Storage (I)**

1

< 0.28 N

TL-1-04 Spent Fuel Storage (I)**

1

< 0.28 NE TL-1-06 Spent Fuel Storage (I)**

1

< 0.28 E

TL-1-08 Spent Fuel Storage (I)**

1

< 0.28 SE TL-1-10 Spent Fuel Storage (I)**

1

< 0.28 s

TL-1-12 Spent Fuel Storage (I)**

1

<0.28 SW TL-1-14 Spent Fuel Storage (I)**

1

< 0.28 w

TL-1-15 Spent Fuel Storage (I)**

1

< 0.28 WNW TL-1-16 Spent Fuel Storage (I)**

1

< 0.28 NW TL-0-36 Wiscasset Fire Station (0) 2 5.2 NW

  • 2 = Control TLD; 1 = Indicator TLD
    • I = Inner Ring TLD; 0 = Outer Ring TLD MY 2016 Annual REO Report Page 10 of 28

Figure 3.1 Radiological Environmental Monitoring Locations (within 0.28 km)

MONTSWEAG Af..~

.9~

LITTLE OAK ISLAND llalne Y<Ylkee ISFSI SITE Pion with 25 nrenVyr Bcunda-y Based on 8760 Hour Annual Occuponcy MY 2016 Annual REO Report M

CRA.PHlC SCALE:

FT.~..,,

FILE:

n.o-u11:-F1c;-3-1-ui1~

Page 11of28

Figure 3.2 Direct Radiation Monitoring Locations (outside 1 km)

MY 2016 Annual REO Report Page 12 of 28

4.0 RADIOLOGICAL DATA

SUMMARY

TABLES This section summarizes the analytical results of the environmental samples, which were collected during the monitoring period.

Data from direct radiation measurements made by TLDs are presented in Table 4.1.

The summarized TLD measurements, shown in Table 4.2, are presented in a format similar to that prescribed in the NRC's Radiological Assessment Branch Technical Position on Environmental Monitoring (Reference 1 ).

Table 4.3 presents the estimated direct dose from ISFSI operations as determined by TLD data shown in Table 4.1.

MY 2016 Annual REO Report Page 13 of 28

Table 4.1 TLD Measurements by Half-Year (mR)

Station ID Direction 1st Half-Year 2nd Half-Year TL-1-02 N

38 52 TL-1-04 NE 34 46 TL-1-06 E

55 67 TL-1-08 SE 41 50 TL-1-10 s

47 53 TL-1-12 SW 40 55 TL-1-14 w

44 56 TL-1-15 WNW 44 62 TL-1-16 NW 49 54 TL-0-36 Control 38 50 TL-0-36a Control Backup 37 50 MY 2016 Annual REO Report Page 14 of 28


~

Indicator TLDs Mean (Range)

No. Measurements)*

49.3 (34-67)

(18)

Table 4.2 TLD Data Summary (mR)

Control TLDs Indicator Station With Highest Mean Mean (Range)

Station #

No. Measurements

  • 43.8 TL-1-06 (37 -50 (4

Mean (Range)

No. Measurements

  • 61.0 (55-67 (2
  • Each "measurement" is based on semi-annual readings.

MY 2016 Annual REO Report Page 15 of 28

Station ID TL-1-02 TL-1-04 TL-1-06 TL-1-08 TL-1-10 TL-1-12 TL-1-14 TL-1-15 TL-1-16 Note:

Table 4.3 Direct Dose from ISFSI Operations (mrem) 1st Half-Year 2nd Half-Year Net TLD Calculated NetTLD Calculated Result Dose Result Dose 0.50 0.02 2.00 0.07 0.00 0.00 0.00 0.00 17.50 0.65 17.00 0.63 3.50 0.13 0.00 0.00 9.50 0.35 3.00 0.11 2.50 0.09 5.00 0.19 6.50 0.24 6.00 0.22 6.50 0.24 12.00 0.45 11.50 0.43 4.00 0.15 Max Dose=>

Annual Dose 0.09 0.00 1.28 0.13 0.46 0.28 d.46 0.69 0.58 1.28 Doses based on a 162.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> occupancy in both of the first and second half-years.

MY 2016 Annual REO Report Page 16 of 28

Radiological Environmental Monitoring Program Trending A series of graphs of REMP TLD data have been developed and are provided for trending purposes. The trending is developed for each of the indicator locations based on the annual historical doses. The trending is provided for the "real members of the public" based on the guidance provided in the ODCM. The analysis of the trends and associated data shows very small annual doses with minor fluctuations in the data. In this report, the uncorrected TLD results have been summarized and the annual doses, calculated for "real members of the public" based upon guidance in the ODCM, have been plotted for trending.

MY 2016 Annual REO Report Page 17 of 28

Location TL-1-02 Figure 4.1 Annual Dose Trend at TL-1-02 TL-1-02 30.00...---------------------

25.00 +---------------------

  • ~ 20.00 -

~ 15.00 +---------------------

...,._n-1-02 E 10.00

-limit 5.00 0.17 0.55 0.08 0.30 0.00 0.14 0.07 0.00 0.04 0.09 0.00

~

A A

~

T 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Vear Annual Doses {mrem/yr) 2007 2008 2009 2010 2011 2012 2013 2014 2015 0.17 0.55 0.08 0.30 0.00 0.14 0.07 0.00 0.04 2016 0.09 MY 2016 Annual REO Report Page 18 of 28

Location TL-1-04 Figure 4.2 Annual Dose Trend at TL-1-04 TL-1-04 30.00...----------------------

25.00 --------------------

.. 20.00 ---------------------

<: 5 15.00 +---------------------

-+-TL-1-04 E 10.00 +---------------------1-im_i_t 5.00 -------lt-.t"ii--------------

2007 0.01 0.01 0.12 0.10 0.09 0.13 0.06 0.00 0.00 0.00 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses (mrem/yr) 2008 2009 2010 2011 2012 2013 2014 2015 0.12 0.10 1.45 0.09 0.13 0.06 0.00 0.00 2016 0.00 MY 2016 Annual REO Report Page 19 of 28

Location TL-1-06 Figure 4.3 Annual Dose Trend at TL-1-06 TL-1-06 30.00....--------------------

25.00 -+---------------------

... 20.00 -+---------------------

<: 5 15.00 -!---------------'--------

-t-Tl-1-06 E 10.00 --------------------li-m-it-2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses (mrem/yr) 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 1.21 1.68 2.04 1.65 1.74 1.65 1.15 0.99 1.30 1.28 MY 2016 Annual REO Report Page 20of28

Figure 4.4 Annual Dose Trend at TL-1-08 TL-1-08 30.00...----------------------

25.00 -f---------------------

.. 20.00 +----------------------

~

~ 15.00 -t---------------------

E 10.00

..,._TL-1-08

-limit 5.00 0.35 0.70 0.38 0.70 0.48 0.70 0.04 0.26 0.04 0.13 0.00 I -

2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses {mrem/yr)

Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 TL-1-08 0.35 0.70 0.38

0. 70 0.48 0.70 0.04 0.26 0.04 0.13 MY 2016 Annual REO Report Page 21of28

Figure 4.5 Annual Dose Trend at TL-1-10 TL.. 1~10 30.00 25.00

... 20.00

~ 15.00

-t-TL-1-10 E 10.00

-limit 5.00 0.48 0.49 0.26 0.85 0.53 0.41 0.23 0.21 0.26 0.46

~

~

A 0.00

~

A

£ 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses (mrem/yr)

Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 TL-1-10 0.48 0.49 0.26 0.85 0.53 0.41 0.23 0.21 0.26 0.46 MY 2016 Annual REO Report Page 22 of 28

Figure 4.6 Annual Dose Trend at TL-1-12 TL-1-12 30.00....---------------------

25.00 +---------------------

.. 20.00 -!----------------------

~

~ 15.00 4----------------_.;,. _____ _

_.,_TL-1-12 e 10.00 ---------------------

-limit 0.80 0.28 5.00 -i--~------------------

0.05 0.79 0.10 0.61 0.25 0.41 Location 2007 TL-1-12 0.05 0.13 2007 2008 2009 2010 2011 2012 Year 2013 Annual Doses (mrem/yr) 2008 2009 2010 2011 2012 0.79 0.10 0.61 0.25 0.41 MY 2016 Annual REO Report 0.19 2014 2015 2016 2013 2014 2015 2016 0.13 0.80 0.19 0.28 Page 23of28

Figure 4.7 Annual Dose Trend at TL-1-14 TL-1.. 14 30.00 ~-----"------------------

25.00 +---------------------

... 20.00 +---------------------

~ 15.00 +---------------------

-+-TL-1-14 E 10.00 +--------------------_.,.,...lim_,i_t _

5.00 +------------------------

0.30 0.55 0.23 0.40 0.67 0.22 0.28 0.37 0.52 0.46 Location 2007 TL-1-14 0.30 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses (mrem/yr) 2008 2009 2010 2011 2012 2013 2014 2015 2016 0.55 0.23 0.40 0.67 0.22 0.28 0.37 0.52 0.46 MY 2016 Annual REO Report Page 24of28

Figure 4.8 Annual Dose Trend at TL-1-15 TL-1-15 30.00.....---------------------

25.00,__ ___________________

... 20.00 +---------------------

~

~ 15.00 +---------------------

E 10.00

-t-TL-1-15

-limit 5.00 0.30 0.67 0.76 0.87 0.57 0.66 0.50 0.41 0.22 0.69 0.00

~

2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Year Annual Doses (mrem/yr)

Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 TL-1-15 0.30 0.67 0.76 0.87 0.57 0.66 0.50 0.41 0.22 0.69 MY 2016 Annual REO Report Page 25of28

Figure 4.9 Annual Dose Trend at TL-1-16 TL-1-16 30.00....---------------------

25.00 +---------------------

.... 20.00 -t---------------------

<: 5 15.00 +---------------------

-t-TL-1-16 E 10.00 -+---------------------

-limit 5*00 o-_4-4---.o"""'.1=1=--o-.3-6_..,o,,_.s=9.--o-.-66--o.-45--o.-34--o..... s-9-o-.3-o-o-.s-s-2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 year Annual Doses (mrem/yr)

Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 TL-1-16 0.44 0.77 0.36 0.89 0.66 0.45 0.34 0.59 0.30 0.58 MY 2016 Annual REO Report Page 26of28

5.0 ANALYSIS OF ENVIRONMENTAL RES UL TS 5.1 Sampling Program Deviations A sampling program deviation is defined as samples that are unobtainable due to hazardous conditions or to malfunction of sampling equipment. Such deviations do not compromise the program's effectiveness and in fact are considered insignificant with respect to what is normally anticipated for this Radiological Environmental Monitoring Program.

There were no deviations of the sampling program in 2016.

5.2 Direct Radiation Pathway 5.2.1 Annual Dose Trends Direct radiation is continuously measured at 9 indicator locations surrounding the Maine Yankee ISFSI, along with 1 control location (Wiscasset Fire Station) using thermoluminescent dosimeters (TLDs). These dosimeters are collected every six months for readout at the NVLAP certified dosimetry services vendor.

Review of the data in Figures 4.1 through 4.9 shows no significant difference in annual doses over time at the indicator locations and their relation to the 25 mrem/yr limit.

5.2.2 Direct Doses from ISFSI Operations A dose estimate is the potential dose to any real member of the public that could use portions of the site or be present adjacent to the site for recreational activities throughout the year. Direct exposure above background can be estimated by subtracting the average TLD value of the control station from the indicator location measurements. As in previous years, the 2016 dose estimate assumes a total of 325 hours0.00376 days <br />0.0903 hours <br />5.373677e-4 weeks <br />1.236625e-4 months <br /> occupancy for the dose calculation; of which 162.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> are used in both the first and second half-years. The most likely location for exposure to a member of the public from the ISFSI is along the Back River, Bailey Cove or Montsweag Bay for boating and fishing and the mud flats in the Cove or Bay exposed at low tides which is worked by clam diggers and worm diggers; however, the time estimates are conservatively applied to all monitoring locations.

MY 2016 Annual REO Report Page 27of28

Table 4.3 presents the results of the dose calculations. The highest calculated dose is at Station ID number TL-1-06. The maximum calculated annual dose at that location is 1.28 mrem. This value is only 5 percent of the 25 mrem per year limit. It is noted that most of the mud flat region in Bailey Cove that is used by the public is situated further away from this Station. As a result, actual exposures from direct radiation would be much less than the maximum calculated value.

6.0 REFERENCES

1.

USNRC RadiologicalAssessment Branch Technical Position, "An Acceptable Radiological Environmental Monitoring Program," Revision 1, November 1979.

2.

Maine Yankee Offsite Dose Calculation Manual, Revision 36.

3. 40 CFR Part 190, "Environmental Radiation Protection Standards for Nuclear Power Operation".
4.

1 O CFR Part 72.104, "Criteria for-Radioactive Materials in Effluents and Direct Radiation from an ISFSI or MRS".

MY 2016 Annual REO Report Page 28of28