{{#Wiki_filter:.. = Exelon Generation*, April 28, 2017 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

Peach Bottom Atomic Power Station Units 1, 2 and 3 Independent Spent Fuel Storage Installation {ISFSI) - Facility Operation License DPR-12, DPR-44 and DPR-56 NRC Docket 50-171, 50-277 and 50-278 and ISFSI Docket 72-29 Annual Radioactive Effluent Release Report 59 January 1, 2016 through December 31, 2016 Enclosed is the Annual Radioactive Effluent Release Report 59, January 1, 2016 through

  • December 31, 2016 for Peach Bottom Atomic Power Station, Units 1, 2 and 3.

This report is being submitted in compliance with 10 CFR 50.36a(2) and the Technical Specifications of Operating Licenses DPR-44 and OPR-56 and to fulfill the requirements of Offsite Dose Calculation Manual Specifications (ODCMS) 3.10.2. Additionally, this report is submitted to satisfy the annual effluent reporting requirements for the ISFSI required by the ODCM. No revision to the ODCM occurred during the 2016 reporting period. There are no commitments contained in this letter. If you have any questions or require additional information, please do not hesitate to contact Dr. Amber Donley at 717-456-3056. Sincerely,. ~1-- Matthew Herr, Plant Manager Peach Bottom Atomic Power Station MJH/SMO/GRS/ASD/asd Enclosure ( 1) cc: USNRC Region I, Regional Administrator (Daniel H. Dorman) USN RC Senior Resident Inspector, PBAPS (Justin Heinly) USNRC Region I Inspector (Bruce Dionne) CCN 17-40

PEACH BOTTOM ATOMIC POWER STATION Unit Numbers 2 and 3 Docket Numbers 50-277 and 50-278 Unit Number 1 Docket Number 50-171 PBAPS Independent Spent Fuel Storage Installation Docket Number 72-29 RADIOACTIVE EFFLUENT RELEASE REPORT N0.59 JANUARY 1, 2016 THROUGH DECEMBER 31, 2016 Submitted to The United States Nuclear Regulatory Commission Pursuant to Facility Operating licenses DPR-44 and DPR-56

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: (This page intentionally left blank) 2 Exelon Generation Company, LLC PSEG Nuclear, LLC

I I Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: TABLE OF CONTENTS Exelon Generation Company, LLC PSEG Nuclear, LLC INTRODUCTION...................................................................................................................................... 5 ATIACHMENT 1: SUPPLEMENTAL INFORMATION................................................................................. 7 Regulatory limits...................................................................................................................... 8 Maximum Permissible Concentrations..................................................................................... 9 Average Energy...................................................... ;.................................................................. 9 Measures and Approximations of Total Radioactivity............................................................ 10 Batch Releases........................................................................................................................ 12 Average Stream Flow.............................................................................................................. 13 Abnormal or Unplanned Releases......................... ~............................... ;................................ 13 Changes to the ODCM............................................................................................................ 14 Minimum Detectable Concentrations..................................................................................... 15 Violations................................................................................................................................. 15 Dose Assessment.................................................................................................................... 15 ATIACHMENT 2: EFFLUENT

SUMMARY

............................................................................................... 18 Gaseous Effluents* Summation of All Releases...................................................................... 19 Gaseous Effluents Release Point: Elevated (Main Offgas Stack)............................................. 20 Gaseous Effluents Release Point: Ground-Level (Units 2 and 3 Reactor Building Exhaust Vents and Abnormal Releases}............................................................................................... 21 Liquid Effluents-Summation of All Releases.......................................................................... 22 liquid Effluents Release Points - Liquid Radwaste, RHR Leaks and Groundwater................. 23 ATIACHMENT 3: SOLID WASTE AND IRRADIATED FUEL SHIPMENTS.................................................. 24 Solid Waste Shipped............................................................................................................... 25 Irradiated Fuel Shipments....................................................................................................... 27 changes to Process Control Program (PCP}............................................................................ 27 ATIACHMENT 4: RADIOLOGICAL IMPACT ON MAN.............................................................................. 28 Radiological Impact on Man................................................................................................... 29 4*0 CFR 190 Doses................................................*.........................................................*......... 29 ATIACHMENT 5: METEOROLOGICAL DATA......................................................................................... 30 APPENDIX A: ERRATA DATA SECTION.................................................................................................. 87 2014 ARERR Abnormal Gaseous Release................................................................................ 88 2015 ARERR Gaseous Effluent Release Point: Ground-Level.................................................. 88 2008-2016 Dose to Member of the Public Onsite.................................................................. 91 3

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Technical Concurrence (for accuracy of information): Manager, Site Chemistry, E vironmental and* Radwaste 4 Exelon Generation Company, LLC PSEG Nuclear, LLC

Peach Bottom Atomic Power Station Unit 2 and 3 INTRODUCTION Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC In accordance with the Reporting Requirements of Technical Specification 5.6.3 applicable during the. reporting period, this report summarizes the Effluent Release Data for Peach Bottom Atomic Power Station {PBAPS) Unit~ 2 and 3 for the period January i, 2016 through December 31, 2016. The notations E+ and E-are used to denote positive and negative exponents to the base 10, respectively. The release of radioactive materials during the reporting period was within the Offsite Dose Calculation Manual Specification (ODCMS) limits. There were two (2). unplanned releases of liquid radioactive material. One release was from Residual Heat Removal (RHR) heat exchanger (beginning July of 2016) and the other is from groundwater tritium contamination ('tritium plume'). These releases were far below regulatory limits. There were two (2) unplanned releases of gaseous radioactive material during the Unit 2 21st Refueling Outage. On October 28, 2016, a particulate filter from High Efficiency Particulate Air (HEPA) unit tent exhaust over the Unit 2 Condensate Storage Tank (CST) manway showed cobalt-60 (Co-60) contamination. The unit had been operating for 730 minutes. On November 3, 2016 a particulate filter at the Unit 2 moisture separator hole in the wall showed Co-60 and cesium-137 (Cs-137) contamination. Negative pressure could nofbe maintained in the turbine building while the wall was removed to support Unit 2 feedwater heater outage work activities. Details of these releases are Included lri this report. Both of these releases were far below regulatory limits. The maximum calculated organ dose (bone) from iodines (1-131, 1-133 and i-135), tritium (H-3), carbon-14 (C-14) and particulates to any Individual due to all gaseous effluents was S.96E-01 mrem, which was approximately L99E+o0% of the annual limit. The maximum calculated air dose in the UNRESTl:UCT~D Area due to noble gas effluents was 2.53E-Ol mrad (gamma) and

1. 73E-01 n;trad (beta), which was 1.26E+OO% and 4.32E.:01%, respectively, of the annual limits.

In 2016, ~here were no direct gaseous or liquid rele.ases or discharges fron:i Unit 1 to the environment. There were no gaseous or liquid radioactive releases frorri the Independent Spent Fuel Storage Installation, NRC Docket No. 72-29 (ISFSI). 5

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC No revision Was made to RW-AA-100 11Process Control Program for Radioactive Waste" in 2016. No revision was made to the ODCM and Appendix A of ODCM during the 2016 reporting period. - Exelon Nuclear common procedures, which provide consistent expectations and standards for Radioactive Effluents Controls Program (RECP), were used to generate this report. PBAPS site specific procedures used to assist with abnormal/unplanned releases were also used to generate this report. They are: CY*AA-170-000, Radioactive Effluent and Environmental Monitoring Program CY-AA-170-100, Radiological Environmental Monitoring Program CY-AA-170-200, Radioactive Effluent Controls Program CY-AA-170-300, Offslte Dose Calculation Manual Administration CY-AA:-170-2000, Annual Radioactive Effluent Release Report CV-AA-170-2100, Estimated Errors of Effluent Measurement CY*AA-170-3100, Offslte Dose Calculation Manual Revisions CY-AA-170-2300, Determination of Carbon-14 in Gaseous Effluents

  • . CY-PB-170-202, RHR-HPSW Leak Rate Calculation CY-PB-170-2020, Radiologfcal Abnormal Gaseous Release Assessment 6

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC A TIACHMENT 1: SUPPLEMENTAL INFORMATION 7

Peach Bottom Atomic Power Station Unit 2 and 3 Regulatory Limits Table 1. Noble Gas Dose Rate and Dose Limits Maximum Value Units 500 Mrem/vr 3000 mrem/yr 10 mrad 20 mrad 20 mrad 40 mrad Licensee: Exelon Generation Company, LLC PSEG Nuclear, tLC Limit Classiflcatlon Speclflcatlon annual total body dose ODCM Specification rate 3.8.C.1.a annual skin dose rate ODCM Specification 3.8.C.1.a gamma radiation air dose ODCM Specification per quarter 3.8.C.2.a beta radiation in air dose ODCM Specification per quarter 3.8.C.2.b gamma radiation in air ODCM Specification dose per year 3.8.C.2.c beta radiation in air dose ODCM Specification per year 3.8.C.2.d Table 2. Iodines, Tritium and Particulates (with half-lives> 8 days) Dose Rate and Dose Limits Maximum Value Units Limit Classification Specification mrem/yr annual dose rate limit to ODCM Specification 1500 3.8.C.1.b any organ lS annual dose limit to any ODCM Specification mrem 3.8.C.3.a organ per quarter 30 mrem dose limit to any organ ODCM Specification per year 3.8.C.3.b 8

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Table 3. Uquld Effluent Activity Concentration and Dose Rate Umlts Ma1tlmum Value Units Limit Classlflcatlon Specification ~ 10 times 10 CFR 20, Activity Concentration in ODCM Specification Appendix B, Table 2, µCi/ml Column2 all liquid releases 3.8.B.1.a total activity 2E-04 µCi/ml concentration for all ODCM Specification dissolved and entrained 3.8.B.1.b noble gases 3.0 mrem total body dose limit per OOCM Specification quarter 3.8.B.2.a 10 mrem total body dose limit per OOCM Specification year 3.8.B.2.a 6.0 mrem dose limit per quarter to ODCM Specification any organ 3.8.B.2.b 20 mrem dose limit per year to any ODCM Specification organ 3.8.B.2.b Maximum Permissible Concentrations Gaseous dose rates, rather than effluent concentrations, are used to calculate permissible release rates for gaseous releases. The maximum permissible dose rates for gaseous releases are defined in ODCMS 3.8.C.1.a and 3.8.C.1.b. The Effluent Concentrations limits (ECL) specified in 10 CFR 20, Appendix 8, Table 2, Column 2 multiplied by 10, for identified nuclides, are used to calculate permissible release rates and concentrations for liquid release per ODCMS 3.8.B.1. The total activity concentration for all dissolved or entrained noble gases is limited to < 2E-04 µCl/ml (ODCMS 3.8.B.1.b). Average Energy The PBAPS ODCM limits the dose-equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/yearto the skin. Therefore, the average beta and gamma energies of the radionuclide mixture in releases of fission and activation gases as described in Regulatory Guide 1.21, Revision 1, 11Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from light-Water-Cooled Nuclear Power Plants, 11 are not applicable to PBAPS. 9

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Measures and Approximations of Total Radioactivity Fission and Activation Gases Exelon Generation Company, LLC PSEG Nuclear, LLC The method used for gamma isotopic analysis is the Canberra Genie' System with a gas Marinelli beaker. Grab samples are taken and analyzed weekly to determine the isotopic mixture of noble gas activity released for the week. Airborne effluent gaseous activity was continuously monitored and recorded in accordance with ODCMS Table 4.8.C.1. The data from the noble gas radiation monitor were analyzed to report noble gas effluent activities. When no activity was identified in the grab isotopic analysis, the entire release must be assumed to be the radionuclide with the most-limiting dose factors for the release pathway (i.e. krypton-88 {Kr-88) for all ground:.level releases, Kr-88 for elevated gamma dose and Kr-87 for elevated beta dose; see ODCM IV.B and NUREG-01331}. The activity released is listed as "unidentified" in the Attachment 2 Tables. If activity was found in the grab isotopic analysis, the isotopic mixture for the Noble Gas Monitor was determined from that isotopic mixture. Iodines The method used is the Canberra Genie' System with a charcoal cartridge. Iodine activity was continuously sampled and analyzed in accordance with ODCMS Table 4.8.C.1. Particulates The method used is the Canberra Genie' System with a particulate filter (47 mm diameter). Particulate activity was continuously sampled and analyzed in accordance with ODCM Table 4.8.C.1. Composite particulate air samples were submitted to an offsite vendor laboratory for analyses of strontium-89 (Sr-89), Sr-90, nickel-63 {Ni-63) and gross alpha. carbon-14 The amount of C-14 released was estimated using the guidance from the Electric Power Research Institute {EPRI) Technical Report 1021106, "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents". The C-14 was released primarily through the Main Offgas Stack (9.70E+Ol%) with a small amount (3.00E+OO%) through the Reactor Building Exhaust Vents. The C-14 in liquid effluents is not a significant dose pathway, as determined from studies. The resulting annual dose to the maximum conservative receptor is S.95E-01 mrem, with.the limiting receptor as the child bone. 1 http://www.nrc.gov/read.ing-rm/doc*collectlons/nuregs/staff/sr0133/sr0133.gdf, accessed 9 April 2014. 10

Peach Bottom Atomic Power Station Unlt2 and 3 Liquid Effluents Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Gamma isotopic activity concentrations are determined on each batch of liquid effluent prior to release using the Canberra Genie' System in accordance with ODCMS Table 4.8.B.1. The total activity of a released batch is determined by multiplying each nuclide's concentration by the total volume discharged. Composite liquid radwaste samples are analyzed for tritium on-site and submitted to an offsite vendor laboratory for analyses of iron-SS (Fe-55), phosphQrus-32 (P-32), Sr-89, Sr-90, Ni-63, and gross alpha. Decommissioned Unit 1 Liquid Radioactive Waste Processing There were no direct gaseous or liquid releases or discharges from Unit 1 to the environment during 2016. During the reporting period, a total of 238 gallons of water with low concentrations of tritium were collected from Unit 1 and ~tared at Unit 2 and 3; for future processing. No gamma emitting nuclides were above detectable limits. No water was released which originated from Unit 1 during 2016. Estimate of Total Error Present CY-AA-170-2100, 11Estimated Errors* of Effluent Measurements", provides the methodology to obtain an overall estimate of the error associated with.radioactive effluents. 11

Peach Bottom Atomic Power Station Unit 2 and 3 Batch Releases Licensee: Table 4. Quarterly Liquid Batch Release Statistics First Quarter Second Quarter Number of Batch Releases 5 0 Total Time for Batch Releases (minutes) 3.30E+02 Q Maximum tiine period for batch 1.65E+02 0 release (minutes) Average time period for batch release 6.60E+01 0 (minutes) Minimum time period for batch 3.50E+Ol 0 release (minutes) Average Stream Flow (ft3/ s)2,3 7.0SE+03 7.0SE+o3 Dilution volume (liters) 1.09E+09 0 Table S. Quarterly Gaseous Batch Release Statistics First Quarter Second Quarter Number of batch 0 0 releases: Total Time for batch 0 0 releases (minutes) Maximum time 0 0 period for batch release (minutes): Average time period 0 0 for batch release (minutes) Minimum time 0 0 period for batch release (minutes) 2 Average Stream Flow is not used for dose calculation. Exelon Generation Company, LLC PSEG Nuclear, LLC Third Quarter Fourth Quarter 4 11 2.62E+02 6.99E+02 9.20E+01 1.60E+02 6.SSE+Ol 6.35E+Ol 3.90E+Ol 1.00E+Ol 7.0SE+03 7.05E+03 1.19E+09 1.87E+09 Third Quarter Fourth Quarter 0 2 0 l.30E+03 0 7.30E+02 0 6.50E+02 0 5.70E+02 3 USGS National Water Information System, Site Name: "Susquehanna River at Marietta, PA", Site Number: 01576000. Data accessed 15 February 2017.

12.

Peach Bottom Atomic Power Station Unit 2 and 3 Average Stream Flow Licensee:

  • Exelon Generation Company, LLC PSEG Nuclear, LLC The river flow is not used for dose calculations. The actual flow rate of Circulation Water (the water that is circulated within the plant for cooling) is determined for each liquid effluent release because this Circulation Water provides dilution and therefore reduces the projected dose.

Abnormal or Unplanned Releases 'Abnormal' releases are those releases that are not defined as 'normal' releases in the Licensee's ODCM. While attempts are made to ensure radioactivity is not released offsite without processing, monitoring of systems with a potential for release is continuously performed. Source terms used for dose calculatlons utilize dfrect sampling and the maximum concentrations of nuclides to ensure that the most conservative and bounding estimates are used. Methodologies calculate conservative dose utilizing conservative mathematical models to describe intake and exposure pathways. Therefore, reported doses for these abnormal releases are calculated conservatively. Lf guf d Releases Groundwater Tritium Plume During 2016, during the sampling and analysis of the Radiological Ground Water Protection Program (RGPP), tritium was measured e;tt several locations around the site. The ground water that has detectable tritium has been determined to flow into the Plant intake and eventually flow into the normal Discharge Canal. Details of this program can be found in the Peach Bottorn Annual Radiological Environmental Operating Report (AREOR} as an appendix. No other nuclides were detected in monitoring wells. Analysis of Release It was assumed from the maximum flow rates measured4 that ground water flowed to the discharge canal at a steady rate of 3.17E+02 gpm, carrying with it some of the tritium underneath the plant. The conservative maximum dose for the entire year from this continuous release is calculated to be 4.96E-OS mrem {whole-body) and 4.96E*OS mrem (any organ, except bone5 which is o.OOE+OO mrem)6* This dose contribution projection is well below the limit specified in the ODCM. Heat Exchanger Leakage Starting in July of 2016, a small leak developed in the Unit 3 C Residua! Heat Removal (RHR) Heat Exchanger, which is designed to circulate water to remove heat from the reactor unit When necessary~ The dose model assumes that contaminated water leaks from the heat exchanger, regardless of operating pressure to ensure conservatism in calculated dose. As an additional precaution, installed radiation monitoring instrumentation can indicate an inadvertent release of radioactive material should the heat exchanger develop a large leak unexpectedly. 4 ".Estimated Mass Flux OfTrltiated Groundwater To The Conowingo Reservoir And Rock Run Creek, Peach Bottom Atomic Power Station, Delta, Pennsylvania';, November 2012, Conestoga-Rovers & Associates. s Tritium dose factor for bone is O.OOE+OO; therefore no hypothetical dose is calculated. 6 These doses are identical because the dose factors are identical for the same nuclide and pathway. 13

Peach Bottom Atomic Power Station Unit 2 and 3 Analysis of Release Licensee: Exelon Generation Company, UC PSEG Nuclear, LLC It was assumed that the water released to the discharge canal, for the second half of 2016, contributed a conservative maximum 3.liE-05 mrem total body dose (receptor child), and a conservative maximum 1.18E*04 mrem for the conservative maximum organ, adult GI-LU, dose. This dose contribution was well below the limits specified in the ODCM. Samples were analyzed for all the parameters of radioactive effluent releases. Composite liquid TORUS water samples were counted for tritium and submitted to an offsite vendor laboratory for analyses of Fe-55, P-32, Sr*89, Sr-90, Ni-63 and gross alpha. The dose contributions and isotope quantities from the releases were added to this Radioactive Effluent Release Report for the applicable reporting periods. Gaseous Releases Unit 2 Moisture Separation Room Hole in the Wall A hole was cut into the Turbine Building wall to perm it the movement of sea vans and feedwater heaters in and out of the plant during th.e 21st refueling outage on Unit 2 (P2R21). When the wall was removed, the plant ventilation was not controlled for negative pressure, also air flow Indicator strips were not present at the opening (Issue Report (IR) #2736932). Positive air flow was noticed on November 2-3, 2016. The particulate air samples were pulled immediately and analyzed for radioactivity. The maximum concentration of Co-60 was found to be 2.98E-12 µCi/cc and Cs-137 at 6.84E-13 µCi/cc. Positive air flow of 7816 cubic feet per minute (CFM) was estimated for a period of 5. 70E+02 minutes. The conservative dose rate 4.59E-04 mrem/year to Teen Lung and dose 6.34E-07 mrem to Infant Liver, calculated for this release is well below the limits in the ODCM. No other nuclides were identified. Contaminated HEPA Unit A contaminated HEPA unit was in service on the tent around the Unit 2 CST manway work during the 21st refueling outage on Unit 2 (P2R21). The first air particulate sample pulled from the HEPA exhaust identified Co-60. A second, confirmatory, sample was pulled a short while later and Co-60 was identified again. The HEPA was removed from service and an issue was written (IR #2733962). The unit was in service from October 27-28, 2016 for 7.30E+02 minutes and assumed to be operating at the max rated flow of 2.00E+03 CFM. The maximum concentration of Co-60 was found to be 4.lOE-11 µCi/cc. The conservative dose rate (1.61E-04 mrem/year to Teen Lung) and conservative dose (1.97E;.Q6 mrem to Infant liver) calculated for this release is well-below the limits in the ODCM. No other nucfides were identified. Changes to the ODCM There were no revisions to either the ODCM or the ODCM Specifications {Appendix A) during 2016. 14

Peach Bottom Atomic Power Station Unit 2 and 3 Minimum Detectable Concentrations Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC If a radionuclide was not detected, 11<LLD 11 was reported as the activity. Samples were analyzed with techniques that achieved the required Lower Limits of Detection (LLD) as specified in ODCMS Table 4.8.B.1, 11Radioactlve Liquid Waste Sampling and Analysis 11 (for liquids) or ODCMS Table 4.8.C.1, "Radioactive Gaseous Waste Sampling and Analysis from Main Stack and Vent Stack" (for gases). In all cases, the LLD requirements were satisfied. Violations There were no effluent release violations for the 2016 reporting period. Dose Assessment Introduction A dose assessment for PBAPS was conducted from measured radioactive effluent source terms and. environmental data to verify that PBAPS continues to demonstrate compliance with the limits as well as the requirement of maintaining the doses "as low as is reasonably achievable" as stated in 10 CFR 50, Appendix 1.7 The radioactive source term used for both liquids and gases are the current radioactive source terms given in this report, Attachment 2, "Effluent Summary". Liquid Dose Assessment Hydro/ogic Conditions and Receptor Locations of Interest PBAPS is located on the Conowingo Pond formed in the Susquehanna River by the Conowingo Dam. For 2016, the annual average river flow8 was measured as 2.82E+04 ft3 /s. Ofthese three separate flow regimes that were used in the original Appendix I submittal, the most-limiting of them (<1.SOE+04 ft3 /s) was used to calculate a dose assessment for this report because this would provide a bounding extreme for all PBAPS liquid effluents. Therefore, although the actual average stream flow for the year was more than double the limiting case, this report will provide an upper limit for the most-limiting dose. The annual average dilution factor9 at the Conowingo Intake is 5.40E+OO and the assumption for the reconcentration factor10 is 1.16E+OO. The PBAPS shorewidth factor11 of 2.00E-01 was also used. 7 http:Uwww.nrc.gov/readlng-rm/doc-collections/cfr/partOSO[partOSO*appi.html, accessed 9 April 2014. 8 USGS National Water Information Service; Monitoring Site 01576000,Susquehanna River at Marietta, PA; http://waterdata.usgs.gov/nwis. Accessed 15 Feb 2017. 9 From original ODCM. 1° From original ODCM. 11 RG1.109, Table A-2. 15

Peach Bottom Atomic Power Station Unit2and 3 Table 6. Consumption and Usage Rate Assumptions Pathway Adult Eating Flshu 2.lOE+Ol Drinking Watern 7.30E+02 Swlmmlng14 2.BOE+02 Boatlng14 1.20E+02 Shoreline Recreation14 3.2SE+02 Fishing from Conowlngo Dam14 3.2SE+02 Licensee: Teenager 1.60E+o1 S.10E+02 2.80E+02 1.20E+02 3.25E+02 3.25E+02 Exelon Generation Company, LLC PSEG Nuclear, LLC Child Infant Units 6.90E+OO O.OOE+oO kg/yr S.10E+02 S.10E+o2 L/yr O.OOE+OO O.OOE+OO h/yr 6.70Et01 O.OOE+OO h/yr 1.40E+Ol O.OOE+OO h/yr o.ooe+oo o.ooe+oo h/yr No invertebrate intake was examined because invertebrate ingestion pathways are not considered to be significant in the area close to PBAPS. The pathway factors for the various age groups, used to determine dose to the public from liquid effluents are shown in Table 6. Liquid Effluent Dose Assessment Conclusion For all permitted releases in 2016, the calculated total body dose was 5.47E-05 mrem and 9.24E-05 mrem for the limiting organ of adult liver. Therefore, PBAPS liquid radioactive effluent controls continue to demonstrate compliance with 10 CFR SO, Appendix I objectives for the purposes of keeping doses to members of the public 0 as low as is reasonably achievable". These limiting or maximum calculated doses are a srnall fraction of the limits in Appendix I. Gaseous Dose Assessment The gaseous dose assessment calculates the co.nservative dose at the limiting receptor locations from the land-use census data, the 2016 meteorology and the 2016 source term to demonstrate compliance with 10 CFR 50, Appendix I. Tables 7 and 8 utilized the CY-PB-170-210 spreadsheet to calculate the doses for elevated and ground releases with the 2016 METdata and gaseous total activity released, including C-14. Table 7 utilized MET data from the locations with the highest X/Q from the Main Offgas Stack .and the corresponding Reactor Building Exhaust Vents MET factors. Table 8 utilized MET data from the locations with the highest D/Qsectors from the Reactor Building Exhaust Vents and

  • the corresponding Main Offgas Stack MET factors. The X/Q values are very similar to those used In the ODCM, and therefore the differences in noble gas dose is minimal. The larger discrepancies between Iodine, Particulates, Tritium (l/P/T) organ doses can be explained by the differences in pathways. Tables 7 and 8 assume that there is a milk pathway at each of the listed locations.

The ODCM defines the milk pathway at 1500m SW and the D/0$ are more comparable (2016 vent: 2.0lE-9 1/m2 vs. ODCM vent: l.SSE-09 l/m2) and therefore the doses are comparable to those reported below Tables 7 and 8. n RG 1.109, Table A-2. u All loca.tlons except Chester Water Authority from RG 1.109, Section A-2. Chester Water Authority uses 10% of the RG 1.109 value because it is assumed to have 10% sourced from Conowingo Pond. 14 From PBAPS Environmental Report, Supplement No. 3, Page 19. Boating data derived from a ratio of Adult:Chlld rates as listed In RG 1.109, Table A-2. 16

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Table 7. Conservative Maximum Elevated Release Dose from 2016 Source Term and 2016 Meteorology Distance 2016 2016 Vent Totar Body Skin Gamma Beta Air l/P/T/C-limiting Direction Highest MS Dose Dose Air Dose Dose 14 Dose (m) X/Q(O/Q) X/Q(D/Q) (mrem) (mrem} (mrad) (mrad) (mrem} Receptor 4900 N 4.42E-08 l.14E*07 2.57E-02 3.34E-02 2.GSE-02 1.83E*02 l.34E*Ol Bone (3.lOE-10) (S.99E-10) 3800 SW 4.31E-08 1.19E*07 2.68E*02 3.48E-02 2.77E-02 1.90E*02 l.09E*Ol Bone (2.S2E-10) {5.0lE-10} Table 8. Ground-Level Dose from 2016 Source Term and 2016 Meteorology Skin Beta.Air l/P/T/C-Distance 2016 2016 MS Total Body Gamma limiting Direction Highest Vent Dose Dose Air Dose Dose 14 Dose (m) D/Q{X/Q} X/Q(D/Q) (mrem) (mrem} (mrad} (mrad) (mrem} Receptor 1200 SSE 1.00E*OB 5.46E-09 2.42E-01 3.14E-01 2.SlE*Ol 1.69E-01 4.84E-01 (1.llE-06} (6.31E-10) 900 NW 6.64E*09 3.60E-09 2.SlE-01 3.2SE-01 2.60E-01 1.75E-01 3.56E-01 (1.lSE-06) (5.0BE-10) Gaseous Radioactive Effluent Dose Assessment Conclusion The conservative maximum dose was 5.96E-01 mrem with the maximum receptor as the child bone and this is due to the incorporation of carbon-14 in the calculation. Without C-14, the maximum dose* is 3.47E-03 mrem to the infant thyroid. The noble gas limiting air doses were 2.53E-01 mrad (gamma) and 1.73E-01 mrad (beta). Noble gas plume conservative dose was 2.45E-01 mrem for the year (Total Body) and 3.19E-Ol mrem (Skin Dose) for the year. Bone Bone A dose assessment was performed for members of the public due to their activities inside the site boundary. The location where a person would receive the largest calculated total body dose inside the site boundary was at the Vehicle checkpoint, approximately 1,900 feet N of the PBAPS Unit 2 and Unit 3 roof vents. Assuming continuous occupancy, the calculated total body and skin doses were 1.82E-01 mrem and 2.35E-01 mrem, respectively. The noble gas limiting air doses were 1.88E-01 mrad (gamma) and 1.27E-01 mrad (beta). All doses are projected to be much less than the limits, as expected. Again, these dose models incorporate several factors of conservatlsm including a source term that, by procedure, will use the most dose-limiting noble gas nuclide when no fission gas can be identified by grab sample but activity is detected from the effluent radiation monitor. Exelon Nuclear uses a detailed C-14 dose projection from the Electric Power Research Institute, Technical Report 1021106. Details for the assumptions used In th ls calculation may be found there.15 Therefore, PBAPS gaseous radioactive effluent controls continue to demonstrate compliance with 10 CFR 50, Appendix I objectives for the purposes of keeping doses to members of the public "as low as is reasonably achievable". These limiting or maximum calculated doses are a small fraction of the limits in Appendix I. I$ PBAPS uses specific Boiling Water Reactor assumptions because the fraction of C-14 that is in the C02 form will vary based on general plant design. This is important because the major dose pathway is through photosynthesis and, therefore, only the oxide form is relevant. 17

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC ATTACHMENT 2: EFFLUENT

SUMMARY

18

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Gaseous Effluents - Summation of All Releases Period: January 1, 2016 through December 31, 2016 Unit: Peach Bottom A. Fission & Activation Gases Units Quarter l Quarter2 Quarter3 Quarter4

l. Total Release Ci 8.50E+Ol 1.21Et02 8.48Et01 2.63E+-02
2. Avera11e release For the Period uCl/s l.OSE+Ol 1.S4E+ol l.07E+Ol 3.31E+Ol
3. Gamma Air Oose mrad 3.72E-02 S.47E*02 3.30£-02 l.28E*01
4. Beta Air Dose mrad 2.S6E-02 3.7SE-02 2.29E-02 8.7SE-02
5. Percent of OOCM limit Gamma Alf Dose 3.72£-01 S.47E-01 3.30E*Ol l.28E+-OO Beta Air Dose 1.28E*Ol l.88E*Ol 1.15E-01 4.37E-Ol B. lodtnes
1. Total 1-131 Cl 4.S4E*OS 8.69E*OS 1.37E*04 1.SOE-04
2. Average release For the Period uCt/s S.77E*06 l.lOE-05 l.73E*OS 2~26E-{}5'
3. Percent of ODCM limit

"' No ODCM defined Curie Limit, therefore a percentage of the limit cannot be calculated.

c. Particulate
1. Particulates with Tl/2 > 8 davs Cl 9.64E*OS l.07E*04 1.09E*04 2.S2E-04
2. Avera11e release For the Period uCl/s 1.23E-OS l.36E*OS 1.37E*05 3.17E-OS
3. Percent of ODCM limit
  • No ODCM defined Curie Limit, therefore a percentage of the limit cannot be calculated.

0 Tritium

l. Total Release Ci 4.61E+OO S.13E+OO l.29E+ol 1.llE+Ol
2. Average release For the Perlod uCl/s S.86E-01 6.52E-01 1.63E+OO l.40E+OO
3. Percent of OOCM limit
  • No ODCM defined Curie Limit, therefore a percentage of the limit cannot be calculated.

th E. Gross AIPI a

1. Total Release Cl

<LLD . <LLD <LLD <LLD

2. Average release For the Period uCI/ s

<LLO <LLD <LLD <LLD

3. Percent of ODCM limit
  • No ODCM defined Curie Limit, therefore a percentage of the limit cannot be calculated.

F. Carbon*14

1. Total Release Ci 9.60E+-00 9.60E+OO 9.60E+OO 9
2. Avera e release For the Period UCl/s 1.22E+OO l.22E+OO l.21E+OO G. lodlne*131, 133and135, Tritium, Carbon-14 & Particulate
l. Or an oose*

mrem 1.49E-01 1.49E-01 1.49E*Ol 1.49E*01

2. Percent ODCM limlt 9.93E*Ol 9.93E*Ol 9.93E*Ol 9.93E*01

"'C-14 contributes most significantly; thererore the quarterly dose to the child bone is reported 19 Est. Total Error% 4.00E+Ol 1.90E+{)1 I 2.SOE+ol I I l.30E+Ol I t

  • -"'--4.00E~02 j

Peach Bottom Atomic Power Station Unit 2 and 3 licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Gaseous Effluents Release Point: Elevated (Main Offgas Stack) Period: January 1, 2016 through December 31, 2016 Unit: Peach Bottom Nudldes Released Continuous Mode Batch Mode

1. Rnlon Gases Unit Quarter 1 Quarterz.

Quarter3 Quarter4 Quarter 1 Quarter2 Quarter3 Quarter4 l<r*8S Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr*8Sm Cl <UO 5.98E*Ol 4.66E+OO 2.66E+OO <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LlD <llD <LLD <LLD <LLD <LLD <LLD Kr*88 Cl <llO <LLD <LLD <lLO <LLD <LLD <LLD <LLD Xe-133 Cl <UD 1.39E+oo 7.88E+OO S.lSE+-00 <LLD <LLD <LLD <LLD Xe*135 Ci <UD <LLD 2.S8E+o0 5.SlE+-00 <LLD <LLD <LLD <LLD Xe-135m Cl <UD <LLD <LLD <LLD <LLD <LLD <LLD <UD Xe*138 Cl <LLD 2.22E+oo <lLO <LLD <LLD <LLD <LLD <LLD Ar-41 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <U.O Unidentified a l.6SE+ol 1.S9E+ol 9.19E+o0 1.30E+ol <LLO <LLD <LLD <LLD Total For Period a l.GSE+ol 2.0lE+ol 2.43E+ol 2.63Et01 <LLD <LLD <LLD <LLD 2.lodlnes 1-131 Cl 3.59E*OS 4.23E-OS 4.97E*OS 7.02E*OS <LLD <LLD <LLD <LLD 1*133 Ci B.59E*05 l.27E*04 l.44E*04 1.71£.04 <lLO <LLD <UD <LLD 1*135 Cl <LLD <LLD <LLD 2.64E-OS <LLD <LLD <LLD <LLD Total For Period Cl 1.22E*04 1.69E*04 1.93E*04 2.68E*04 c:LLO <LLD <LLD <UO

3. Particulates Sr*89 Cl 3.99E*05 3.61E*G5 3.64E*05 3.SSE.05

<LLD <LLD <LLD <LLD Sr-90 Cl <llD <LLD <lLD <UD <LLD <LLD <LLD <LLD Cs-134 Cl <llO <LL)) <LtD <LLD <LLD <LLD <LLD <LLD Cs-137 Cl 1.30f*07 <LLD <LlO <LLD <LLD <LLD <LLD <LLD Ba-140 Cl 1.00E*OS l.21E*OS l.73E*OS l.20E*OS <LLD <LLD <LLD <LLD La-140 Cl <LLO <lLD <llD <LLD <LLD <LLD <LLD <LLD Cr*Sl Ci <LLD <llD <LlD <LLD <LLD <LLD <llO <LLO Mn-54 Cl <LLD <llD 4.67E*07 1.71£-07 <UO <LLD <llD <:LLD Co-58 Cl <LlO <LLD <llD l.OSE*07 <LLD <LLD <LLD <LLD Co-60 Cl 1.76E-06 8.99E-06 7.46E*06 1.12E-OS <LLD <LLD <lLO <LLD Mo*99 Cl <LLD <UO <lLO <LLD <LLD <LLD <LLD <LLD Ag*llOm Ci <ltD <llO <llD <LLD <LLD <LLD <LLD <LLD Ce-14! Cl <UD <LLD <llO <LLD <LLD <LLD <LLD <ttO Ce*144 Ci <LLD <llD <LLD <LLD <llD <LLD <UO <LLO Zn-65 Cl <LLD <LLD <LLD l.79E-06 <LLD <LLD <LLD <LLD Total For Period Ci S.18E*G5 5.72£-05 6.16£*05 6.08E-05 <UO <LtD <LLD <tlO

4. Tritium H-3 Cl l.98E-Ol 2.SSE-01 8.73E*Ol 4.86E*Ol

<LLD <LLD <UO <t.lO

5. Gross Alpha Gross Alpha Ci

<LLD <llO <UD .:UD <LLD <LLD <UO <UD 5..Carbon-14 C*14 Cl 9.311!+00 9.31E+OO 9.31E+OO 9.31E+OO <LLD <llD <LLD <LLD 20

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Gaseous Effluents Release Point: Ground-level {Units 2 and 3 Reactor Building Exhaust Vents and Abnormal Releases} Period: January 1, 2016 through December 31, 2016 Unit: Peach Bottom Nuclldes Released Continuous Mode Batch Mode

l. Fission Gases Unit Quarter 1 Quarter 2 Quarter3 Quarter4 Quarterl Quarter2 Quarter 3 Quarter 4 Kr-85 Ci

<LLO <LLD <LLD <LLD <LLD <LLO <LLD <I.LO Kr-8Sm Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr*87 Cl <llD <LLD <ltD <UO <LLD <LLD <LLD <LLD Kr-88 a <LLD <LLD <LLD <LLD <LLD <LLD <LLD <UO Xe-133 a <UO <llO <LLD <LLD <LLD <LLD <LLD <UO Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <UO <LLD <LLD <LLD Xe-138 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ar-41 Cl <LLD <LLD <LLD <LLD <LLD <lLD <LLD <LLD Unidentified Ci 6.8SE+Ol 1.01E+02 6.0SE+ol 2.37E+02 <LLD <LLD <LLD <LLD Total For Period Ci 6.8SE+01 1.01E+02 6.0SE+Ol 2.37E+02 <UO <LLD <LLD <LLD

2. Iodines f.131 Cl 9.49E*06 4.45E-05 8.76E*OS l.lOE-04

<LLD <LLD <lLD <LLD 1*133 Cl 3.37E*OS 2.33E-04 4.02E-04 1.90E*04. <LLD <LLD <LLD <LLD 1-135 Cl <LLD <LLD <LLD <llD <lLD <LLD <LLD <LLD Total For Period Cl 4.32E-05 2.78E*04 4.89E*04 3.00E-04 <LLD <LLD <LLD <LLD

3. Particulates Sr-89 Ci

<llD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <llD <LLD <llO <LLD. <LLD <llO <LLD <LLD Cs-134 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Cl <LlO 4.22E*06 <LLD 4.!0E-06 <LLD <ltO <LLD 8.63E*08 Ba-140 Ci <LLD <LLD <LLD <LlO <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD cr-51 Ci <.LLD <LLD <LLD 8.93E-05 <LLD <LLD <LLD <LLD Mn*S4 Cl <LLD <LLD <LLD 7.81E-06 <LLD <LLD <U.0 <LLD Co-58 Cl <lLD <LLD <LLD 7.74E*OG <LLD <LLD <LLD <LLD Co-60 Ci 4.46E-05 3.90E-05 4.72E-05 B.02£-05 <LlD <LLD <LLD 2.07E-06 Mo-99 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag*110m Ci <LlD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Cl <LLO <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <lt.0 <LLD <LLD <LLD <LLD Zn-65 Cl <LLD 6.46E*06 <LLD <LLD <LLD <LLD <LLD <LLD Total For Period Cl 4.46E*OS 4.97E*OS 4.72E-05 l.89E-04 <LLD <LLD <LLD 2.lSE-06 4.Trltlum H*3 Cl 4.41E-t00 4.87E+oo 1.21E+Ol 1.07E+Ol <LLD <LLD <LLD <LLD S. Gross Alpha Gross Alpha Cl <LLD <LLD <t.LD <LLD <LLD <LLD <LLD <LLD

6. carbon*14 C*14 Ci 2.88E*Ol 2.88E*Ol 2.BSE-01 2.88E-01

<LLD <LLO <UO <LLD 21

Peach Bottom Atomic Power Station Unit 2 and 3 Liquid Effluents - Summation of All Releases Period: Januarv 1 2016 to December :u, 2016 A. Fission & Activation Gases Units Quarter!

1. Total Release {not Including tritium, gases

&alpha) Ci O.OOE+OO

2. Average diluted concentration for the Period uCI/ ml O.OOE+OO
3. Perc;ent of ilPPlicable limit Total Bodv Oose S.40E-04 OnzanOose l.62E-04 B. Tritium
1. Total Release 0

1.64E+oo

2. Average diluted concentration for the Period

µCi/ml 2.62E*09

3. Percent of apollcable llmit*

2.62E*OS

  • 1ox 10CFR20 Limit of 1.00E-03 uCi/ ml; OOCMS 3.8.B.1.a C. Dissolved & Entrained Gases
1. Total Release Ci S.06E-05
2. Average diluted concentration for the Period

µCl/mL 8.07E*15

3. Percent of OOCM limit' Licensee:

Quarter2 0.00E+OO O.OOE+OO 4.66E-04 l.40E*04 1.58E+OO 2.37E*09 2.37£.tlS <LLD <llD. Exelon Generation Company, LLC PSEG Nuclear, LLC u ach nit: Pe Bottom Est. Total Quarters Quarter4 Error% 1.S4E*03 2.59E-03 1.6-0E+Ol 2.28E-12 3.79E*12 8.40E*04 2.68E-03 5.99E*04 l.S9E*03 Est. Total Error% 1.41E+OO 1.8SEtOO 6.40E+OO 2.09E-09 2.91E*09 2.09£*05 2.91E*05 Est. Total Error% l.06E*06 3.34E-05 2.80E+Ol 1.S7E-15 S.27E*l4

  • No ECL values for Xe isotopes in 10 CFR 20 Appendix B Table 2, therefore a percentage of the limit cannot be calculated.

D. Grau Aloha Acthtltv

1. Total Release E. Volume of Wasta Released (prior to dilution F. Volume of Dilution Water Used Durln11 Period a

Ute rs Liters I <LLD I 1.S7E+08 6.26E+11 22 Est. Total !rror% <LLO I <llO I c:LLO 2.30E+Ol l.57E+08 1.S9E+08 1.60Et08 6.68E+ll 6.77E+ll 6.34E+1l

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC liquid Effluents Release Points-liquid Radwaste, RHR Leaks and Groundwater Period: January l, 2016 throush December 31. 2016 Unit: Peach Bottom Nuclldes Released Continuous Mode Batch Mode Unit Quarterl Quarter 2 Quarter3 Quarter4 Quarter 1 Quarter2 Quarter3 Quarter4 Sr*89 Ci <LLD <LLD <LLD <LLD <tLD <LLD <LLD <LLD Sr*90 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs*l34 Ci <LLD <LLD <LLO <LLD <LLD <LLD <LLD <LLD Cs-137 Cl <LLD <LLD <LLD <LLD <LLD <LLD 1.18E-07 <LLD 1*131 Cl <LLD <LLD <LLD <LLD <LLD <LLD <lLD <LLD Co-58 Ci <LLD <LLD <LlD <LLD <LLD <LLD <LLD 4.54E-05 Co-60 Cl <LLD <LLD l.19E-03 1.83E*03 <LLD <LLD <LLD 1.36E-04 Fe-59 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD S.89E*OS 7.4SE*OS <LLD <LLD <LLD l.14E*04 Mn-54 Cl <LLD <LLD 2.97E-04 2.22E*04 <LLD <LLD <LLD l.64E*04 Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zr-95 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nb-95 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tc*99m Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-140 Cl <LLD <LLD <LLD <LLD <lLD <LLD <lLD <LLD La*l40 Cl <LLD <LLD <LLD <tLO <llD <LLD <LLD <:LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD A11*1lOm Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1.03£-0S Fe-SS Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb-124 Cf <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb*12S Cl <LLD <LLD <LLD <LLD <LLD <LLD <lLD <LLD Ru*lOS Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD H-3 Cl 1.44Et00 1.58E+o0 1.41E+OO 1.09E+o0 2.04E*Ol <LlD 3.76E*04 7.SGE-01 P*32 Ci <LLD <LLD <LLD <LLD <LLD <LlD <LLD <LLD Total for Period a l.44E+OO l.58E+o0 l.41E+OO 1.lOEtOO 2.04E*Ol <Ll.O 3.77E*04 7.56E*Ol Xe-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 2.02E*05 Xe-135 Cl <LLD <LLD <LLD <LLD S.06E-06 <LLD l.06E-06 1.33E*OS Xe*138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LlO Total for Period le1C*trltlum, Ci O.OOE+oo O.OOE+oO 1.54£*03 2.13E*03 O.OOE+oO O.OOE+oO l.18E*07 4.70E*04 gases and alpha) 23

Peach Bottom Atomic Power Station Unit 2and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC ATIACHMENT 3: SOLID WASTE AND IRRADIATED FUEL SHIPMENTS 24

Peach Bottom Atomic Power Station Unit 2 and 3 Solid Waste Shipped 1.Tvoe of Waste Licensee: A: Spent Resin, Filters, Sludges, Evaporator Bottoms, etc B: Dry Compressible Waste, Contaminated Equipment, etc. C: Irradiated Components, Control Rods, etc. 0: Other (Oil, SBLC) 2.Estimate of Major Nuclide Comgosition {by type of waste)

a. Spent-Resin, Filters, Sludges.1 Evaporator Bottoms, etc.

Abundance% Nuclide (no cutoff) Activity (Ci) Nucllde H*3 9.00E-02 2.20E-01 Sb-124 C-14 3.SOE-01 8.97E-01 Sb-125 Cl-36 O.OOE+OO 1.36E-06 1-129 Ar-39. O.OOE+OO 7.22E-07 1-131 Cr-51 1.13E+OO 2.66E+OO Cs.;134 Mn-53 O.OOE+OO 1.91E-08 Cs-137 Mri-54 2.34E+OO 5.53E+OO Ba-140 Fe-55 1.66E+Ol 3.91E+Ol La-140 Fe-59 2.10E~01 4.97E-01 Ce-141 Co-58 1.40E-01 3.28E-01 Ce-144 Co-60 5.94E+ol 1.40E+02 Pm-149 Ni-59 l.OOE-02 2.29E-02 Sm-151 Ni-63 2.23E+OO 5.26E+OO Eu-152 Zn-65 5.13E+OO 1.21E+01 Eu-154 Sr-89 O.OOE+OO 4.lOE-05 Eu-155 Sr-90 4.00E~02 9.45E-02 Tb-158 Zr-95 O.OOE+OO 3.24E-05 Ho-166m Nb-94 O.OOE+OO 6.67E*07 Hf-181 Nb-95 O.OOE+oO 9.48E-07 Pu-238 Mo-93 O.OOE+OO 1.0SE-06 Pu-239 Tc~99 8.00E-02 1.81E-01 Pu-240 Ae-110m 1.00E-01 2.28E*Ol Pu-241 Sn-121m O.OOE+OO 2.72E-08 Pu-242 Sb-124 1.00E-02 1.36E-02 Am-241 Sb-125 O.OOE+OO 6.40E-03 Cm-242 1-129 1.00E-02 2.0SE-02 Cm-243 Cm-244 25 Exelon Generation Company, LLC PSEG Nuclear, LLC Unlts 2016 Est. error% ma 1.21E+02 Ci 2.36E+02 2.SOE+Ol m3 1.17E+03 Ci 3.97E+OO 2.SOE+Ol ma S.8SE*01 Ci S.13E+OO 2.SOE+Ol m3 3.48E+01 Ci 3.42E*04 2.SOE+Ol Abundance% (no cutoff} Activity (Cl) 1.00E-02 1.36E-02 O.OOE+OO 6.40E-03 1.00E-02 2.0SE-02 O.OOE+OO 2.42E-21 3.00E-02 6.79E-02 l.19E+Ol 2.82E+Ol O.OOE+OO 3.88E-14 O.OOE+OO 7.28E-92 O.OOE+OO 9.40E-07 1.90E-01 4.45E-01 O.OOE+OO 7.15E-106 O.OOE+oO 4.22E-07 O.OOE+OO 9.lOE-05 O.OOE+OO 1.0SE-05 O.OOE+OO 4.13E*03 O.OOE+OO 1.SOE-08 O.OOE+OO 2.59E-07 O.OOE+OO 3.95E-07 O.OOE+OO 1.37E-03 O.OOE+OO 2.02E-04 O.OOE+oO 2.74E-06 4.00E-02 8.GSE-02 O.OOE+OO 2.24E-04 O.OOE+OO 9.48E-04 O.OOE+OO 3.52E-05 O.OOE+OO 3.0SE-04 O.OOE+OO 2.13E-03

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee:

b. Dry, Compressible Waste, Contaminated Equipment, etc.

Abundance% Nuclide (no cutoff) Activity (Cl) Nuclide H-3 1.60E-01 6.47E-03 Ag-110m C-14 S.OOE-02 1.92E-03 1-129 Cr-51 1.69E+OO 6.72E-02 Cs-137 Mn-54 3.70E+OO 1.47E*01 Ce-144 Fe*SS 2.33E+01 9.23E-01 Pu-238 Fe-59 8.SOE-01 3.SOE-02 Pu-239 Co-58 S.20E-01 2.04E-02 Pu-241 Co-60 S.77E+o1 2.29E+o0 Am-241 Ni-63 9.SOE-01 3.89E-02 Cm-242 Zn-65 6.17E+OO 2.4SE*Ol Cm-244 Sr-90 2.00E-02 7.67E-04 Tc-99 1.GOE-01 6.22E*03

c. Irradiated Components, Control Rods, etc.

Abundance% Nuclide (no cutoff) Activity (Ci) Nuclide H-3 O.OOE+OO 1.SlE-05 Ni-59 C-14 1.00E-04 4.68E-04 Ni-63 Cr-51 O.OOE+OO 2.29E-04 Zn-65 Mn-54 1.0SE-02 5.52E*02 Zr-95 Fe-55 3.75E-01 l.92E+OO Nb*94 Fe-59 O.OOE+OO 7.95E-05 Tc-99 Co-58 5.00E-04 2.66E-03 1-129 Co-60 5.SSE-01 2.85E+OO Cs-137 Ce-144

d. Other: Oil Abundance%

Activity Nuclide (no cutoff} {Cl) H-3 3.92E+Ol 1.34E-04 C*14 7.59E+OO 2.60E-05 Co-60 4.20E-01 1.43E-06 Ni-63 6.35E+OO 2.17E*OS Tc-99 1.87E+01 6.40E-05 Sn-113 9.00E-02 2.91E-07 1*129 2.66E+ol 9.09E-05 Cs-137 l.90E*01 6.52E-07 Ce-144 9.20E-Ol 3.13E-06 26 Exelon Generation Company, LLC PSEG Nuclear, LLC Abundance% (no cutoff) Activity (Ci) 5.70E-01 2.2SE*02 1.00E-02 4.41E-04 3.60E+OO 1.43E-01 5.SOE*Ol 2.20E*02 O.OOE+OO 8.07E-07 O.OOE+OO 1.lSE-07 O.OOE+OO 9.17E-06 O.OOE+OO 5.52E-07 O.OOE+OO 1.30E-07 O.OOE+OO 1.94E-06 Abundance% (no cutoff) Activity (Cl) 1.20E-03 S.98E*03 S.74E-02 2.94E-01 3.00E-04 1.32E-03 O.OOE+OO 3.llE-15 O.OOE+OO 4.67E*06 O.OOE+OO 2.99E-05 O.OOE+OO 2.36E*06 O.OOE+OO 1.85E-OS O.OOE+OO 2.19E-OS

Peach Bottom Atomic Power Station Unit 2 and 3 licensee: 3.Solid Waste Disposition Number of shipments Mode of Transportation 30 Hittman Transport Services 10 Hittman Transport Services 26 Hittman.Transport Services 2 Visionary Solutions, LLC Irradiated Fuel Shipments Exelon Generation Company, LLC PSEG Nuclear, LLC Destination Energy Solution Services (CVRF) Bear Energy Solution Services (GRF) Gallaher Energy Solutions LLC Clive Disposal Site-Energy SOiutions LLC Clive Disposal Site-No shipment of irradiated fuel was made during the reporting period of 2016. Changes to Process Control Program (PCP) There was no revision to RW-AA-100 during the 2016 reporting period. 27

Peach Bottom Atomic Power Station Unit 2and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC ATTACHMENT 4: RADIOLOGICAL IMPACT ON MAN 28

Peach Bottom Atomic Power Station Unit 2 and 3 Radiological Impact on Man Applicable Estimated Effluent Organ Dose Noble Gas I Gamma-2.53E*01 Air Dose Noble Gas Beta - Air 1.73E-01 Dose Total Noble Gas Body 2.45E*01 (gamma) Noble Gas Skin 3.19E*01 (Beta) Gaseous

Iodine, Particulate, Bone 5.95E*Ol Carbon-14 &

Tritium Gaseous

Iodine, Thyroid 3.47E*03 Particulate &

Tritium Total Liquid Body 1.36E-04 (gamma) GI-LL! 2.43E-04 Direct Total O.OOE+OO Radiation Body 40 CFR 190 Doses Applicable Estimated Effluent Organ Dose Total Dose Total 2.45E-01 Body Total Dose Thyroid 3.47E-03 Total Dose Bone S.95E*Ol Total Dose Total 2.45E-01 Body Total Dose Bone 5.95E-01 Total Dose Thyroid 2.56E-01 Age Group All All All All Child Infant Child Child All Age Group All All All All All All Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Location %of Distance Direction Applicable (meters) (toward) limit Limit Unit 1.10E+03 SSE 1.26E+OO 2.00E+Ol mrad t.10E+03 SSE 4.32E-01 4.00E+Ol mrad 1.10E+03 SSE 2.45E+OO l.OOE+Ol mrem 1.10E+03 SSE l.06E+OO 3.00E+Ol mrem 1.10E+03 SSE 1.98E+OO 3.00E+Ol mrem i 1.10E+03 SSE 1.16E-02 3.00E+Ol mrem 2.26E*03 6.00E+OO mrem Site Boundary 1.21E-03 I 2.00E+Ol mrem 1.15E+03 SSE O.OOE+OO 2.20E+01 mrem Location %of Distance Direction Applicable (meters) (toward) Limit Limit Unit 1.15E+03 SSE 9.79E-01 2.SOE+Ol mrem 1.15E+03 SSE 4.63E-03 7.SOE+Ol mrem 1.15E+o3 SSE 2.38E+OO 2.SOE+Ol mrem 1.1SE+03 SSE 8.16E+OO 3.00E+OO mrem 1.1SE+03 SSE 1.98E+Ol 3.00E+OO mrem 1.1SE+03 SSE 4.66E*Ol 5.SOE+Ol mrem 29 I I

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC ATTACHMENT 5: METEOROLOGICAL DATA 30

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T ( F} Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 0 0 0 0 2 NNE 0 12 0 0 0 0 12 NE 7 7 0 0 0 0 14 ENE 10 5 0 0 0 0 15 E 8 4 0 0 0 0 12 ESE 0 4 4 0 0 0 B SE 0 1 2 0 0 0 3 SSE 0 0 3 2 0 0 5 s 0 0 9 0 0 0 9 SSW 0 0 9 1 0 0 10 SW 0 0 4 0 0 0 4 WSW 0 0 6 1 0 0 7 w 0 0 2 0 3 0 5 WNW 0 1 0 5 0 0 6 NW 0 1 1 9 0 0 11 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 25 37 40 18 3 0 123 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 8 31

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 4 1 0 0 0 5 NNE l 5 0 0 0 0 6 NE 5 3 0 0 0 0 8 ENE 8 1 0 0 0 0 9 E 5 3 0 0 0 0 8 ESE 0 3 0 0 0 0 3 SE 0 3 3 0 0 0 6 SSE 0 1 5 0 0 0 6 s 0 1 9 1 0 0 11 SSW 0 1 3 0 0 0 4 SW 0 l 9 0 0 0 10 WSW 0 0 4 2 0 0 6 w 0 3 17 4 1 0 25 WNW 0 0 7 14 0 0 21 NW 0 3 6 20 1 0 30 NNW 0 5 15 a 0 0 28 Variable 0 0 0 0 0 0 0 Total 19 37 79 49 2 0 186 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: s 32

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2. and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Slightly Unstable 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed {in mph} Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 7 2 0 0 0 9 NNE 0 3 0 0 0 0 3 NE 2 3 0 0 0 0 5 ENE 1 2 0 0 0 0 3 E 4 2 0 0 0 0 6 ESE 0 1 1 0 0 0 2 SE 1 4 1 0 0 0 6 SSE 0 3 4 0 0 0 7 s 0 2 2 0 0 0 4 SSW 0 0 l 0 0 0 1 SW 0 0 2 1 0 0 3 WSW 0 0 1 2 0 0 3 w 0 1 8 8 0 0 17 WNW 0 2 7 11 0 0 20 NW 1 5 9 4 0 0 19 NNW 0 3 12 0 0 0 15 Variable 0 0 0 0 0 0 0 Total 9 38 50 26 0 0 123 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 8 33

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Neutral - 150Ft-33Ft Delta-T (Fl Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 10 25 6 8 0 0 49 NNE 12 14 6 2 0 0 34 NE 34 27 1 0 0 0 62 ENE 20 5 0 0 0 0 25 E 18 21 0 0 0 0 39 ESE 9 17 3 0 0 0 29 SE 6 17 11 1 0 0 35 SSE 6 24 24 3 0 0 57 s B 17 29 12 0 0 66 SSW 4 9 5 2 0 0 20 SW 3 3 11 1 0 0 18 WSW 4 7 11 8 0 0 30 w 6 37 56 20 l 0 120 WNW 6 30 72 30 0 0 138 NW 10 39 69 10 0 0 128 NNW 5 34 43 18 0 0 100 Variable 0 0 0 0 0 0 0 Total 161 326 347 115 1 0 950 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 31 Hours of missing stability measurements in all stability classes: 8 34

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 13 6 0 0 0 0 19 NNE 7 0 0 0 0 0 7 NE 9 1 0 0 0 0 10 ENE 17 4 0 0 0 0 21 E 25 7 0 0 0 0 32 ESE 10 9 1 0 0 0 20 SE 19 9 5 1 0 0 34 SSE 10 17 3 0 0 0 30 s 17 12 3 0 0 0 32 SSW 13 12 2 0 0 0 27 SW 13 22 6 0 0 0 41 WSW 9 37 6 0 0 0 52 w 17 32 6 0 0 0 55 WNW 13 15 0 0 0 0 28 NW 13 17 1 0 0 0 31 NNW 11 13 5 0 0 0 29 Variable 0 0 0 0 0 0 0 Total 216 213 38 1 0 0 468 Hours of calm in this stability class: 11 Hours of missing wind measurements in this stability class: 3 Hours of missing stability measurements in all stability classes: 8 35

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Moderately Stable - 150Ft-33E't Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 0 0 0 0 0 6 NNE 2 0 0 0 0 0 2 NE 3 0 0 0 0 0 3 ENE 4 0 0 0 0 0 4 E 12 0 0 0 0 0 12 ESE 12 4 0 0 0 0 16 SE 10 3 1 0 0 0 14 SSE 2 1 0 0 0 0 3 s 6 0 0 0 0 0 6 SSW 9 1 a 0 0 0 10 SW 6 6 0 0 0 0 12 WSW 16 15 3 0 0 0 34 w 11 3 0 0 0 0 14 WNW 4 1 0 0 0 0 5 NW 6 3 0 0 0 0 9 NNW 5 1 0 0 0 0 6 Variable 0 0 0 0 0 0 , a Total 114 38 0 0 0 156 Hours of calm in this stability class: 9 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: a 36

Peach Bottom Atomic Power Station Unit 2 and 3 ~icensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottqm Atomic Power Station Period of Reco~d: January - March 2016 Stability Class - Extreme1~ S~able 150Ft-33Ft Delta-T (F) Winds Mea'sured at 33 Feet ~i W,ind :Speed (in mph)

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Extremely Unstable - 316E't-33Ft Delta-T ( F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 1 1 0 0 0 2 NE 0 1 2 0 0 0 3 ENE 0 1 2 0 0 0 3 E 0 0 0 0 0 0 0 ESE 0 0 0 1 0 0 1 SE 0 0 2 1 0 0 3 SSE 0 0 0 0 0 0 0 s 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0

  • O 0

0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 3 7 2 0 0 12 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 38

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 2 0 0 0 0 2 E 0 0 1 0 0 0 l ESE 0 0 1 0 0 0 1 SE 0 0 0 1 0 0 1 SSE 0 0 0 1 1 0 2 s 0 0 1 3 0 0 4 SSW 0 0 0 1 0 0 1 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 1 0 1 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 2 3 6 2 0 13 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 39

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Slightly Unstable - 316Ft-33E't Delta-T (E') Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 l 0 0 0 0 1 NNE 0 0 0 1 0 0 l NE 1 1 0 0 0 0 2 ENE 0 3 1 D 0 0 4 E 0 3 0 0 0 0 3 ESE 0 1 2 0 0 0 3 SE 0 0 1 3 0 0 4 SSE 0 0 0 1 0 0 1 s 0 0 1 3 l 0 5 SSW 0 0 1 9 0 0 10 SW 0 0 3 2 0 0 5 WSW 0 0 0 5 0 0 5 w 0 0 0 2 1 5 8 WNW 0 0 0 0 9 6 15 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 1 9 9 26 11 11 67 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 40

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Neutral - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 21 25 8 0 8 62 NNE 5 16 20 8 3 6 58 NE 5 13 23 7 1 0 49 ENE 4 19 19 5 0 0 47 E 3 26 15 6 0 0 50 ESE 3 10 35 5 1 0 54 SE 3 9 29 7 7 1 56 SSE 2 5 21 16 7 1 52 s 3 6 17 32 22 4 84 SSW 1 4 4 9 2 0 20 SW 0 4 7 20 4 0 35 WSW 0 6 4 13 14 5 42 w 0 9 19 58 69 23 178 WNW 1 8 21 71 77 29 207 NW 0 15 29 88 27 6 165 NNW 2 10 24 26 8 9 79 Variable 0 0 0 0 0 0 0 Total 32 181 312 379 242 92 1238 Hours of calm in this stability class: 0 Hours of missin9 wind measurements in this stability class: 8 Hours of missing stability measurements in all stability classes: 10 41

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 8 19 14 0 0 42 NNE 2 9 3 1 0 0 15 NE 0 6 6 0 0 0 12 ENE 2 12 5 0-0 0 19 E 4 10 7 7 1 0 29 ESE 0 5 7 5 1 0 18 SE 1 13 11 7 3 3 38 SSE 2 6 11 9 2 0 30 s 1 14 35 23 5 1 79 SSW 0 13 10 12 1 1 37 SW 3 12 19 11 10 0 55 WSW 2 6 8 17 1 0 34 w 1 10 14 22 6 1 54 WNW 0 4 24 26 2 0 56 NW 1 10 22 16 2 0 51 NNW 1 6 7 4 0 0 18 Variable 0 0 0 0 0 0 0 Total 21 144 208 174 34 6 587 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 6 Hours of missing stability measurements in all stability classes: 10 42

1*

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC 'i Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 2 0 0 O* 0 3 NNE 2 1 0 0 0 0 3 NE 1 2 1 0 0 0 4 ENE 2 1 0 0 0 0 3 E 1 1 1 0 0 0 3 ESE 0 0 0 0 1 0 1 SE 1 1 s 1 0 1 9 SSE 2 1 6 0 0 0 9

]'

s 0 6 13 3 0 0 22 SSW 3 4 9 5 0 0 21 "*).

1 SW 3

9 12 7 0 0 31 WSW 6 3 5 5 0 1 20 w 1 5 3 5 0 0 14 WNW 0 3 3 1 0 0 7 NW 2 9 3 1 0 0 15 NNW 2 0 1 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 27 48 62 28 1 2 168 {, Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 10 43

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: January - March 2016 Stability Class - Extremely Stable - 316Ft-33Ft Delta-T ( F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 1 0 0 0 0 1 SE 3 2 0 0 0 0 5 SSE 0 1 2 0 0 0 3 s 2 2 1 0 0 0 5 SSW 0 0 8 1 0 0 9 SW 1 8 7 2 0 0 18 WSW 2 5 1 2 0 0 10 w 0 4 3 0 0 0 7 WNW 0 3 4 0 0 0 7 NW 0 2 2 0 0 0 4 NNW 0 2 2 0 0 0 4 Variable 0 0 0 0 0 0 0 Total 9 30 30 5 0 0 74 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Extremely Unstable 150Ft-33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 19 1 0 0 0 20 NNE 6 25 0 0 0 0 31 NE 16 10 0 a 0 0 26 ENE 27 13 0 a 0 0 40 E 29 6 0 0 0 0 35 ESE 4 13 0 0 0 0 17 SE 2 11 2 0 0 0 15 SSE 0 4 7 1 1 0 13 s 0 4 20 3 0 0 27 SSW 0 0 2 2 0 0 4 SW 0 0 3 1 0 0 4 WSW 0 0 1 3 0 0 4 w 0 5 4 1 0 0 10 WNW 0 2 8 8 0 0 18 NW 0 2 8 5 1 0 16 NNW 0 15 20 5 0 0 40 Variable 0 0 0 0 0 0 0 Total 84 129 76 29 2 0 320 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 10 45

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 e-12 13-18 19-24 > 24 Total N 7 5 1 1 0 0 14 NNE 10 3 0 0 0 0 13 NE 14 0 0 0 0 0 14 ENE 13 2 0 0 0 0 15 E 7 1 0 0 0 0 a ESE 0 2 0 0 0 0 2 SE 1 8 0 0 0 0 9 SSE 1 9 7 0 0 0 17 s 1 6 12 0 0 0 19 SSW 0 6 2 0 0 0 8 SW 0 2 7 3 0 Q 12 WSW 0 5 8 2 0 0 15 w 0 4 11 6 0 0 21 WNW 1 2 6 2 0 0 11 NW 0 7 11 4 2 0 24 NNW 0 11 14 7 0 0 32 Variable 0 0 0 0 0 0 0 Total 55 73 79 25 2 0 234 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 46

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 6 0 0 0 0 10 NNE 7 2 0 0 0 0 9 NE 9 0 0 0 0 0 9 ENE 5 0 0 0 0 0 5 E 5 1 0 0 0 0 6 ESE 4 0 0 0 0 0 4 SE 1 4 0 0 0 0 5 SSE 3 7 0 1 0 0 11 s 1 5 6 0 0 0 12 SSW 1 1 1 0 0 0 3 SW 0 3 3 1 0 0 7 WSW 0 4 4 2 0 0 10 w 0 2 6 2 0 0 10 WNW l 1 4 0 0 0 6 NW 0 3 0 2 1 0 6 NNW 2 3 7 3 0 0 15 Variable 0 0 0 0 0 0 0 Total 43 42 31 11 1 0 128 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 47

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Neutral - 150Ft-33Ft Delta-T (E') Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 21 20 10 1 0 0 52 NNE 46 17 1 0 0 0 64 NE 31 1 0 0 0 0 32 ENE 19 0 0 0 0 0 19 E 25 3 0 0 0 0 28 ESE 9 8 0 0 0 0 17 SE 17 42 5 0 0 0 64 SSE; 21 62 27 1 0 0 111 s 19 33 20 4 0 0 76 SSW 6 16 3 0 0 0 25 SW 3 11 8 0 0 0 22 WSW 7 17 10 .2 0 0 36 w 6 7 16 4 2 0 35 WNW 4 9 13 2 2 0 30 NW 13 21 21 5 1 0 61 NNW 10 26 37 16 0 0 89 Variable 0 0 0 0 0 0 0 Total 257 293 171 35 5 0 761 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 10 48

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 14 2 0 0 0 0 16 NNE 16 5 0 0 0 0 21 NE 11 0 0 0 0 0 11 ENE 14 0 0 0 0 0 14 E 13 2 0 0 0 0 15 ESE 25 1 0 0 0 0 26 SE 19 10 0 0 0 0 29 SSE 27 13 2 0 0 0 42 s 19 19 1 0 0 0 39 SSW 22 16 0 0 0 0 38 SW 18 18 3 0 0 0 39 WSW 16 39 14 0 0 0 69 w 28 27 2 0 0 0 57 WNW 26 23 0 0 0 0 49 NW 22 21 1 0 0 0 44 NNW 7 15 3 0 0 0 25 Variable 0 0 0 0 0 0 0 T.otal 297 211 26 0 0 0 534 Hours of calm in this stability class: 10 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 49

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic l?ower Station Period of Record: April - June 2016 Stability Class - Moderately Stable 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 1 0 0 0 0 0 1 E 4 0 0 0 0 0 4 ESE 6 0 0 0 0 0 6 SE 2 0 0 0 0 0 2 SSE 3 0 0 0 0 0 3 s 3 0 0 0 0 0 3 ssw 4 2 0 0 0 0 6 SW 13 3 0 0 0 0 16 WSW 10 24 1 0 0 0 35 w 21 13 1 0 0 0 35 WNW 9 3 0 0 0 0 12 NW 2 0 0 0 0 0 2 NNW 0 1 0 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 79 46 2 0 0 0 127 Hours of calm in this stability class: 10 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: l(J so

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 1 0 0 0 0 0 1 SSE 0 0 0 0 0 0 0 s 1 0 0 0 0 0 1 SSW 3 0 0 0 0 0 3 SW 6 1 0 0 0 0 7 WSW 14 2 0 0 0 0 16 w 8 l 0 0 0 0 9 WNW 4 0 0 0 0 0 4 NW 2 0 0 0 0 0 2 NNW 1 0 0 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 41 4 0 0 0 0 45 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 10 51

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 3 3 0 0 0 6 NE 0 2 1 1 0 0 4 ENE 1 5 1 0 0 0 7 E 0 11 0 0 0 0 11 ESE 1 3 4 0 0 0 8 SE 0 0 1 0 0 0 1 SSE 0 0 0 0 0 0 0 s 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 2 24 10 1 0 0 37 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 52

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 2 0 0 0 3 NNE 0 l 1 0 0 0 2 NE 1 4 0 0 0 0 5 ENE 1 4 0 0 0 0 5 E 0 6 0 0 0 0 6 ESE 0 1 4 1 0 0 6 SE 0 0 1 0 0 0 1 SSE 0 0 0 1 0 1 2 s 0 0 0 0 3 0 3 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 1 0 0 1 WNW 0 0 0 0 2 0 2 NW 0 0 0 0 0 0 0 NNW 0 2 0 0 0 0 2 Variable 0 0 0 0 0 0 0 Total 2 19 8 3 5 1 38 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 8 53

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Slightly Unstable 316Ft-33Ft Delta-'l' {F} Winds Measured at 320 Feet Wind Speed (in mph} Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 8 2 1 0 0 11 NNE 0 9 0 0 0 0

9.

NE 0 2 1 0 0 0 3 ENE 0 9 0 0 0 0 9 E 3 7 0 0 0 0 10 ESE 0 2 1 0 0 0 3 SE 0 2 7 2 0 0 11 SSE 0 1 2 1 0 1 5 s 0 0 9 5 0 0 14 SSW 0 0 2 2 1 .0 5 SW 0 0 0 2 1 0 3 WSW 0 0 1 1 1 1 4 w 0 0 2 2 4 0 a WNW 0 0 0 1 13 2 16 NW

0.

0 4 8 1 0 13 NNW 0 5 7 6 2 0 20 Variable 0 0 0 0 0 0 0 Total 3 45 38 31 23 4 144 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 8 54

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach.Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Neutral - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4, 13 26 15 7 0 65 NNE 10 16 20 5 0 0 51 NE 8 36 19 6 0 0 69 ENE 8 42 23 0 0 0 73 E 9 23 38 1 0 0 71 ESE 8 22 28 9 0 0 67 SE 7 25 37 11 0 0 90 SSE 1 29 47 31 5 0 113 s 6 26 45 39 13 0 129 SSW 6 7 20 7 0 0 40 SW 2 7 14 17 2 0 42 WSW 2 6 16 23 9 7 63 w 3 7 9 25 15 9 68 WNW 1 6 9 19 13 10 58 NW 4 14 31 34 20 4 107 NNW 1 13 26 33 30 b 103 Variable 0 0 0 0 0 0 0 Total 80 292 408 275 114 30 1199 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 8 55

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic*l?ower Station l?eriod of Record: April - June 2016 Stability Clas~ - Slightly Stable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 13 11 2 1 0 31 NNE 6 7 7 0 0 0 20 NE 2 3 3 0 0 0 8 ENE 2 9 4 0 0 0 15 E 2 8 3 1 0 0 14 ESE 3 14 11 1 0 0 29 SE 2 10 17 2 0 0 31 SSE 4 15 16 5 0 0 40 s 8 14 36 16 2 0 76 SSW 4 7 19 10 0 0 40 SW 3 9 16 21 3 0 52 WSW 1 12 11 21 17 0 62 w 1 11 8 20 4 0 44 WNW 1 6 16 27 6 0 56 NW 2 6 11 14 0 0 33 NNW 2 14 17 8 1 0 42 Variable 0 0 0 0 0 0 0 Total 47 158 206 148 34 0 593 Hours of calm in this stability class: 0 Hours of missing wind.measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: a 56

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Moderately Stable 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 2 0 0 0 4 NNE 0 1 0 0 0 0 1 NE 0 0 0 0 0 0 6 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 2 1 1 0 0 4 SSE 3 4 0 0 0 0 7 s 0 4 4 0 0 0 8 SSW 2 2 1 0 0 0 5 SW 2 12

5.

1 1 0 21 WSW 0 3 0 9 3 0 15 w 1 2 4 13 3 0 23 WNW 1 7 2 6 0 0 16 NW 2 2 4 3 0 0 11 NNW 0 5 2 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 12 45 25 33 7 0 122 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 8 57

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: April - June 2016 Stability Class - Extremely Stable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 0 0 0 0 5 NNE 0 1 2 0 0 0 3 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 s 0 1 0 0 0 0 1 SSW 2 3 1 0 0 0 6 SW 2 3 3 3 0 0 11 WSW 0 0 1 0 0 0 1 w 0 0 0 0 0 0 0 WNW 0 1 0 1 0 0 2 NW 0 2 2 l 0 0 5 NNW 0 1 5 0 0 0 6 variable 0 0 0 0 0 0 0 Total 17 14 5 0 0 40 Hours Of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 8 58

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - E:xtremely Unstable - 150Ft-33Ft Delta-T (Fl Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 20 0 0 0 0 24 NNE 11 15 0 0 0 0 26 NE 12 2 0 0 0 0 14 ENE 11 0 0 0 0 0 11 E 5 0 0 0 0 0 5 ESE 8 5 0 0 0 0 13 SE 2 6 3 0 0 0 11 SSE 0 19 6 0 0 0 25 s 0 8 8 0 0 0 16 SSW 0 3 1 0 0 0 4 SW 0 4 3 3 0 0 10 WSW 0 1 5 0 0 0 6 w 0 3 0 0 0 0 3 WNW 0 1 0 0 0 0 1 NW 0 0 0 0 0 0 0 NNW 3 7 3 0 0 0 13 Variable 0 0 0 0 0 0 0 Total 56 94 29 3 0 0 182 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 18 Hours of missing stability measurements in all stability classes: 1 59

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station eeriod of Record: July - September 2016 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed t.in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 16 0 0 0 0 22 NNE 5 .5 0 0 0 0 10 NE 7 0 0 0 0 0 7 ENE 5 1 0 0 0 0 6 E 1 0 0 0 0 0 1 ESE 1 0 0 0 0 0 1 SE 6 5 2 0 0 0 13 SSE 0 23 3 0 0 0 26 s 0 16 7 0 0 0 23 SSW 1 7 5 0 0 0 13 SW 0 4 5 1 0 0 10 WSW 1 3 3 0 0 0 7 w 1 6 2 0 0 0 9 WNW 1 8 3 0 0 0 12 NW 1 14 2 0 0 0 17 NNW 3 32 19 0 0 0 54 Variable 0 0 b 0 0 0 0 Total 39 140 51 1 0 0 231 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 17 Hours of missing stability measurements in all stability classes: 1 60

Peach Bottom Atomic Power Station Licensee:- Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Slightly Unstable l50Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 6 0 0 0 0 7 NNE 6 3 1 0 0 0 10 NE 3 0 0 0 0 0 3 ENE 3 0 0 0 0 0 3 E 2 0 0 0 0 0 2 ESE 2 0 0 0 0 0 2 SE 0 2 0 0 0 0 2 SSE 1 8 1 0 0 0 10 s 0 6 3 0 0 0 9 SSW 0 3 0 0 0 0 3 SW 1 2 2 b 0 0 5 WSW 0 2 2 0 0 0 4 w 1 4 0 0 0 0 5 WNW 1 3 0 0 Q 0 4 NW 1 10 2 0 0 0 13 -NNW 1 22 5 0 0 0 28 Variable 0 0 0 0 0 0 0 Total 23 71 16 0 0 0 110 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 12 Hours of missing stability measurements in all stability classes: 1 61

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Neutral - 150Ft_;33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed {in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 27 31 2 0 0 0 60 NNE 19 23 l 0 0 0 43 NE 5 2 0 0 0 0 7 ENE 2 0 0 0 0 0 2 E 2 1 0 0 0 0 3 ESE 4 1 0 0 0 0 5 SE 7 13 2 0 0 0 22 SSE 15 43 7 0 0 0 65 s 17 25 2 0 0 0 44 SSW 11 12 2 0 0 0 25 SW 8 27 8 0 0 0 43 WSW 10 20 11 0 0 0 41 w 9 10 1 0 0 0 20 WNW 3 14 2 0 0 0 19 NW 5 33 7 0 0 0 45 NNW 14 26 5 0 0 0 45 Variable 0 0 0 0 0 0 0 Total 158 281 50 0 0 0 489 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 79 Hours of missing stability measurements in all stability classes: 1 62

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LlC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 34 32 2 0 0 0 68 NNE 24 23 0 0 0 0 47 NE 6 7 0 0 0 0 13 ENE 3 0 0 0 0 0 3 E 7 2 0 0 0 0 9 ESE 3 0 0 0 0 0 3 SE 15 3 l 0 0 0 19 SSE 26 36 3 0 0 0 65 s 35 17 0 0 0 0 52 SSW 37 12 0 0 0 0 49 SW 35 31 0 1 0 0 67 WSW 28 39 1 a 0 0 68 w 34 26 1 0 0 0 61 WNW 22 28 0 0 0 0 50 NW 27 33 1 0 0 0 61 NNW 26 17 2 1 0 0 46 Variable 0 0 0 0 0 0 0 Total 362 306 11 2 0 0 681 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 45 Hours of missing stability measurements in all stability classes: 1 63

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Moderately Stable 150Ft-33Ft Delta-T { F} Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 2 0 0 0 0 0 2 NE 1 0 0 0 0 0 1 ENE 0 0 0 0 0 0 0 E 2 0 0 0 0 0 2 ESE 1 0 0 0 0 0 l SE 1 0 0 0 0 0 1 SSE 4 0 0 0 0 0 4 s 1 1 0 0 0 0 2 SSW 14 7 0 0 0 0 21 SW 35 11 0 0 0 0 46 WSW 42 25 0 0 0 0 67 w 25 17 0 0 0 0 42 WNW 14 6 0 0 0 0 20 NW 5 8 0 0 0 0 13 NNW 2 2 0 0 0 0 4 Variable 0 0 0 0 0 0 0 Total 150 77 0 0 0 0 227 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 8 Hours of missing stability measurements in all stability classes: 1 64

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T ( E') Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 1 0 0 0 0 1 NE 0 0 0 0 0 0 0 . ENE 0 0 0 0 0 0 0 E 0 1 0 0 0 0 1 ESE 2 0 0 0 0 0 2 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 s 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 24 22 0 0 0 0 46 WSW 18 17 0 0 0 0 35 w 11 6 0 0 0 0 17 WNW 2 0 a a 0 0 2 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 D D 0 0 0 Total 57 47 0 0 0 0 104 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: l 65

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Extremely Unstable 316Ft-33E't Delta-T ( F} Winds Measured at 320 Feet Wind Speed {in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 l 0 0 0 0 1 NE 0 3 2 0 1 0 6 ENE 0 4 3 1 0 0 8 E 0 6 4 0 0 0 10 ESE 0 1 2 0 0 0 3 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 s 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 15 11 1 1 0 28 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 66

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 0 0 0 1 NNE 0 0 1 2 0 0 3 NE 0 1 3 0 0 0 4 ENE 1 7 1 0 l 0 10 E 1 3 0 0 0 0 4 ESE 0 2 5 0 0 0 7 SE 0 0 2 0 0 0 2 SSE 0 0 0 0 0 0 0 s 0 0 1 1 0 0 2 SSW 0 0 0 0 0 0 0 SW 0 0 1 1 0 0 2 WSW

o.

0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 2 14 14 4 1 0 35 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 67

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T ( F') Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 B-12 13-18 19-24 > 24 Total N 0 8 0 0 0 0 8 NNE 0 3 1 2 0 0 6 NE 3 3 0 0 1 0 7 ENE .1 7 0 0 0 0 8 E 0 3 0 0 0 0 3 ESE 0 4 2 2 0 0 8 SE 0 2 2 0 0 0 4 SSE 0 1 10 0 0 0 11 s 0 1 12 1 0 0 14 SSW 0 1 5 0 0 0 6 SW 0 1 0 3 2 0 6 WSW 0 0 2 3 0 0 5 w 0 0 1 0 0 0 1 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 2 1 1 0 0 4 Variable 0 0 0 0 0 0 0 Total 4 36 36 12 3 0 91 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: l 68

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Neutral

  • - 316Ft-33Ft Delta-T ( F)

Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 22 20 11 0 0 58 NNE 5 28 13 8 2 0 56 NE 10 17 6 12 3 0 48 ENE 9 18 9 13 2 0 51 E 8 17 3 1 1 3 33 ESE 7 23 4 2 0 0 36 SE 1 15 24 8 0 0 48 SSE 2 14 47 21 0 0 84 s 0 19 67 22 0 0 108 SSW 3 14 25 7 0 0 49 SW 1 24 29 14 1 0 69 WSW 2 8 14 16 0 0 40 w 4 15 23 1 0 0 43 WNW 2 19 14 8 1 0 44 NW 4 35 46 18 2 0 105 NNW 3 45 21 18 1 0 88 Variable 0 0 0 0 0 0 0 Total 66 333 365 180 13 3 960 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 69

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (Fl Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 8 32 12 1 0 54 NNE 5 9 21 5 0 0 40 NE 10 20 22 8 2 0 62 ENE 3 11 5 7 3 0 29 E 10 18 7 6 4 0 47 ESE 4 27 7 0 0 0 38 SE 4 10 14 20 0 0 48 SSE 3 8 31 14 0 0 56 s 7 16 47 19 0 0 69 SSW 2 23 37 15 0 0 77 SW 0 20 25 19 1 0 65 WSW 3 9 20 16 4 1 53 ~l 2 7 17 12 0 1 39 WNW 0 7 13 16 1 0 37 NW 0 12 16 24 6 0 58 NNW 2 12 11 19 1 0 45 Variable 0 0 0 0 0 0 0 Total 56 217 325 214 23 2 837 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 70

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T ( E') Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 9 6 0 0 0 15 NNE 3 5 1 0 0 0 9 NE 0 2 0 0 0 0 2 ENE 1 0 0 0 0 0 1 E 0 6 0 0 0 0 6 ESE 2 5 0 0 0 0 7 SE 5 9 0 0 0 0 14 SSE 4 10 3 0 0 0 17 s 0 3 8 1 0 0 12 SSW 2 9 4 6 0 0 21 SW 1 5 5 4 l 0 16 WSW 2 3 10 5 1 0 21 w 2 2 11 4 0 0 19 WNW 1 3 10 5 1 0 20 NW 1 1 6 8 0 0 16 NNW 1 4 3 3 0 0 11 Variable 0 0 0 0 0 0 0 Total 25 76 67 36 3 0 207 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: l 71

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: July - September 2016 Stability Class. - Extremely Stable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 5 l 0 0 0 7 NNE 0 4 0 0 0 0 4 NE 0 1 0 0 0 0 1 ENE 0 0 0 0 0 0 0 E 3 0 0 0 0 0 3 ESE 0 0 0 0 0 D 0 SE 3 1 0 0 0 0 4 SSE 0 2 0 0 0 0 2 s 0 1 0 0 0 0 1 SSW 0 0 0 0 0 0 0 SW 0 2 0 0 0 0 2 WSW 1 4 1 0 0 0 6 w 0 2 0 0 0 0 2 WNW 0 3 0 0 0 0 3 NW l 1 1 2 0 0 5 NNW i 2 3 1 0 0 7 Variable 0 0 0 0 0 0 0 Total 10 28 6 3 0 0 47 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 72

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 2 1 0 0 0 7 NNE 3 6 0 0 0 0 9 NE 5 0 0 0 0 0 5 ENE 9 0 0 0 0 0 9 E 8 0 0 0 0 0 8 ESE 1 0 0 0 0 0 1 SE 0 6 0 0 0 0 6 SSE 0 4 2 0 0 0 6 s 0 1 2 0 0 0 3 SSW 0 0 4 0 0 0 4 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 1 1 1 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 31 20 10 0 0 0 61 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 7 Hours of missing stability measurements in all stability classes: 4 73

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 B-12 13-18 19-24 > 24 Total N 2

10.

2 2 0 0 16 NNE 2 7 0 0 0 0 9 NE 2 1 0 0 0 0 3 ENE 7 0 0 0 0 0 7 E 4 0 0 0 0 0 4 ESE 3 0 0 0 0 0 3 SE 0 2 1 0 0 0 3 SSE 1 1 3 0 0 0 s s 0 0 2 2 0 0 4 SSW 0 5 1 0 0 0 6 SW 0 0 0 0 0 0 0 WSW 0 0 2 1 0 0 3 w 0 2 1 0 0 0 3 WNW 1 0 8 3 1 0 13 NW l 3 9 2 0 0 15 NNW 2 7 15 6 0 0 30 Variable 0 0 0 0 0 0 0 Total 25 38 44 16 1 0 124 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 6 Hours of missing stability measurements in all stability classes: 4 74

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Slightly Unstable 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 6 1 2 0 0 11 NNE 2 l 0 0 0 0 3 NE 2 0 0 0 0 0 2 ENE 2 0 0 0 0 0 2 E 1 0 0 0 0 0 1 ESE 1 1 0 0 0 0 2 SE 1 2 0 0 0 0 3 SSE 0 4 1 0 0 0 5 s 0 3 1 0 0 0 4 SSW l 1 1 0 0 0 3 SW 0 1 0 0 0 0 1 WSW 0 0 1 0 0 0 1 w 0 0 a 0 0 0 0 WNW 0 3 10 8 1 0 22 NW 0 5 11 5 1 0 22 NNW 0 8 21 5 0 0 34 Variable 0 0 0 0 0 0 0 Total 12 35 47 20 2 0 116 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in a11 stability classes: 4 75

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Neutral - 150Ft-33Ft Delta-T ( E') Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 16 15 20 6 0 0 57 NNE 31 5 0 0 0 0 36 NE 14 2 0 0 0 0 16 ENE 13 1 0 0 0 0 14 E 24 0 0 0 0 0 24 ESE 15 3 0 0 0 0 18 SE 1 28 3 0 0 0 32 SSE 4 48 15 0 0 0 67 s 4 31 11 1 0 0 47 SSW 4 13 4 1 0 0 22 SW 4 6 2 0 0 0 12 WSW 2 16 4 0 0 0 22 w 7 25 49 7 0 0 88 WNW 5 35 84 36 8 0 168 NW 1 33 47 15 1 0 97 NNW 8 49 71 21 0 0 149 Variable 0 0 0 0 0 0 0 Total 153 310 310 87 9 0 869 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 21 Hours of missing stability measurements in all stability classes: 4 76 I

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic eower Station Period of Record: October - Decernber2016 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T ( F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 10 10 2 0 0 0 22 NNE 23 3 0 0 0 0 26 NE 16 2 0 0 0 0 18 ENE 19 1 0 0 0 0 20 E 17 0 0 0 0 0 17 ESE 24 10 0 0 0 0 34 SE 12 8 1 0 0 0 21 SSE 20 12 2 0 0 0 34 s 23 12 1 1 0 0 37 SSW 6 10 0 0 0 0 16 SW 10 11 0 0 0 0 21 WSW 11 34 10 0 0 0 55 w 16 47 16 0 0 0 79 WNW 25 49 10 0 0 0 B4 NW 19 42 9 0 0 0 70 NNW 18 21 3 0 0 0 42 Variable 0 0 0 0 0 0 0 Total 269 272 54 1 0 0 596 Hours of calm in this stability class: 13 Hours of missing wind measurements in this stability class: 31 Hours of missing stability measurements in all stability classes: 4 77

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph} Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2* 0 0 0 0 0 2 NNE 5 0 0 0 0 0 5 NE 5 0 0 0 0 0 5 ENE 5 0 0 0 0 0 5 E 9 0 0 0 0 0 9 ESE 9 0 0 0 0 0 9 SE 4 0 0 0 0 0 4 SSE 4 0 0 0 a 0 4 s 4 1 0 0 0 0 5 SSW 11 l 0 0 0 0 12 SW 11 l 0 0 0 0 12 WSW 20 16 0 0 0 0 36 w 31 12 0 0 0 0 43 WNW 16 8 0 0 0 0 24 NW 13 2 0 0 0 0 15 NNW 6 1 0 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 155 42 0 0 0 0 197 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 27 Hours of missing stability measurements in all stability classes: 4 78

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Extremely Stable 150E't-33Ft Delta-T (F) Winds Measured at 33 Feet Wind Speed (in mph) Wind Direct.ion 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 0 0 0 0 0 3 NNE 2 1 0 0 0 0 3 NE: 1 0 0 0 0 0 1 ENE 6 0 0 0 0 0 6 E 2 0 0 0 0 0 2 ESE 3 0 0 0 0 0 3 SE 3 0 0 0 0 0 3 SSE 4 1 0 0 0 0 5 s 1 0 0 0 0 0 1 SSW 4 0 0 0 0 0 4 SW 9 0 0 0 0 0 9 WSW 20 16 0 0 0 0 36 w 17 4 0 0 0 0 21 WNW 9 1 0 0 0 0 10 NW 4 0 0 0 0 0 4 NNW 3 0 0 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 91 23 0 0 0 0 114 Hours of calm in this stability class: 14 Hours of missing wind measurements in this stability class: 3 Hours of missing stability measurements in all stability classes: 4 79

Peach Bottom Atomic Power Station licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-19 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 1 0 0 0 0 1 NE 0 1 1 0 0 0 2 ENE 0 1 0 0 0 0 1 E 0 3 0 0 0 0 3 ESE 0 0 2 1 0 0 3 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 s 0 0 0 0 0 0 0 SSW 0 () 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 o* 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 6 3 1 0 0 10 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 80

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Moderately Unstable - 316E't-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 1 0 0 0 1 ENE 0 1 0 0 0 0 1 E 0 2 1 0 0 0 3 ESE 0 2 1 0 0 0 3 SE 0 1 2 0 0 0 3 SSE 0 0 1 0 0 0 1 s 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 6 6 0 0 0 12 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 81

' !~- Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 0 0 0 0 3 NNE 1 0 0 0 0 0 1 NE 0 0 0 0 0 0 0 ENE l 1 1 0 0 0 3 E 0 3 0 0 0 0 3 ESE 0 1 1 0 0 0 2 SE 0 1 4 0 0 0 5 SSE 0 0 l 1 0 0 2 s 0 0 3 1 0 0 4 SSW 0 0 1 0 0 0 1 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 w 0 0 0 0 0 0 0 WNW 0 0 0 0 0 0 0 NW 0 0 0 0 0 0 0 NNW 0 0 1 1 1 0 3 Variable 0 0 0 0 0 0 0 Total 2 9 12 3 1 0 27 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 82

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Neutral - 316Ft-33Ft Delta-T {F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 B-12 13-18 19-24 > 24 Total N 6 15 17 7 0 0 45 NNE 1 6 5 4 0 0 16 NE 4 16 7 3 0 0 30 ENE 4 13 20 0 0 0 37 E 8 13 15 0 0 0 36 ESE 1 10 22 3 0 0 36 SE 2 8 26 11 0 0 47 SSE 1 11 30 19 2 0 63 s 2 8 22 22 4 0 58 SSW 1 6 9 7 0 1 24 SW 0 5 7 5 0 0 17 WSW 0 s 16 17 12 0 50 w 2 4 24 66 66 31 193 WNW 1 6 24 56 30 26 143 NW 0 16 40 67 29 11 163 NNW 2 13 27 33 40 11 126 Variable 0 0 0 0 0 0 0 Total 35 155 311 320 183 80 1084 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 12 Hours of missing stability measurements in all stability classes: 4 83

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T ( F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 7 9 3 0 0 23 NNE 3 7 5 2 0 0 17 NE 5 14 9 2 0 0 30 ENE 2 19 3 0 0 0 24 E 7 11 13 0 0 0 31 ESE 4 12 17 1 0 0 34 SE 1 13 14 12 0 0 40 SSE 2 13 22 3 0 0 40 s 2 10 29 3 0 2 46 SSW 1 6 24 10 0 0 41 SW 0 13 15 23 1 0 52 WSW 1 10 9 25 5 a 50 w 0 7 11 49 14 0 81 WNW 2 4 26 41 9 0 82 NW 3 8 29 39 8 0 87 NNW 5 8 30 17 0 0 60 Variable 0 0 0 0 0 0 0 Total 42 162 265 230 37 2 738 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 5 Hours of missing stability measurements in all stability classes: 84

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T ( F) Winds Measured at 320 Feet Wind speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 2.4 Total N 0 12 6 0 0 0 18 NNE 2 1 0 0 0 0 3 NE 1 1 l 0 0 0 3 ENE 1 3 0 0 0 0 4 E 3 3 1 l 0 0 ESE 1 4 0 0 0 0 5 SE 1 1 5 4 0 0 11 SSE 0 2 0 0 0 0 2 s l 5 6 2 1 0 15 SSW 0 7 5 1 0 0 13 SW 1 8 6 1 0 0 16 WSW 1 3 13 9 0 0 26 w 1 5 7 17 1 0 31 WNW 1 3 6 6 0 0 16 NW 2 5 14 6 0 0 27 NNW 2 6 6 0 0 0 14 Variable 0 0 0 0 0 0 0 Total 18 69 76 47 2 0 212 Hours of calm in this stability class: l Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 4 85

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unit 2 and 3 PSEG Nuclear, LLC Peach Bottom Atomic Power Station Period of Record: October - December2016 Stability Class - Extremely Stable - 316Ft-33E't Delta-T (F) Winds Measured at 320 Feet Wind Speed (in mph) Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 0 0 0 1 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 1 0 0 0 0 0 1 ESE 1 1 1 0 0 0 3 SE: 0 1 2 0 0 0 3 SSE 0 3 4 0 0 0 7 s 1 4 5 1 0 0 11 SSW 2 2 1 0 0 0 5 SW 1 1 3 5 0 0 10 WSW 1 2 13 3 0 0 19 w 2 5 6 7 0 0 20 WNW 1 3 0 1 0 0 5 NW 0 5 5 0 0 0 10 NNW 1 4 2 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 12 31 42 17 0 0 102 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 86

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC APPENDIX A: ERRATA DATA SECTION 87

Peach Bottom Atomic Power Station Unit 2 and 3 2014 ARERR Abnormal Gaseous Release Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC In the 2014 ARERR the reported dose rate and dose for the abnormal gaseous ground release from the Unit 2 Equipment Hatch Opening was incorrect. The calculation was incorrectly performed in the original IR (#2401232) and thus copied incorrectly into the annual report. The error was overly conservative (reported dose rate of 1.40E*OS mrem/ year to the infant lung). The correct dose rate for Infant lung Is 1.47E-06 % of limit, thus the teen lung dose rate Is most limiting at2.84E-06 % of the limit. The conservative dose for the year is 3.53E-07 mrem to the infant liver. (IR 2675790) 2015 ARERR Gaseous Effluent Release Point: Ground-Level In the 2015 ARERR the Ground Release Total Activity table in Attachment 2 contained an error. The activity reported for C-14 released from the Unit 2 and 3 Vent stacks was incorrect In the table in Attachment 2. The error was a transcription error, which lead to the Gaseous Effluent Summary table to also report an incorrect total C-14 activity released. The values are reported in a spreadsheet and a calculation is performed to determine the average release rate for the quarter and those values also need to be corrected. The reported dose and percentages of the dose limit (5.52E-01 mrem) are correct as the calculations were performed with the correct activities (IR 3999767). The tables should be reported as:

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Gaseous Effluents - Summary of All Releases Period: Januarv 1, 2015 through December 31, 2015 A. Fission & AetlvaUon Gases Units Quarter1 Quarter 2

1. Total Release Cl 1.56E+02 1.59E+02
2. Averaae release For !he Period I uCI/ S 2.01E+01 2.02E+01
3. Gamma Air Dose mrad 7.23E*02 7.09E-02
4. Beta Air Dose mrad 4.95E-02 4.66E*02
5. Percent of ODCM !lmil Gamma Air Dose 7.23E-01 7.09E-01 Beta Air Dose

.2.48E-01 2.43E*01 B. lodlnes

1. Total 1-131 Cl 2.45E-04 3.81E-04
2. Averaqe release For the Period uCl/s 3.14E-05 4.85E-05
3. Percent of ODCM limit C. Particulate
1. Particulates wilh T1/2 > 8 davs Cl 1.67E-04 G.81E-04
2. Averaae release For !he Period uCi/S 2.14E*05 8.66E-05
3. Percent of ODCM lfmlt D. Tritium
1. Total Release Cl 9.55E+OO 1.63E+01
2. Averaoe release Forlhe Period UC!fs 1.23E+OO 2.07E+OO
3. Percent of ODCM limit E. Gross Alpha
1. Total Release Ci

<LLD <LLD

2. Average release For the Pelfod uCi/s

<LLD <LLD

3. Percent of OOCM limit F. Carbon-14
1. Total Release Cl 8.69E+OO 9.26E+OO 2, Avera e release For the Period uClls 1.12E+DO 1.18E+OO G. lodlne-131 133 and 135, Tritium Carbon-14 & Particulate 1.0 an Dose rnrem 1.35E*01 1.43E*01
2. Percent ODCM limit B.97E*01 9.56E-01 89 Exelon Generation Company, LLC PSEG Nuclear, LLC Unit: Peach Bottom Est. Total Quarter3 Quarter4 Error%

1.03E+02 1.93E+02 3.51E+01 1.30E+01 2.43E+01 3.97E*02 8.82E-02 2.76E*02 6.04E*02 3.97e-01 8.82E*01 1.38E-01 3.02E*01 4.25E*04 8.49E-05 1.76E+01 I 5.35E*05 1.07E-05 1.86E-03 1.32E*04 1.94E+01 I 2.34E-04 1.67E*05 2.17E+01 3.28E+OO 1.11E+01 I 2.73E+OO 4.12E*01 <LLD <LLD 4.00E+02 I <LLD <LLD 8.SOE+DO 8.72E+OO 1.11E+OO 1.10E+OO 1.36E*01 1.35E 9.07E*01

Peach Bottom Atomic Power Station Licensee: Exelon Generation Company, LLC Unlt 2 and 3 PSEG Nuclear, LLC Gaseous Effluents Release Point: Ground-Level (Units 2 and 3 Reactor Building Exhaust Vents and Abnormal Releases) p rl d J 1 2015th e o : anuary, hDe roua1 camber 31, 20 15 U I P chB n t: ea ottom Nuclldes Released Continuous Mode Batch Mode Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter

1. Fission Gases Unit 1

2 3 4 1 2 3 4 Kr*85 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr*85m Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-87 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr*BB Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-133 Cl <LLD 4.52E+OO <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLO <LLD <LLD <LLD <LLD <LLD <LLD At-41 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Unidentified Cl 1.33E+02 1.26E+02 7.28E+01 1.63E+02 <LLD <LLD <LLD <LLD Total For Period Cl 1.33E+02 1.30E+02 7.28E+01 1.63E+02 <LLD <LLD <LLO <LLD

2. Iodines 1*131 Cl 2.03E-04 3.34E*04 3.55E*04 1.15E-05

<LLO <LLD <LLD <LLD 1-133 Ci 1.05E-03 2.on:-03 2.19e.03 <LLD <LLD <LLD <LLD <LLD 1*135 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total For Period Cl 1.25E-03 2.41E*03 2.54E*03 1.15E-05 <LLD <LLD <LLD <LLD

3. Particulates Sr-89 Cl

<LLD <LLD <LLD <LLO <LLD <LLD <LLD <LLD Sr*90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLO <LLD sa-140 Cl <LLD 1.74E-05 <LLO <LLD <LLD <LLD <LLD <LLD La-140 Cl <LLD <LLD <LLD <LLO <LLD <LLD <LLD <LLD Cr-51 Ci <LLD 2.02E.05 <LLD <LLD <LLO <LLD <LLD <LLD Mn-54 Ci <LLD 2.73E-OS 2.0BE-04 <LLD <LLD <LLD <LLD <LLD Co* SB Ci <LLD 2.38E-05 1.36E-04 <LLD <LLD <LLD <LLD <LLD Co*60 Cl 1.08E-04 5.14E-04 1.35E*03 3.70E-05 <LLD <LLD 3.76E-06 <LLD Mo-99 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD A11-11om Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Cl <LLD <LLD <LLD <LLD <LLD <LLD <I.LO <LLD Ce-144 Cl <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Cl <LLD 2.aoe-04 9.11E-04 <LLD <LLD <LLD <LLD <LLD Total For Period Ci 1.0BE-04 6.03E*04 1.70E*03 3.70E-05 <LLD <LLD 3.76E.Q6 <LLD

  • ~...
4. Tritium H-3 Cl 9.16E+OO 1.55E+01 1.86E+01 2.99E+OO

<LLD <LLD <LLD <LLD

s. Gross Aloha Gross Aloha Ci

<LLD <LLD <LLO <LLD <LLD <LLD <LLD <LLD

6. Carbon*14 C*14 Cl 2.61E-01 2.78E*01 2.64E-01 2.62E*01

<LLD <LLD <LLD <LLD 90

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: 2008-2016 Dose to Member of the Public Onsite Exelon Generation Company, LLC PSEG Nuclear, LLC ODCM 3.10.2 discusses the requirements for submission of the ARERR. Item *r under this section requires doses to members of the public located within the site boundary and all assumptions used in calculations to be incl.uded in the ARERR. Previously, this assessmen.t was included in the 'Dose Assessment' Report.(circa 2008 and earlier). When the ODCM was revised, the 'Dose Assessment' Reporting requirements was removed but ODCM 3.10.2.f was not. Therefore; an evaluation of gaseous dose to members of the public located within the site boundary was performed. Assumptions Previously, the Dose Assessment Report evaluated gaseous dose to members of the public due to activities inside the site boundary at vehicle checkpoint (114A}, 1300 feet N ofthe vent stacks. This onsite location was used for measuring Inhalation, plume and ground shine doses to the National Guardsmen and State Police. Continuous Occupation was assumed. These assumptions were determined to be valid and thus this location was used for the assessment below. Likely due to remapping of the meteorological sectors,.location 114A is located in the NNE sector, 1900 feet from the vent stacks. Meteorological data {MET) spanning the years from 2008-2016 was generated and the total gaseous activity released from both 2015 and 2016 calendar years were useci to calculate total body and skin dose. CY-PB-170-210 Gaseous Dose and Dose Rate Calculation" was used to calculate dose. Results Air dose due to gamma and beta radiation and total body and skin dose was calculated for MET data from 2015, 2013, 2010, ancl 2008 using the total gaseous activity released from 2015. Similar dpses were calculated for MET data from 2016 and the 10 year average using 2016 total gaseous activity released. C-14 was not used in the calculations as noble gassestontribute most significantly to these doses. Dose 201SMET 2013 MET 2010 MET 2008 MET Average 2015 ARERR Data Data Data Data Dosey (mrad) 1.75e-l 1.96e-l 1.21e-1 1.89e-1 1.72E-01 Data (without Doses (mrad) 1.18e-1 1.32e-1 . a.S9e-2 1;28e-1 1.16E-01 C*14) Dre (mrem) 1.69e*l 1.90e-1 1.23e-1 l.83e-1 1.66E-01 Dskln (mrem) 2:19e-1 2.46e-1 1.59e-1 2.37e-1 2.lSE*Ol DO!!e 2016 MET 2007-2016 Average % Difference of Averages Data MET Data (relative to avg value) 2016ARERR Dosev (mrad) 1.88e-1 1.72e-1 1.BOE-01 4.69% Data (without Doses (mrad) l.tie-1 1.16e~l 1.22E-01 4.65% C-14) Dre (mrem) 1.82e-1 l.66e-1 1.74E*Ol 4.56% Dskln (mrem) 2.35e-1 2.lSe-1 2.2SE-01 4.43% 91

Peach Bottom Atomic Power Station Unit 2 and 3 Licensee: Exelon Generation Company, LLC PSEG Nudear, LLC The total body and skin dose reported in 2008were1.29E-01 mrem and 1.73E-01 mrem, respectively. The doses in the above table are similar in magnitude, and do not vary significantly from the reported 2008 values. The differences are expected due to variances in MET data from year to year, and fall within the calculation assumptions. The impact of not calculating the dose to members of the public with activities within the site* boundary is minimal. The doses are less than those rep()rted In the 2016 ARERR, indicating that the ODCM defined location (1100 meters SSE ofthe roof vents) is a more conservative location for dose calculation. The assumption that National Guardsmen and State Police working onsite received the same dose as the member of the public off-site (as reported in the ARERRs from 2009-2015) is overly conservative and meets the purpose of ODCM 3.10.2.f. 92}}