ML17090A349

From kanterella
Jump to navigation Jump to search

Univ of Massachusetts, Lowell Research Reactor - Submittal of Response to Request for Additional Information Regarding the Renewal of Facility Operating License No. R-125
ML17090A349
Person / Time
Site: University of Lowell
(R-125)
Issue date: 03/31/2017
From: Bobek L
Univ of Massachusetts - Lowell
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML17090A348 List:
References
TAC MF7199
Download: ML17090A349 (1)


Text

Pinanski Building One University Avenue Lowell, Massachusetts 01854 tel:

978.934.3366 fax:

978.934.4067 url: www.uml.edu/radlab RADIATION LABORATORY March 31, 2017 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

REFERENCE:

University of Massachusetts-Lowell Research Reactor Docket No. 50-223; License No. R-125

SUBJECT:

Response to NRC letter dated February 1, 2017 - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-125 for the University of Massachusetts-Lowell Research Reactor (MF7199)

Please find the enclosed response summary for the above referenced request for additional information concerning the renewal of license No. R-125. Supporting documents are also enclosed.

Please direct any requests for additional information regarding this submittal to Mr. Leo Bobek, Reactor Supervisor at the above address.

I declare under penalty of perjury that the foregoing is true and correct.

Sincerely, Leo M. Bobek Reactor Supervisor, Radiation Laboratory

Enclosures:

Response to NRC RAI letter dated 02/01/17 PLTEMP Input File: uml21_plt_onb1MW_whcf.inp PLTEMP Input File: umlrr_flow21.inp MS Excel File: flow_dist.xlsx Cc:

Eben Allen, Project Manager Research and Test Reactor Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation