ML17088A624

From kanterella
Jump to navigation Jump to search
Request for Information for an NRC Design Bases Assurance Inspection (Program): Implementation of the Environmental Qualification Program Inspection Report 05000373/2017008; 05000374/2017008
ML17088A624
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 03/29/2017
From: Hausman G
Engineering Branch 3
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
References
IR 2017008
Download: ML17088A624 (7)


See also: IR 05000373/2017008

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION III

2443 WARRENVILLE RD. SUITE 210

LISLE, IL 60532-4352

March 29, 2017

Mr. Bryan C. Hanson

Senior VP, Exelon Generation Company, LLC

President and CNO, Exelon Nuclear

4300 Winfield Road

Warrenville, IL 60555

SUBJECT: LASALLE COUNTY STATION, UNITS 1 AND 2 - REQUEST FOR INFORMATION

FOR AN NRC DESIGN BASES ASSURANCE INSPECTION (PROGRAM):

IMPLEMENTATION OF THE ENVIRONMENTAL QUALIFICATION PROGRAM

INSPECTION REPORT 05000373/2017008; 05000374/2017008

Dear Mr. Hanson:

On June 26, 2017, the U.S. Nuclear Regulatory Commission (NRC) will begin a triennial

baseline Design Bases Assurance Inspection (Program) at the LaSalle County Station,

Units 1 and 2. This inspection will be performed in accordance with NRC Baseline

Inspection Procedure 71111.21N, Attachment 1.

The Design Bases Assurance Inspection will focus on the implementation of the electrical

equipment environmental qualification (EQ) program to verify you are maintaining the qualified

status of equipment during the life of the plant. The EQ components to be reviewed during this

baseline inspection will be identified during the inoffice preparation week that occurs prior to the

onsite inspection week.

The inspection will include a bagman trip to support selection of components and 2 weeks of

onsite inspection. The inspection team will consist of three NRC inspectors. The current

inspection schedule is as follows:

  • Bagman trip onsite week: June 5, 2017
  • Preparation week: June 19 - 23, 2017
  • Onsite inspection weeks: June 26 - 30, 2017; and

July 10 - 14, 2017.

Experience with previous baseline design inspections of similar depth and length has shown

that this type of inspection is extremely resource intensive, both for the NRC inspectors and the

licensee staff. In order to minimize the inspection impact on the site and to ensure a productive

inspection for both parties, we have enclosed a request for information needed for the

inspection.

B. Hanson -2-

It is important that all of these documents are up-to-date and complete in order to minimize the

number of additional documents requested during the preparation and/or the onsite portions of

the inspection. Insofar as possible, this information should be provided electronically to the lead

inspector. The information request has been divided into four groups:

  • The first group lists information necessary for our initial inspection scoping

activities. This information should be provided to the lead inspector no later than

May 8, 2017. Prior to the bagman trip, on May 22, 2017, the lead inspector will

communicate the initial selected set of approximately 12 EQ components.

  • The second group of documents requested is those items needed to support the

bagman trip. This set of documents should be available to the lead inspector

onsite on June 5, 2017.

  • The third group of documents requested is those items needed to support our

in-office preparation activities for the selected set of 6 - 9 EQ components. This

set of documents should be provided to the lead inspector at the Regional Office

no later than June 16, 2017. During the in-office preparation activities, the team

may identify additional information needed to support the inspection.

  • The last group includes the additional information above as well as plant specific

reference material. This information should be available to the team onsite on

June 26, 2017. It is also requested that corrective action documents and/or

questions developed during the inspection be provided to the lead inspector

as the documents are generated.

The lead inspector for this inspection is Mr. George M. Hausman. We understand that our

licensing contact for this inspection is Ms. Dwi Murray of your organization. If there are any

questions about the inspection or the material requested in the enclosure, please contact the

lead inspector at (630) 829-9743 or via e-mail at George.Hausman@nrc.gov.

This letter does not contain new or amended information collection requirements subject to

the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection

requirements were approved by the Office of Management and Budget, control number

3150-0011. The NRC may not conduct or sponsor, and a person is not required to respond

to, a request for information or an information collection requirement unless the requesting

document displays a currently valid Office of Management and Budget Control Number.

B. Hanson -3-

This letter, its enclosure, and your response (if any) will be made available for public inspection

and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document

Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public

Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

George M. Hausman, Senior Reactor Engineer

Engineering Branch 3

Division of Reactor Safety

Docket Nos. 50-373; 50-374

License Nos. NPF-11; NPF-18

Enclosure:

Design Bases Assurance Inspection

EQ Program Document Request

cc: Distribution via LISTSERV

B. Hanson -4-

Letter to Bryan C. Hanson from George M. Hausman dated March 29, 2017

SUBJECT: LASALLE COUNTY STATION, UNITS 1 AND 2 - REQUEST FOR INFORMATION

FOR AN NRC DESIGN BASES ASSURANCE INSPECTION (PROGRAM):

IMPLEMENTATION OF THE ENVIRONMENTAL QUALIFICATION PROGRAM

INSPECTION REPORT 05000373/2017008; 05000374/2017008

DISTRIBUTION:

Jeremy Bowen

RidsNrrDorlLpl3

RidsNrrPMLaSalle

RidsNrrDirsIrib Resource

Cynthia Pederson

Darrell Roberts

Richard Skokowski

Allan Barker

Carole Ariano

Linda Linn

DRPIII

DRSIII

ADAMS Accession Number: ML17088A624

OFFICE RIII E RIII RIII RIII

NAME GHausman:jw

DATE 03/29/17

OFFICIAL RECORD COPY

DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM DOCUMENT REQUEST

Inspection Report: 05000373/2017008; 05000374/2017008

Bagman Date: June 5, 2017

Inspection Dates: June 26 - 30, 2017, and

July 10 - 14, 2017

Inspection Procedure: IP 71111.21N, Design Bases Assurance Inspection (Program),

Attachment 1, Environmental Qualification (EQ) under 10 CFR

50.49 Programs, Processes, and Procedures

Lead Inspector: George M. Hausman, Senior Reactor Engineer, DRS

630-829-9743

George.Hausman@nrc.gov

I. Information Requested Prior to the Onsite Information Gathering/Bagman Week

The following information is requested by May 8, 2017, or sooner, to facilitate inspection

preparation. If you have any questions regarding this information, please call the team

leader as soon as possible. Please provide the information electronically in pdf files,

Excel, or other searchable formats, preferably on some portable electronic media (e.g.,

CD-ROM, DVD, etc.). The portable electronic media should contain descriptive names,

and be indexed and hyperlinked to facilitate ease of use. Information in lists should

contain enough information to be easily understood by someone who has knowledge

of light water reactor technology).

1. Risk-ranking of top 250 components required to meet environmental

qualifications from your site-specific probabilistic safety analysis (PSA)

sorted by Fussell Vesely Importance.

2. PSA listing of top ten risk-significant systems.

3. U.S. Nuclear Regulatory Commission Safety Evaluation Report(s) associated

with EQ.

4. Electronic copies of Updated Final Safety Analysis Report (UFSAR), Technical

Specifications, and Technical Specifications Bases. Specifically identify which

UFSAR sections address EQ (including seismic).

5. Identify the various EQ standards (including year, edition, or revision) that the

station is committed to meet.

Enclosure

DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM DOCUMENT REQUEST

6. Site procedures (i.e., and corporate, if applicable) associated with Title 10 of the

Code of Federal Regulations (10 CFR), Part 50, Section 49, Environmental

qualification of electrical equipment important to safety for nuclear power plants.

Include procedures for procurement of qualified equipment, maintenance of

qualified equipment, modification to qualified equipment (including Equivalency

or Commercial Grade Dedication (CGD) programs), and material storage and

shelf life controls.

7. Copy of EQ Design Basis Document, if applicable.

8. Copy of any open licensing commitments related to EQ, if applicable.

9. Equipment Qualification Master List (EQML). Specific issues to be identified

include: safety classification (safety-related or nonsafety-related), Regulatory

Guide 1.97 instrumentation, EQ qualification (e.g., DOR, NUREG 588,

10 CFR 50.49), original or replaced after implementation of 10 CFR 50.49,

and plant location.

10. List of any installed equipment removed from the EQML and basis for removal.

11. List of EQ solenoid valves that are normally continuously energized.

12. List or drawings of plant areas that are subjected to EQ, identifying design

(limiting) temperature, both normal and accident, high energy line break,

radiation levels, etc. that the associated equipment will have to be qualified to

meet EQ. If unit has obtained a power uprate (greater than 5 percent) provide

same information pre-update (earliest available if multiple uprates).

13. List of CGD evaluations performed, for which the dedicated parts have been

issued for installation (parts issued for the last 10 years) on EQ applications in

the plant. Include CGD evaluation number, name of part, component ID or

description of the component the part was issued to repair, work order, and

date issued or installed.

14. List of Corrective Action Documents related to the EQ program or EQ of specific

components for the last 5 years.

15. Current management and engineering organizational chart.

II. Information Requested (for the approximate 9 - 12 selected components) to be

Available by the Bagman Trip on June 5, 2017.

1. EQ summary report for each component/subcomponent.

2. Qualification Maintenance Requirement Sheet or equivalent.

3. List of corrective action documents associated with each of the selected

components for the last 5 years.

4. Photos of any component in containment or high radiation areas, if available.

2

DESIGN BASES ASSURANCE INSPECTION EQ PROGRAM DOCUMENT REQUEST

III. Information Requested (for the approximate 6 - 9 selected components) to be

Available by June 16, 2017, (will be reviewed by the team in the Regional office

during the week of June 19, 2017).

This information should be separated for each selected component, especially if

provided electronically (e.g., folder with component name that includes EQ files,

Qualification Test Reports, calculations, corrective action documents, maintenance

history, etc.).

1. EQ file, including associated Qualification Test Reports.

2. Vendor manual (electronic copy or availability of hard copy during inspection).

3. Preventive maintenance template.

4. Last performed work order (WO) for each associated EQ preventive

maintenance.

5. List of corrective maintenance WOs for the last 10 years. Include WO number,

date performed, and brief one line description.

6. If repair work (e.g., a motor rewind) was performed under a purchase order,

provide copy of the purchase order.

7. Thermal life calculation.

8. Any self-assessments of the EQ program in the last 3 years.

IV. Additional Information to be Provided on June 26, 2017 Onsite

1. During the in-office preparation activities, the team may identify additional

information needed to support the inspection. The lead inspector will provide

a list of the additional information needed during the week of June 19, 2017.

V. Information Requested to be Provided Throughout the Inspection

1. Copies of any corrective action documents generated as a result of the teams

questions or queries during this inspection.

2. Copies of the list of questions submitted by the team members and the

status/resolution of the information requested (provide daily by 2:00 p.m.

during the inspection to each team member).

If you have questions regarding the information requested, please contact the lead inspector.

3