1 NRR-PMDAPEm Resource From:

Distel, David J:(GenCo-Nuc) <David.Distel@exeloncorp.com>

Sent:

Tuesday, March 28, 2017 3:17 PM To:

Hughey, John Cc:

Seo, Timothy P:(GenCo-Nuc); Mokkapati, Sailaja:(GenCo-Nuc)

Subject:

[External_Sender] RE: Braidwood Station Response to question about FLEX equipment maintenance and testing.

John - The following response is provided by Braidwood.

Question:

Is Braidwood using the EPRI report regarding FLEX maintenance and testing?

Response

The Preventative Maintenance (PM) and Testing Program for FLEX equipment was developed using existing procedures and processes ER-AA-200, Preventative Maintenance Program, and WC-AA-120, Preventative Maintenance PM Database Revision Requirements. The program satisfies NEI 12-06 Section 11.5 by utilizing the following sources for maintenance and testing requirements:

A. Original Equipment Manufacturers Recommendations B. Exelon Corporate PM Templates which were developed using INPO AP-913 process and Electric Power Research Institute Report 3002000623 entitled Nuclear Maintenance Applications Center: Preventive Maintenance Basis for FLEX Equipment.

C. Operating Experience D. Material Aging and Shelf Life (including consumables and fluids)

These requirements were applied to equipment which "directly performs FLEX mitigation strategy for core cooling, containment or spent fuel cooling" (NEI 12-06, Section 11.5).

Any revisions to the scope or frequency of preventive maintenance or testing of FLEX equipment will be evaluated and authorized in accordance with ER-AA-200 and WC-AA-120.

Please us know if any additional information is needed.

Thanks.

Dave Distel From: Hughey, John [1]

Sent: Tuesday, March 28, 2017 1:37 PM To: Distel, David J:(GenCo-Nuc)

Cc: Spitzer, Douglas J:(GenCo-Nuc); Kuchenbecker, James P:(Contractor - GenCo-Nuc); Zurawski, Lisa M:(GenCo-Nuc);

Lynde, James M:(GenCo-Nuc); Merkle, Donald:(GenCo-Nuc)

Subject:

RE: Response to question about FLEX equipment maintenance and testing.

Dave, Could you please send me an e-mail for Braidwood that is similar to the e-mail below (for Byron)?

2

Thanks, John John Hughey Mitigation Strategies & SFP Instrumentation Project Manager, NRR/JLD/JOMB US Nuclear Regulatory Commission Phone: (301) 415-3204 Office: O13-H08 e-mail: john.hughey@nrc.gov From: Zurawski, Lisa M:(GenCo-Nuc) [2]

Sent: Tuesday, October 18, 2016 5:31 PM To: Hughey, John <John.Hughey@nrc.gov>; Distel, David J:(GenCo-Nuc) <David.Distel@exeloncorp.com>; Merkle, Donald:(GenCo-Nuc) <Donald.Merkle@exeloncorp.com>; Lynde, James M:(GenCo-Nuc)

<James.Lynde@exeloncorp.com>

Cc: Spitzer, Douglas J:(GenCo-Nuc) <douglas.spitzer@exeloncorp.com>; Kuchenbecker, James P:(Contractor - GenCo-Nuc) <James.Kuchenbecker@exeloncorp.com>

Subject:

[External_Sender] Response to question about FLEX equipment maintenance and testing.

Question: Is Byron using the EPRI report regarding FLEX maintenance and testing?

Response: The Preventative Maintenance (PM) and Testing Program for FLEX equipment was developed using existing procedures and processes ER-AA-200, Preventative Maintenance Program, and WC-AA-120, Preventative Maintenance PM Database Revision Requirements. The program satisfies NEI 12-06 section 11.5 by utilizing the following sources for maintenance and testing requirements:

A. Original Equipment Manufactures Recommendations B. Exelon Corporate PM Templates which were developed using INPO AP-913 process and Electric Power Research Institute Report 3002000623 entitled Nuclear Maintenance Applications Center: Preventive Maintenance Basis for FLEX Equipment.

C. Operating Experience D. Material Aging and Shelf Life (including consumables and fluids)

These requirements were applied to equipment which "directly performs FLEX mitigation strategy for core cooling, containment or spent fuel cooling" (NEI 12-06 11.5).

Any revisions to the scope or frequency of preventive maintenance or testing of FLEX equipment will be evaluated and authorized in accordance with ER-AA-200 and WC-AA-120.

Lisa Zurawski Byron Station Principal Regulatory Engineer 815-406-2991 Lisa.Zurawski@exeloncorp.com

3 This Email message and any attachment may contain information that is proprietary, legally privileged, confidential and/or subject to copyright belonging to Exelon Corporation or its affiliates ("Exelon"). This Email is intended solely for the use of the person(s) to which it is addressed. If you are not an intended recipient, or the employee or agent responsible for delivery of this Email to the intended recipient(s), you are hereby notified that any dissemination, distribution or copying of this Email is strictly prohibited. If you have received this message in error, please immediately notify the sender and permanently delete this Email and any copies.

Exelon policies expressly prohibit employees from making defamatory or offensive statements and infringing any copyright or any other legal right by Email communication. Exelon will not accept any liability in respect of such communications. -EXCIP

Hearing Identifier:

NRR_PMDA Email Number:

3421 Mail Envelope Properties (4BCCAD574B0D614096E6221C12ED97D8C382ABF7)

Subject:

[External_Sender] RE: Braidwood Station Response to question about FLEX equipment maintenance and testing.

Sent Date:

3/28/2017 3:16:59 PM Received Date:

3/28/2017 3:17:03 PM From:

Distel, David J:(GenCo-Nuc)

Created By:

David.Distel@exeloncorp.com Recipients:

"Seo, Timothy P:(GenCo-Nuc)" <Timothy.Seo@exeloncorp.com>

Tracking Status: None "Mokkapati, Sailaja:(GenCo-Nuc)" <Sailaja.Mokkapati@exeloncorp.com>