A Southern Nuclear February 17, 2017 Docket Nos.: 50-366 U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, D. C. 20555-0001 Charles R. Pierce Regulatory Affairs Director Edwin I. Hatch Nuclear Plant-Unit 2 40 Inverness Center Parkway Post Office Box 1295 Bim1ingham. AL 35242 205 992 7872 tel 205 992 760 I fax crpierce@southemco.com NL-17-0248 Relief Request Reactor Pressure Vessel Stud Inspection Ladies and Gentlemen:

Pursuant to 10 CFR 50.55a(g)(5)(iii), Southern Nuclear Operating Company (SNC) hereby requests Nuclear Regulatory Commission (NRC) approval of proposed Relief Request HNP-ISI-RR-05-01. This Relief Request will allow Hatch Nuclear Plant (HNP) to startup from their current refueling outage with a flaw indication on one reactor pressure vessel (RPV) stud, in the event this stud cannot be removed from the RPV for a code-compliant examination or replacement. provides proposed Relief Request HNP-ISI-RR-05-01. Enclosure 2 provides the Dominion Engineering, Inc. (DEl) evaluation supporting operation with one stud out of service.

To support the current HNP Unit 2 refueling outage, Nuclear Regulatory Commission approval is requested by February 17, 2017.

This letter contains no NRC commitments. If you have any questions, please contact Ken McElroy at 205.992.7369.

Respecil s~,

t C. R. Pierce Regulatory Affairs Director CRP/RMJ

U.S. Nuclear Regulatory Commission NL-17-0248 Page 2

Enclosures:

1. Proposed Relief Request HNP-ISI-RR-05-01
2. Dominion Engineering, Inc. (DEl) Evaluation cc:

Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bost, Executive Vice President & Chief Nuclear Officer Mr. D. R. Vineyard, Vice President-Hatch Mr. M.D. Meier, Vice President-Regulatory Affairs Mr. D. R. Madison, Vice President-Fleet Operations Mr. B. J. Adams, Vice President-Engineering Mr. G. L. Johnson, Regulatory Affairs Manager - Hatch RTYPE: CHA02.004 U.S. Nuclear Regulatory Commission Ms. C. Haney, Regional Administrator Mr. M. D. Orenak, NRR Project Manager-Hatch Mr. D. H. Hardage, Senior Resident Inspector-Hatch

Edwin I. Hatch Nuclear Plant - Unit 2 Relief Request Reactor Pressure Vessel Stud Inspection Proposed Relief Request HNP-ISI-RR-05-01 to NL-17 -0248 Proposed Relief Request HNP-ISI-RR-05-01

1. ASME Code Component(s) Affected Code Class:

ASME Section XI Code Class 1 Component Numbers:

Not Applicable Code

References:

ASME Section XI, 2001 Edition through 2003 Addenda, IWB-3515.2 Examination Category:

B-G-1 Examination Area:

Item Number(s):

Pressure Retaining Bolting Greater Than 2 in. (50.8 mm) in Diameter B6.20

2. Requested Date for Approval Approval is requested by February 17, 2017.
3. Applicable ASME Code Requirements ASME Section XI, 2001 Edition through 2003 Addenda, IWB-3515.2(c) Allowable Flaws for Volumetric Examination of Studs and Bolts The 2001 Edition through 2003 Addenda of ASME Section XI, IWB-3515.2(c) states: "Any flaw detected by the volumetric examination shall be investigated by a surface examination.

If confirmed to be a surface flaw, the standards of IWB-3515.1 shall apply. If not a surface flaw, the standards of IWB-3515.2(a) and (b) shall apply.

4. Reason for Request

A flaw indication was found on a Reactor Pressure Vessel (RPV) Stud during a volumetric examination (on 02/07/2017) on Unit 2 at the Edwin I. Hatch Nuclear Plant (hereinafter referred to as HNP2). During the lnservice Inspection (lSI) of the HNP2 RPV Studs (#1 through #56}, a circumferential flaw indication was identified on location #33. The indication is located at a distance of 41.7 inches from the top of the RPV Stud. This correlates to just below or equal to the surface of the reactor vessel flange. The indication is approximately one inch (1 ") in length. Qualified Personnel and Procedures (to the requirements of ASME Section XI Appendix VIII) were utilized to perform the ultrasonic examination using a oo beam angle (scanned from the top of the stud) to identify any/all abnormalities. Currently, there are no Appendix VIII Qualified Techniques available to size the indication in the RPV Stud.

In accordance with IWB-3515.2(c), flaws detected by volumetric examination shall be investigated by a surface examination. Due to the location of the flaw indication at or slightly below the reactor flange, removal of RPV Stud #33 is necessary to perform an ASME Section V, Mandatory Appendix 6 (Liquid Penetrant) or Mandatory Appendix 7 (Magnetic Particle) Surface Examination.

After discovery, an initial attempt was made to remove the stud prior to flooding the reactor cavity for fuel movement. This attempt was unsuccessful using on-site tooling. After draining down the reactor, two different methodologies (Basic Removal or Advanced Removal) are scheduled to remove the stud. The first attempt to remove the RPV Stud will utilize the E1-1 to NL-17-0248 Proposed Relief Request HNP-ISI-RR-05-01 "Basic Removal" Technique. This technique includes chasing the stud hole, applying an approved penetrant directly to the stud (includes soak time), installing a STAR adapter to the stud and attempting removal with an impact tool, finishing removal of the stud using a stud runner tool, and installing the new stud. If the "Basic Removal" Technique is unsuccessful, the "Advanced Removal (Full STAR Tooling)" Technique will be utilized. This technique includes installing an adapter plate, pumping an approved penetrant down the elongation hole and back up the threads, using a vibrator to agitate the stud (attached to the STAR Adaptor) prior to utilizing an impact tool to remove the stud, and installing a new stud.

These methods have been proven successful at other utilities. If both attempts are unsuccessful, significant additional planning will be needed for machining during the next refueling outage (2R25). This planning will be required to stage additional specialty tooling, establish contingencies, and determine methods to prevent potential damage to the RPV Head Flange.

5. Proposed Relief Request and Basis for Use Proposed Relief Request Pursuant to 10 CFR 50.55a(g)(5)(iii), a relief request is requested on the basis that compliance to the specified requirements in the Code are impractical based upon the time required to implement additional contingency actions.

Southern Nuclear Operating Company (SNC) requests relief from the surface examination requirement of IWB-3515.2(c) in the event that RPV Stud #33 cannot be removed for a code compliant surface examination. Several attempts are scheduled and planned to remove RPV Stud #33 during the current refueling outage (2R24), using available tooling and techniques. In the unlikely event the stud cannot be removed, HNP2 will be unable to create a detailed plan to mobilize/create special equipment, and successfully remove the stud without damaging the RPV Head Flange without significantly extending the current refueling outage.

Basis for Use An evaluation has been performed demonstrating that all applicable ASME Code allowable stresses (e.g., stud membrane and membrane plus bending stress, bearing stress, thread shear stress) are met with a single stud analytically assumed out of service, including subsequent operation with the expanded elongation tolerances previously developed for HNP2. The analysis considers the effects of both a single stud left detensioned and a stud that fails in service. This evaluation demonstrates that the structural and leakage integrity of the RPV Head Joint will be maintained until the next refueling outage (2R25), when the RPV Stud will be removed. A Class 1 System Leakage Test conducted before start-up (from 2R24) will verify the integrity of the RPV Head Joint. The system leakage test pressure for Class 1 Systems shall correspond to rated RPV pressure (at least 1,045 psig) and be attained at a rate in accordance with the approved Pressure/Temperature Limit Curves and approved procedures. After the test conditions have been attained, the VT-2 Examination will be performed. During plant operation, the bleed off line between the double a-ring seal is monitored by a pressure switch with an annunciator in the control room. This allows for continued monitoring of the RPV Head Flange integrity.

Based on the above discussion, the requirement to remove RPV Stud #33 during the current refueling outage (2R24) to perform the required surface examination (Liquid Penetrant or E1-2 to NL-17-0248 Proposed Relief Request HNP-ISI-RR-05-01 Magnetic Particle) represents an unusual difficulty. However, the inability to remove the stud in question does not adversely affect the design requirements of the RPV nor impose a decrease in the level of quality and safety of HNP2.

6. Duration of Proposed Relief Request This proposed relief request will be utilized from Mode 4 of the current refueling outage (2R24) until Mode 5 of the next refueling outage (2R25).

7. Precedents

None E1-3

Edwin I. Hatch Nuclear Plant - Unit 2 Relief Request Reactor Pressure Vessel Stud Inspection Dominion Engineering, Inc. (DEl) Evaluation

CALCULATION

~

Dominion fnyin~~rin_:y

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 1

of 41 RECORD OF REVISIONS Prepared by Checked by Reviewed by Approved by Rev.

Description Date Date Date Date 0

Original Issue J' r;; ~J,S!s~ f.C.9r

-r.c.~

1..1.~11 lr~a ( b1-

~ /U/~o/7

'2/1~ J goq "2-ftv(~,,

J.E. Broussard T.C. Ligon T.C. Ligon D.J. Gross Principal Enltinecr Enltinccr Engineer Principal Engineer The last revision number to reflect any changes for each section of the calculation is shown in the Table of Contents. The last revision numbers to reflect any changes for tables and figures are shown in the List of Tables and the List of Figures. Changes made in the latest revision, except for Rev. 0 and revisions which change the calculation in its entirety, are indicated by a double line in the right hand margin as shown here.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 2

of 41 TABLE OF CONTENTS Last Mod.

Section Page Rev.

1 PURPOSE..................................................................................................................................... 5 0

2

SUMMARY

OF RESULTS................................................................................................................. 5 0

3 INPUT REQUIREMENTS.................................................................................................................. 5 0

4 ASSUMPTIONS.............................................................................................................................. 6 0

5 ANALYSIS..................................................................................................................................... 7 0

5.1 Stud Primary Stress with One Stud Out of Service......................................................... 7 0

5.1.1 Average Stud Force......................................................................................... 8 0

5.1.2 Calculation of Stud Force Distribution.............................................................. 8 0

5.1.3 Primary Stress Comparison........................................................................... 10 0

5.2 Analysis of Closure Flange with Stud Out of Service.................................................... 10 0

5.2.1 Evaluation Methodology................................................................................. 10 0

5.2.2 Reactor Vessel Closure Flange Model........................................................... 11 0

5.2.3 5.2.4 5.2.2.1 Model Geometry......................................................................... 11 0

5.2.2.2 Model Boundary Conditions....................................................... 12 0

Analysis Cases............................................................................................... 12 Results Discussion......................................................................................... 12 5.2.4.1 RPV Closure Stresses................................................................ 13 5.2.4.2 RPV Stud Stresses..................................................................... 13 5.2.4.3 RPV Closure Flange Separation................................................ 13 5.2.4.4 Fatigue....................................................................................... 13 0

0 0

0 0

0 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 3

of 41 Last Mod.

Section Page Rev.

5.2.4.5 Emergency and Faulted Conditions............................................ 14 0

5.2.5 ANSYS Input Listings..................................................................................... 14 0

5.3 Quality Assurance Software Controls........................................................................... 14 0

6 REFERENCES............................................................................................................................. 15 0

A FINITE ELEMENT ANALYSIS INPUT LISTINGS.................................................................................. 23 0

A.1 File: _HATCH2.runs...................................................................................................... 23 0

A.2 File: _MACROS.HATCH2............................................................................................. 29 0

B SOFlWARE USAGE RECORDS...................................................................................................... 41 0

CERTIFICATION The original Edwin I. Hatch Nuclear Plant Unit 2 Reactor Vessel Design Report and previous amendments, as identified in Section 6 of this report, are supplemented by this amendment. The original Design Report and previous amendments, in conjunction with this amendment, reaffirm the structural integrity of the components in accordance with the 1968 Edition of Section Ill of the ASME Boiler and Pressure Vessel Code, with Addenda through Summer 1970. All requirements of applicable Code revisions are satisfied. This evaluation was performed under Purchase Order number SNG1015.1695.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 E. Broussard, ill, PE.

irginia Certificate No. 032963 2

(~ ZVt1--

Date PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 4

of 41 LIST OF TABLES Table No.

Table 1.

Table 2.

Table 3.

FEA Model Inputs Calculation of Primary Stresses in Reactor Vessel Studs, One Stud Out of Service Stress Increase Due to Stud Out of Service LIST OF FIGURES Figure No.

Figure 1.

Figure 2.

Figure 3.

Reactor Vessel Head Stud Geometry, One Stud Out of Service Hatch Unit 2 RPV Closure Flange FEA Model Overall View [1]

FEA Model Node Numbering and Section Cut Line Locations [1]

Last Mod.

Rev.

0 0

0 Last Mod.

Rev.

0 0

0 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 5

of 41 1

PURPOSE Dominion Engineering, Inc. (DEI) originally provided optimized tensioning and detensioning procedures for Plant Hatch in January 20 IS [I], along with design basis evaluations for expanded elongation tolerances. The purpose of this calculation is to provide an update to these evaluations that consider the effect of a single stud out of service. This analysis considers the stresses resulting from two conditions which bound the effects of a stud out of service: (I) operating with one stud left untensioned, and (2) the unlikely condition of a stud that is tensioned then fails in service.

2

SUMMARY

OF RESULTS The average stresses in the studs due to primary load conditions with one stud out of service were calculated using the methodology outlined in Section 5.I. As summarized in this section, all studs continue to meet ASME Code requirements for primary loads with one stud out of service.

The FEA model which was used to develop the current stud tensioning evaluations in DEI Report R-3937-00-0I [I] was used to perform an analysis ofthe closure flange with one stud out of service, as summarized in Section 5.2. The analysis results are summarized in Table 3. As demonstrated by the results in Table 3, operation ofthe Hatch Unit 2 RPV with one stud out of service does not result in any component of the RPV closure flange to exceed the design basis ASME Code allowables.

3 INPUT REQUIREMENTS The following inputs are required to calculate the average stresses in the studs due to primary load conditions with one stud out of service:

I.

The RPV design pressure is 1,250 psia and the design temperature is 575°F [I, Table 3-I].

2.

The RPV inner o-ring radius is 11I.O inches [I, Table 3-3].

3.

The RPV stud circle radius is 117.3I3 inches [I, Table 3-3].

4.

The number of studs in the Hatch Unit 2 RPV is 56 [I, Table 3-I].

5.

The stud shank OD is 6.0 inches, the stud shank ID is 1.0 inches, and the stud shank cross section area is 27.489 in2 [I, Table 3-1].

6.

The Sm allowable at design temperature for the RPV studs is 36.3 ksi (1, Table 3-3].

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 6

of 41 The following inputs are required for the FEA analysis of tensioning effects related to one stud out of service:

7.

Reactor vessel head and closure flange dimensions. The geometry of the model developed for this analysis is identical to the one used in the Reference [1]. The model parameters used in this FEA model are detailed in Table 1.

8.

Reactor vessel head and closure flange low alloy steel material properties. The material properties of the model developed for this analysis are identical to those used in Reference [1].

9.

ASME Code design basis summary. The design basis conditions for the RPV closure flange components updated to include the analyses performed in the 2015 tensioning optimization stress report are summarized in Table 2-1 of Reference [1]. This table includes the updated stress values as well as the appropriate ASME Code comparison and allowable stress value.

I 0.

Primary stress design basis values. The conditions evaluated in the 2015 tensioning optimization stress report do not impact primary conditions, and therefore they were not included. Using the original closure flange design basis report [2] (referenced in the 2015 analysis), the following limiting primary stress values are obtained:

a.

Closure head I head flange general membrane stress: 22.5 ksi compared to an allowable stress of 26.7 ksi (Sm) [2, p. A-16]

b.

Vessel closure shell I flange general membrane stress: 23.8 ksi compared to an allowable stress of 26.7 ksi (Sm) [2, p. A-16]

c.

Closure head I head flange local membrane + bending stress: 28.1 ksi compared to an allowable stress of 40.05 ksi (1.5Sm) [2, p. A-23]

d.

Vessel closure shell I flange local membrane+ bending stress: 28.2 ksi compared to an allowable stress of 40.05 ksi (1.5Sm) [2, p. A-29]

4 ASSUMPTIONS The following assumptions are used to calculate the average stresses in the studs due to primary load conditions with one stud out of service:

1.

The reactor vessel and head are rigid. This is consistent with the usual treatment of primary loads which only considers net forces and moments and not localization of stress from geometry and compliance effects. A consequence of this assumption is that the distribution of stud forces varies linearly with the distance from the neutral axis.

2.

The reactor vessel and head exert no contact forces on each other (i.e., the compression forces on the mating surfaces are neglected). These secondary forces serve to mitigate the redistribution of loads when studs fail, so this assumption conservatively maximizes the calculated maximum stud stress value.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 7

of 41

3.

As a simplifying assumption, each stud is individually treated as a point force. That is, each stud contributes no bending stiffness to the cross section as a whole.

4.

The design pressure is assumed to act out to the radius of the inner a-ring of the vessel.

The following assumptions are used for the FEA analysis of tensioning effects related to one stud out of service. These assumptions are consistent with analyses described in Reference [I].

5.

All vessel elements were assigned material properties appropriate for low carbon steel at ambient temperature: E== 27.9E6 psi and v== 0.3. All stud elements were assigned material properties appropriate for low alloy steel at ambient temperature: E== 29.9E6 psi and v== 0.3. The differences caused by differential thermal expansion of the stud and vessel are negligible and are not considered.

6.

The modulus of elasticity in the stud hole regions of the upper and lower flanges were de-rated by the ratio shown in Table I to account for the removed material in the stud holes.

7.

The contact between the nut and the washer is assumed to occur at a single point location. This is considered a reasonable assumption since the nut and washer mate at a spherical surface, and therefore come into contact all at once.

8.

Beam elements that are stiff in bending are used to impose flange rotation on the ends of the studs. Despite the presence of spherical washers between the nut and the upper flange, friction acts to "glue" the nut to the flange once the stud is pre loaded. At full pressure load, a modest amount of friction (!l < 0.1) has been demonstrated to be sufficient to transmit the bending stresses which arise from this boundary condition. Thus, the infinite friction assumption is concluded to be more realistic than the assumption of zero friction at the spherical washer.

9.

The interface between the head and vessel flanges was simulated by a row of line elements connecting the head and vessel flanges. The location of these interface elements was selected to act at a "reaction radius" empirically determined from the correlation between the model predictions and the actual stud elongation data using the existing tensioning procedure.

I 0.

All studs are assumed to be initially uniformly tensioned to the target stud elongation of 0.0397 inch, equivalent to a stud stress of 3 7. I 46 ksi [I, Table 3-I].

5 ANALYSIS 5.1 Stud Primary Stress with One Stud Out of Service The effect of a stud being out of service on the primary stress in the remaining studs is greater than simply increasing the design basis primary stress by the ratio of original to remaining studs. The change in restraint conditions caused by the inactive stud will tend to create a larger primary load in the studs adjacent to the inactive stud.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 8

of 41 We treat the studs as a single cross section loaded in bending by the pressure on the reactor head.

Assuming one stud is out of service, and that the resulting force distribution in the studs is a linear function of the distance from the neutral axis ofthe stud cross section, we enforce the static equilibrium equations on the studs. Note that the linear distribution assumption is a consequence of Assumption I. An Excel spreadsheet is used to facilitate solution of the equations which are developed.

5.1.1 Average Stud Force Ignoring for a moment that the 55 remaining studs are not uniformly distributed around the RPV closure, we can compute the average force in the studs according to the following equation. Assuming that the design pressure (in psig) acts out to the location of the inner o-ring radius (characterized by radius Ri), we have:

PA P(1rRn

{1235 psig){7!x11I.02 in 2 )

F=-" =

=

=869.2 kipS 55 55 55

[5-1]

This value will be used in computing the actual force (and, from there, stress) distribution among the studs in a later section. For comparative purposes, we note that when all studs are intact and tensioned, the corresponding average force is (55/56)*869.2 = 853.6 kips.

5.1.2 Calculation of Stud Force Distribution Because the out of service stud is located symmetrically about the x-axis, the neutral axis of bending for the remaining studs (considered as a whole) must be oriented parallel to they-axis in Figure 1. The offset Jfrom the center of pressure is still an unknown at this point, however. The solution for Jis achieved by writing the static equilibrium equations for the reactor head LFz = LF,-PA,= 0

[5-2]

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 9

of 41 where Fz = net force in the direction parallel to the stud lengths Mn = net moment about the neutral axis x; = x-coordinate of each stud per the axes in Figure 1

() = parallel offset of the neutral axis from the y-axis as shown in Figure 1 A 11 = area of the reactor head on which the pressure force acts The coordinates x; can be written in terms of the bolt-circle radius (R0 ) and B; as defined in Figure 1.

x, = Ro cos B,' where B, = e 5~

9

) X 2JT

[5-3]

At this point, we assume per Section 4 that the stud force varies linearly with its distance from the neutral axis. The mathematical form of the force distribution in the studs consequently may be expressed as follows, wherefis a constant F, = F + f(x, - 8)

[5-4]

Substituting Eq. [5-4] into the first ofEqs.[5-2] and taking advantage ofthe fact that LF = PA, yields I

8 = 5 1

5 L:x, = ~ L:cosB, i

I where Eq. [5-3] has been used for x;. Since 8is now known, we can substitute Eq. [5-4] into the second of Eqs. [5-2], resulting in the following

[5-5]

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 10 of 41 L(F+ f(x,-<>))(x, -<5)-PA,(-b') = 0 ~

i

[5-6]

The values forfand b'can be substituted directly back into Eq. [5-4], producing the force distribution for all studs. The final results appear in Table 2. Note that the highest stud force occurs at Stud Location Nos. 2 and 56, as might be expected since these are adjacent to the untensioned stud (No. 1).

5.1.3 Primary Stress Comparison The distributed primary stud forces are divided by the stud stress area of27.489 in2 (Input 5) to calculate the primary stud stresses. The maximum primary stud stress is calculated in Table 2 to be 32.8 ksi, which is less than the Sm allowable of 36.3 ksi; therefore, this condition is satisfied.

5.2 Analysis of Closure Flange with Stud Out of Service 5.2.1 Evaluation Methodology The effect of one stud out of service on the ASME Code comparison stresses in the reactor vessel closure flange components is evaluated using the same model used in the 2015 tensioning optimization stress report. The approach used to evaluate these conditions is to: (1) determine the stresses in the studs and vessel for the intact case and for the case of a single stud out of service under preload plus design pressure conditions, (2) determine the increase in the stresses when going from the intact to single stud out of service condition, (3) add the calculated increase in stress to the stress given in the design report which includes the effect of plant design transients, and (4) determine if the calculated single stud out of service condition stresses still meet ASME Code requirements.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 11 of 41 5.2.2 Reactor Vessel Closure Flange Model The simulation was perfonned using the finite element analysis model described in Appendix A of Reference [I]. The modeling methods are summarized in this section; greater detail on the specifics of the model is described in Reference [1].

5.2.2.1 Model Geometry The vessel shell, head and flange regions were modeled using SOLID45 (30 structural solid) elements with each row of elements corresponding to one stud pitch. Studs were modeled using BEAM4 (30 beam) elements which resist tensile loads and bending moments. A three dimensional model of the Hatch RPV closure flange was simulated as shown in Figure 2. The model considers half the circumference of the closure flange, with symmetry boundary conditions at the circumferential edges.

The 3-D BEAM4 elements used for the studs and tie bars require three real properties: area, moment of inertia, and thickness (used to calculate section modulus). The stud element real properties used in the analysis are reported in Reference [I]. Tie bar properties were selected so that the area is 1 00 times smaller than the area of the studs, and the moment of inertia is I 00 times greater than that of the studs.

This has the effect of making the tie bars rigid in bending (as they are being used, the elements have no shear deflection), so that the rotation of the flanges is imposed on the ends of the studs without affecting the stiffness of the adjacent solid elements.

The interface between the head and vessel flanges was simulated by a row of LINKS (30 spar) elements connecting the head and vessel flanges. The location of these interface elements was selected to act at a "reaction radius" empirically detennined from the correlation between the model predictions and the actual stud elongation data using the existing tensioning procedure.

The case of an untensioned stud is simulated by deleting the beam element representing that stud and adjusting the initial strains on the studs adjacent to the untensioned stud to produce the specified preload. If the spar elements simulating the vessel to head contact have axial tensile stresses in the pressurized condition, these elements are deleted and the coupled circumferential and radial constraints at these nodes are removed to simulate the fact that there is no longer a frictional restraining force at this location.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 12 of 41 5.2.2.2 Model Boundary Conditions The nodes at the bottom of the vessel shell were all fixed in the vertical and circumferential directions and allowed to move freely in the radial direction. Additionally, out of plane rotations (ROTX and ROTZ) were restrained on the nodes associated with the tie bar elements. The rotation of the flange was tied to the bending of the stud by coupling the rotational degree of freedom between the node at top of the stud beam element and the center node of the "tie bar" elements at the top ofthe flange.

As noted previously, symmetry boundary conditions were applied at the circumferential edges of the model. In addition, the stud and tie bar beam elements located at each end of the model (i.e., in the first and last planes) are assigned half of the area and moment of inertia as the rest of the studs because they lie on a plane of symmetry. Similarly, the LINK8 elements representing flange contact located at each end of the model are given half the area of the rest of the flange contact elements.

5.2.3 Analysis Cases Six cases are evaluated as follows:

Case AI Case A2 Case Bl Case B2 Case Cl Case C2 represents the preload condition with all studs intact represents the operating condition with the vessel at design pressure and with intact studs represents the case of one stud untensioned and with all other studs pre loaded to the specified initial stress same as Case B 1 with the vessel at design pressure represents the case of all studs pre loaded to the specified initial strain with one stud assumed to fail in service same as Case C 1 except the vessel is at design pressure 5.2.4 Results Discussion The results of the finite element analyses are summarized in Table 3. The increases in stress caused by the inactive stud are summarized, and the stresses are compared to the appropriate ASME Code allowables. As noted in Input 9, the ASME Code comparisons and allowables are taken from Table 2-1 of Reference [1]. The following evaluations are considered:

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 13 of 41 5.2.4.1 RPV Closure Stresses As shown in Table 3, the stud out of service has little to no impact on the stresses associated with General Primary Membrane Stress Intensity, Primary Local Membrane plus Bending Stress Intensity, and Maximum Stress Intensity Range. Each of these stress values remain below the appropriate ASME Code allowable stresses.

5.2.4.2 RPV Stud Stresses As shown in Table 3, the stud out of service has a modest immpact on the stresses associated with the stud Maximum Membrane and Maximum Membrane plus Bending stress. Each of these stress values remain below the appropriate ASME Code allowable stresses.

5.2.4.3 RPV Closure Flange Separation As shown in Table 3, the stud out of service causes an additional flange separation at the o-ring of 0.0078 inch. This increase does not impact an ASME Code allowable. The flange separation is less than the o-ring minimum springback of0.010 inch cited in Table 3-2 of Reference [I].

5.2.4.4 Fatigue Per Table 3, the stud out of service increases the maximum stress at: (I) the head flange/shell by 0.24 ksi, (2) the vessel flange/shell by 0.47 ksi and (3) the stud by 0.97 ksi; each of these increases are approximately I% of the previous design basis stress. According to Table 2-1 of Reference [1], the fatigue usage values in these components are as follows: (1) the head is 0.178, (2) the vessel is 0.679, and (3) the stud is 0.846. These fatigue usage values were calculated for the full service life of the component.

The impact of the 1% increase in stress for a single cycle of operation on these components is negligible. Referring to the fatigue curves in the design basis Code [7], Figures N-4 I 5A (vessel and head material) and N-4 I 6 (bolting material), it may be demonstrated for higher values of alternating stress that the number of allowable cycles is inversely proportional to the square of the increase in stress. Therefore, even if the components were operated for their full service life with the increase in stress resulting from one stud out of service, the increase in fatigue usage would be the square of the increase in stress, or 1.01 2 = 2%. The resulting values would remain below the Code allowable of 1.0.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 14 of 41 5.2.4.5 Emergency and Faulted Conditions Review of the design basis conditions evaluated in the original plant design basis report [2]

demonstrates that, for the RPV closure flange components, meeting the ASME Code requirements for normal and upset conditions described in previous sections of this calculation bounds the requirements for emergency and faulted conditions. This is demonstrated on pages A-ll through A-30 of Reference [2] as follows:

The emergency condition evaluated in Reference [2] is a vessel overpressure event. The evaluated pressure is I,350 psia, or a factor of 1.08 greater than the normal condition design pressure, but the stress allowables for emergency conditions are 1.2 times the normal condition allowables.

The faulted condition evaluated in Reference [2] is a pipe rupture event. The evaluated pressure is I,000 psia, which is lower than the normal condition design pressure.

5.2.5 ANSYS Input Listings The RPV closure flange stud tensioning analysis described in this section is performed using the ANSYS input listing files _HATCH2.runs, _MACROS.HA TCH2, and MACROS.DEI. The

_ HA TCH2.runs input listing defines parameters that are used by_ MACROS.HA TCH2 and MACROS.DEI to generate the geometry and run the stud out of service analysis cases. The input listings _HATCH2.runs and _MACROS.HATCH2 are provided in Appendix A.

MACROS.DEI is a proprietary input listing developed outside of the scope of this work. It is retained as an electronic file on a data disk [6] along with other software usage QA records required by the DEI QA program [4]. The contents ofthis data disk are listed in Appendix B. This data disk is retained with the project file for this task (Task 3944) and is available for on-site review by Southern Nuclear personnel.

5.3 Quality Assurance Software Controls The RPV closure flange stud tensioning analysis described in this calculation was performed on the "ANSYS-A" Dell Precision R7910 workstation, using Windows Server 2012 R2 Standard 64-bit operating system and ANSYS Version 15.0 which was verified on February 6, 2017, as documented in Reference [3]. This software is maintained in accordance with the provisions for control of software described in Dominion Engineering, Inc.'s (DEI's) quality assurance (QA) program for safety-related 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 15 of 41 nuclear work [4]. 1 In addition to QA controls associated with the procurement and use of the ANSYS software (e.g., maintenance of the ANSYS Inc. as an approved supplier of the software based on formal auditing and surveillance; formal periodic verification of ANSYS software installation), QA controls associated with all ANSYS batch input listings are also carried out by DEI. These include independent checks of a batch input listing each time it is used; review of all ANSYS Class 3 error reports and QA notices to assess their potential impact on a batch input listing; and independent confirmatory analyses2 to ensure that the project-specific application of the analysis is appropriate. The review of ANSYS error reports and QA notices as well as the project-specific check calculations are documented formally in a QA memo to project file [5].

The stud primary stress calculations performed in Table 2 were generated using Microsoft Excel 20 I 0 on a Dell Latitude E7440 with an Intel Core i7 processor and running Microsoft Windows 7. The one-time-use Microsoft Excel spreadsheet "Hatch 2 Stud Primary Stress Calc vO.xlsx" was prepared, checked, and reviewed in accordance with DEI's nuclear QA program manual [4] and is archived on the data disk associated with this calculation [6].

6 REFERENCES I.

DEI Report R-393 7-00-1, Rev. 0, "Reactor Vessel Tensioning Optimization Stress Report-Hatch Nuclear Plant Unit 2," January 2015.

2.

"Analytical Report for Hatch No.2 Reactor Vessel for Georgia Power Company," Combustion Engineering Report No. CENC-1232, Aprill975.

3.

Dominion Engineering, Inc. Software Test Report No. STR-9898-00-19, "ANSYS 15.0 Re-Verification Software Test Report." Revision 0, February 2017.

4.

Dominion Engineering, Inc. Quality Assurance Manual for Safety-Related Nuclear Work, DEI-002. Revision 18, November 2010.

5.

Dominion Engineering, Inc. Memorandum M-3944-00-01, Revision 0, "ANSYS Confirmatory Analysis and Review of Error Reports I QA Notices for C-3944-00-0 1, Rev. 0." February 2017.

6.

Dominion Engineering, Inc. Data Disk D-3944-00-01, Revision 0, dated February 2017.

1 DEI's quality assurance program for safety-related work (DEI-002) commits to applicable requirements of 10 CFR 21, Appendix 8 of 10 CFR 50, and ASMEIANSI NQA-1. This QA program is independently audited periodically by both NUPIC (the Nuclear Procurement Issues Committee) and NIAC (the Nuclear Industry Assessment Committee).

2 Confirmatory analyses for a given project may include comparison of model-computed stresses to theoretical closed-form solutions and other checks on model results.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 16 of 41

7.

ASME Boiler and Pressure Vessel Code,Section III - Rules for Construction ofNuclear Vessels, 1968 Edition with Addenda through Summer 1970.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 17 of 41 Table 1.

FEA Model Inputs Parameter Units Hatch Unit2 Stud and Vessel Parameters

-Number of Studs 56

-Stud Shank OD in 6.000

-Design Stud Stress Area in Shank in"2 27.489

- Calculated Stud Moment of Inertia in"4 63.568

- Membrane Stress, Preload Only ksi 35.58

-Corresponding Elongation in 0.038

- Design Pressure psia 1,250

- Stud Effective Length in 31.937 Tensioning Parameters

- Max Tensioner Pressure (new) psi n/a

- Optimized Sequence Final Pressure (new) psi 7,100

- Resulting Stud Stress ksi 37.15

- Tensioner CoeffiCient, Kt psi/in 5.232 Bolting Dimensions

- Stud Circle Radius in 117.313

- Stud Hole Diameter in 6.750

- Spherical Washer Radius of Curvature in 27.000

- Modulus Ratio in Hole Region 0.60 Vessel Flange Dimensions

- Flange IR in 109.690

- Inner 0-ring Mean Radius in 111.000

- Reaction Radius in 113.250

- Seating Surface Outer Radius in 113.750

- Flange OR in 122.625

- Z dim to ID Transition in

-18.000

- Z dim to OD transition in

-14.500 Vessel Shell Dimensions

- Shell IR in 110.720

- Shell thickness in 5.875

- Z dim to Bottom of Transition in

-21.090 Head Flange Dimensions

- Flange IR in 109.250

- Flange OR in 122.625

- Flange Top Fillet Radius in 2.750

- Z dim to Top of Flange in 24.375

- Z dim to Recess (inner) in 0.375

- Z dim to Recess (outer) in 0.375 Head Shell Dimensions

-Shell IR in 109.500

-Shell thickness in 3.188

- Z dim to Head Coord. Sys.

in

-7.250 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 18 of 41 Table 2.

Calculation of Primary Stresses in Reactor Vessel Studs, One Stud Out of Service Design Pressure, P, psig 1,235 Bok Code Radils, Ro ll7.313in Inner o-ring Radils, Ri 111.000 Average ilrce, Fbar 869.2 k.,s Studs Out ofSer.ice 1

Neutral axis oflSet, d

2 133 it Stud S~ss Area, A 27.489 Coefliciera f

-274.6 psv11 Nl.lllber ofStuds 56 Stud

!beta cos( !beta) cos"2 (!beta)

Fi S~ss (deg)

(kip)

(ksi) 1

-180 untensioned mtensioned wtensioned wtensioned 2

-174

-0.9937 0.99 90 1.8 32 80 3

-167

-0.9749 0.95 901.2 32 78 4

-161

-0.9439 0 89 900.2 32 75 5

-154

-0.9010 0 81 898 8 32 70 6

-148

-0.8467 072 897.0 32 63 7

-141

-0.7818 0 61 8949 32 56 8

-135

-0.7071 0.50 892 5 32 47 9

- 129

-0.6235 039 8898 32.37 10

-122

-0.5320 0.28 886 9 32.26 11

-116

-0.4339 0 19 883 7 32.15 12

-109

-0.3303 0 II 880.4 32.03 13

-103

-0.2225 0.05 876 9 31.90 14

-96

-0.1120 0.01 873.4 31.77 IS

-90 0.0000 0 00 8697 31.64 16

-84 0.1120 0 01 866 1 31.51 17

-77 0.2225 0 OS 862 6 31.38 18

-71 0.3303 0.11 859 1 31.25 19

-64 0.4339 0.19 855 8 31.13 20

-58 0.5320 0.28 852 6 31.02 21

-51 0.6235 0 39 849.7 30.91 22

-45 0.7071 0 so 847.0 30.81 23

-39 0.7818 0 61 844.6 30.72 24

-32 0.8467 0.72 842 5 3065 25

-26 0.9010 0.81 840 7 30 58 26

-19 0.9439 0.89 839.3 30.53 27

-13 0.9749 0.95 838 3 30.50 28

-6 0.9937 0.99 837.7 30.48 29 0

1.0000 1.00 837 5 30.47 30 6

0.9937 0.99 837.7 30.48 31 13 0.9749 0.95 838 3 30.50 32 19 0.9439 0.89 8393 30.53 33 26 0.9010 0.81 840.7 30.58 34 32 0.8467 0.72 842 s 30.65 35 39 0.7818 0.61 844 6 30 72 36 45 0.7071 0.50 847,0 30.81 37 51 0.6235 0.39 849,7 30.91 38 58 0.5320 0.28 852 6 3102 39 64 0.4339 0.19 855 8 31.13 40 71 0.3303 0.11 859.1 31.25 41 77 0.2225 0.05 862 6 31 38 42 84 0.1120 0.01 866.1 31 51 43 90 0.0000 0.00 8697 31.64 44 96

-0.1120 O.oJ 8734 31,77 45 103

-0.2225 0.05 876.9 31.90 46 109

-0.3303 0.11 880.4 32.03 47 116

-0.4339 0.19 883.7 32.15 48 122

-0.5320 0.28 886.9 32 26 49 129

-0.6235 0.39 889.8 32.37 so 135

-0.7071 0.50 892.5 32.47 51 141

-0.7818 0.61 894.9 32 56 52 148

-0.8467 0.72 897,0 32.63 53 154

-0.9010 0.81 898.8 32.70 54 161

  • 0.9439 0.89 900.2 32.75 ss 167
  • 0.9749 0.95 901.2 32.78 56 174
  • 0.9937 0.99 901.8 32.80 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 19 of 41 Table 3.

Stress Increase Due to Stud Out of Service SheD Stresses (ksi) (2)

Stud Stresses (ksQ Flange Stud Load Gen. Membrane Local Memb.+Bend.

MaximumS!

Max Memb+

Separation Load Condition Condition Case Head Vessel Head Vessel Head Vessel Membrane Bending (10"-3 in)

Preload Only Normal AI 0.07 0.28 23.82 18.11 24.60 18.48 37.10 81.56 14.7 Preload Only I Untensioned 81 0.09 0.28 23.83 18.10 24.61 18.49 37.10 81.59 14.7 Preload Only I Failed Cl 0.09 0.28 23.82 18.11 24.60 18.48 40.06 81.58 14.7 Preload+ Pressure Normal A2 22.13 23.49 36.93 34.17 37.02 33.94 34.91 97.92 21.2 Preload+ Pressure I Untensioned 82 22.13 23.49 37.12 34.52 37.21 34.31 37.34 97.98 29.1 Preload+ Pressure I Failed C2 22.13 23.49 37.17 34.63 37.26 34.41 39.30 98.89 26.6 Max. Increase from A2 (Cases 82 & C2) 0.00 0.00 0.24 0.46 0.24 0.47 4.40 0.97 7.8 Limiting Vessel Report Value (I) 22.50 23.80 28.10 28.20 64.00 47.40 45.30 95.40 New Maximum Value 22.50 23.80 28.34 28.66 64.24 47.87 49.70 96.37 Code Stress Limit Sm=

Sm=

1.5 Sm =

1.5 Sm =

3.0 Sm =

3.0 Sm =

2Sm =

2.7 Sm =

26.7 26.7 40.1 40.1 80.1 80.1 73.5 99.2 (I) Value taken from R-3937-00-01 Rev 0 [I] or from Refi:rence [2] as 15ted in Input 10.

(2) Local Membrane+ Bending and Maximum SI taken at cut lines 2, 3, 4, 5, 6, and 7. General Membrane SI taken at cut lines I and 8. (See Figure 3 ).

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Blackened Stud is Out of Service y

Neutral Axis Figure 1.

Reactor Vessel Head Stud Geometry, One Stud Out of Service Page 20 of 41 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 28,000's Nodal Plane Revision No.:

0 Page 21 of 41

-_2000's Nodal Plane

"'"1000's Nodal Plane l's Nodal Plane Figure 2.

Hatch Unit 2 RPV Closure Flange FEA Model Overall View [1]

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 22 of 41 269

--.+MoM.--- 4

-'":"H-+*-"""'-- 3

-...-+++++:---- 2 1 -/~++-,~-

11 15

/

1 5

Figure 3.

FEA Model Node Numbering and Section Cut Line Locations [1]

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 A

FINITE ELEMENT ANALYSIS INPUT LISTINGS A.1 File: _HATCH2.runs

/BATCH,LIST

/COM,

/COM, **********************************************************************************

/COM, Hatch Unit 2 Stud Out of Service Evaluation

/COM, **********************************************************************************

/COM,

/INP,_MACROS,HATCH2

/INP,JMACROS,DEI

/COM,

/COM, **********************************************************************************

/COM, PRE-RUN SETUP

/COM, **********************************************************************************

/COM,

/FILNAM,Tens-1

/SHOW,plots,grph

/TYPE,1,4

/PREP7

/TITLE, Hatch2 Reactor Vessel Tensioning

/COM, Define run parameters NT ~ 56 NV

  • 56 NPMAX
  • 56*3 TENSMX = 7 XS - 37146 XP
  • 7100 Pmax
  • 8500 X1
  • 0.9994 X2
  • 0.9854 Kt = XS*X1/XP RLMAX = NT+1
  • DIM,TENSAR,ARRAY,TENSMX,3

/COM,

  • DIM,MPBTMPI,ARRAY,5
  • DIM,MPBTMPC,ARRAY,5
  • DIM,MPBTMPO,ARRAY,S
  • DIM,TOTTMPI,ARRAY,S
  • DIM,TOTTMPO,ARRAY,5

/COM,

! Total number of studs in model

! Total number of studs in real vessel

! Max number of studs any sequence

! Max number of Tens-* routines

! Final stud stress target for old tensioner

! Corresponding tensioner pressure

! Tensioner pressure cap

! Empirical correction factor (init guess)

! Empirical correction factor (init guess)

! Relate tensioner pressure to stud stress

! Number of data items in RLIST (from ENDPOST

/COM,

      • TOGGLE TENSIONING ROUTINES ***

/COM,

/COM,

/COM macro)

/COM, To set tensioning routine I (Tens-!) to RUN, toggle TENSAR(I,1)=1 To set tensioning routine I (Tens-!) to OFF, toggle TENSAR(I,1)~0 TENSAR(I,2) is number of cyclic symmetry slices (=1 for full model)

TENSAR(I,3) is number of passes thru OPTLOOP for Tens-! (max of 7) for Tens-!

/COM,

/COM, TENSAR(1,1)*1 RUNMORF

= 1

/COM, STENSAR(1,2)*1 STENSAR(1,3)*1

! RUNMORF=1 to run out of service stud cases

  • DIM,PLIST,ARRAY,NPMAX,4
  • DIM,RLIST,ARRAY,NT,RLMAX
  • DIM,RSAVE10,ARRAY,NV/2+1,RLMAX,6

/COM,

/COM,

/COM, **********************************************************************************

/COM, GEOMETRY FIGURES

/COM, **********************************************************************************

/COM,

/COM, Make 1/2 model to lay down 'Appendix A' plots NT - NV/2+1

! Total number of studs in model

/COM, Clear the boundary conditions and re-do the geometry.

/PREP7 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page ---=23=-- of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

  • USE,GEOM,O

! Create geometry

/TITLE, Hatch2 Reactor Vessel Tensioning

/VIEW,1,1,1,1 ESEL, S, TYPE,,1 NSLE

/COLOR,NUM,BLAC,1

/TRIAD,OFF

/DIST,1,1.5*HFOR

/FOCUS,1,-HFOR/4,-65,-HFOR/2.1 EPLO ESEL,S,ELEM,,41,290 ESEL,A,ELEM,,1041,1290 NSLE

/PNUM,MAT,1

/NUM,1

/AUTO EPLO ESEL,S, TYPE,,1 ESEL,R,ELEM,,1,1000 NSEL,S,NODE,,1,1000

/VIEW EPLO

  • DO,I,1,11

/COLOR,NUM,WHIT,I

  • ENDDO

/NUM

/PNUM, ELEM,1 ESEL,S,ELEM,,502,506 ESEL,A,ELEM,,1502,1506

  • REPEAT,4,,,,1000,1000 NSLE NSEL,U,NODE,,361,4361,1000

/VIEW,1,1,1,1

/AUTO EPLO

/VIEW,1, -1,1,5

/NUM,2 ESEL,S,ELEM,,501 NSLE EPLO

/USER

/DIST,1,5.75 ESEL, S, TYPE,,1 ESEL,A,ELEM,,501 NSLE EPLO ALLSEL

/AUTO

/COLOR,DEFA

/NUM FINISH

/COM,

/COM, 0

/COM, **********************************************************************************

/COM, TENSIONING ROUTINE 1: INITIALIZE MODEL

/COM, **********************************************************************************

/COM,

/COM,

/PREP?

NT

  • 10
  • USE,GEOMCLUP
  • USE,GEOM,O FINISH

/COM,

/COM, Do initial sets at final

/COM, Tension all studs except PP

  • NT NP D 2 TT
  • 1
  • USE,ZEROIT
  • DD,I,1,NT PLIST(I,1)

PLIST(I, 2)

  • ENDDO I

= XP

! Total number of studs in model

! Create geometry pressure to solve for X1 and X2 in one set and then retension stud 10

! Number of studs in each set

! Number of sets in this sequence

! Number of sets to achieve one-pass tens.

! Load PLIST column 1 with stud numbers

! Load PLIST column 2 with ref. tens. press.

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 24

--=-=--- of 41 FX 703.657.7301

Dominion £n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01

  • DO,l,NT+1,NT*2 PLIST(I, 1) = 10 PLIST(I, 2)
  • XP PLIST(I,4) = 1.0
  • ENDDO
  • IF,TENSAR(1,1),GT,O.S,THEN Revision No.:

0

! Load PLIST column 1 with stud numbers

! Load PLIST column 2 with ref. tens. press.

! Load PLIST column 4 with retens. flag

  • USE,GOSOLV, 'Hatch2','Tens-1',1

! Solve model X1 a X1*XS/RLIST(10,3)

! X1 is ref. stress/av. stud stress - single stud X2 - X1*XS/RLIST(1,3)

! X2 is ref. stress/av. stud stress - all studs Kt = XS*X1/XP

! Relate tensioner pressure to stud stress

  • ENDIF

/COM,

/COM,

/COM, **********************************************************************************

/COM, TENSIONING ROUTINE 10: RUN MISSING OR FAILED STUD CASES

/COM, **********************************************************************************

/COM,

/COM,

/FILNAM,Tens-10

/COM, Change over to a half model for missing stud runs

/PREP7

  • USE,GEOMCLUP NT = NV/2+1
  • USE,GEOM,O FINISH Kt = XS*X2/XP

/COM, Tension all studs in one pass PP =NT NP z 1 n = 1

  • USE,ZEROIT
  • DO,I,1,PP PLIST(I, 1) = I PLIST(I,2) = XP
  • ENDDO
  • USE,GOSOLV, 'Hatch2', 'Tens-10',1 SAVE,,A1
  • DO,I,1,NT
  • DO,J,1,RLMAX RSAVE10(I,J,1) = RLIST(I,J)
  • ENDDO
  • ENDDO
  • USE,ZEROIT I*1
  • USE,PSOLV, 'Hatch2','A2',2.0,1235 SAVE,,A2
  • DO,I,1,NT
  • DO,J,1,RLMAX RSAVE10(I,J,2) = RLIST(I,J)
  • END DO
  • ENDDO
  • USE,ZEROIT I=1

/COM, BEGIN SOLUTION PHASE

/SOLU ANTYPE,STATIC,REST SFDELE, ALL, ALL EKILL, 502

! Total number of studs in model

! Create geometry

! Relate tensioner pressure to stud stress

! Number of studs in each pass

! Number of passes

! Number of passes to achieve one-pass tens.

! Load PLIST column 1 with stud numbers

! Load PLIST column 2 with ref. tens. press.

! Solve model - Case A1

! Solve model - Case A2

/TITLE, Hatch2 Reactor Vessel - Case C1 - Preload Only TIME,3.0 SOLVE FINISH

/POST1 SET I I I

I 3. 0

  • USE,POSTER
  • USE,ENDPOST FINISH SAVE,,C1
  • DO,I,l,NT
  • DO,J,1,RLMAX RSAVElO(I,J,S)
  • RLIST(I,J)
  • ENDDO
  • ENDDO
  • USE,ZEROIT 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 25

--=;....__- of 41 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 1=1

  • USE,PSOLV, 'Hatch2','C2',4.0,1235 SAVE,,C2
  • DO,!, 1, NT
  • DO,J,l,RLMAX RSAVE10(I,J,6)
  • RLIST(I,J)
  • ENDDO
  • ENDDO Revision No.:

0

! Solve model - Case C2

/COM, Check for flange contact links which came out of compression LCHG

  • 0
  • DO,I,l,NT
  • IF,RLIST(I,lO),GT,O,THEN LCHG = 1.0

/PREP7 EKILL,I*l000-499 CPDELE,I CPDELE,l00+I FINISH

  • ENDIF
  • ENDDO
  • IF,LCHG,EQ,l.O,THEN
  • USE,ZEROIT I*l
  • USE,PSOLV, 'Hatch2', 'C2',5.0,1235 SAVE,,C2A
  • DO,I,l,NT
  • DO,J,l,RLMAX RSAVE10(I,J,6)

D RLIST(I,J)

  • ENDDO
  • ENDDO
  • ENDIF

! EKILL 501 El. in row

! Re-Solve model - Case C2

/COM, Clear the boundary conditions and

/PREP7 re-do the geom.

SFDELE,ALL,ALL CPDELE,ALL,ALL EDELE,ALL NDELE,ALL

  • USE,GEOM,O FINISH

/FILN, Tens-lOB

/COM, Tension all studs in one pass PP = NT-1 NP

  • 1

! Create geometry except stud 1

! Number of studs in each pass

! Number of passes n = 1

! Number of passes to achieve one-pass tens.

  • USE,ZEROIT
  • DO,I,l,PP PLIST(I, 1) = I+l PLIST(I, 2) = XP
  • ENDDO

! Load PLIST column 1 with stud numbers

! Load PLIST column 2 with ref. tens. press.

  • USE,GOSOLV, 'Hatch2', 'Tens-lOB',1 SAVE,,Bl
  • DO,I,l,NT
  • DO,J,l,RLMAX RSAVE10(I,J,3)
  • RLIST(I,J)
  • ENDDO
  • ENDDO
  • USE,ZEROIT I*l

! Solve model - Case Bl

  • USE,PSOLV, 'Hatch2','B2',2.0,1235

! Solve model -Case B2 SAVE,,B2

  • DO,I,l,NT
  • DO,J,l,RLMAX RSAVE10(I,J,4)
  • RLIST(I,J)
  • ENDDO
  • ENDDO

/COM, Check for flange contact links which came out of compression LCHG

  • 0
  • DO,I,l,NT
  • IF,RLIST(I,lO),GT,O,THEN LCHG = 1.0

/PREP7 EKILL,I*l000-499 CPDELE,I CPDELE,lOO+I 12100 Sunrise Valley Drive, Suite 220

! EKILL 501 El. in row Reston, VA 20191 PH 703.657.7300 Page 26 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 FINISH

  • ENDIF
  • ENDDO
  • IF,LCHG,EQ,1.0,THEN
  • USE,ZEROIT I=1 Revision No.:

0

  • USE,PSOLV, 'Hatch2', '82',3.0,1235

! Re-Solve model - Case B2 SAVE,,B2A

  • DO,I,1,NT
  • DO,J,1,RLMAX RSAVE10(I,J,4) = RLIST(I,J)
  • ENDDO
  • ENDDO
  • ENDIF

/COM, Check again for flange contact links which came out of compression LCHG c 0

  • DO,I,1,NT
  • IF,RLIST(I,10),GT,O,THEN LCHG = 1.0

/PREP7 EKILL,I*1000-499 CPDELE,I CPDELE,100+I FINISH

  • ENDIF
  • ENDDO
  • IF,LCHG,EQ,1.0,THEN
  • USE,ZEROIT I*1

! EKILL 501 El. in row

  • USE,PSOLV, 'Hatch2', '82',4.0,1235

! Re-Solve model - Case 82 SAVE,,828

  • DO,I,1,NT
  • DO,J,1,RLMAX RSAVE10(I,J,4) = RLIST(I, J)
  • ENDDO
  • ENDDO
  • ENDIF FINISH

/COM, Clear the pressure boundary conditions

/PREP7 SFDELE,ALL,ALL FINISH

  • USE,ZEROIT
  • ENDIF

/COM,

/TITLE, Hatch2 Reactor Vessel Tensioning FINISH SAVE

/COM,

/COM, **********************************************************************************

/COM, PRINT RESULTS

/COM, **********************************************************************************

/COM,

/COM, Print contents of PSAVE and RSAVE arrays

/OUT,RESULTS,OUT

/NOPR

  • IF,RUNMORF,EQ,1,THEN
  • USE,PRINTENS,'PSAVE10', 'RSAVE10',6,'Stud OOS',O
  • ENDIF

/OUT

/GOPR FINISH

/COM,

/COM, **********************************************************************************

/COM, RUN COMPLETE

/COM, **********************************************************************************

/COM,

/FILN,Tens-0 PARSAV,ALL

/COM, Do some file cleanup

/SYS, del CMMAKER

/SYS, del ENDPOST

/SYS, del GEOM 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 27

-==-- of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01

/SYS, del GEOMCLUP

/SYS, del GODETEN

/SYS, del GOSOLV

/SYS, del OPTLOOP

/SYS, del POSTER

/SYS, del POSTER2

/SYS, del POSTER3

/SYS, del PRINTOLR

/SYS, del PRINTENS

/SYS, del PSOLV

/SYS, del READS!

/SYS, del ZEROIT

/SYS, del NPL

/SYS, del linrept

/SYS, del *.dbs

/SYS, del *.stat

/SYS, del *.osav

/SYS, del *.PCS

/SYS, del *.PVTS

/SYS, del *.BCS

/SYS, del *.full

/SYS, del file.log

/SYS, del Tens-1.*

/SYS, del Tens-lO.e???

/EXIT 12100 Sunrise Valley Drive, Suite 220 Revision No.:

0 Reston, VA 20191 PH 703.657.7300 Page 28 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 A.2 File: _MACROS.HATCH2

/COM, --------------- MACROS.HATCH2, Revision 1, Created February 2017 ----------------

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE GEOMETRY MACRO

/COM, ----------------------------------------------------------------------------------

/COM,

  • CREATE, GEOM

/COM, ------------------------------------------------------------------

/COM, GEOMETRY AND RUN PARAMETERS

/COM, ------------------------------------------------------------------

/COM, Loads and Material Properties Esteel = 27.9E6 Ds 6.000 As

- 27.489 Is

- 63.568 Ls

= 31.937 Estud - 29.9E6

/COM,

/COM, SCR NOs SWRC Ehole

/COM, Bolting Dimensions

= 117.313

= 6.750

= 27.00

= 0.60*Esteel

/COM, Vessel Flange VFIR

= 109.690

! CBIR

  • 0.000

!ORR

= 111.00 SSOR

= 113.25 VFOR

- 122.625

! ZVFS

=

0.000

! ZBCB

=--0.000 ZVIT

=-18.00 ZVOT

--14.50 Vessel Shell

= 110.72 5.875

=-21.090 Dimensions Dimensions

/COM,

/COM, VSIR VSTH ZVTR

/COM,

/COM, HFIR HFOR HFFR ZTHF ZHFRI ZHFRO Head Flange

- 109.25 Dimensions

- 122.625 2.750

- 24.375 z

0.375

= 0. 375 Head Shell

- 0.000

= 0.000

- 0.000

- 0.000 Flange Transition

! /COM,

! /COM,

! RTCS

! ZTCS

! IRTR

! ZUIC

/COM,

/COM, HSIR HSTH ZHCS AHT

/COM,

/COM, Head Shell

- 109.50 Dimensions

/COM,

/COM, At It 3.188

= -7.250

- 19.0

- As/100

  • Is*100 12100 Sunrise Valley Drive, Suite 220

! Young's modulus (psi)

! Stud shank diameter (in)

! Stud area (inA2)

! Stud mom. of I (inA4)

! Stud effective length (in)

! Tune Estud or Ls to get right effective L

! Stud Circle Radius (in)

! Stud Hole diameter (in)

! Spherical Washer Rad. of Curvature

! Derate in stud hole regions

! Vessel flange inner radius (in)

(in)

! Core Barrel groove inner radius (in)

! Inner 0-Ring radius (in)

! Seating Surface outer radius (in)

! >>> TUNE REACTION RADIUS <<<

! Vessel flange outer radius (in)

! Z dimension to vessel flange surface (in)

! Z dimension to bottom of Core Barrel groove

! Z dim to vessel inside trans. (120's row)

! Z dim to vessel outside trans. (130's row)

! Vessel shell inside radius

! Vessel shell thickness

! Z dimension to bottom of vessel transition

! Head flange inner radius

! Head flange outer radius

! Head flange top fillet radius

! Z dimension to top of head flange

! Z dimension to head flange recess - inner

! Z dimension to head flange recess - outer

! Radial dimension to Transition Coordinate System

! Z dimension to Transition Coordinate System

! Inner radius of transition area

! Vertical rise of OD Transition

! Head shell inner radius

! Head shell thickness

! Z dimension to Head Coordinate System

! Approximate start of head shell region

! Arbitrarily small tie bar area (inA2)

! Arbitrarily large tie bar mom. Of i (inA4)

Reston, VA 20191 PH 703.657.7300 Page 29

--='---- of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Dt z Ds*100

! Arbitrarily large tie bar diameter (in)

RLTH a 0.005 Ar

  • As*100*(RLTH/Ls)

! Reaction link thickness (in Z direction)

! Reaction link area tuned for stiffness

/COM,

/COM, 100 times greater than stud (inA2)

/COM, ------------------------------------------------------------------

/COM, MATERIAL PROPERTIES

/COM, ------------------------------------------------------------------

/COM, Set types, mats, and reals

/COM, Element types ET,1,50LID45 ET, 2, LINKS ET,3,BEAM4 Solids - vessel (no associated real props)

Links - for reaction (REALS: AREA,ISTRN)

Beams - studs (A,IZZ,IYY,TKZ,TKY,THETA,ISTRN)

/COM,

/COM, Material properties

/COM, Material 1 for GENERAL USE MP, EX,1, Esteel MP,NUXY,1,0.30

/COM,

/COM, Material 2 for STUD ELEMENTS MP, EX, 2, Estud MP,NUXY,2,0.30

/COM,

/COM, Material 3 for STUD HOLES MP, EX, 3, Eho 1 e MP,NUXY,3,0.30

/COM,

/COM, REAL PROPERTIES

/COM, R,1,0 R,2,Ar Real 1: Dummy real for solid elements Real 2: Reaction links R,3,Ar/2 R,4,At,It,It,Dt,Dt,O R,S,At/2,It/2,It/2,Dt,Dt,O R,11,As,Is,Is,Ds,Ds,O

  • REPEAT,NT,1 Real 3: Cutting plane reaction links Real 4: Tie bars

/COM,

/COM, Real 5: Cutting plane tie bars Real 11:Stud elements Assign different reals to each stud

/COM, ------------------------------------------------------------------

/COM, NODE DEFINITION

/COM, ------------------------------------------------------------------

/COM,

  • AFUN,DEG

! Cartesian on lower mating surface

/COM, Establish coordinate systems LOCAL,20,0,0,0 LOCAL,21,1,0,0,0,0,-90,0

! LOCAL,22,1,RTCS,ZTCS LOCAL,23,1,0,ZHCS LOCAL,24,2,0,ZHCS

! Cylindrical on lower mating surface (z up)

! Cylindrical system 1 for head curvature

! Cylindrical system 2 for head curvature

! Spherical system for head stresses

/COM,

/COM, Define keypoints on theta - 0 plane CSYS,20 BOTZz-100+ZVTR N,1,VSIR,BOTZ N,S,VSIR+VSTH,BOTZ N,81,VSIR,BOTZ+100 N,BS,VSIR+VSTH,BOTZ+100

/COM,

! SHELL I.R. AT BOTTOM OF MODEL

! SHELL O.R. AT BOTTOM OF MODEL

! SHELL I.R. AT BOTTOM OF FLANGE

! SHELL O.R. AT BOTTOM OF FLANGE

/COM, DEFINE FEATURES ON MATING SURFACE N,161,VFIR,O

! Flange inner surface N,162,(VFIR+IORR)/2,0

! "Core barrel groove inner surface" N,163,IORR,O

! Inner a-ring radius N,164,RR,O

! Reaction radius N,165,SSOR,O

! Outer limit of seating surface N,166,SCR-NDs/2,0

! Bolt hole inner edge N,167,SCR,O

! Bolt circle N,168,SCR+NDs/2,0

! Bolt hole outer edge N,169,VFOR,O

! Flange outer surface flwdth

  • HFOR-HFIR

! Flange width - head flwdtv - VFOR-VFIR

! Flange width - vessel iormo - RR-IORR

! Inner a-ring moment arm

/COM,

/COM, COPY FEATURES THROUGH VESSEL FLANGE 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page ---=-30=-- of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 NGEN,2,-10,161,169,1,0,(ZTHF-Ls)/2 NGEN,2,-20,161,169,1,0,ZTHF-Ls NGEN,2,-50,161,169,1,0,ZVOT FILL,151,156,,,,2,-10

! Copy mating surf. thru lower flange (150's)

! Copy mating surf. thru lower flange (140's)

! Make 110's row for O.D. feature

! Even out 150's and 140's row FILL,111,117 FILL, 116,118 NGEN,2,-20,111,117,1,0,(ZVIT-ZVOT)

! Make 90's row for I.D. feature NMODIF,97,NX(85)

FILL,91,97 NGEN,2,10,91,97,1,0,-(ZVIT-ZVOT)/2

! Make 100's row for transition FILL,111,141,2,121,10,9,1

/COM,

/COM, FILL IN REST OF NODES IN VESSEL FLANGE FILL,1,5 FILL,81,85 FILL,1,81,7,,,5,1,0.4

/COM,

! FILL IN VESSEL SHELL NODES

/COM, ARRANGE HEAD FLANGE SURFACE NODES CSYS,20 NGEN,2,40,161,169,1,0,RLTH N,201,HFIR,RLTH FILL, 201,203

! COPY LOWER MATING SURF. TO UPPER FLANGE

! HEAD FLANGE INNER SURFACE NGEN,2,10,201,209,1,0,ZHFRI-RLTH

! COPY UP THROUGH UPPER FLANGE NGEN,6,10,211,219,1,0,((ZTHF-ZHFRI)/5)! COPY FIVE ROWS UP THROUGH UPPER FLANGE FILL,221,226,,,,5,10

! ALIGN 220'S ROW

/COM,

/COM, MOVE HEAD SHELL IR NODES CSYS,23 NMODIF, 231, HSIR

  • REPEAT,4,10 FILL,231,234,,,,4,10

/COM,

/COM, DEFINE NODES IN FREE HEAD CSYS,23 N,361,HSIR,90 N,364,HSIR+HSTH,90 N,271,HSIR,AHT N,274,HSIR+HSTH,AHT FILL,271,361,8,,,,,2.5 FILL,274,364,8,,,,,2.5 FILL,251,254,,,,12,10

/COM,

/COM, SWEEP OUT AROUND 360 DEGREES CSYS,21 NGEN,NT+1,1000,ALL,,,0,360/NV,O NROTAT,ALL

/COM,

! TOP OF HEAD (INNER SURFACE)

! TOP OF HEAD (OUTER SURFACE)

! LOCATE I.R. AT TOP OF FILLET RADIUS

! LOCATE O.R. AT TOP OF FILLET RADIUS

! FILL IN HEAD INNER RADIUS

! FILL IN HEAD OUTER RADIUS

! FILL IN INTERIOR HEAD NODES

! MAKE FULL SWEEP OF MODEL

! BRING CS'S INTO ACTIVE CS

/COM, ------------------------------------------------------------------

/COM, ELEMENT DEFINITION

/COM, ------------------------------------------------------------------

/COM,

/COM, ---------------

/COM, MAKE SOLID ELEMENTS TYPE,1 MAT,1 REAL,1 EN,1,1,2,12,11,1001,1002,1012,1011 ENGEN,1,4,1,1,1,1

! SWEEP ACROSS BOTTOM ROW ENGEN,10,8,10,1,4,1

! SWEEP UP TO BOTTOM OF FLANGE SHPP,OFF

! TEMPORARILY TURN OFF SHAPE WARNINGS EN,81,81,82,92,91,1081,1082,1092,1091 EN,82,82,93,92,92,1082,1093,1092,1092 EN,83,82,83,94,93,1082,1083,1094,1093 ENGEN,1,2,1,83 EN,85,84,96,95,95,1084,1096,1095,1095 EN,86,84,85,97,96,1084,1085,1097,1096 EN,91,91,92,102,101,1091,1092,1102,1101 ENGEN,1,6,1,91

! make 91 - 96 ENGEN,10,2,10,91,96,1

! make 101 - 106 ENGEN,10,2,10,101

! MAKE 111 ENGEN,1,8,1,111,111,1

! SWEEP RIGHT TO MAKE 112 - 118 ENGEN,10,5,10,111,118

/COM, 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 31 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 EN,201,201,202,212,211,1201,1202,1212,1211

! MAKE 201 ENGEN,1,4,1,201,201,1

! SWEEP RIGHT TO MAKE 202 TO 204 ENGEN,10,2,10,201,201,1

! SWEEP UP TO MAKE 211 ENGEN,1,8,1,211,211,1 I SWEET RIGHT TO MAKE 212 TO 218 ENGEN,10,5,10,211,218,1 I SWEEP UP TO TOP OF FLANGE ENGEN,10,10,10,251,253,1

! SWEEP THROUGH SHELL EN,351,351,1351,1361,361,352,1352,1362,362

! MAKE 351 ENGEN,1,3,1,351,351,1

! FIX UP LAST ROW

/COM,

/COM,

/COM, ASSIGN BOLT HOLE REGION ESEL,S,ELEM,,146,500,10 ESEL,A,ELEM,,147,500,10 EMODIF,ALL,MAT,3 ESEL,ALL ENGEN,1000,NT,1000,ALL

/COM,

/COM,

/COM, MAKE LINE ELEMENTS FOR STUD TYPE,2 REAL,2 EN,501,164,204 TYPE,3 REAL,ll MAT,2 EN,502,147,267,361

/COM,

/COM,

! SELECT INNER SIDE OF BOLT HOLE

! SELECT OUTER SIDE OF BOLT HOLE I ASSIGN BOLT HOLE DIFFERENT MATERIAL

! COPY AROUND CIRCLE

! REACTION FORCE LINK

! STUD

/COM, MAKE LINE ELEMENTS FOR TIE BARS REAL,4 MAT,1 EN,503,146,147,207 EN,S04,147,148,207 EN,505,266,267,207 EN,506,267,268,207 EN,507,162,163,204 EN,508,163,164,204 EN,509,164,165,204 EN,510,202,203,164 EN,511,203,204,164 EN,512,204,205,164 ENGEN,1000,NT,1000,501,S12,1

/COM, I TIE BARS

! REACTION SURFACE

! COPY REST OF WAY THROUGH

/COM, ----------------

/COM, ASSIGN INDIVIDUAL REAL PROPERTIES TO EACH STUD

/COM, STUD REAL IS STUD NO. + 10

  • DO,I,1,NT ESEL,S,ELEM,,I*1000-498 EMODIF,ALL,REAL,I+10

/COM,

/COM, ----------------------------

/COM, DO SOME NODAL CLEANUP NSLE,U NDELE,ALL NSEL,ALL NUMMRG,NODE,0.001

/COM,

/COM,

! DELETE UNUSED NODES

! MERGE OVERLAPPING NODES

/COM, ------------------------------------------------------------------

/COM, APPLY BOUNDARY CONDITIONS

/COM, ------------------------------------------------------------------

/COM, CSYS,21

/COM, ~~~~~~~~-=~~~~~

/COM, COUPLE UPPER AND LOWER FLANGE AT REACTION RADIUS CP,1,UX,164,204 I COUPLE IN X AXIS CPSGEN,NT,1000,1,1,1

! SWEEP UX SET AROUND CIRCLE CP,101,UY,164,204

! COUPLE IN Y AXIS CPSGEN,NT,1000,101,101,1

! SWEEP UY SET AROUND CIRCLE

/COM, APPLY DISPLACEMENT BOUNDARY CONDITIONS NSEL,S,LOC,Z,BOTZ

! SELECT BOTTOM OF MODEL D,ALL,UY

! APPLY ZERO VERT DISP 121 00 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 32 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 D,ALL,UZ NSEL,ALL

! APPLY ZERO VERT DISP ESEL, S, REAL,, 4

! SELECT TIE BAR ELEMENTS

! SELECT TIE BAR NODES NSLE NSEL,U,NODE,,207,99207,1000 NSEL,U,NODE,,361 D,ALL,ROTX,O,O,,,ROTZ ESEL,ALL

! DESELECT CENTER

! DESELECT TOP OF FLANGE

! HOLD ROTATIONS ON TIE BARS NSEL,ALL

/COM,

/COM,

/COM, APPLY PRYING FORCES DUE TO CORE BARREL SPRING AND CORE SUPPORT LOAD

  • IF,Fspr+Fcsl,GT,1.0,THEN
  • DO,I,1,NT F,131+(I-1)*1000,FZ,-(Fspr+Fcsl)/2 F,132+(I-1)*1000,FZ,-(Fspr+Fcsl)/2 F,201+(I-1)*1000,FZ,+Fspr/2 F,202+(I-1)*1000,FZ,+Fspr/2
  • ENDDO
  • ENDIF

/COM,

/COM,

/COM, PUT SPECIAL BOUNDARY CONDITIONS ON VESSEL FOR PARTIAL MODELS

  • IF,NT,LT,NV,THEN
  • IF,ARG1,LT,O.S,THEN

! USE MIRROR SYMMETRY B.C.s

/COM, DELETE EXTRA ELEMENTS AND NODES BEYOND LAST STUD EDELE,(NT-1)*1000+1,(NT-1)*1000+499

/COM, DO SOME NODAL CLEANUP NSLE,U NDELE,ALL NSEL,ALL

/COM, CHANGE REALS ON CUTTING PLANES ESEL,S,ELEM,,501 ESEL,A,ELEM,,501+(NT-1)*1000 EMODIF,ALL,REAL,3 ESEL,S,ELEM,,503,512 ESEL,A,ELEM,,503+(NT-1)*1000,512+(NT-1)*1000 EMODIF,ALL,REAL,S ESEL,ALL NSEL,S,NODE,,1,1000 NSEL,A,NODE,,1+(NT-1)*1000,NT*1000 NSEL,U,NODE,,204,99204,1000 D,ALL,UY NSEL,ALL

  • IF,Fspr+Fcsl,GT,1.0,THEN F,131,FZ,-(Fspr+Fcsl)/4 F,132,FZ,-(Fspr+Fcsl)/4 F,201,FZ,+Fspr/4 F,202,FZ,+Fspr/4 F,131+(NT-1)*1000,FZ,-(Fspr+Fcsl)/4 F,132+(NT-1)*1000,FZ,-(Fspr+Fcsl)/4 F,201+(NT-1)*1000,FZ,+Fspr/4 F,202+(NT-1)*1000,FZ,+Fspr/4
  • ENDIF
  • ELSE

! USE CYCLIC SYMMETRY B.C.s

/COM, GET RID OF EXCESS ELEMENTS EDELE,(NT-1)*1000+1,(NT-1)*1000+350

/COM, SWING LAST PLANE AROUND TO 0 DEGREES NSEL,S,NODE,,NT*1000+1,(NT+1)*1000 CSYS,21 NMODIF,ALL,,0 NSEL,A,NODE,,1,1000 NSEL,U,NODE,,164,204,40 NROTATE,ALL CPINTF,ALL,0.001 NSEL,S,NODE,,NT*1000+1,(NT+1)*1000 NMODIF,ALL,,NT*360/NV NSEL,ALL NROTATE,ALL

/COM, BRING BACK LAST PLANE OF ELS.

ENGEN,(NT-1)*1000,2,(NT-1)*1000,1,350,1

/COM, FIX UP COUPLES ON EDGE PLANES CP,1,,NT*1000+164,NT*1000+204

! COPY AROUND CIRCLE CP,101,,NT*1000+164,NT*1000+204 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 33 of 41 FX 703.657.7301

Dominion fn~ineerin~, Inc.

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 CP,1501,UZ,164,NT*1000+164 CP,1502,UZ,204,NT*1000+204

  • ENDIF
  • ENDIF Revision No.:

/COM, Define a few components for later use

  • USE,CMMAKER,201,500, 'NHEAD', 'EHEAD'
  • USE,CMMAKER,1,200, 'NVESSEL', 'EVESSEL'
  • USE,CMMAKER,221,500,'NHEADR', 'EHEAOR'

/COM, Define pressure surfaces for PSOLV macro NSEL,S,NOOE,,1,99999,10 0

/COM, Select additional nodes which form crevice between flanges out to the

/COM, inner o-ring NSEL,A,NODE,,161,99999,1000 NSEL,A,NODE,,162,99999,1000 NSEL,A,NODE,,163,99999,1000 NSEL,A,NODE,,201,99999,1000 NSEL,A,NODE,,202,99999,1000 NSEL,A,NODE,,203,99999,1000 CM,PSURF,NODE NSEL,ALL SHPP CHECK

  • END

/COM,

/COM, ----------------------------------------------------------------------------------

/COM, END GEOMETRY MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE CMMAKER MACRO

/COM, ----------------------------------------------------------------------------------

/COM,

  • CREATE, CMMAKER NSEL,NONE ESEL,NONE
  • DO,I,O,(NT-1)*1000,1000 NSEL,A,NODE,,ARG1+1,ARG2+1
  • IF,I,EQ,(NT-1)*1000,THEN
  • IF,NT,LT,NV,EXIT
  • ENDIF ESEL,A,ELEM,,ARG1+1,ARG2+1
  • END DO CM,ARG3,NODE CM,ARG4,ELEM NSEL,ALL ESEL,ALL
  • END

/COM,

/COM, ----------------------------------------------------------------------------------

/COM, END CMMAKER MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE GEOMCLUP MACRO

/COM, ----------------------------------------------------------------------------------

/COM,

  • CREATE,GEOMCLUP CPDELE,ALL,ALL CMDELE, NHEAD CMDELE, EHEAD CMDELE,NVESSEL CMDELE,EVESSEL CMDELE, NHEADR CMDELE,EHEADR 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 34

_.:::.....:.__ of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 EDELE,ALL NDELE,ALL

  • END

/COM, Revision No.:

0

/COM, ----------------------------------------------------------------------------------

/COM, END CMMAKER MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE ENDPOST MACRO

/COM, ----------------------------------------------------------------------------------

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM, RLIST columns as follows:

RLIST(J,1)- Flange Displ. last pass RLIST(J,2) = Stud Initial Elongation Real Constant RLIST(J,3) = Stud Final Membrane Stress RLIST(J,4) =Stud Max. Membrane+Bending Stress RLIST(J,5) = Maximum Membrane Stress during any pass RLIST(J,6) = Pass Number at which Max. Membrane Stress Occurs RLIST(J,7) -Angular Rotation of Upper Flange (radians)

RLIST(J,8) =Angular Rotation of Lower Flange (radians)

RLIST(J,9) =Inner 0-ring separation RLIST(J,10) = Force on Contact Link Element RLIST(J,11) =Global X Shear Force on Coupled Set RLIST(J,12) =Global Y Shear Force on Coupled Set RLIST(J,13) = Mu Required to Prevent Flange Mating Surf. Slide RLIST(J,14) - Mu Required to Prevent Flange Stud Washer Slide Cut Plane Stress Intensities:

Line 1-Vessel Far Field Cut Plane (RLIST(J,15) to RLIST(J,19))

RLIST(J,15) -Linearized SI at Inner Surface RLIST(J,16) =Linearized SI at Center of Surface (Membrane SI)

RLIST(J,17)

  • Linearized SI at Outer Surface RLIST(J,18) -Total SI at Inner Surface RLIST(J,19) =Total SI at Outer Surface

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM, Line 2 -Vessel Local Cut Plane - Lower Line 3 - Vessel Local Cut Plane - Middle Line 4 - Vessel Local Cut Plane - Upper Line 5 - Head Local Cut Plane - Lower Line 6 - Head Local Cut Plane - Middle Line 7 - Head Local Cut Plane - Upper Line 8 - Head Far Field Cut Plane (RLIST(J, 20)

(RLIST(J, 25)

(RLIST (J, 30)

(RLIST(J, 35)

(RLI ST (J, 40)

(RLIST(J, 45)

(RLIST(J, 50) to RLIST(J, 24))

to RLIST(J, 29))

to RLIST(J, 34))

to RLIST(J, 39))

to RLIST(J, 44))

to RLIST(J, 49))

to RLIST(J, 54))

/COM,

  • CREATE,ENDPOST

/COM, Finish by loading results in RLIST

  • DO,J,1,NT ENUMB = )*1000-498
  • GET,RLIST(J,3),ELEM,ENUMB,ETAB,MEMBSTRS
  • GET,DUMBOT,ELEM,ENUMB,ETAB,MAXM+BI
  • GET,DUMTOP,ELEM,ENUMB,ETAB,MAXM+BJ RLIST(J,4)
  • DUMBOT > DUMTOP

/COM, RSYS,21 NNUM1 = (J-1)*1000+131 NNUM2 * (J-1)*1000+139 NNUM3 = (J-1)*1000+211 NNUM4 = (J-1)*1000+219 RLIST(J,7) * (UZ(NNUM4)-UZ(NNUM3))/flwdth RLIST(J,B) = (UZ(NNUM2)-UZ(NNUM1))/flwdtv NNUM1 * (J-1)*1000+164 NNUM2 = (J-1)*1000+204

! El.

! El.

! El.

! El.

no. of subject element membrane stress membrane+bend stress (I) membrane+bend stress (J)

! Node 131

! Node 139

! Node 211

! Node 219

! Upper Flange Rotation

! Lower Flange Rotation (radians)

(radians)

RLIST(J,9) = UZ(NNUM2)-UZ(NNUM1)+iormo*(RLIST(J,8)-RLIST(J,7))

/COM, ENUMB * (J-1)*1000+501

  • GET,RLIST(J,10),ELEM,ENUMB,ETAB,FORCE CMSEL,S,EHEAD NSEL,S,NODE,,(J-1)*1000+204 12100 Sunrise Valley Drive, Suite 220

! El. no. 501

! El. Force Reston, VA 20191 PH 703.657.7300 Page 35

_....::..;::....__ of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 FSUM ESEL,ALL NSEL,ALL Revision No.:

0

  • GET,RLIST(J,11),FSUM,,ITEM,FX

! Global X-Shear Force

  • GET,RLIST(J,12),FSUM,,ITEM,FZ

! Global Z-Shear Force

! RLIST(J,13) is resultant shear divided by link membrane force

  • IF,RLIST(J,10),LT,-1.0,THEN RLIST(J,13) = -SQRT(RLIST(J,11)**2+RLIST(J,12)**2)/RLIST(J,10)
  • ELSE RLIST(J,13) = -1
  • ENDIF

! Trap divide by zero SLIPCNST = 2*Is/(Ds*SWRC*As)

  • IF,RLIST(J,3),GT,1.0,THEN

! Constants in washer slip calc RLIST(J,14)

  • SLIPCNST*(RLIST(J,4)-RLIST(J,3))/RLIST(J,3)
  • ELSE RLIST(J,14) = -1
  • ENDIF

! Trap divide by zero

/COM,

/COM, Cut Lines:

  • USE,READSI,11,15,21,15,J
  • USE,READSI,61,65,21,20,J
  • USE,READSI,71,75,21,25,J
  • USE,READSI,81,85,21,30,J
  • USE,READSI,261,264,24,35,J
  • USE,READSI,271,274,24,40,J
  • USE,READSI,281,284,24,45,J
  • USE,READSI,351,354,24,50,J
  • ENDDO
  • END

! Cut

! Cut

! Cut

! Cut

! Cut

! Cut

! Cut

! Cut 1: Nodes 11 to 15 in CSYS 21 2: Nodes 61 to 65 in CSYS 21 3: Nodes 71 to 75 in CSYS 21 4: Nodes 81 to 85 in CSYS 21 5: Nodes 261 to 261 in CSYS 24 6: Nodes 271 to 274 in CSYS 24 7: Nodes 281 to 284 in CSYS 24 8: Nodes 351 to 354 in CSYS 24

/COM, ----------------------------------------------------------------------------------

/COM, END ENDPOST MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE PRINTENS MACRO

/COM, -------------------*--------------------------------------------------------------

/COM,

/COM,

/COM,

/COM,

/COM,

/COM,

/COM, PRINTENS arguments as follows:

ARG1 z PSAVE Text ARG2 z RSAVE Text ARG3 = Loop Ending No.

ARG4-Free Text Field (e.g., 'Existing')

ARG5 = Sequence Print Flag (1 - Print Sequence)

/COM,

  • CREATE,PRINTENS
  • DO,K,1,ARG3
  • VWRITE,K

('-----',/,'Tensioning Sequence Iteration ',F2.0)

  • VWRITE, ARG4

('-----',/,A,' Procedure Results-')

  • VWRITE (2/, 'Stud Stress Summary',/)
  • VSCFUN,MAXCOL1,MAX, %ARG2%(1, 3,K)
  • VSCFUN,MINCOL1,MIN, %ARG2%(1, 3,K)
  • VSCFUN,AVECOL1,MEAN,%ARG2%(1, 3,K)
  • VSCFUN,MAXCOL2,MAX, %ARG2%(1, 4,K)
  • VSCFUN,MINCOL2,MIN, %ARG2%(1, 4,K)
  • VSCFUN,AVECOL2,MEAN,%ARG2%(1, 4,K)
  • VSCFUN,MAXCOL3,MAX, %ARG2%(1, 5,K)
  • VSCFUN,MINCOL3,MIN, %ARG2%(1, 5,K)
  • VSCFUN,AVECOL3,MEAN,%ARG2%(1, 5,K)
  • VSCFUN,MAXCOL4,MAX, %ARG2%(1,14,K)
  • VSCFUN,MINCOL4,MIN, %ARG2%(1,14,K)
  • VSCFUN,AVECOL4,MEAN,%ARG2%(1,14,K)

/COM,

/COM, MEMBRANE STRESS MEMB+BEND STRESS MAX. MEM.

STRESS REQUIRED WASHER MU 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 36

-~'---- of 41 FX 703.657.7301

Dominion fn~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

  • VWRITE, 'MAXIMUM',MAXCOL1,MAXCOL2,MAXCOL3,MAXCOL4 (A7,3X,3(F9.0,3X),3X,F7.4)
  • VWRITE, 'MINIMUM',MINCOL1,MINCOL2,MINCOL3,MINCOL4 (A7,3X,3(F9.0,3X),3X,F7.4)
  • VWRITE, 'AVERAGE',AVECOL1,AVECOL2,AVECOL3,AVECOL4 (A7,3X,3(F9.0,3X),3X,F7.4)
  • VWRITE (2/, 'Head and Head Flange Cut Planes Stress Summary',/)
  • VSCFUN,AVECOL1,MEAN,%ARG2%(1,51,K)
  • VWRITE, AVECOLl

('General Membrane Stress Intensity

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,36,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,41,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,46,K)

MAXCOL4 = MAXCOLl > MAXCOL2 > MAXCOL3

  • VWRITE,MAXCOL4

('Maximum Local Membrane Stress Intensity

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,35,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,40,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,45,K)

MAXCOL4 z MAXCOLl > MAXCOL2 > MAXCOL3

  • VSCFUN,MINCOL1,MAX,%ARG2%(1,37,K)
  • VSCFUN,MINCOL2,MAX,%ARG2%(1,42,K)
  • VSCFUN,MINCOL3,MAX,%ARG2%(1,47,K)

MINCOL4

  • MINCOLl > MINCOL2 > MINCOL3
  • VWRITE,MAXCOL4 > MINCOL4

('Maximum Local Mem + Bend Stress Intensity

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,38,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,43,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,48,K)

MAXCOL4 s MAXCOLl > MAXCOL2 > MAXCOL3

  • VSCFUN,MINCOLl,MAX,%ARG2%(1,39,K)
  • VSCFUN,MINCOL2,MAX,%ARG2%(1,44,K)
  • VSCFUN,MINCOL3,MAX,%ARG2%(1,49,K)

MINCOL4

  • MINCOLl > MINCOL2 > MINCOL3
  • VWRITE,MAXCOL4 > MINCOL4

', F6.0)

', F6.0)

', F6.0)

('Maximum Local Stress Intensity

',F6.0)

  • VWRITE 0

(2/, 'Vessel and Vessel Flange Cut Planes Stress Summary',/)

  • VSCFUN,AVECOL1,MEAN,%ARG2%(1,16,K)
  • VWRITE,AVECOLl

('General Membrane Stress Intensity

  • VSCFUN,MAXCOLl,MAX,%ARG2%(1,21,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,26,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,31,K)

MAXCOL4 ~ MAXCOLl > MAXCOL2 > MAXCOL3

  • VWRITE, MAXCOL4

('Maximum Local Membrane Stress Intensity

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,20,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,25,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,30,K)

MAXCOL4

  • MAXCOLl > MAXCOL2 > MAXCOL3
  • VSCFUN,MINCOL1,MAX,%ARG2%(1,22,K)
  • VSCFUN,MINCOL2,MAX,%ARG2%(1,27,K)
  • VSCFUN,MINCOL3,MAX,%ARG2%(1,32,K)

MINCOL4 = MINCOLl > MINCOL2 > MINCOL3

  • VWRITE,MAXCOL4 > MINCOL4

('Maximum Local Mem + Bend Stress Intensity

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,23,K)
  • VSCFUN,MAXCOL2,MAX,%ARG2%(1,28,K)
  • VSCFUN,MAXCOL3,MAX,%ARG2%(1,33,K)

MAXCOL4

  • MAXCOLl > MAXCOL2 > MAXCOL3
  • VSCFUN,MINCOL1,MAX,%ARG2%(1,24,K)
  • VSCFUN,MINCOL2,MAX,%ARG2%(1,29,K) 12100 Sunrise Valley Drive, Suite 220

', F6.0)

', F6.0)

', F6.0)

Reston, VA 20191 PH 703.657.7300 Page 37 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0

  • VSCFUN,MINCOL3,MAX,%ARG2%(1,34,K)

MINCOL4 = MINCOLl > MINCOL2 > MINCOL3

  • VWRITE,MAXCOL4 > MINCOL4

('Maximum Local Stress Intensity

',F6.0)

  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,9,K)
  • VWRITE, MAXCOLl (2/, 'Maximum Inner 0-Ring Separation is ',F7.5,' inches.')
  • VSCFUN,MAXCOL1,MAX,%ARG2%(1,13,K)
  • VWRITE, MAXCOLl

('Required Mating Surface Mu to Prevent Slip is ',F7.5,'.')

  • IF,ARGS,EQ,l,THEN
  • VWRITE, ARG4

('-----',/,A,' Procedure - Sequence Listing',/)

/COM, SET NO.

STUD NO.

PRESSURE RETEN. FLAG

  • VWRITE,SEQU,%ARG1%(1,l,K),%ARG1%(1,2,K),%ARG1%(1,4,K)

(4(F9.0,3X))

  • ENOIF
  • VWRITE, ARG4

('-----',/,A,' Procedure Results-Stud Stresses',/)

/COM, MEMBRANE MEMB+BEND MAX. MEM.

ACHIEVED REQUIRED

/COM,STUD #

STRESS STRESS STRESS

@ SET NO.

WASHER MU

  • VWRITE,SEQU,%ARG2%(1,3,K),%ARG2%(1,4,K),%ARG2%(1,5,K),%ARG2%(1,6,K),%ARG2%(1,14,K)

(FS.O,SX,4(F9.0,3X),2X,F7.4)

  • VWRITE,ARG4

('-----',/,A,' Procedure Results-Flange Contact Forces',/)

/COM, GLOBAL GLOBAL REQUIRED

/COM,STUD #

LINK FORCE X SHEAR Z SHEAR FLANGE MU

  • VWRITE,SEQU,%ARG2%(1,10,K),%ARG2%(1,11,K),%ARG2%(1,12,K),%ARG2%(1,13,K)

(F5.0,3X,3(Ell.4,2X),2X,F7.4)

  • VWRITE, ARG4

('-----',/,A,' Procedure Results-Flange Deflections',/)

/COM, UPPER FLANGE LOWER FLANGE 0-RING

/COM,STUD #

ROTATION ROTATION SEPARATION

  • VWRITE,SEQU,%ARG2%(1,7,K),%ARG2%(1,8,K),%ARG2%(1,9,K)

(F5.0,4X,3(E11.4,4X))

CLNO = 0

  • DO,Ll,lS,SO,S CLNO = CLND+l L2
  • Ll+l L3
  • L1+2 L4
  • L1+3 LS = L1+4
  • VWRITE,ARG4,CLNO

('-----',/,A,' Procedure Results-Cut Line ',F2.0,/)

/COM, INNER CENTER OUTER INNER OUTER

/COM,STUD #

LIN. S.I.

LIN. S.I.

LIN. S.I.

TOT. S.I.

TOT. S.I.

  • VWRITE,SEQU,%ARG2%(1,Ll,K),%ARG2%(l,L2,K),%ARG2%(1,L3,K),%ARG2%(1,L4,K),%ARG2%(1,LS,K)

(F5.0,2X,S(F9.0,3X))

  • END DO
  • ENDDO
  • END

/COM, ----------------------------------------------------------------------------------

/COM, END PRINTENS MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM,

/COM,

/COM,

/COM, **********************************************************************************

/COM, **********************************************************************************

/COM, CREATE PRINTOLR MACRO

/COM, ----------------------------------------------------------------------------------

/COM,

/COM,

/COM,

/COM,

/COM, PRINTOLR arguments as follows:

ARGl

  • RSAVE ARRAY TEXT (e.g.,

ARG2 =Case Type (e.g., 'II')

ARG3

  • Starting Case No.

12100 Sunrise Valley Drive, Suite 220

'RSAVE7')

Reston, VA 20191 PH 703.657.7300 Page 38

-=- of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

ARG4 = Ending Case No.

/COM,

/COM,

/COM,

/COM,

/COM,

/COM, ARGS = Starting Vessel Cut Plane No.

ARG6 = Ending Vessel Cut Plane No.

ARG7 = Starting Head Cut Plane No.

ARG8 = Ending Head Cut Plane No.

  • CREATE, PRINTOLR

/COM,

  • IF,ARG2, EQ, 'II', THEN INDADD = 5
  • ELSE INDADD = 0
  • ENDIF 0
  • DO,K,ARG3,ARG4
  • VSCFUN,MAXCOL1,MAX,%ARG1%(1,3,K)
  • VSCFUN,MINCOL1,MIN,%ARG1%(1,3,K)
  • VSCFUN,AVECOL1,MEAN,%ARG1%(1,3,K)
  • VSCFUN,MAXCOL2,MAX,%ARG1%(1,4,K)
  • VSCFUN,MINCOL2,MIN,%ARG1%(1,4,K)
  • VSCFUN,AVECOL2,MEAN,%ARG1%(1,4,K)
  • VSCFUN,MAXCOL3,MAX,%ARG1%(1,5,K)
  • VSCFUN,MINCOL3,MIN,%ARG1%(1,5,K)
  • VSCFUN,AVECOL3,MEAN,%ARG1%(1,5,K)
  • VSCFUN,MAXCOL4,MAX,%ARG1%(1,14,K)
  • VSCFUN,MINCOL4,MIN,%ARG1%(1,14,K)
  • VSCFUN,AVECOL4,MEAN,%ARG1%(1,14,K)

STABLEC2(INDADD+K,2)

  • MAXCOL1/1000 STABLEC2(INDADD+K,1) = MINCOL1/1000 STABLEC2(INDADD+K,3) = MAXCOL2/1000
  • VWRITE, ARG2, K

('-----',/,'Elongation Tolerance Case C',A2, '-',F2.0,/)

  • VWRITE,ARG2

('Level ',A2,' Elongation Tolerance Results-Stud Stresses',/)

/COM, MEMBRANE MEMB+BEND MAX. MEM.

ACHIEVED REQUIRED

/COM,STUD #

STRESS STRESS STRESS

@ SET NO.

WASHER MU

  • VWRITE,SEQU,%ARG1%(1,3,K),%ARG1%(1,4,K),%ARG1%(1,5,K),%ARG1%(1,6,K),%ARG1%(1,14,K)

(FS.O,SX,4(F9.0,3X),2X,F7.4)

  • VWRITE, ARG2

('-----',/,'Level ',A2,' Elongation Tolerance Results-Flange Contact Forces',/)

/COM, GLOBAL GLOBAL REQUIRED

/COM,STUD #

LINK FORCE X SHEAR Z SHEAR FLANGE MU

  • VWRITE,SEQU,%ARG1%(1,10,K),%ARG1%(1,11,K),%ARG1%(1,12,K),%ARG1%(1,13,K)

(F5.0,3X,3(E11.4,2X),2X,F7.4)

  • VWRITE,ARG2

('-----',/,'Level ',A2,' Elongation Tolerance Results-Flange Deflections',/)

/COM, UPPER FLANGE LOWER FLANGE 0-RING

/COM,STUD #

ROTATION ROTATION SEPARATION

  • VWRITE,SEQU,%ARG1%(1,7,K),%ARG1%(1,8,K),%ARG1%(1,9,K)

(F5.0,4X,3(E11.4,4X))

CLNO

  • 0
  • DO,L1,15,50,5 CLNO = CLN0+1 L2 = L1+1 L3 z L1+2 L4 = L1+3 LS
  • L1+4
  • VWRITE,ARG2,CLNO

('-----',/,'Level ',A2,' Elongation Tolerance Results-Cut Line',F2.0,/)

/COM, INNER CENTER OUTER INNER OUTER

/COM,STUD #

LIN. S.I.

LIN. S.I.

LIN. S.I.

TOT. S.I.

TOT. S.I.

  • VWRITE,SEQU,%ARG1%(1,L1,K),%ARG1%(1,L2,K),%ARG1%(1,L3,K),%ARG1%(1,L4,K),%ARG1%(1,LS,K)

(F5.0,2X,S(F9.0,3X))

  • ENDDO
  • DO,L,ARG7,ARG8
  • VSCFUN,TMPMAXSI,MAX,%ARG1%(1,L*5+13,K)

TABLEC2(INDADD+K,4) = TMPMAXSI > TABLEC2(INDADD+K,4)

  • VSCFUN,TMPMAXSI,MAX,%ARG1%(1,L*5+14,K)

TABLEC2(INDADD+K,4) = TMPMAXSI > TABLEC2(INDADD+K,4)

  • ENDDO
  • DO,L,ARGS,ARG6
  • VSCFUN,TMPMAXSI,MAX,%ARG1%(1,L*5+13,K)

TABLEC2(INDADD+K,S)

  • TMPMAXSI > TABLEC2(INDADD+K,S)
  • VSCFUN,TMPMAXSI,MAX,%ARG1%(1,L*5+14,K) 12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 39 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 TABLEC2(INDADD+K,S) m TMPMAXSI > TABLEC2(INDADD+K,S)

  • ENDDO TABLEC2(INDADD+K,4) = TABLEC2(INDADD+K,4)/1000 TABLEC2(INDADD+K,S) = TABLEC2(INDADD+K,S)/1000
  • ENDDO
  • END

/COM, ----------------------------------------------------------------------------------

/COM, END PRINTOLR MACRO

/COM, **********************************************************************************

/COM, **********************************************************************************

12100 Sunrise Valley Drive, Suite 220 Reston, VA 20191 PH 703.657.7300 Page 40 of 41 FX 703.657.7301

Dominion [n~ineerin~, Inc

Title:

Hatch Unit 2 Operation with One Stud Out of Service Evaluation Calculation No.: C-3944-00-01 Revision No.:

0 Page 41 of 41 B

SOFTWARE USAGE RECORDS The following table lists the Software Usage Records for the ANSYS analyses performed in support of this calculation. These records are included on the Data Disk D-3944-00-01 [6] in their native electronic formats. This data disk is retained with the Task 3944 project file and is available for on-site review by Southern Nuclear personnel.

File Name Description HA TCH2.runs Input file which sets run parameters and performs the closure flange evaluation cases.

MACROS.HA TCH2 Input file which sets the finite element model geometry and boundary conditions specific to the Hatch Unit 2 RPV model.

MACROS.DEI Input file which performs stud tensioning and closure flange analyses.

RESUL TS.OUT Formatted output file which contains the stud stress results for the closure flange analysis cases.

HATCH2.out Full output file generated automatically which includes every ANSYS operation performed throughout the analysis.

HATCH2.err Automatically generated error file which includes all warnings generated during the analysis.

Hatch 2 Stud Primary Stress Microsoft Excel spreadsheet used to perform stud primary stress Calc vO.xlsx calculations.