9 to Updated Final Safety Analysis Report, Figure 3.9-1 Through 3.9-2
ML17046A299
Person / Time
Site: Salem  
(DPR-070, DPR-075)
Issue date: 01/30/2017
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17046A230 List: ... further results
References
LR-N17-0034
Download: ML17046A299 (3)


Text

THIS FIGL!,fi!E HAS B~EN DELETED 8VlSlOn

, ~pr1 R

18 A 1 26 2~00 PSEG Nuclear, LLC Solem Nuclear Generotin8 Station SEISMIC DYNAMIC U DEL SALEM NUCLEAR GENERATING STATION Updated FSM Figure 3.9-1

<D 2000 PstG rltle<r, LLC. All Ri ts Res~rved.

I PUBLIC SERVICE ELECTRIC AND GAS COMPANY SALEM NUCLEAR GENERATING STATION REVISION 6 FEBRUARY 15, 1987 Vibration Check* Out Functional Test Inspection Points Updated FSAR

  • Sheet 1 of 2 Figure3.9-2

FEATURES TO BE EXAMINED I

THERMOCOUPLE CONOUIT CLAMPS INSIDE THE THERMOC<XJPlE COLUMN.

2 CLAMP ARRAN(.[MENTS AT THE M<XJNTII\\IG BRACKET LOCATIONS.

J PLUG TO CONDUIT WELD AT THE FIVE SUPPORT COLUMNS ADJACENT TO THE THERMOCOUPLE COLUMNS.

4 ACCESS18lE ANGLE CONDUIT CLAMPS INSIDE THE UPPER SUPPORT COLUMNS.

5 ACCESSIBlE WELD JOINTS AT THE THERMOCOUPLE STOP FOR THE SELF INSTRUMENTED COLUMIIS.

G.WELD JOINTS ON ACCESSIBlE SUPPORT COLUMN ANO MIXING DEVICE GUSSETS.

(THERMOCOJPL£ SUPPORT HARDwARE) 7

,.,.~IGIOIT'l' OF EXPOSED PORTION OF THE_§,MOC<XJPLE CONCUIT RUNS. AT ACCESSIBLE LOCATIONS.

IJNSIOE SUPPORT COlUMNS-LOW£R ENOJ a:

8, RIGIDNESS OF TH£ ACCESSIBLE PROTRUDING THERMOCOUPLE TIPS t ~,--------------------------------------------------------~

9 1 THERMOCOUPLE COLUMN AND GUIDE TUBE SCREW LOCKING DEVICES.

i t' I ACCESSISt.£ ~IPPORT COLUI.III MIXING DEVICE.ORIFICE PLATE. AND CORE P\\.ATE I

'IO, INSERT SCREW LOCKING DEVICES.

~

UPPER COOf PlATE INSERTS.

121 Ca.tCUIT COI'.NECTOR FITTINGS AND CROSS RUN CLAMP ARRANGEMENTS.

\\

13! DEEP SEAM WELDS AT THE SKIRT AND AT THE OUTER HOLLOW ROUNDS.

-f--1'4! ACCESSIBlE GUIDE TUBE wf..LOS.

l 151 UPPER BARREL TO FLANGE GIRTH WElD.

1

<n

...J

~

w

.... g.

0:

w

~

r6j UPPER BARREL TO LOWER BARREL GIRTH WELD.

17 LOWER BARREL TO.CORE SUPPORT GIRTH WELD

  • 18~ UP?ER CORE PLATE ALIGNING PIN WELDS ANO BEARING SURFACES.

19 OUTLET NOZZLE INTERFACE SURFACE C()IIOITION.

.20! THERMALSHIHD FLEXURE ARM. ATTACHMENTS TO BARREL. AND wELD TO THE

  • THERMAL SHIELD. DYE PENETRAII4T INSPECT ALL SIX.

21! THERMAL SHIELD INTERFACt:: AT THE HANG OFF PAOS.

~2~ IRRADIATION SPECIMEN BASKET WELDS.

23! SAFFLE ASSEMSI..Y SCREW LOCKING ARRANG.EMENTS AT THE TWO TOP AND THE TWO BOTTOM FORMER ELEVATIONS.

1241 COR£ SUPPORT COLUMN TO LOWER CORE PLATE SCREW LOCKING* DEVICES. (24 RANDOMLY CHOSEN iz5j CORE SUPPORT COLUMN ADJUSTING SLEEVES.

26J ACCESS18LE(2)

INSTRUMENTATION GUIDE COLUMN LOCKING COLLARS NEAREST THE MA'NWAY, 27 LOCKING DEVICES OF THE BOTTOM INSTRUMENTATION GUIDE COWMNS.

128 LOCKING DEVICES OF THE SECONDARY COR£ SUPPORT.

?O ACCESSIBLE LOCKING OE:_VICES OF THE OFF-SET INSTRUMENTATION COLUMN *

..,. QJPPER AND LOWER ENOS)

.30' RADIAL SUPPORT KEY LOCKING ARRANGEMENTS AND SEARING SURFACES.

~I HEAD AND VESSEL ALIGNING PIN SCREW LOCKING DEVICES AND BEARING SURFACES.

132 CONTACT AT INTERFACE OF THE ACCESSISLE INSTRUMENTATION GUIDE COLUMNS.

33 CONTACT AT INTERFACE OF THE ACCESSIBLE CORE SUPPORT COLUMN NUTS.

~~

34 VESSEL CLEVIS LOCKING ARRANGEMENTS AND BEARING SURFACES.

H----------------------------------1 REVISION 6

~~~~v-~

L_N_o_z_zL_E_r_N_TE_R_.F._AC_E_su R_F~

E_C_ON_~_T_I_ON_. ________________________________

~FEBRUARY15,1987 PUBLIC SERVICE ELECTRIC AND GAS COMPANY SALEM NUCLEAR GENERATING STATION Vibration Check-Out Functional Test Inspection Points Updated FSAR

  • Sheet 2 of 2 Figure 3.9-2