ML17039B080
| ML17039B080 | |
| Person / Time | |
|---|---|
| Site: | Diablo Canyon (DPR-080, DPR-082) |
| Issue date: | 02/08/2017 |
| From: | Jeremy Groom NRC/RGN-IV/DRP/RPB-A |
| To: | Halpin E Pacific Gas & Electric Co |
| JEREMY GROOM | |
| References | |
| EA-16-168 IR 2016010 | |
| Download: ML17039B080 (2) | |
See also: IR 05000275/2016010
Text
February 8, 2017
Mr. Edward D. Halpin
Senior Vice President
and Chief Nuclear Officer
Pacific Gas and Electric Company
Diablo Canyon Power Plant
P.O. Box 56, Mail Code 104/6
Avila Beach, CA 93424
SUBJECT:
DIABLO CANYON POWER PLANT - RESPONSE TO NOTICE OF VIOLATION
(NRC INSPECTION REPORT 05000275/2016010 AND 05000323/2016010)
Dear Mr. Halpin:
On December 28, 2016, the U.S. Nuclear Regulatory Commission (NRC) cited Pacific Gas &
Electrics failure to establish written procedures for performing maintenance on safety-related
equipment, which were appropriate to the circumstances, as required by Diablo Canyon
Units 1 and 2, Technical Specification 5.4.1.a, Procedures. The Notice of Violation, enclosed
with Inspection Report 05000275; 05000323/2016010 (ML16363A429), required you to respond
in writing within 30 days. You responded by letter dated January 26, 2017 (ML17026A486).
We have reviewed your response and find that it meets the requirements of 10 CFR 2.201.
We will review your corrective actions during a future inspection.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be
made available electronically for public inspection in the NRC Public Document Room or from
the NRCs Agencywide Documents Access Management System (ADAMS), which is accessible
from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic
Reading Room).
Sincerely,
/RA/
Jeremy R. Groom, Chief
Project Branch A
Division of Reactor Projects
Docket Nos. 50-275 and 50-323
License Nos. DPR-80 and DPR-82
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION IV
1600 E. LAMAR BLVD.
ARLINGTON, TX 76011-4511
SUNSI Review
By: RDA/dll
Yes No
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available
Keyword:
OFFICE
SPE:DRP/A
BC:DRP/A
NAME
RAlexander
JGroom
SIGNATURE
/RA/
/RA/
DATE
02/06/2017
2/8/17