ML16342D530

From kanterella
Jump to navigation Jump to search
Transmits WCAPs Supporting NRCs Review of License Amend Request 96-10,rev of TSs to Support Extended Fuel Cycles to 24 months.WCAP-11082,rev 5,WCAP-11594,rev 2 & WCAP-14646,rev 1 Withheld
Date released: 01/04/2020 Download: ML16342D530


Rev 4 to WCAP-13705, W Setpoint Methodology for Protection Sys Diablo Canyon Units 1 & 2,24 Month Fuel Cycle Evaluation.
ML17083C623
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/31/1997
From: Andre S, Rood M, Scherder W
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17083C623 (118)
WCAP-11595,Rev 2, W Improved Thermal Design Procedure Instrument Uncertainty Methodology Diablo Canyon Units 1 & 2 24 Month Fuel Cycle Evaluation.
ML16343A474
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/31/1997
From: Andre S, Rood M, Trozzo R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML16343A474 (76)
WCAP-14826, Instrumentation Calibr & Drift Evaluation Process for Diablo Canyon Units 1 & 2,24 Month Fuel Cycle Evaluation.
ML16342D535
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/31/1997
From: Trozzo R, Tuley C
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML16342D535 (68)
Requests Proprietary Version of WCAP-14646,rev 1, Instrumentation Calibration & Drift Evaluation for Diablo Canyon Units 1 & 2,24 Month Fuel Cycle Evaluation, Jan 1997 Be Withheld from Public Disclosure Per 10CFR2.790
ML16342D533
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/24/1997
From: Sepp H
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MIRAGLIA F J
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML16342D533 (18)
Requests WCAP-11082,rev 5, Westinghouse Setpoint Methodology for Protection Sys,Diablo Canyon Units 1 & 2,24 Month Fuel Cycle Evaluation, Jan 1996 Be Withheld from Public Disclosure Per 10CFR2.790
ML16342D532
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/24/1997
From: Sepp H
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MIRAGLIA F J
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML16342D532 (18)
Requests That WCAP-11594,rev 2, W Improved Thermal Design Procedure Instrument Uncertainty Methodology,Diablo Canyon Units 1 & 2,24 Month Fuel Cycle Evaluation Be Withheld from Public Disclosure,Per 10CFR2.790
ML16342D531
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/24/1997
From: Sepp H
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MIRAGLIA F J
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML16342D531 (18)
Transmits WCAPs Supporting NRCs Review of License Amend Request 96-10,rev of TSs to Support Extended Fuel Cycles to 24 months.WCAP-11082,rev 5,WCAP-11594,rev 2 & WCAP-14646,rev 1 Withheld
ML16342D529
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 01/31/1997
From: Rueger G
PACIFIC GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML16342D529 (10)