February 10, 1987 Docket Nos.

50-275 and 50-323 LICENSEE:

FACILITY:

SUBJECT:

Pacific Gas and Electric Company (PGIIE)

Diablo Canyon Nuclear Power Plant MEETING ON DECEMBER 10-12, 1986 - SOIL STRUCTURE INTERACTION EFFORT FOR LONG TERM SEISMIC PROGRAM (LTSP)

NRC staff and its consultants met with PGIIE on December 10-12, 1986 to discuss the status of and future plans for the PGImE soil structure interaction (SSI) studies.

The meeting notice and list of meeting attendees are included as Enclosures I and 2, respectively.

The staff's detailed comments on the meeting are included as Enclosure 3.

Comments by the staff's consultants will be provided later.

The agenda and viewgraphs for the meeting had been provided by PGIIE and are included as Enclosure 4.

At the conclusion of the meeting staff requested the license to provide the following information:

(I)

A list of key parameters (e.g.

base

shears, base spectra) for which the deterministic results obtained from the SSI studies will be compared with the design parameters to ascertain overall plant responses.

(2)

The rationale for selecting these parameters and appropriate levels of comparisons (e.g. fifty percentile, eighty-four percentile responses).

(3)

Information about the containment and the internal structure simplified models used in the studies.

(4)

The time-history input used by the licensee.

(5)

Some additional references on spatial-incoherency studies.

The licensee has since provided the staff with the information requested in items 3, 4 and 5 above which is listed in Enclosure 5 (the information is not included in this summary, it has been placed in the NRC and Diablo Canyon Local PDR).

This information will enable the staff to preform independent studies.

~4~~7~

W&o Q 8703020239 870210

~,,

PDR ADOCK 05000275 P

PDRj.

1

<<j1hk h

n nl Ij ii j

-I ~'jl W-hhga-I Wl En 1.,

E.

I fl'

l. <.

ink EWI W-

Based on the presentations by the licensee and the ensueing discussions at the meeting the staff concludes that substantive progress has been made since the initial meeting on the subject in April 1986.

The staff finds that the program for future studies is well thought out.

The interfaces between the various elements of'he LTSP still need clearer definition, but this problem should 1essen as the actual resu1ts from each of the studies become now available Enclosures As stated Hans Sc ierli g, Project Manager Project Directorate 03 Division of PWR Licensing-A cc:

See next page PDP3 HSchi sng

~/fo/87

gs

'J lrpl I

g

,<< ~, ~

'-> r)

<t fp

}

f y y$ h'gz i,ll*

I

<<T 4

II

~08

'V II k

k

'I K~

I P

~

f C)f

."'i s

P~

ie I

t'*

"P r""

I l<

I

, I J

V

Mr. J.

D. Shiffer Pacific Gas and Electric Company Diablo Canyon CC!

Philip A. Crane, Jr.,

Esa.

Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Mr. Malcolm H. Furbush Vice President - General Counsel

. Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Janice E. Yerr, Esq.

California Public Utilities Commission 350 McAllister Street San Francisco, California 94102 Mr. Frederick Eissler, President Scenic Shoreline Preservation Conference, Inc.

46?3 Nore Mesa Drive Santa

Barbara, California 93105 Ms. Elizabeth Apfelherq 1415 Cozadero San Luis Obispo, California 93401 Ms. Sandra A. Silver 660 Granite Creek Road Santa
Cruz, California 95065 Ha'rry M. Willis, Esq.

Seymour A Willis 601 California Street, Suite 2100 San Francisco, Cali fornia 94108 Mr. Richard Hubbard MHP Technical Associates Suite K

1725 Hamilton Avenue San

>ose, California 95125 Arthur C. Gehr, Esa.

Snell 5

Wi lmer 3100 Valley Center

Phoenix, Arizona 85073 NRC Resident Inspector Diablo Canyon Nuclear Power Plant c/o U.S. Nuclear Reoulatory Commissior:

P. 0.

Box 369 Avila Beach, California 93424 Ms.

Raye Flemino 1920 Mattie Road Shell Beach, California 93440 Joel

Reynolds, Esq.

John R. Phillips, Esq.

Center for Law in the Public Interest 10951 West Pico Boulevard Third Floor Los Angeles, California 90064 Mr. Dick Blankenburg Editor A Co-Puhlisher South County Puhlishina Company P. 0.

Box 460 Arroyo Grande, California 93420 Bruce Norton, Eso.

c/o Phi lip A. Crane, Eso.

Pacific Gas and Electric Companv Post Office Box 7442 San Francisco, California 94120 Mr.

W.

C. Gangloff Westinghouse Electric Corporation P. 0.

Box 355 Pittsburgh, Pennsylvania 15230 David F. Fleischaker, Esa.

P. 0.

Box 1178 Oklahoma City, Oklahoma 73101 Managing Editor San Luis Obispo County Telegram Tribune 1321 Johnson Avenue P. 0.

Box 112 San Luis Obispo, California 0340~

~

)

Paci~ic Gas A Electric Company Diablo Canvon CC:

Dr.

R.

B. Ferguson Siera Club - Santa Lucia Chapte~

Rncky Canyon Star Route Creston, California 93432 Mr. Leland M. Gusta<son, Manager Federal Relations Pacific Gas Il, Electric Company 1726 M Street, N.W.

Suite 1100 Washington, DC 20036-4502 Reoional Administrator, Region V

U.S. Nuclear Regulatory Commission 1450 Maria Lane Suite 210 Walnut Creek, California 94596 Michael J.

Strumwasser, Eso.

Special Counsel to the Attorney General State of California 3580 Wilshire Boulevard, Suite 800 Los Angeles, California 90010 Dian M. Grueneich, Esq.

Edwin F. Lowry, Esq.

Grueneich A Lowry 345 Franklin Street San Francisco, California 94102 Ms. Jacquelyn Wheeler 2455 Leona Street San Luis Obispo, California 93400 Lewis Shollenberger, Esq.

US Nuclear Regulatory Commission Region Y

1450 Maria Lane Suite 210 Walnut Creek, California 94596 Mr. Thomas Devine Government Accountability Pro,iect Institute for Policy Studies 1901 Que Street, HW Washington, DC

?0009 Chairman San Luis Obispo County Board of Supervisors Room 220 County Courthouse Annex San Luis Obispo, California 93401 Director Energy Facilities Siting Division Energy Resources Conservation and Development Commission 1516 9th Street Sacramento, California 95814 President California Public Utilities Commission California State Buildino 350 McAllister Street San Francisco, California 94102 Mr. Joseph 0.

Ward, Chief Radiological Health Branch State Department of Health Services 714 P Street, Office Building f8 Sacramento, California 95814 Ms. Nancy Culver 192 Luneta Street San Luis Obispo, California 93401 Ms. Laurie McDermott, Coordinator Consumers Organized for Defense of Environmental Safety 731 Pacific Street, Suite 42 San Luis Obispo, California 93401

t g

V

Pacif'ic Gas and Electric Company Diahlo Canyon CC:

Dr. S. T. Alaermissen L~.S. Geological Survey P. 0.

Rox 25046 Hail Stop 966 Denver Federal Center

Denver, Colorado 80225 Or. Keiiti Aki Department of Geoloaical Sciences University of Southern Califorria Los Angeles, California 90089 Dr. C. J. Costantino 4 Rockingham Road Sprina Valley, New York 1097>

Dr. James Davis State Geologist California Divison of Mines and Geoloav Room 1351 1416 Ninth Street Sacramento, California 95814 Dr. Ral ph J. Archul eta Department o< Geoloaical Sciences University of California Santa Barbara Santa

Barbara, California 93]06 Dr. Steven M. Day S-Cubed P. 0.

Box 1620 La Jolla, California 92038 Mr. Oon Bernreuter Lawrence Livermore Laboratory P. 0.

Box 808 Livermore, Ca 1 iforni a 94550 Dr. George Gazetas 1EC 408.9 Renssalear Polytechnic Jnstitute

Troy, New York 12180-3590 Mr. Donald A. Brand Vice President, Fnaineerinq Pacific Gas and Electric Company 77 Beale Street, Room 2645 San Francis'co, California 94106 Dr. David Perkins U.

S. Geoloaical Survey P.

0.

Box 25046 Mail Stop 966 Denver Federal Center

Denver, Colorado 80225 Dr. Robert D. Brown, Jr.

U.S. Geological Service Building 8, 8977 345 Middlefield Road Menlo Park, California 94025 Dr. Morris Reich Structural Analysis Division Building 129 Brookhaven National Laboratory

Upton, New York llg73 Mr. Lovd S.

Cluff'acific Gas and Electric Companv 77 Beale Street, Room 2661 San Franci sco, Cali fornia 94106 Dr. Jean Savy Mail Stop L-196 Lawrence Livermore Laboratory P. 0.

Box 808 Livermore, California 94550

\\

I J

Paci<ic Gas and Electric Companv Diablo Canyon CC:

Dr. David B.

Slemmons 2995 Golden Valley Road

Reno, Nevada 89506 Or. Andrew S. Veletsos 5>11 Paisley Avenue
Houston, Texas 7>096 Dr. Robert Youngblnod Building 130 Brookhaven National Laboratory
Upton, New York 11973 Pr.

Ken Campbell U.S. Geoloaical Survey P.O.

Box 25046, ~ail Stop 966 Denver Federal Center

Denver, Colorado 80225

Mr. J.

D. Shiffer Pacific Gas and Electric Company Diablo Canyon CC:

Philip A. Crane, Jr.,

Esq.

Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Mr. Malcolm H. Furbush Vice President - General Counsel Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Janice E. Kerr, Esq.

California Public Utilities Commission 350 McAllister Street San Francisco, California 94102 Mr. Frederick Eissler, President Scenic Shoreline Preservation Conference, Inc.

4623 More Mesa Drive Santa

Barbara, California 93105 Ms. Elizabeth Apfelherg 1415 Cozadero San Luis Obispo, California 93401 Ms. Sandra A. Silver 660 Granite Creek Road Santa
Cruz, California 95065 Harry M. Willis, Esq.

Seymour A Willis 601 California Street, Suite 2100 San Francisco, California 94108 Mr. Richard Hubbard MHB Technical Associates Suite K

1725 Hamilton Avenue San lose, California 95125 Arthur C. Gehr, Esq.

Snell 8 Wilmer 3100 Valley Center

Phoenix, Arizona 85073 NRC Resident Inspector Diablo Canyon Nuclear Power Plant c/o U.S. Nuclear Reoulatory Commission P. 0.

Box 369 Avila Beach, California 93424 Ms.

Raye Fleming 1920 Mattie Road Shell Beach, California 93440 Joel

Reynolds, Esq.

John R. Phillips, Esq.

Center for Law in the Public Interest 10951 West Pico Boulevard Third Floor Los Angeles, California 90064.

Mr. Dick Rlankenburg Editor 5 Co-Puhlisher South County Puhlishing Company P. 0.

Rox 460 Arroyo Grande, Cali Fornia 93420 Bruce Norton, Eso.

c/o Phi lip A. Crane, Eso.

Pacific Gas and Electric Company Post Office Box 7442 San Francisco, California 94120 Mr. W. C. Gangloff Westinghouse Electric Corporation P. 0, Box 355 Pittshurah, Pennsylvania 15230 David F. Fleischaker, Esq.

P. 0.

Box 1178 Oklahoma City, Oklahoma 73101 Managing Editor San Luis Obispo County Telegram, Tribune 1321 Johnson Avenue P. 0.

Box 112 San Luis Obispo, California q3406

1 I

Paci~ic Gas 8 Electric Company Diablo Canvon CC:

Dr. R. B. Ferguson Siera Club - Santa Lucia Chapter Rocky Canyon Star Route Creston, California 93432 Mr. Leland M. Gustafson, Manager Federal Relations Pacific Gas A Electric Company 1726 M Street, N.W.

Suite 1100 Washington, DC 20036-4502 Reoional Administrator, Region V

V.S. Nuclear Regulatory Commission 1450 Maria Lane Suite 210 Walnut Creek, California 94596 Michael J.

Strumwasser, Esq.

Special Counsel to the Attorney General State of California 3580 Wilshire Boulevard, Suite 800

, Los Angeles, California 90010 Dian M. Grueneich, Esq.

Edwin F. Lowry, Esq.

Grueneich 5 Lowry 345 Franklin Street San Franc isco, California 94102 Ms. Jacquelyn Wheeler 2455 Leona Street San Luis Obispo, California 93400 Lewis Shollenberger, Esq.

US Nuclear Regulatory Commission Region V

1450 Maria Lane Suite 210 Walnut Creek, California 94596 Mr. Thomas Devine Government Accountability Project Institute for Policy Studies 1901 Que Street, NW Washington, DC 20009 Chairman San Luis Obispo County Board of Supervisors Room 220 County Courthouse Annex San Luis Obispo, California 93~01 Director Eneroy Facilities Sitino Division Energy Resources Conservation and Development Commission 1516 9th Street Sacramento, California 95814 President California Public Utilities Commission California State Building 350 McAllister Street San Francisco, California 94102 Mr. Joseph 0.

Ward, Chief Radiological Health Branch State Department of Health Services 714 P Street, Office Building N Sacramento, California 95814 Ms. Nancy Culver 19? Luneta Street San Luis Obispo, California 93401 Ms. Laurie McDermott, Coordinator Consumers Organized for Defense of Environmental Safety 731 Pacific Street, Suite 42 San Luis Obispo, California 93401

d

Pacific Gas and Electric Company Diablo Canyon CC:

Or.

S. T. Alaermissen U.S. Geological Survev P. 0.

Box 25046 Mail Stop 966 Denver Federal Center

Denver, Colorado 80225 Dr. Keiiti Aki Department of Geological Sciences University of Southern Califorria Los Angeles, California 90089 Dr. C. J. Costantino 4 Rockingham Road Sprino Valley,-

New York 10977 Dr. James Davis State Geologist California Divison of Nines and Geologv Room 1351 1416 Ninth Street Sacramento, California 95814 Dr. Ral ph J. Archul eta Department of Geoloaical Sciences University of California Santa Barbara Santa

Barbara, California 93106 Dr. Steven M. Day S-Cubed P. 0.

Box 1620 La 3olla, California 92038 Yir. Don Bernreuter Lawrence Livermore Laboratory P. 0.

Box 808 Livermore, California 94550 Or.

George Gazetas JEC

<049 Renssalear Polytechnic institute

Troy, New York 12180-3590 Hr. Donald A. Brand Vice President, Fnaineerinq Pacific Gas and Electric Company 77 Beale Street, Rnom 2645 San Francis'co, California 94105 Dr. David Perkins U. S. Geological Survey P. 0.

Box 25046 Fail Stop 966 Denver Federal Center

Denver, Colorado 80225 Dr. Robert D. Brown, Jr.

U.S. Geological Service Building 8, F977 345 Hiddlefield Road Menlo Park, California 94025 Or. Morris Reich Structural Analysis Division Building 129 Brookhaven National Laboratory

Upton, New York 11973 Nr. Loyd S. Cluff Pacific Gas and Electric Company 77 Beale Street, Room 2661 San Francisco, California 94106 Dr. Jean Savy Nail Stop L-196 Lawrence Livermore Laboratory P. 0.

Box 808 Livermore, California 94550

~

a

~

~

~

Pacific Gas and Electric Company Diablo Canyon CC:

Dr. David B.

Slemmons 2995 Golden Valley Road

Reno, Nevada 89506 Dr. Andrew S. Veletsos 5?11 Paisley Avenue
Houston, Texas 7>096 Dr. Robert Youngblnod Building 130 Brookhaven National Laboratory
Upton, New York 11973 Dr.

Ken Campbell U.S. Geoloaical Survey P.O.

Box 25046, ~ail Stop 966 Denver Federal Center Denver, Colorado 80225