Board Notification 83-128:forwards Info Discussing Status of Investigation Into Reported Test Failures of Asco Class 1E Solenoid Valves
ML16340D660
Person / Time
Site: Fermi, Grand Gulf, Diablo Canyon, Callaway, Waterford, San Onofre, 05000000, Crane
Issue date: 08/31/1983
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Gilinsky V, Palladino N, Roberts T
NRC, NRC COMMISSION (OCM)
Shared Package
ML16340D661 List:
References
TASK-AS, TASK-BN83-128 BN-83-128, NUDOCS 8308040050
Download: ML16340D660 (70)


Text

Docket Nos. 50-289, 275/323, 341, 382, 483, 362, 416 MEMORANDUM FOR:

Chairman Pall adino

,Commissioner Gilinsky Commissioner Roberts Commissioner Asselstine Commissioner Bernthal FROM:

r

SUBJECT:

Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation DRAFT TEST REPORT ON QUALIFICATION TEST PROGRAM OF CLASS lE SOLENOID VALVES (BOARD NOTIFICATION 83>>128)

In accordance with the NRC procedures for Board Notification the following information is being transmitted directly to the Commission.

The appropriate Boards and parties are being notified by copy of this memorandum.

This notification may relate to the following cases which are before the Commission:

TIII-1, Diablo Canyon 1 and 2, Fermi 2, Waterford 3, Callaway 1,, Grand Gulf 1, and San Onofre 3.

Darrell G. Eisenhut, Director

.Division of Licensing Office of Nuclear Reactor Regulation

Enclosure:

As stated This attached information discusses the status of thd staff's investigation into the reported test failures of ASCO Class lE solenoid valves.

These valves are used in most nuclear power plants.

The staff will report the resolution of this matter in a future board notification.

g iggna1 81gneGBV'Darrell G. Eisenhut cc:

See next page DIST:

ADL Reading 50-289, 275/323,

341, 486, 445/446,
244, 433/434,
322, 358,
382, 483,
362, 416, 537, 454/455, 247/286, 329/330, 440/441, 312, 382, 289 OFF)<<)

DL:ADL:TA SBlack:pob SURNAME$..8~/P~

DATE P

~ ~

~

~

f

k'" 783-'DI Piir'pT'e"'-

8/+83

. DIR

'"'en u't'83 NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECOR COPY USGPO: 1981~~960

~

~

V

cc:

EDO OPE OGC SECY ASLB For Clinch River 50-537 (Miller, Hand, Linenberger)

Byron 50-454, 455 (Smith, Callihan, Cole)

Callaway 50-483, 486 (Gleason, Bright, Kline)

Comanche Peak 50-445, 446 (Block, Jordan, McCollom)

Diablo Canyon 50-275, 323 (Wolf, Bright, Kline)

Ginna 50-244 (Grossman,

Cole, Luebke)

Indian Point 50-247, 286 (Gleason,

Paris, Shon)

Midland 50-329, 330 (Bechhoefer,

Cowan, Harbour )

Perry 50-440, 441 (Bloch, Bright, Kline)

Seabrook 50-433, 434 (Hoyt, Harbour, Luebke)

Shoreham 50-322 (Brenner, Carpenter, Morris)

Zimmer 50-358

( Frye, Hooper, Livingston)

ASLAB For Callaway 50-483, 486 (Rosenthal,

Edles, Gotchy)

Diablo Canyon 50-275, 323 (Moore, Buck, Johnson)

Rancho Seco 50-312 (Rosenthal, Buck, Kohl)

Waterford 50-382 (Kohl, Johnson, Wilber)

TMI-1 50-289 (Edles, Buck, Gotchy)

I

'I

DISTRIBUTION LIST FOR BOARD NOTIFICATION Hs. Marjorie Aamodt Hr. Norman Aamodt Mr. Vernon Adler Phillip Ahrens, Esq.

Ms. Elizabeth Apfelberg Maurice Axelrad, Esq.

Mr. Robert A. Backus Edward H. Barrett, Esq.

Thomas A. Baxter.,

Exq."-

'-" -.-:" Charles BeCnhoeTer, Esp.'"

Mayer George G. Begany Lynne Bernabei,- Esq.

Ms. Frieda Berryhill Ezra I. Bialik, Esq.

Mr. Samuel J. Birk E. Blake, Esq.

Brent L. Brandenburg, Esq.

Mr. Richard E. Blankenburg Howard L. Blau, Esq.

Doug'las R. Blazey, Esq.

Peter B. Bloch, Esq.

Jeffrey M. Blum, Esq.

Mr. Dan I. Bolef Nr. Donald Bollinger Ns. Louise Bradford Mr. Paul E. Braunlich Ns.

Nora Bredes Lawrence Brenner, Esq.

Nr. Glenn 0. Bnght Hon. Richard L. Brodsky Daniel F. Brown, Esq.

Mr. Earl Brown Herb'ert H. Brown, Esq.

James E. Brunner, Esq.

Or. John H. Buck Carole H. Burstein, Esq.

Mr. Ronald C. Callen Dr. Dixon Callihan Mr. Calvin A. Canney John G. Cardinal, Esq.

A. S. Carstens Mr. Allen R, Carter Doug Cassel, Esq.

Mr. Brian Cassidy Scott Cauger, Esq.

Kenneth M. Chackes, Esq.

Gerald Charnoff, Esq.

Ms.Diane Chavez Hyron M. Cherry, P.C.

Dr. Thomas B. Cochran Hon. Peter Cohalan Hon. Mark Cohen Paul F. Colarulli, Esq.

David E. Cole, Esq.

Dr. Richard F. Cole Mr. John T. Collins Troy B. Conner, Esq.

Nr. Nicholas J. Costello Mr. Gary D. Cotton Dr. Frederick P.

Cowan Philip A. Crane, Jr.,

Esq.

T. J. Creswell Byrori Units 182, Docket Nos: 50-454/455 Callaway Un'it 1, Docket No.

STN 50-'483 Clinch River, Docket No. 50-537 Comanche Peak Units 182, Docket Nos. 50-445/446 Diablo Canyon Units 182, Docket Nos. 50-275/323 Fermi Unit 2, Docket No. 50-341 Ginna Unit 1, Docket No. 50-244 Grand Gulf Units 182, Docket Nos. 50-416/417 Indian Point Units 283, Docket Nos. 50-247/286 Midland Units 182, Docket Nos. 50-329/330 Perry Units 182, Docket Nos. 50-440/441 Rancho

Seco, Docket. No. 50-312 San Onofre Units 283; Docket Nos. 50-361/362 Seabrook Units 182, Docket Nos. 50-443/444 Shoreham Unit 1, Docket No. 50-322 TMI Unit 1, Docket No. 50-289 Waterford Unit 3, Docket No. 50-382 Zimmer Unit 1, Docket No. 50-358 Edward L. Cross, Jr.,

Esq.

Jordan D. Cunningham, Esq.

Hr. Donald Davidoff Hr. Alfred B. Del Bello Andrew B. Dennison, Esq.

Thomas G. Dignan, Jr.,

Esq.

James B. Dougherty, Esq.

Ms. Jane Doughty Mr. David B. Duboff Mr. Jay Dunkleberger George L. Edgar, Esq.

Gary J.

Edles, Esq.

, Eric A. Eisen, Esq.

Mr. Frederick Eissler Mrs. Juanita Ellis Christopher Ellison, Esq.

Donald T. Ezzone, Esq.

Mr. Jonathan D. Feinberg Dr. George A. Ferguson Mr. Steve Ferns Lawrence R. Fisse, Esq.

David S. Fleischaker, Esq.

Hr. Zipporah S. Fleisher Nrs.

Raye Fleming Luke B. Fontana, Esq.

Dr. Harry Foreman Eleanor L. Frucci, Esq.

Mr. John H. Frye, III R.

K.

Gad III, Esq.

Steve J. Gadler, P.E.

Phyllis M. Gallagher, Esq.

Joseptti Gallo',

Esq.

Mr. R. J.

Gary Ms. Sandra Gavutis Arthur C. Gehr, Esq.

Esq.

Mr. Thomas N. 'Gerusky David H. Gi'lmartin, Esq.

Mr. Stewart tI. Glass James P. Gleason, Esq.

Melvin Goldberg, Esq.

Nr. Mare W. Goldsmith Dr. Reginald L. Gotchy Hr. Mark Gottlieb Mr. Gary L. Groesch Herbert Grossman, Esq.

William J. Guste, Jr., Esq.(2)

Dr. Cadet H. Hand, Jr.

Dr. Jerry Harbour Mr. Thomas H. Harris Hr. Robert J. Harrison Mr. Wayne Hearn

1 a

k j

W. Peter. Heile, Esq.

Donald L. Herzberger, ND.

Ms. Susan Hiatt Mr.'s.

Lyn Harris Hicks Mr. Timothy'S.

Hogan, Jr.

Ms. Beverly Hollingworth Ms. Joan Holt Dr; Frank F. Hooper Helen Hoyt, Esq.

Mr Richard B. Hubbard

,'!Mr~.,Henry D. Huki1 1

'Seri." 'Go'@don J.

Humphrey(2)

Mrs,';

E-1-i-zabeth B. Johnson Mrs~. Phillip B. Johnson Mr. R. Tenney Johnson Dr.

W.

Reed Johnson Dr. Walter H. Jordan William S. Jordan, III, Esq.

Craig Kaplan, Esq.

David S.

Kaplan, Esq.

Mr. James R. Kates Frank J. Kelley, Esq.

James L. Kelley, Esq.

Mr. Chauncey Kepford Janice E. Kerr, Esq.

Ms. Judith Kessler Stanley B. Klimberg, Esq.

Dr. Jerry R. Kline Charles R. Kocher, Esq.

Christine N. Kohl, Esq.

William E. Lantrip, Esq.

Stephen B. Latham, Esq.

Alan Latman, Esq.

James A. Laurenson, Esq.

Ms. Jane Lee Mr. William M. Leech, John Levin, Esq.

David R. Lewis, Esq.

Mr. Marvin I. Lewis Ian Douglas Lindsey, Esq.

Mr. Gustave A. Linenberger Dr. Linda W. Little Dr.

M. Stanley Livingston Terry Lodge, Esq.

Nr. Harold Lottman Dr.

Emmeth A. Luebke Mr. Fred Luekey Nr. John E. Maier Charles J. Maikish, Esq.

Peter A. Marquardt, Esq.

Mr. John Marrs Mr. Wendell H. Marshal David.Hartin, Esq.

Michael McBride, Esq.

Mr. Brian McCaffrey Charles E. McClung, Jr.,Esq.

Dr. Kenneth A. McCollom Robert B. McGehee, Esq.

Mr. Patrick J.

McKeon

.Nr.

Edward F.

Meany Hon.

Ruth Nessinger Ms. Joan Miles Gary L. Milhollin, Esq.

Marshall E. Miller, Esq.

Michael I. Miller, Esq.

Pro. William H. Miller John Minock, Esq.

Mr. Bruce Molholt Byron Units 182, Docket Nos. 50-454/455 Callaway Unit 1, Docket No.

STN 50-483 Clinch River, Docket No. 50-537 Comanche Peak Units 182, Docket Nos.

50-445/446 Diablo Canyon Units 182, Docket Nos.

50-275/323 Fermi Unit 2, Docket No. 50-341 Ginna Unit 1, Docket No. 50-244 Grand Gulf Units 182, Docket Nos.

50-416/417 Indian Point Units 283, Docket Nos.

50-247/286 Midland Units 182, Docket Nos. 50-329/330

'erry Units 182, Docket Nos. 50-440/441 Rancho

Seco, Docket No. 50-312 San Onofre Units 283, Docket Nos. 50-361/362 Seabrook Units 182, Docket Nos. 50-443/444 Shoreham Unit 1, Docket* No. 50-322 TMI Unit 1, Docket No. 50-289 Waterford Unit 3, Docket No. 50-382 Zimmer Unit 1, Docket No. 50-358 Thomas S.
Moore, Esq.

William J.

Moran, Esq.

Dr. Peter A. Morris Ns. Pat Morrison Bruce Norton, Esq.

Nr. Andrew P. O'ourke Dr. Oscar H. Paris Narc L. Parris, Esq.

Nr. Spence Perry Ms. Roberta C. Pevear David R. Pigott, Esq.

David H. Pi kus, Esq.

Mr. Robert N. Pinkney Mr. Samuel.

H. Porter Amanda Potterfield, Esq.

Charles N. Pratt, Esq.

David J. Preister, Esq.

Sen.

Robert L. Preston Nr. Paul Rau James S.

Reed, Esq.

Mr. John G.

Reed Ms. Marjorie Reilly W. Taylor Reveley III, Esq.

Joel R. Reynolds, Esq.

Nicholas S.

Reynolds, Esq.

Ken Robinson, Esq.

Ms. Phyllis Rodriguez Andrew S. Roffe, Esq.

Warren B. Rosenbaum, Esq.

Alan S. Rosenthal, Esq.

Nr. Charles A. Scheiner Dr. David Schink Mr. James, 0. Schuyler Renee

Schwartz, Esq.

Cherif Sedky, Esq.

Ralph Shapiro, Esq.

Mr. Steven C. Sholly Mr. Frederick n). Shon Jo Ann Shotwell, Esq.

Ns. Barbara Shull Jay Silberg, Esq.

Nr. Gor'don Silver Ns. Mary Sinclair Lanny Alan Sinkin Mr. Michael L. Slade Ivan W. Smith, Esq.

Mr. Jeff Smith Nr. C.

W. Smyth Ms. Barbara Stami ris Mayor Howard Steffen Mr. Bob Stein Malcolm Stevenson, Esq.

Michael J.

Strumwasser, Esq.

f

Byron Units 1&2, Docket'Nk. 50-454/455 Call'away Unit 1, Docket No.

STN 50-483 Clinch River, Docket No. 50-537 Comanche Peak Units 1&2, Docket Nos. 50-445/446 Diablo Canyon Units 1&2, Docket Nos. 50-275/323 Fermi Unit 2, Docket No. 50-341 Ginna Unit 1, Docket No. 50-244 Grand Gulf Units 1&2, Docket Nos. 50-416/417 Indian Point Units 2&3, Docket Nos. 50-247/286 Midland Units 1&2,.Docket Nos. 50-329/330 Perry Units 1&2, Docket Nos. 50-440/441 Rancho

Seco, Docket No. 50-312 San Onofre Units 2&3, Docket Nos. 50-361/362 Seabrook Units 1&2, Docket Nos. 50-443/444 Shoreham Unit 1, Docket No. 50-322 TMI Unit 1, Docket No. 50-289 Waterford Unit 3, Docket No. 50-382 Zimmer Unit 1, Docket No. 50-358 Lucinda Low Swartz, Esq.

Hr. Robert G. Taylor David.C. Thomas, Esq.

George F. Trowbridge, Esq.

.Dr. Mauray Tye

'Paul C. Valentine, Esq.

".Ms. Anne Verge Harry Voigt, Esq.

.'Dr. Bruce von Zellen

'Mr. Robert F. Warnick-

.'Alan R. Watts, Esq.

.Deborah

Webb, Esq.

~Ellya R ~iss, Esq..

R'ichavd J.;%teuton, Esq.
-Howard A. Wilber, Esq.

"Frederick C. Wil.liams, Es'q.

Harry H. Willis, Esq.

Daniel D. Wilt, Esq.

John F. Wolf, Esq.

Sheldon J. Wolfe, Esq.

John D. Woliver, Esq.

Mr. Robert G. Wright Mississippi Power

& Light Co.

ATTN: Mr. J.

P.

McGaughy, Jr.

New York State Attorney General's Office, Consumer

Frauds, Energy Utility Division Project Management Corp.,

Oak Ridge, TN Region III, USNRC Rochester Committee for Scientific Information Town Manager's Office

Amexburg, HA Town of North Hampton, NH Atomic Safety and Licensing Board Panel Atomic Safety and Licensing Appeal Panel Docketing and Service Section Document Management Branch ACRS Members Dr. Robert C. Axtmann Hr. Myer Bender-Dr. Max W. Carbon Mr. Jesse C. Ebersole Mr. Harold Etherington Dr. William Kerr Dr. Harold W. Lewis Dr. J.

Ca~son Hark Mr. Willihm M. Mathis Dr. Dade W. Moeller Dr. David Okrent Dr. Hilton S. Plesset Mr. Jeremiah J.

Ray Dk PauT'.

Shewmon Dr. Chester P. Siess Hr. David A. Ward ANGRY/TMI PIRC Brentwood Board of Selectmen Director, Clinch River Breeder Reactor Plant Project Greater NY Council on Energy c/o Mr. Dean R. Corren Lawson HcGhee Public Library MHB Technical Associates Manager of Power',

TVA

I I

Clinch River cc:

Marshall E. Miller, Esq.,

Chairman Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Gustave A. Linenberger Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. Cadet H.

Hand, Jr., Director Bodega Marine Laboratory University of California P. 0.

Box 247 Bodeaa Bay, California 94923 Counsel for NRC Staff'.

S. Nuclear Regulatory Commission Washington, D.C.

20555 William B. Hubbard, Esq.

Deputy At.orney General State of Tennessee Office of the Attorney General 450 James Robertson Parkway Nashville, TN 37219 William E. Lantrip, Esq.

City Attorney Municipal Building P.O.

Box 1

Oak Ridge, TN 37830 George L. Edgar, Esq.

Morgan, Lewis 5 Bockius 1800 M Street, N.W.

Washington, D.C.

20036 Herbert S.

Sanger, Jr.,

Esq.

General Counsel Tennessee Valley Authority 400 West Summit Hill Drive Knoxville, TN 37902 Scott Stuckey, Chief Docketing and Service Section.

Office of the Secretary U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Raymond L. Copeland Project Management Corp.

P.O.

Box U

Oak Ridge, TN 37830 Barbara A. Finamore S.

Jacob Scherr Dr. Thomas B. Cockran Natural Resources Defense Council, Inc.

1725 I Street, N.W. Suite 600 Washington, D.C.

20006 L. Rib LNR Associates Nuclear Power.Safety Consul tants 8605 Grimsby Court

Potomac, MD 20854 Theodore J. Garrish Leon Silverstrom William Luck U.

S.

Department of Energy 1000 Independence Ave., S.W, Room 6-8-256 Washington, D.

C.

20585

l 1

i Byron M.. Dennis L. Farrar Director of Nuclear Licensin9 Commonweal th Edi son Company Post Office Box 767 Chicago, Il1 inoi s 60690 CC:

Mr. William Kortier Atomic Power Distribution Westinghouse Electric Corporation Post Office Box 355 Pittsburgh, Pennsylvania 15230 Paul M. Murphy, Esq.

isham, Lincoln 6 Beale One First National Plaza 42nd Fl oor Chicago, Il 1 inois 60603 Mrs. Ph'illi p B. Johnson 1 907 Stratford Lane Rockford, Illinois 61107 Ms. Bridget Little Rorem Appl eseed Coordinator 117 North Linden Street Essex, Illinois 60935 Dr. Bruce von Zellen Department of Biological Sciences Northern Illinois University DeKalb, Illinois 61107 Mr. Edward R. Crass Nuclear Sa,eguards E Licensing Division Sargent K Lundy Engineers 55 East Monroe Street Chicago, Illinois 60603 Myron Cherry, Esq.

Cherry L Flynn Suite 3700 Th'ree First National Plaza Chicago, Illinois 60602 Mr. Willi'am Forney U. S. Nuclear Reoulatory Commission Byron/Resident Inspectors Office 4448 German Church Road Byron, Illinois 61010 Ms.

Diane Chavez 326 N. Avon Street Rockford, Illinois 61103 Mrs James G. Keppler U. S. Nuclear Regulatnry Commission Reoion III 799 Roosevelt Poad Glen Ellvn, Illinois 60137 Joseph Gallo, Esq.

Isham, Lincoln a Beale Suite 840 1120 Connecticut

Avenue, N.

M.

washington, D.

C.

20036

~ ~

I Mr.

D.

F. Schnell cc (cont'd):

Cal 1 away Mr. John G.

Reed Route fl Kingdom City, Missouri 65262 Mr.

Can I. Bolef, President Kay Drey, Representative Board of Directors Coalition for the Environment St.

Louis Region 6267 Delmar Boulevard University City, Missouri 63130 Mr. Donald Bollinger, member Yiissourians for Safe Energy 6267 Delmar Boulevard University City, Missouri 63130 Mr.

James G. Keppler U.

S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 t ~ ~

Mr.

D.

F. Schnel 1

Vice President - Nuclear Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Gal 1 away CC:

Hr. Nicholas A. Petrick Executive Director - ShUPPS 5 Choke Cherry Road Rockville, Maryland 20850 Gerald Charnoff, Esq.

Thomas A. Baxter, Esq

~

Shaw, Pittman, Potts E Trowbridge 1800 M Street, N.

W.

Washington, D.

C.

20036 Hr. J.

E. Birk Assistant to the General Counsel Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Hr. John Neisler U.

S. Nuclear Reoulatory Commission Resident Inspectors Office RRr.'1

Steedman, Missouri 65077 Mr. Donald H. Capone, Hanaoer Nuclear Engineering Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Mayor Howard Steffen
Chamois, Missouri 65024 Mr. Fred Luekey Presiding
Judge, Montaamery County Rural Route Rhinel and, Missouri 65069 Professor William H. Hiller Missouri Kansas
Section, American nuclear Society Department of huclear Enaineering 102a Enaineering Building University of Missouri Columbia, Missouri 65211 Hr. Robert G. Wright Assoc.

Judge.

Eastern District County Court, Callaway County,.

Missouri Route r.l Ful ton, Missouri 65251 Kenneth N. Chackes Chackes and Hoare Attorney for Joint Intervenors 314 N. Broadway St. Louis, Missouri 63102 A. Scott Cauger, Esq.

Assistant General Counsel for the Missouri Public Service Comm.

Post Office Box 360 Jefferson City, Missouri 65101 Hs. Barbara Shull Ms. Lenore Loeb League of Women Voters of Missouri 2138 Woodson Road St. Louis, Missouri 63114 Hs. Marjorie Reilly Energy Chairman of the Leaoue of Women Voters of University City, MO 7065 Pershing Avenue University City, Missouri 63130 Hr. Earl Brown School District Superintendent Post Office Box 9

Kinadom City, Missouri 65262 Hr. Samuel J. Birk R.

R.

P:1, Box 243 Harrison, Missouri 65061 Nr. Harold Lottman Presidino

Judge, Dasconade County Route 1

0>>ensville, Missouri 65066 Eric A. Eisen, Esq.

Birch, Horton, Bittner and Moore Suite 1100-1140 Connecticut

Avenue, tl. 1'.

1'ashinaton, D.

C.

20036

l I

Mr.

P.. J.

Gary Executive Vice President and General Manager Texas Utilities Generating Company 2001 Bryan-Tower

Dallas, Texas 75201 Comanche Peak CC:

Nicholas S.

Reynolds, Esq.

Debevoise K Liberman 1200 Seventeenth

Street, N. 1'.

4ashington, D.

C.

20036 Sp neer C. Relyea, fsq.

1'orsham, Forsythe 6 Sampels 2001 Bryan Tower

Dallas, Texas 75201 Mr. Homer C. Schmidt Manaaer - Nuclear Services T xas Utilities Services, Inc.

2001 Bryan Tower

Dallas, Texas 75201 Mr. H.

R.

Rock'i bbs a nd Hill, I nc.

3g3 Seventh Avenue New York, New York 10001 Mr. Robert G. Taylor Resident Inspector/Comanche Peak Nuclear Pow

". Station c/o U. S.

Nuclear Reoulatory Commission P.

0 ~

Box 38 Glen Rose, TeI;as 76043 Mr. John T. Collins U.

S.

NPC, Reoion IV 611 Pyan Plaza Drive Suite 1000 Arlington, Texas 76011 Mr. Larry Alan Sinki n 838 East Magnolia Avenue San Antonio, Texas 78212 Mr. A. T. Parker iles tinahnu s e El ec tri c Corpora tion P. 0.

Box 355 Pittsburgh, Pennsylvania 15230 David J. Preister Assistant Attorney General Environmental Protection Division P. 0.

Box 12548, Capitol Station

'ustin, Texas 78711 Mrs. Juanita Ellis, President Citizens Association for Sound Energy 1426 South Polk

Dallas, Texas 75224

Mr. J. 0. Schuyler, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensinq Pacific Gas and Electric Company 77 Beale Street, Room 1435

'San Francisco, California 94106 Philip A. Crane, Jr.,

Esq.

Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Mr. Malcolm H. Furbush Vice President - General Counsel Paci fic Gas

& Electri c Company Post Office Box 7442 San Francisco, California 94120 Janice E. Kerr, Esq.

California Public Uti 1 ities Co;.mi ssi on 350 HcAl lister Street San Francisco, California 94102 Mr. Frederick Eissler, President Scenic Shoreline Preservation Conference, Inc.

4623 More Mesa Drive Santa Barbara, California 93105 Ms. Elizabeth Apfelberg 1415 Cozadero San Luis'bispo, CA 93401 Mr. Gordon A. Silver tls.

Sandra A. Silver 1760 Alisal Street San Luis Obispo, CA 93401 Harry M. Willis, Esq.

Seymour E Willis 601 California Street, Suite 2100 San Francisco, CA 94108 Mr. Richard Hubbard MHB Technical Associates Suite K

1725 Hamilton Avenue San Jose, CA 96125 Mr. John Marrs, Managing Editor San Luis Obispo County Telegram Tribune 1321 Johnson Avenue P.

0.

Box 112 San Luis Obispo, CA 93406 Diablo Canyon Resident Inspector/Diablo Canyon NPS c/o US Nuclear Regulatory Commission P. 0.

Box 369 Avila Beach, California 93424 Ms.

Raye Fleming 1920 Mattie Road

. Shell Beach, California 93440 Joel Reynol ds, Esq.

John P,. Phillips, Esq.

Center for Law in the Public Interest 10951 liest Pico Boulevard Third Floor Los Angel es, Cal iforni a 90064 Paul C. Valentine, Esq.

321 Lytton Avenue Palo Alto, California 94302-Dr. William E. Cooper Project Manaaer -- 5511 Teledyne Engineering Services 130 Second Avenue Waltham, Massachusetts 02254 Mr. Dick Blankenburg Editor E Co-Publisher South County Publishing Company PE 0.

Box 460 Arroyo Grande, California 93420 t

Norton, Burke. Berry 5 French, P.C.

2002 E.

Osborn Road P.

0.

Box 10569 Phoenix, Arizona C5064 Mr.

W.

C. Gangloff Westinghouse Electric Corporation P.

0.

Box 355 Pittsburg, Pennsylvania 15230 David F.

Flei schaker, Esq.

P.

0.

Box 1178 Oklahoma City, Oklahoma 73101

I

Diablo Canyon Arthur C. Gehr, Esq.

Snell E Wilmer 3100 Yalley Center Phoenix, Arizona 85073 Hr.

Lee f~. Gustafson, Director Federal Agency Relations Pacific Gas 5 Electric Company 1050 17th Street, N.

W.

Suite 1180 Washington, D.

C.

20036 Regional Rdministrator - Region V

US Nuclear Regulatory Commission 1450 Haria Lane Suite 210 Walnut Creek, California 94596 Or. Jose Roesset 3506 Duval Road Austin., Texas 78759 Hichael J.

Strumwasser, Esq.

Special Council to the Attorney General State of California 3580 Wilshire Boulevard, Suite 800 Los Anaeles 90010 Hr. Thomas H. Harris

.San Jose mercury News 750 Ridder Park Drive San Jose, California 95190 Hr. tlark Gottlieb California Energy Conrnissi on llll Howe Avenue, AS 27 Sacramento, California 95825 t'maurice Axelrad, Esq.

Lowenstein,

Newman, Reis 1025 Connecticut
Avenue, Washington, D.

C.

20036 and Axelrad NW l

~

~

1 I

1

Ginna 1

Mr. John E. Maier CC Harry H. Voigt, Esquire

LeBoeuf, Lamb, Leiby and MacRae 1333 New Hampshire
Avenue, N.

M.

Suite 1100 Mashington, D. C.

20036 Nr. Michael Slade 12 Trailwood Circle Rochester, New York 14618 Ezra Bialik Assistant Attorney General'nvironmental Protection Bureau New York State Department of Law 2 Morld Trade Center New York, New York 10047 Resident Inspector R.

E. Ginna Plant c/o U. S.

NRC 1503 Lake Road

Ontario, New York 14519 Stanley B. Klimberg, Esquire General Counsel New York State Energy Office Agency Building 2 Empire State Plaza
Albany, New York 12223 Dr.

Emmeth A. Luebke Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Comoission Mashington, D. C.

20555 Dr. Richard F. Cole.

Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Coamission Mashington, D. C.

20555 Dr. Thomas E. Murley, Regional Administrator Nuclear Regulatory Coomission, Region I 631 Park Avenue

'ing of Prussia, P nnsylvania 19406 U. S. Environmental Protection Agency Region II Office ATTN:

Regional Radiation Representative 26 Federal Plaza New York, New York 10007 Herbert Grossman, Esq.,

Chairman Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington,.D.

C.

20555 Supervisor of the Town of Ontari o 107 Ridge Road Mest

Ontario, New York 14519 Jay Dunkleberger New York State Energy.Office Agency Building 2 Empire State Plaza
Albany, New York 12223

, Mr. John D. O'oole Cons6lidated Edison Company of New York, Inc.

Indian Point 2

'c:

Mayor, Village of Buchanan 236 Tate Avenue

Buchanan, New York 10511 Joseph D. Block, Esquire Executive Vice President Administrative Consolidated.Edison Company of New York, Inc.'

Irving Place New York, New York 10003 Robert L. Sorino Nuclear Licensing Engineer Consolidated Edison Conpany of New York, Inc.

4 Irving Place New York, New York 10003 Ms. Ellyn gneiss

Sheldon, Harmon a'nd gneiss 1725 I Street, N.l'., Suite 506 Washington, D.

C.

20006 I,

Senior Resident Inspector U.

S. Nuclear Regulatory Commission P.O.

Box 38

Buchanan, New York 10511 Carl R. D'Alvia, Esquire Attorney for the Village of
Buchanan, New York 3g5 South Riverside Avenue Croton-on-Hudson, New York 10520 Regional Radiation Representatives EPA Reoion II 26 Fedl;ral Plaza New York, New York 10007 Director, Technical Development Programs State o

New York Energoy Office Aoency Bui i di no 2

Empire S=ate Plaza

Albany, New York 12223 Dr. Lawrence P.. (}uarles Apartment 51 Kendal at Longwood Vennett Square, Pennsylvania'g348 Thomas J. Farrelly, Esqui re Law Department Consolidated Edison Company of New York, Inc.

4 Irvino Place New York, New York 10003 Brent L. Brandenburg Assistant General

Counsel, Consolidated Edison Company of New York, Inc.

4 Irving Place 1822 Hew York, Hew York 10003 Regional Administrator - Reaion I

U.

S; Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania

'19406

Nr.. John D. O'oole Consolidated Edison Company of New York, Inc.

Indian Point 2

cc:

Nr. Charles H. Jackson Vice President, Nuclear Power Consolidated Edison Company of New York, Inc.

Broadway and Bleakley Avenues

Buchanan, New York 10511 Nr. N. Blast Director, Regulatory Affairs Consolidated Edison Company of New York, Inc.

Broadway'nd Bleakley Avenues

Buchanan, Hew York 10511 Hr. Frank Natra Resident Construction Manager Consolidated Edison Company of New York, Inc.

Broadway and Bleakley Avenues

Buchanan, New York 10511 Ezra I. Bialik Assi stant Attorney General Eqvironmental Protection Bureau Nhw York State Department of Law 2 Mori d Trade Center New York, New York 10047

1

Mr. J.

P.

Bayne

'ower Authority of the State of Hew York Indian Point 3

cc:

Mr. John C.

Brons

~ indian Point 3 Nuclear Power Plant P.O.

Box 215

Buchanan, New York 10511 Mr. Charles M. Pratt Assistant General Counsel Power Authority of the State of New York'0 Columbus Ci rcle New York, Hew York 10019 Ms. El lyn Wei ss
Sheldon, Harmon and Weiss 1725 I Stree+,

N.W., Suite 506 Washington, D.

C.

20006 Honorable George Beqany Mayor, Village of Buchanan 236 Tate Avenue

Buchanan, New York 10511 Mr. Le roy Q. Sincl a ir Power Authority of the State of Hew York

~ '123 Main Street White Plains, New York 10601 Resident inspector Indian Point Nuclear Generating U. S.

Nuclear Regulatory Commission P.O.

Box 66

Buchanan, New York 10511 Dr. Lawrence R. Ouarles Apartment 51

'Kendal at Longwood Kennet. Souare, Pennsylvania 19348 Mr. Georqe M. Wilverdinq, Manaoer Nuclear Safety Evaluation Poqer Authority of the State of Hew York 123 >'iain Street White Plains, New York 10601 Thomas J. Farrelly, Law Department Consolidated Edison New York, Inc.

4 irvino Place New York, New York Esquire Company of, 10003 Mr. A. Klausmann, Vice Pres ident

(}uality Assurance Power Authority of the State o,

New York 10 Columbus Circle New York, New York 10019 Director, Technical Development Programs State of New York Energy Office Aoency Building 2 Empire State Plaza

Albany, New York 12223 Reqional Radiation Representative EPA Region ii 26 Federal Plaza New York, Hew York 10007 Mr. D. Hal ama t}ua 1 ity As sur ance Su p rint end e nt Indi an Point 3 Nuclear Power Plant Post Office Box 215
Buchanan, New York 10511

Mr. J.

P.

Bayne Power tuthority of the State of New York Indian Point 3

CC:

S.

S-1ulla, Vice President Nuclear Support Power Authority of the State of New Ygrk 123 Main Street l'hite Plains, New York 10601 Recional Administrator - Region I

U.

S. Nuclear'Regulatory Commission 631 Park Avenue Ving of Prussia, Pennsylvania 19406 Ezra I. Bialik Assistant Attorney General Environmental Protection Bureau New York State Department of Law 2 World Trade Center New York, New York 10047 P.: Kokolakis, Director Nuclear Licensing.

Power Authority of the S ate of New York 123 Main Street Whitq Plains, New York 10601.

I

I

MIDLAliD (For BHs)

I Mr. J.

W. Cook Vice President Consumers Power Company 1945 West Parnall Road

Jackson, Michigan 49201 Midiand CC.

Stewart H. Freeman Assistant Attorney General State of Michigan Enviornmental Protection Division 720 Law Building Lansing, Michigan 48913 Mr. Paul Rau Midland Daily Hews 124 NcDonald Street Midland, Michigan 48640 Mr. R. B. Borsum Nuclear Power Generation Division Babcock 5 Wilcox 7910 Woodmont Avenue, Suite 220

Bethesda, Naryl and 20814 Mr. Don van Farrowe, Chief Division of Radiological Health Department of Public Health P.O.

Box 33035 Lansing, Michigan 48909 U.S. Nuclear Reaulatory Commission Re~"i-'~nt Inspectors Office Route 7

Midland, Michigan 48640 Mr. Paul A. Perry, Secretary Consumers Power Company 212 W. Michigan Avenue

Jackson, Michigan 49201 Mr. Valt Apley c/o Mr. Nax Clausen Battelle Pacific North West Labs (PNWL)

Battelle Blvd.

SIGMA IV Building Richland, Vashington 99352 Mr. I. Charak, Manager NRC Assistance Project Argonne National Laboratory 9700 South Cass Avenue Argonne, Illinois 60439 James G. Keppler, Regional Administrator U.S. Nuclear Regul atory Commission, Region III 799 Poosevelt Road Gl en Ellyn, Illinoi s 60137 Hr.

Ron Callen Hichioan Public Service Commission 6545 Mercantile Way P.O.

Box 30221 Lansing, Hichiaan 48909 G otechnical Engineers, Inc.

ATTN: Dr. Steven J.

Poulos 1017 Main Street Winchester, Massachusetts 01890 Billie Pirner Garde Di rector, Citizens Cl i ni c for Accountabl e Government Government Accountabi1 i ty Project Institute for Pol i cy Studi es 1901 gue Street, N.W.

Vashington, D.

C.

20009 Commander, Naval Surface Weapons Center ATTN: P.

C.

Huang h'hite Oak Silver Spring, Maryland 20910 Mr. L. J.

Auge, Manager Facility Design Engi neering Energy Technology Engineerin'g'enter P.O.

Box 1449 Canooa Park, California 91304 Nr. Neil Gehri ng U.S.

Corps of Engineers HCEED - T 7th Fl oor 477 Nichioan Avenue Detroit, Michigan 48226

I I

Hr. l'.urray

.-",. Edelman Yice

. resident, Nuclear Group The Cleveland Electric Illuminating Company P.

0.

Box 5000 Cleveland, Ohi o 44101 Perry CC:

Jay Silberg, Esq.

Shaw, Pittman, Potts

& Trowbridge 1800 H Street, N.

W.

'r'ashington, D.

C.

20006 Donald H. Hauser, Esq.

The Cleveland Electric Illuminating Company P.

0.

Box 5000 Cleveland, Ohi o 44101 Resident Inspector'.s Office U.

S.

Nuclear Regul,atory Commission Parmly at Center Road

Perry, Ohio 44081 U.

S.

Nuclear Regulatory Commission Hr. James G. Keppler, Regional Administrator, Region III 799 Roosevelt Road

. Glen Ellyn, Illinois. 60137 Donald T, Ezzone, Esq.

Assistant Prosecuting Attorney 105 Hain Street Lake County Administration Center Painesville, Ohio 44077 Hs, Sue Hiatt OCPE Interim Representative 8275 Hunson

Hentor, Ohio 44060 Terry J.
Lodge, Esq.

HcCormick, Pommeranz 5 Lodge 824 National Bank Building Toledo, Ohio 43604 John G. Cardinal, Esq.

Prosecuting Attorney Ashtabula County Courthouse Jefferson, Ohio 44047

Mr: Robert J. Harrison President and Chief Executive Officer Public Service Company of New Hampshire Post Office Box 330 Manchester, New Hampshire 03105 Sea brook CC:

Thomas

Dignan, Esq.

John A. Ritscher, Esq.

Ropes and Gray 225 Franklin Street

Boston, Massachusetts 02110 Mr. Bruce B. Beckley, Project Manager Public Service Company of New Hampshire Post Office Box 330 Manchester, New Hampshire 03105 Dr. Mauray Tye, President Sun Valley Association 209 Summer.Street Haverhill, Massachusetts 01839

'Robert A. Backus, Esq.

O'Niell, Backus and Spielman 116 Lowell Street Manchester, New Hampshire 03105 Ms. Beverly A. Hollingworth 7

A Street Hampton Beach, New Hampshire 03842 Diane Curran, Esq.

Harmon and Meiss 1725 I Street, N.

W.

Washington, D.

C.

20006 Jo Ann Shotwell, Esq.

Office of the Assistant Attorney General Environmental Protection Division One Ashburton Place

Boston, Mas'sachusetts 02108 D. Pierre G. Cameron, Jr.,

Esq.

General Counsel Public Service Comoany of New Hampshire Post Office Box 330 Manchester, New Hampshire 03105 Regional Administrator Region I U.

S. Nuclear Regulatory Commission 631 Park. Avenue King of Prussia, Pennsylvania 19406 Mr. Calvin A. Canney, City Manager City Hall 126 Daniel Street Portsmouth, New Hampshire 03801 E. Tupper Kinder, Esq.

G.

Dana frisbee, Esq.

Assis ant Attorney General Office of Attorney General 208 State House Annex

Concord, New Hampshire 03301 Resident Inspector Seabrook Nuclear Power Station c/o US Nuclear Regulatory Commission Post Of i ce Box 700
Seabrook, llew Hampshire 03874 Mr. John DeVincentis, Project Manage'.

Yankee Atomi c El ectri c Company 1671 l)orcester Road Framingham, Massachusetts

.'01701 Mr. A.

M. Ebner, Project tlanager United Engineers 5 Constructors 30 South 17th Street Post Office Box 8223 Philadelphia, Pennsylvania 19101 Mr. Philip Ahrens, Esq.

Assis.ant Attorney General State House, Station

-.-".6 Augusta,,'.aine 04333 Mr. Stephen D. Floyd Public Service Company of New Hampshire Post Office Box 330 Manches er, New Hampshire

. 03105 Seacoast Anti-Pollution League

!1s.

Jane Douohty 5 Market Street Portsmouth, New Hampshire 03801 Mr. John B. Tanzer Town of Hamoton, Net.Hampshire 5 Morningside Drive

Hampton, NH 03842 Ms. Letty Hett Town of Brent>>ood RFD Dal ton Road Brentwond, New Hampshire 03833

I I

Seabrook Mr. Edward F. Meany Town of Rye, New Hampshire 155 washington Road

Rye, New Hampshire 03870 Ms. Roberta C. Pevear Town of Hampton Falls, New Hampshire Drinkwater Road Hampton Falls, New Hampshire 03844 Ms.

Sandra Gavutis Town of Kensington, New Hampshire RFD 1

East Kingston, New Hampshire 03827 Ms.

Anne Verge, Chairman Board of Selectmen Town Hall

,(

South

Hampton, New Hampshire 03842 Alfred V. Sargent, Chairman Board of Selectmen Town of Salisbury, Massachusetts 01950 Ms. Diana P. Randall 70 Collins Street
Seabrook, New Hampshire 03874 Senator Gordon J.

Humphrey U.S.

Senate I'ashington, D.

C.

20510

(Attn:

Tom Burack)

Senator Gordon J.

Humphrey 1 Pi.llsbury St.

Concord, NH 03301 (Attn:

Herb Boynton)

Ms. Angie Machiros, Chairman Board of Selectmen for the, Town of Newbury Newbury, Massachusetts 01950 Ms.

Rosemary

Cashman, Chairman Board of Selectmen Town of Amesbury, MA Town Hall Amesbury, Massachusetts 01913 Nicholas D. Lewis, Chairman Energy Facility Site Evaluation Council Mail Stop PY-ll
Olympia, l)A 98504 Honorable Pichard E. Sullivan Mayor, City of Newburyport 0

ice of the Mayor City Hall Newburyport, Massachusetts 01950 Mt.

Donald E. Chick, Town Manager Town of Exeter 10 Front Street

Exeter, New Hampshire 03823

I I

)

Shor'cham Shoreham Mr. M. S. Pollock Vice President - Nuclear Long Island Lighting Company 175 East Old Country Road Hicksville, New York 11801 CC:

Howard L. Blau, Esquire Blau and Cohn, PC.

217 Newbridge Road Hicksville, New York 11801

'Mr. Jay Dunkl eberger New York State Energy Office Agency Building 2 Empire State Plaza A'lbany, New York 12223 Energy Research Group, Inc.

400-1 Totten Pond Road Waltham, Massachusetts 02154 Mr. Jeff Smith Shoreham Nuclear Power Station Post 0ffice Box 618 Wading River, New York 11792 W. Taylor Reveley, III, Esquire.

Hunton h Williams Post Office Box 1535

.Richmond, Virginia 23212 Ralph Shapiro, Esquire Gammer 8 Shapiro 9 East 40th Street New York, New York 10016 Mr. Brian McCaffrey Long Island Lighting Company 175 E. Old Country Road Hicksville, New York 11801 Honorable Peter Cohalan Suffolk County Executive County Executive/Legislative Bldg.

Veteran's Memorial Highway Hauppauge, New York 11788 David Gilmartin, Esquire Suffolk County Attorney County Executive/Legislative Bldg..

Veteran's Memorial Highway Hauppauge, New York 11788 MHB Technical Associates 1723.Hamilton Avenue, Suite K

San Jose, California 95125 Stephen

Latham, Esquire Twomey, Latham 8

Shea Post Office Box 398 33 West Second Street Riverhead, New York 11901 Jonathan D. Feinberg, Esquire New York State Dept. of Public Service Three Empire State Plaza

Albany, New York 12223 Ezra I. Bialik,, Esquire Assistant-Attorney General Environmental Protection Bureau Ma~x~gatRJhp~lleat QjJa~

2 World Trade Center New York, New York 10047 Resident Inspector Shoreham NPS, U.S.

NRC Post Office Box B

Rocky Point, New York 11-778 Herbert H. Brown, Esquire Kirkpatrick, Lockhart, Hill, Christopher 8 Phillips 1900 M Street, N.W.

Washington, D.C.

20036 Lawrence Coe Lanpher, Esquire Kirkpatrick, Lockhart, Hill, Christopher 5 Phillips 1900 M Street, N.W.

Washington, D.C.

20036 Karla J. Letsche, Esquire Kirkpatrick, Lockhart, Hill, Christopher

& Phillips 1900 M Street, N.W.

Washington, D.C.

20036

Shoreham Shoreham James B. Dougherty, Esq.

~ 3045 Porter Street Washington, D. C.

20008 fir. James Rivello Plant Manager Shoreham Nuclear Power Station P. 0. Box 628 Wading River, New York ll792 Lawrence Brenner, Esq Administrative Judge Atomic Safety 8 Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C...20555 Dr. George A. Ferguson "

School of Engineering Howard University 2300 6th Street, NW Washington, D. C.

20059 Dr., Peter A. Yiorris Administrative Judge Atomic Safety

5. Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555

~

~

Mr. J. Williams, Jr.

Senior Vice President Cincinnati Gas and Electric Company Post Office Box 960 Gincinnati, Ohio 45201 Zimmer CC:

Troy B. Conner, Jr.,

Esq.

Connote, Moore 5, Corber 1747 Pennsylvania
Avenue, N. W.

Washington, D. C.

20006.

Nr. William J.

Moran General Counsel Cincinnati Gas and ETectric, Company Post Office Box 960 Cincinnati, Ohio 45201.

Mr. Samuel H. Porter.

Porter,, Wright, Norris K. Arthur 37 West Broad Street

Columbus, Ohio 43215 Mr Gregory C. Ficke Wm.

H. Zimmer Nuclear Power Station P. 0.

Box 2023 U. S. Route 52 Moscow, Ohio 45153 David Martin, Esq.

Office of the Attorney General'09 St. Gl'air Street First Floor Frankfort, Kentucky 40601 Lynn Bernabei, Esq.

Government Accountabi1 ity Project/IPS 1901 g Street, N.

W.

Washington, D. C.

20009 W. Peter Heile, Esq.

Assistant City Solicitor Room 214, City Hall Cine.innati, Ohi o 45220 John D. Woliver, Esq.

Legal'id Security Post Office Box 047 55 Kilgore Street Batavi a, Ohi o 45103 Mr. John E. Dolan Yice. Chairman Engineering and Construction American Electric Power Company, Inc.

180 Broad Street

Columbus, Ohio 43215 Deborah Faber Webb 796T Alexandria Pike Alexandria, Kentucky 41001 Andrew B. Dennison, Esq.

200 Main Street Batavia,'hi o 45103 George E. Pattison, Esq.

Glermont County Prosecuting Attorney 462.'Main Street

Batavia, Ohio 45103 Mr Wa.1dman Christianson Res ident Inspector/Zimmer RFD 1, Post Office Box 2021 U..

S'.

Route 52 Moscow, Ohio 45153 Mr. Johrr Youkilis Office of the Honorable William Gradison United States House of Representatives Washington, D. C.

20515 Timonthy S.

Hogan, Jr.,

Chairman Board of Commissioners 50 Market Street, Clermont County Batavia, Ohio 45103 Lawrence R. Fisse, Esq.

Assistant-Prosecuting Attorney 462 Main Street

Batavia, Ohio 45103 Mr. James G. Keppler U.. S.

NRC, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137'

S e

Zimmer Edward R.. Schwei binz U. S.

NRC, Region III 799 Roosevelt.

Road Glen Ellyn, Illinois 60137 Mr. Steven G. Smith-The Dayton Power and. Light Company P. 0.

Box 1247

Dayton, Ohio 45401 Mr. James P; Fenstermaker Columbus, and Southern Ohio Electric Company 215 North Front Street
Columbus, Ohio 43215'

r l i

Sacramento Municipal Utility District cc w/enclosure(s):

David S. Kaplan, Secretary and

. General Counsel Sacramento Municipal Utility District 6201 S Street P. 0.

Box 15830 Sacramento, California 95813 Sacramento County Board of Supervisors 827 7th Street, Room 424 Sacramento, Ca1ifornia 95814 Mr. John B. Martin, Regional Administrator U.S. Nuclear Regulatory Commission Region V

1450'Maria Lane, Suite 210 Walnut Creek California 94596 Rancho

Seco, Docket No. 50-312 Christopher Ellison, Esq.

Dian Grueuich, Esq.

California Energy Commission 1111 Howe Avenue Sacramento, California 95825 Ms. Eleanor Schwartz California State Office 600 Pennsylvania Avenue, S.E.,

Rm.

201 Washington, O. C.

20003 Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, O. C.

20555 Resident,Inspector/Rancho Seco c/o V. S.

N. R.

C.

14410 Twin Cities Road emerald; CA 95638 Regional Radiation Representative EPA Reaion IX 215 Fremont Street

'an Francisco, California 94111 Mr. Robert. B. Borsum Babcock 8 Wilcox Nuclear Power Generation Division Suite 220, 7910. Woodmont Avenue

Bethesda, Maryland 20814 Thomas Baxter, Esq-.
Shaw, Pittman, Potts 8 Trowbridge 1800 M Street, N.W.

Washington, D. C.

20036 Atomic Safety and Licensing Appeal Board Panel U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Alan S. Rosenthal, Chairman Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Or.

John H. Buck Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Christine N. Kohl Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Comissi on Washington, O.

C.

20555 Helen Hubbard P. 0.

Box 63 Sunol, California 94586 Joseph 0. Ward, Chief Radiological Health Branch State Deoartment of Health Services 714 P Street, Office Building 88 Sacramento, California 95814

WATERFORD Mr. R'. 'S. Leddick Vice President - Nuclear Operations Louisiana Power

& Light Company 142 Delaronde Street New Orleans Louisiana 70174 CC' W. Malcolm Stevenson, Esq.

Monroe & Lemann 1423 Whitney Building New Orleans, Louisiana 70/Q I

Mr. E. Blake Shaw, Pittman, Potts and Trowbridge 1800 M Street, NW

~

~

Washington, DC 20036 Mr. Gary L. Groesch 2257 Bayou Road New Orleans, Louisiana 70119 Regional Adminstrator-Region IY U. S. Nuclear'egulatory Commission 611 Ryan Plaza Drive Sufte 1000 Arlington, Texas 76012 Mr. F. J.

Drummond Project Manager - Nuclear Louisiana.

Power

& Light Company 142 Oelaronde Street New Orleans, Louisiana 70174r Mr. O. B. Lester Production Engineer Louisiana Power

& Light Company 142. Delaronde Street New Orleans, Louisiana 70174 Luke Fontana, Esq.

824 Esplanade Avenue New Orleans, Louisiana 70116 Stephen M

Irving, Esq.

535 North 6th-Street'aton

Rouge, Louisiana 70802 Resident Inspector/Waterford NPS P. 0. Box 822 Killona, Louisiana 70066 Or. D. C. Gibbs Middle South Service, Inc.

P. 0.

Box 61000 New Orleans, Louisiana 70161

I

~

I

GPU Nuclear Corporation 50-289, TMI-1 Mr. R. J. Toole

Manager, TMI-1 GPU Hucl ear Corporation P. 0.

Box 480 t1i ddl etown, Pennsyl vani a 17057 Board,'of Directors P. A. N. E.

P'. 0.

Box 268 Middletown, Pennsyl vani a 1705T

  • Docke'ting and Service. Section U..S; Nuclear Regulatory Commission Washington, D. C.

20555 Chauncey Kepford Judith H. Johnsrud Environmental C'oalition on Nuclear Power 433 Orlando Avenue State College Pennsyl'vania 16801

  • Judge Reginald L.. Got hy

, Atomic Safety 5 Licensing Appeal Board U.S.

Nucl ear Regulatory Commission Washington, DC 2055$

J.

B. Lieberman, Esq.

sherlock, Israel 5 Lieberman Z6 Broadway New Yprk, Hew York 10004 Jordan.D.

Cunningha'm, Esq.

Fox, Farr and. Cunningham Z320 North 2nd Street Harrisburg, Pennsylvania 17110 Ms Louise. Bradford TMIA 1011 Green Street Harrisburg, Pennsylvania 17102 Ms. Marjorie M. Aamodt R

D. f5 Coatesville,;Pennsylvania 19320 Earl B.. Hoffman Dauphin County Commissioner Dauphin County Courthouse Front and. Market Streets Harrisburg,, Pennsylvania 17101 Union of Concerned Scientists, c/o, - Harmon K.'Weiss 1725 I Street,.

H.. W.

Carte-50 Washington, D.

C.

20006 Mr. Steven C;, Sholly Union of Concerned Scientists 1'346 Connecticut Avenue, N.

W.

Dupont Circle Building, Suite 1101

'Washington, D. C.

20036 lr'. Thomas ~.,')urley, Regional U. S. N.

R. C., Region I 631 Park Avenue.

King of Prussia, Pennsylvania, Administr ator 19406.

ANGRY/TMI PIRC 1037 Maclay Street Harrisburg, Pennsylvania 17103

  • Dr. John H. Buck

- Gary J.

Ed1*es; Chairman Atomic Safety Il Licensing Appeal Board U;S. Nuclear Regulatory Commission Washington, DC 20555 John Levin, Esq.

Pennsylvania Public Utilities Coamission, Box 3265 Harrisburg, Pennsylvania 17120 Atomic Safety

5. Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, DC 20555

I

GPU Nuclear Corporation 50-289, 11II-1 Mr. R J. Toole l"na ger Tl'iI-1 GPU Nucl ear Corporation P. 0. Box 480 Hiddletown, Pennsylvania.

1?057 Board o.

Directors P. A. N.

E P

Q. Box 268 Middletown Pennsylvania 17057

"'oocke'tina and Service Section U..S. Nuclear Reaulatory Commission washington, D.

C 20555'hauncey Kepford.

Judith H. Johnsrud Environmental Coalition on Nuclear Power 433 Orlando, Avenue State Col 1eae, Pennsyl vani a; 16801 "Judae Reginald L

Catchy Atomic Sa. ety k L'icensing AppeaT Board.

U.S.

NucTear Reaulatory Commission Washington,,

DC 20555 J

B Lieberman, Esq Berlock, Israel E Lieberman 26 Broadway New York, New York 10004 Jordan D. Cunningham, Esq.

Fox, Farr and Cunninaham 2320 North 2nd Street Harrisburg, Pennsylvania 17110 Ms Louise Bradford THIA 1011 Green Street Harrisburg, P nnsylvania 17102 Ms. Marjorie M

Aamodt R'

".5 Coates vi 1 1 e, Pennsyl vani a 19320 Earl B

Hoffman Dauphin County Co,.i-;ssioner Dauphin County Courthouse Front. and Harket S reets Harrisburg, Pennsyl vani a 17101 Union of Concerned Scientists, c/o, Harmon 8 Weiss 1725 E Street, N. 1!.

Suite. 506.

1'ashington, D.

C; 20QOG Hr Steven C. Sholly Union of Concerned Sci ntists T346 Connecticut

Avenue, N.

1!.

Dupont Circl e Bui 1 dina, Sui te 1 I Ol Washington, D.

C.

20035

1r.

gnomes E..'1url ey, R"aional U. S. ll. R.

C, Region I 631 Park Avenue King of Prussia, Pennsylvania.

ANGRY/THI PIRC 1037. Haclay Street Harrisburg, Pennsylvania 17103 John Levin, Esq.

Pennsylvania Public Utilities Commi ss cion Box 3265 Harrisburg, Pennsylvania 17120 hdmini strator 19406.

- Gary J.

Edl'es, Chairman Atomic Safety K Licensing Appeal Board U.S. Nuclear Regulatorv Commission Washinaton, DC 20555

+ Dr. John H. Buck Atomic Safety E Licensing Appeal Board U.S. Nuclear Reaulatory Commission washington, DC 20555

GPU Nucl ear Corporati or Mr. Thomas M. Gerusky, Director Burea of Radiation Protection Penns:1, aria. Departmen-of Env ironmental Resources P. 0. Box 2063 Harrisburg, Pennsylvania.

17120 2

General Compel Federal Em(agency Management Agency ATM.

Docket Clerk T725 I Street, NW

- Washing on, DC 20472 TMI-1 Karin W. Carter, Esq.

505 Executive House

'P. O..Box 2357-Harrisburg, Pennsylvania 17120 G.

F. Trowbridge, Esq.

Shaw, Pittman Potts K Trowbridge 1800 M Street, N.W.

Washinoton, D. C.

20036 Mr. E.

G. Wallace Licensing Manager GPU Nuclear Corporation 100 Interpace Parkway Parsippany, New Jersey 07054 Dauphin County Office Emergency Preparedness Court House, Room 7 Front 5, Market Streets Harrisburg, Pennsylvania 17101 Mr; Marvin Z. Lewis 6504 Bradford Terrace Phil'adelphia, Pennsylvania 19149 William S. Jordan, III', Esq.

Harmon c" Weiss 1725 I'treet, Hk~, Suite 505 Washington, DC 20006 Ms. Virginia Southard, Chairman Citizens for a Safe Environment 264 Walton Street

Lemoyne, Pennsyl vani a 17043 Ys. Lennie Prough U. S'. N. R.

C. - Tl>I Site P. 0. Box 311 MiddTetown, Pennsylvania 17057 Mr Robert B. Borsum Babcock 5 Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmnt Avenue

Bethesda, Haryland 20814 Mr. David D. Maxwell, Chairman Board o

Supervisors Londonderry Township RFD81 Geyers-Church Road-Middletown, Pennsylvania T705T Regional Radiation Representative EPA Region III Curtis Building (Sixth Floor) 6th and Walnut Streets Philadelphia, Pennsylvania

. 19106 Mr. Richard Conte Senior Resident Inspector (TMI.-1)

U.S.N.R.C..

P. 0.

Box 311 M'iddletown, Pennsylvania 17057 Mr. C.

W-; Smyth Supervisor of Licensing TMZ-1 GPU Nuclear Corporation P. 0.

Box 480 Middletown. Pennsylvania 17057 Governor's Office of State Planning and Development ATTN:

Coordinator, Pennsylvania State Clearinghouse P. 0.

Box 1323 Harrisburg, Pennsylvania 17120

<<<<Q'<<$

'<<$i""g <<<<,J<<<<'Q, <<<<<<

l<<<< f QQPP+Q

'(<<P'~p ( "Q<<(P '<<'<<'

<<(wp <<+pp lh<<<<P)Pg(<<<<.

((<<4@4 6 <<++(<<kg>@g+<<q(<<<<<~tgg~t]<<SP'll<lg(<<MPH<<>g jlq<<'PLCAUPP~<<<<(<<

TMI-1 a~u >!uclear corporation

~\\

W THI-1'heldon J. Wolfe,. rsq-.,

Chairman

. Atomic Safety 8 Licensing Board Washington, O.C.

20555'r.

David L. Hetrick Atomi'c. Safety 5 Licensing, Board Washington,.

D.C 20555.

Dr. J'ames C.

Lamb-, I'IE

'tomic.

Safety 8 Licensing,Board.

Washington; O.C'0555

~

~

Jane Lee'83'alley Road

Etters, Pennsylvania.

17319

~

"<<'ruce Holholt Haverford Co1Tege Haverford, P'ennsylvania, 19041'orman Aamodt R.. 0

=;.'5, Box. 428.

Coatesvil.l e,,P ennsyl'vani a 19320:

~,

~

~

E

0 I

Fermi Mr. Harry Tauber Vice President Engineering L Construction The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 cc Mr. Harry H. Voight,, Esq.

LeBoeuf,'amb, Leiby 8 MacRae 1333 New Hampshire Avenue, N. M.-

Mashington, D. C.

20036 Peter A'. Marquardt, Esq.

Co-Counsel The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 Mr. William J.

Fahrner Project Manager - Fermi 2

The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 Mr Larry E. Schuerman The Detroit Edison-Company 3331 >lest Big Beaver Road Troy, Michigan 48084'ohn Minock Esq.

1500. Buhl Building Detroit, Michigan 48226 Mr. Bruce Little U. S. Nuclear Regulatory Commission Resident Inspector' Office 6450 W. Dixie Highway Newport, Michigan 48166 Dr. Wayne Jens The. Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226'r.

James G. Keppler U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road G'/en-Ellyn, Illinois 60137 Ronald C. Callen Adv. Planning Review Section Michigan Public Service Commission 6545 Mercantile May P. 0. Box 30221 Lansing, Michigan 48909

0 1

I

Grand Gulf Grand Gulf Mr. J. 'P.

McGaughy Vice President, Nuclear Production Mississippi Power 8 Light Company P. 0.

Box 1640,

Jackson, Mississippi 39205 cc.- Robert B. McGehee, Esquire.

Wise, Carter, Child, Steen and Caraway P.

0 Box 651

Jackson, Mississippi 39205 Troy B. Conner, Jr., Esquire-Conner and Wetterhahn 1747 Pennsylvania
Avenue, N.

W.

Washington, D. C., 20006 Dr. D. C. Gibbs, Vice President Middle South Energy, Inc.

225 Baronne Street P

0. Box 6100.

New-Orleans,. Louisiana, 7016T Mr., Larry Dale Mississippi Power 8 Light Company P

0 Box 1640

Jackson, Mississippi 39205 Mr.

R Trickovic, Project. Engineer Grand Gulf Nuclear Station Bechtel Power Corporation Gaithersburg, Maryland 20760 Mr.. Alan G. Wagner Resident Inspector Route 2, Box 150 Port Gibson, Mississippi 39150

Grand Gulf Grand Gulf cc:

(continued)

Presi'dent Claiborne County Board of Supervisors Port Gibson Nississippi 39150 Office of. the. Governor State. of'issi ssi ppi Jackson,, Nississippi 39201 U. S;, Environmental Protection Agency Attn:=

EIS Coordinator Region IV Office.

345 Courtl'and. Street, N.. E'.,

Atlanta,, Georgia. 30309 Dr.. Alton 8 Cobb State Board. of Health P. 0.

Box 1700

Jackson, Mississippi 39205

I g

~

~

~

~

San Onofre Mr. Robert Dietch Vice President Southern California Edison Company 2244 Walnut Grove-Avenue P. 0.

Box 800

Rosemead, California 91770 hlr. James C

Holcombe Vice President Power Supply San Diego Gas 5'lectric Company 101 Etsh:Street Post Office Box-1831 San Diego, California 92'l12.

cc:

Charles R. Kocher, Esq.

James, A; Beoletto, Esq.

Southern California: Edison Company 2244 Walnut Grove Avenue P. 0. Box. 800 Rosemead,.

Cal ifornia 91770 Orrick, Herrington

8. Sutcliffe ATTN.

David R. Pigott Esq 600 Montgomery Street San. Francisco, California.

941'll'r.

George Caravalho City Manager City of San Clemente.

100 Avenido Presidio.

San Clemente,, California.

92672 Alan R. Watts,, Esq Rourke 8 Woodruff Suite 1020 1055 North. Main Street Santa Ana, Cal ifornia 927Q1 Lawrence g:. Garcia, Esq..

Cal ifornia Puhl ic. Utilities Commission 5066 State Building San Francisco, California 941Q2 Mr. V. C. Hall Combustion Engineering, Inc.

1000 Prospect Hill Road Mindsor, Connecticut, Q6Q95 Mr. S. McClusky Bechtel Power Corporation P. 0.

Box 60860, Terminal Annex Los Angeles, California 90060 Mr. Dennis F. Kirsch U.S. Nuclear Regulatory Comm. - Reg.

V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr; C. B. Brinkman Combustion'Engineering, Inc.

7910 Moodmont Avenue

Bethesda, Maryland 20814 Mr. Mark Medford Southern California Edison Company 2244 Walnut, Grove Avenue P.

O'. Box 800

Rosemead, California 91770 M'.. Hennv-Peters San Diego Gas h Electric Company P
0. Box 1831 San; Diego California.

92T12.

Ms Lyn Harris Hicks Advocate for GUARD 3908. Calle Ariana San Clemente, California 92672 Richard J. Mharton, Esq.

University of San Diego School of Law Environmental Law Clinic San Diego, California 92110 Phyl Tir M Gallagher, Esq.

Suite 222 1695 Vest Crescent Avenue Anaheim, California 92701 Mr. A. S. Carstens 207T Caminito Circu'lo Norte Mt La Jolla, California 92037 Charl!es E. McClung, Jr.,

Esq.

Attorney at. Law 24012 Calle de la Plata/Suite 330 Laguna Hills, California 92653 Resident Inspector, San Onofre/NPS c/o U.S. Nuclear Regulatory Commission P. 0.

Box 4329 San Clemente, California 92672 Regional Administrator-Region V/NRC 1450 Maria Lane/Suite 210 Walnut Creek, California 94596

~

+

~