Board Notification 82-124:forwards Rj Mattson 821123 Memo Re Semiscale S-UT-8 Test Results.Phenomena of Core Level Depression & Loop Seal Clearing May Be More Complex than Previously Supposed
ML16340D029
Person / Time
Site: Diablo Canyon, San Onofre, 05000000
Issue date: 12/14/1982
From: Eisenhut D, Eisenhut D
Office of Nuclear Reactor Regulation
To: Ahearne J, Asselstine J, Gilinsky V, Palladino N, Roberts T
NRC COMMISSION (OCM)
References
TASK-AS, TASK-BN82-124 BN-82-124, NUDOCS 8212220482
Download: ML16340D029 (6)


Text

DEC 14 1982 MEMORANDUM FOR:

Chairman Palladino Commissioner Gilinsky Cormissioner Ahearne Commissioner Roberts Commissioner Asselstine gOr <j5 FROM:

SUBJECT:

Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation INFORMATION ITEM - SEMISCALE S-UT-8 TEST RESULTS (Board Notification No.82-124)

Diablo Canyon Nuclear Power Plant, Units 1/2 San Onofre Nuclear Generating Station, Units 2/3 In accordance with present NRC procedures regarding Board Notifications, the enclosed information is being provided for your information as constituting new information relevant and material to safety issues.

This information is generic and may have applicability to all dockets with Westinghouse or Combustion Engineering plants.

The significance of these test results is that the phenomena of core level depression and loop seal clearing may be more complex than had been thought.

Level depression below the elevation of the pump suction piping before loop seal clearing is a new phenomenon that has not been seen previously.

The relevance of this is that the consequences of an SBLOCA may be more severe than had previously been calculated if the codes cannot model this phenomenon.

However, we do not expect the new phenomena will be shown to result in violations of 10 CFR 50.46 limits.

We are presently pursuing the issue generically with INEL, Westinghouse and Combustion Engineering.

We expect to provide you with the resolution of this issue in the near future.

Or1ginal s1gned b7 Darrell G. Eisonhut 8212220482 82i2i4 PDR ADOCK 05000275 P

PDR

Enclosure:

As stated Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation cc:

SECY OGC OPE DFF1cE/Contact

~ ""'"Suzaiiiie" SURNAME). ~ ~ ~ ~ ~ ~xQ. ~I.pg'78 DATEf acR;"'NRR"""

DL:L SBlack:ms

~

~ ~ ~

12/ /9/82 D

~

THi ak

~ ~ ~ ~ ~

12//P82 DG s

hut 12 82

~

~

~

~

NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USOPO: 1981 335.960

'0 t

I

~0

~ ~

- 2 00 DEc a4 I9S2 may be more severe than had previously been calculated if the codes cannot model this phenomenon.

However, we do not expect the new phenomena will be shown to result in violations of 10 CFR 50.46 limits.

We are presently pursuing the issue generically with INEL, Westinghouse and Combustion Engineering.

We expect to provide you with the resolution of this issue in the near future.

Original signedbp.'.

Thomas M. Novaya H Thomas M. Novak, Assistant Director for Licensing Oivision of Licensing Office of Nuclear Reactor Regulation

Enclosure:

As stated cc:

Licensee/Boards Service List OFFICE P SURNAME/

DATE II DL:L SBlack:ms 12/P /82 L:L

~ ~ \\

~ ~ 0 ~

~ ~

~

~ ~ ~

~ ~ 0 ~ ~ ~ 0 ~000 ~ 0 ~ 0 12'/~/82

~

~ 0 ~ 0 ~ 0

~

NRG FORM 318 t10.80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981~33.960

DISTRIBUTION LIST FOR BOARD NOTIFICATION Before the Commission Diablo Canyon Units 182, Docket Nos. 50-275/323 OL San Onofre Units 283, Docket Nos. 50-361/362 Ms. Elizabeth Apfelberg Mr. Richard E. Blankenburg Mr. Glenn 0. Bright Nr. Herbert H. Brown Dr. John H. Buck A. S. Carstens Mr. Gary D. Cotton Philip A. Crane, Jr.,

Esq.

Stephen F. Eilperin, Esq.

Mr. Frederick Eissler David S. Fleischaker, Esq.

Nrs.

Raye Fleming Phyllis M. Gallagher, Esq.

Arthur C. Gehr, Esq.

Mr. Byron S. Georgious Dr. Reginald L. Gotchy Nr. Mark Gottlieb Dr. Cadet H. Hand, Jr.

Nr. Thomas H. Harris Nrs.

Lyn Harris Hicks Mr. Richard B. Hubbard Nrs. Elizabeth B. Johnson

, Dr.

W.

Reed Johnson James L. Kelley, Esq.

Janice E. Kerr, Esq.

Charles R. Kocher, Esq.

Dr. Jerry Kline Mr. John Marrs Charles E. McClung, Jr.,

Esq.

Thomas S. Moore, Esq.

Bruce Norton, Esq.

David R. Pigott, Esq.

Joel R. Reynolds, Esq.

Nr. James

0. Schuyler Nr. Gordon Silver Paul C. Valentine, Esq.

Alan R. Watts, Esq.

Richard J. Wharton, Esq.

Harry M. Willis John F. Wolf, Esq Atomic Safety and Licensing Board Panel Atomic Safety and Licensing Appeal Panel Docketing and Service Section Document Management Branch ACRS Members Dr. Robert C. Axtmann Mr. Myer Bender Dr. Nax W. Carbon Mr. Jesse C. Ebersole Mr. Harold Etherington Dr. William Kerr Dr. Harold W. Lewis Dr. J.

Carson Mark Mr. William N. Mathis Dr. Dade W. Noeller Dr. David Okrent Dr. flilton S. Plesset Mr. Jeremiah J.

Ray Dr. Paul C.

Shewmon Dr. Chester P. Siess Mr. David A. Ward

0 V