NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 1 of 7 Chief Examiner Comment Facility Action/Response Outline Submittal Comments Written Exam Outline Duplicate generic KAs between Tier 3 and other two Tiers: 2.1.7, one on RO and two on SRO; 2.2.37, two on RO exam; 2.1.25, 2.4.9, and 2.4.31, one on RO and one SRO.
LIC: Will rework as requested.
NRC: Resolved by replaced 000057 2.1.7 (question 79[SRO]) with randomly selected 2.2.40, and 00WE11 2.2.37 (question 18[RO]) with randomly selected 2.1.20 to preclude oversampling.
Written Exam Rejected KAs Need more information / justification for rejection of RO K/As 000062 AA2.04 & 005000 2.4.3 and SRO KAs 000001 2.1.25 & 000037 2.4.6.
LIC: Explained justifications provided.
NRC: Resolved-justifications adequate.
JPMs-Admin Verify that JPMs for Equip Control & Rad Control are indeed modified. (None are new.)
LIC: Changed the initial conditions for the required isolation boundaries by having different equipment out-of-service (Equip Control).
NRC: Significant change to JPM-therefore modified.
JPMs-System JPM h is from previous (2014) exam, and was initially submitted as Alternate Path; Administered version is not. Which is this one?
LIC: JPM is not Alternate Path, and is therefore not considered as previous use.
NRC: Concur-acceptable. (Only one previous, JPM g.)
Scenario ES-D-1 Scenario 1, Event 9; Scenario 2, Event 6; Scenario 5, Event 8: All these events involve a failure of the MSLs to auto isolate. Both the first two events involve Main Turbine Fails to Auto Trip. Are they different events?
What makes them different?
LIC: Failures initiated by different causes to require different mitigation actions.
NRC: Sat-does not adversely impact required discriminating events for applicant evaluation.
Scenario ES-D-1s Verify that, as a minimum, Scenarios 1, 4, & 5 are new or significantly modified, so each applicant sees at least one new or modified scenario.
LIC: Scenarios 1 & 2 are new and 1 & 3 require EOP contingency actions so that all crews will be exposed to at least one new scenario. (SRO-I crews see 1 and SRO-U crews see 3. Scenario 5 significantly modified.
NRC: Resolved-requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 2 of 7 Chief Examiner Comment Facility Action/Response Operating Test Submittal Comments RO/SRO Admin JPMs Comments RO Admin 1 NRC 2016-A1a-RO
- 1. Add bullet to task briefing initial conditions stating that NI Channel indications are as indicated on the attached photographs.
- 2. The Critical Standard (CS) for step 4.3.2 should read readings within the ranges specified in the key on page 6.
- 3. Key on page 6 should be changed to include the ranges. For example the detector current N-41A would be 98.5-99 and the normalized value would be.7275-.7312.
- 4. Need to include the card(s) referenced in CS for step 4.3.3.
LIC: Updated cue to use pictures; updated readings to use nearest 1/2 scale; determined High\\Low values for each of the other scales; calculated Max and Min acceptable reading based on High Low readings from the scale.
Removed reference to spreadsheet.
NRC: Resolved-requirements met.
RO Admin 2 NRC 2016-A2-RO No comments LIC: No Comment.
NRC: Requirements met.
RO Admin 3 NRC 2016-A3 No comments LIC: No Comment.
NRC: Different Initial Conditions - SAT.
RO Admin 4 NRC 2016-A4-RO
- 1. Are separate communicators used to contact Michigan State Police and Berrien County Sheriff Departments?
- 2. Classification Time should be (Current Time
- X minutes) where X=the time delay associated with the referencing the procedure, transmitting the order to Unit 2 to complete section 3.3, and direction given to a licensed operator to complete the EMD-32a.
- 3. Typo in JPM OVERVIEW on bottom of page 3; and contact the MSP within 15 minutes.
- 4. Meteorological Data should be provided when requested, not as an initial condition.
LIC: Separate Communicators are utilized.
Removed Critical Step and Time from SM review and moved time to notification of State Police.
NRC: Resolved-requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 3 of 7 Operating Test Submittal Comments RO/SRO Admin JPMs Comments SRO Admin 1 NRC 2016-A1a-SRO No Comments.
LIC: Updated like RO sheet with new readings for detectors and ranges for QPTR and Power Limits.
NRC: Resolved-requirements met.
SRO Admin 2 NRC 2016-A1b-SRO No Comments.
LIC: Updated to highlight when to provide handouts. Moved Critical Tasks from 7, 8, and 10 to page 12 where form is completed. Removed admin limits from cue on sampling and changed to a standard to be completed by candidate - made this step critical.
NRC: Resolved-requirements met.
SRO Admin 3 NRC 2016-A2-SRO No Comments.
LIC: No Comments.
NRC: Different Initial Conditions - SAT.
SRO Admin 4 NRC 2016-A3-SRO No Comments LIC: Changed Cue to review and approve EMD32a if required. Provided incorrect EMD32A for SRO review and correction if initial event correctly classified, otherwise just record the incorrect classification.
NRC: Resolved-requirements met.
SRO Admin 5 NRC 2016-A4-SRO No Comments LIC: No Comments.
NRC: Requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 4 of 7 Chief Examiner Comment Facility Action/Response Operating Test Submittal Comments RO/SRO CR/IP System JPMs Comments SIM JPM a NRC 2016-SIM01 No Comment LIC: Changed Standard to valves open vs 170 gpm on page 5.
NRC: Requirements met.
SIM JPM b NRC 2016-SIM02
- 2. CS for Att. A Step 2.d (page 6 of JPM); is performance of the step considered UNSAT if applicants actions cause excess letdown temperature to momentarily exceed 195°F.
LIC: Added D for direct from bank to ES-301-2 RO and ES-301-2-SRO-I forms.
Removed Critical Step from Attachment A Step 2.d on page 7. Temperature will not be exceeded on U1.
NRC: Resolved-requirements met.
SIM JPM c NRC 2016-SIM03 No Comment LIC: Remove Critical Step from page 9 (18.a RNO), and page 10 (19.c QRV-251).
NRC: Resolved-requirements met.
SIM JPM d NRC 2016-SIM04 No Comments LIC: Removed Critical Action for ARV-13 & 14 on Page 8.
NRC: Resolved-requirements met.
SIM JPM e NRC 2016-SIM05 No Comments LIC: Added Cue on page 4 for local temps.
NRC: Requirements met.
SIM JPM f NRC 2016-SIM06 No Comments LIC: Removed Critical Step from Train A not actuated and removed operator may attempt to manually actuate on page 4 - Setup changed.
NRC: Resolved-requirements met.
SIM JPM g NRC 2016-SIM07 No Comment LIC: Add cue on Page 4 overvoltage alarm is expected.
NRC: Resolved-requirements met.
SIM JPM h NRC 2016-SIM08
- 1. Evaluator NOTE on page 8 associated with step 4.3 needs to be revised to indicate that contingencies are not expected to be used; NOTE seems to be a holdover from faulted version of JPM.
LIC: Changed words on step 4.3 to Contingency Actions are not expected during this JPM. On page 8.
NRC: Resolved-requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 5 of 7 Chief Examiner Comment Facility Action/Response Operating Test Submittal Comments RO/SRO CR/IP System JPMs Comments IP JPM i NRC 2016-INP01
- 1. The copy of the procedure provided to the examinee should be placed-kept to show that steps 1 and 2 of LS-6 are complete.
LIC: Updated Body of JPM page 4 and procedure handout to show first 2 steps completed as per brief.
Moved and updated cue on page 6. Added resistance and PZR level to cue on page 7.
NRC: Resolved-requirements met.
IP JPM j NRC 2016-INP02 No Comment LIC: Added notes to page 4 & 5 that JPM starts on step 13 to align TDAFP.
NRC: Requirements met.
IP JPM k NRC 2016-INP03 No Comments LIC: No Comments.
NRC: Requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 6 of 7 Chief Examiner Comment Facility Action/Response Scenario D-1 Comments Scenario 1 (2016-01)
- 1. Ensure that (N) and (R) events are pre-briefed prior to crew entering simulator such that only a quick focus brief prior to event is required during exam.
- 2. Event 4/5; Items for US state Enters and directs should list the activities that the US is expected to direct.
- 3. Event 5; The second operator (RO/BOP) action item should be split if the diagnosis (RO) is separate from performance of the immediate action(s) (BOP).
LIC: Clarified reason for pumps swap on turnover.
Added North CRAC to Stop and 30 day time clock to event 3. Cleaned up actions on Event 4 to reflect procedural actions; explained RIL and added notes about Turbine hold Page 10; removed SI actuated check and listed action for No SI and transition to H.1 through red path.
NRC: Resolved-requirements met.
Scenario 2 (2016-02)
- 1. Event 1; What is/are the significant verifiable operator action(s) for the RO?
- 2. Event 2; See comment 1 for Scenario 1.
- 3. Event 3; The second operator (RO/BOP) action item should be split if the diagnosis (RO) is separate from performance of the immediate action(s) (BOP).
- 4. Major Transient; Expand details of RO/BOP E-0 immediate actions.
- 5. Major Transient; Expand details of operator actions for E-0, Attachment A (could be separate attachment or section of scenario guide) if significant component failures imposed.
LIC: Event 1 added SM/MTI to actions for relay, added time for TRM -72 hrs. Event 2 removed place in stop since it was previously done. Event 3 Added note about actual failure and step to contact local operator. Event 4 SM/MTI and 6 hr time added to action. Page 7 added alarms to start of event.
NRC: Resolved-requirements met.
Scenario 3 (2016-03)
- 1. Event 2; See comment 1 for Scenario 1.
- 2. Event 3; The second operator (RO/BOP) action item should be split if the diagnosis (RO) is separate from performance of the immediate action(s) (BOP).
- 3. Event 6; Provide an explanation why PORV rad monitors are considered inoperable with the PORV being inoperable.
- 4. Major Transient; Expand details of RO/BOP E-0/
ECA-0.0 immediate actions.
LIC: Event 2 Added Steps for Reactivity change.
Updated turnover to include Startup steps for power change. Event 3 Made Tasks RO (vs. ATC or RO/BOP). Event 4 added mode change note to TS. Event 5 change Manual to Hand; removed Critical Task for TDAFP start and replaced with Seal Return Isolation. Updated Step for Isolating PZR Heaters on page 11 and drops for checking Bus faults.
NRC: Resolved-requirements met.
NRC ILE Outline and Operating Test Submittal Comments 2016 DC Cook Nuclear Plant Units 1 and 2 CE: RD Baker 7 of 7 Chief Examiner Comment Facility Action/Response Scenario D-1 Comments Scenario 4 (2016-04)
- 1. Crews 2 and 4 are both slated to see Scenarios 2 and 4. Both scenarios have VCT level instrument failures (one high, one low). While the response actions are different, the same procedures and TS/TRM sections are exercised; therefore a crew should not be administered both scenarios.
- 2. Similarly, Scenarios 3 and 4 both have failures that cause SG 4 PORV to fail open. Again the operator actions significantly overlap, therefore ensure that a crew is not administered both scenarios.
- 3. Event 1; Ensure that the simulator provides adequate feedback to ensure that the verifiable operator actions can support a licensing decision.
- 4. Event 3; See comment 1 for Scenario 1.
- 5. Event 3; Previous scenarios assign the RO(ATC) the responsibility for turbine manipulation. This scenario assigns the responsibility to either the RO or BOP. Scenarios need to be consistent.
- 6. Major Transient; Expand details of operator actions for E-0, Attachment A (could be separate attachment or section of scenario guide) if significant component failures imposed.
LIC: Swapped Event 2 from scenario 4 with Event 3 on Scenario 5. Swapped New Event 2 and Event 5 on Scenario 4. Corrected East ESW on event 1. Event 2 and Event 5 updated TS description and times. Added SM/MTI to bistable statement for Event 5 and Event 6. Added after SI to header when RHR trips. Changed P.1 entry to will not may.
NRC: Resolved-requirements met.
Scenario 5 (2016-05)
- 1. Event 2; See comment 1 for Scenario 1.
- 2. Items for US that state Enters and directs should list the activities that the US is expected to direct.
- 3. Major Transient; Expand details of operator actions for E-0, Attachment A (could be separate attachment or section of scenario guide) if significant component failures imposed.
LIC: Swapped Event 2 from scenario 4 with Event 3 on Scenario 5. Swapped Events 2 and Event 3.
Added PR Dev alarms to Event 3. Added SM/MTI to bistable statement for Event 2 and Event 6. Added Drop 31 to Event 5. Added Alarm to CTS Pump trip on page 10, removed IMO 204 from CT, and added Spray Add flow to CT#2.
NRC: Resolved-requirements met.