~p,R REog c,~

C~

~o

~O

<<+**"

UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 April 5, 1979 BOARD NOTIFICATION Re:

Cherokee 1-3 Diablo Canyon 1-2 FNP Greene County Jamesport 1-2 Marble Hill 1-2 McGuire 1-2 North Anna 1

Pebble Springs 1-2 Perkins 1-3 Pilgrim 2 Seabrook Shearon Harris 1-4 Sterling St. Lucie 2 Three Mile Island 2

Tyrone Wolf Creek WPPSS 4

Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No Docket No 50-491-2-3 50-275-323 50-437 50-549 50-516-7 50-546-7 50-369-70 50-338-9 50-514-5 50-488-89-90 50-471 50-443-4 50-400-1-2-3 50-485 50-389 50-320 50-484 50-482 50-513 Distribution:

Copies of a "Board Notification" dated April 5, 1979, have been served on the following persons.

Those whose addresses are at the U ~ S ~ Nuclear Regulatory Commission have been served by the NRC internal mail system and others have been served by deposit in the U ~ S

~ Mail ~

One copy has been served on each person even though hi s or her name appears on more than one service list.

In addition to copies served on Atomic Safety and Licensing Board and Atomic Safety and Licensing Appeal Board members identified on the service list, 19 copies of the attachment have been provided to the Atomic Safety and Licensing Board Panel, and 1 copy of the attachment has been provided to the Atomic Safety and Licensing Appeal Board Panel.

>>o5~4o oz8 g

In the Matter of DUKE POWER.COMPANY (Cherokee Nuclear Station, Units 1, 2 and 3)

Docket Nos.

STN 50-491 STN 50-'492 STN 50-493

+Alan S. Rosenthal, Esq.,

Chairman Atomic Safety and Licensing'ppeal Board U.S. Nuclear, Regulatory Commission Washington, D. C. 20555

  • Richard S. Salzman,. Esq.

Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D. C. 20555

  • Dr. John H. Buck Atomic Safety and -Licensing AppealBoard U.S. Nuclear Regulatory Commission Washington, D. C.

20555

  • Elizabeth S.
Bowers, Esq.

Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Comriiission Washington, D. C. 20555 0'r. Donald P.

deSylva Associate Professor of Marine and Atmospheric Science University of Miami Miami, Florida 33149 Dr. Walter H. Jordan 881 W. Outer Drive Oak Ridge, Tennessee 37830 J.

Michael McGarry, lII, Esq.

Debevoise and'iberman 1200 Seventeenth

Street, N.W.

Washington, DC 20036 State of South Carolina c/o Ms. Jacquelyn Dickman Dept. of Health 8 Environmental Control 2600 BulI Street Columbia, South Carolina 29201

\\

Cherokee Nuclear Station William L. Porter, Esq.

Associate General Counsel Duke Power Company 442 South Church Street Charlotte, North Carolina 28242 M. Richbourg

Roberson, Esq.

Assistant Attorney General Office of the Attorney General 2600 Bull Street Columbia South Carolina 29201

  • Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D. C. 20555 "Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D. C. 20555
  • Docket and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D. C. 20555

In -the Matter of

)

)

PACIFIC GAS AND ELECTRIC COMPANY

)

)

(Diablo Canyon Nuclear Power Plant

)

Unit Nos.

1 and 2)

Docket Nos.

50-275 O.L.

50-323 O.L.

Richard S.

Salzman, Esq.,

Chairman

'tomic Safety and Licensing Appeal Board U.

S. Nuclear Regulatory Commission Washington, D. C.

20555 Alan S.

Rosenthal, Esq.

Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Dr.

W.

Reed Johnson Atomic Safety,and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D-. C.

20555

  • Elizabeth S.
Bowers, Esq.

Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Mrs. Elizabeth Apfelberg 1415 Cozadero San Luis Obispo, California 93401

  • Mr. Glenn 0. Bright Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Dr. William E. Martin Senior Ecologist Battelle Memorial Institute

Columbus, Ohio 43201 Philip A. Crane, Jr.,

Esq.

Pacific Gas and Electric Company Room 3127 77 Beale Street San Francisco,. California 94106'r.

Frederick Ei.ssler Scenic Shoreline Preservation Conference, Inc.

4623 More Mesa Drive Santa Barbara, California 93105 Mrs Raye Fleming 1920 Mattie Road Shell Beach, California 93449 Mrs. Sandra A. Silver 5055 Radford Avenue North Hollywood, California 91607 Hr. Gordon Silver 5055 Radford Avenue North Hollywood, California 91607 John R. Phillips, Esq.

Simon Klevansky, Esq.

Margaret Blodgett, Esq.

Center for Law in the Public Interest 10203 Santa Monica Drive Los Angeles, California

.90067 Arthur C. Gehr, Esq.

Snell 5 Wi lmer 3100 Valley Center Phoenix; Arizona 85073 Paul C.

~ Valentine, Esq.

321 Lytton Avenue Palo Alto, California 94302 Yale I. Jones, Esq.

100 Van Ness Avenue 19th Floor San Francisco, California 94102 David F. Fleischaker, Esq.

1025 15th,Street, N.W..

5th Floor Washington, D.

C.

20005

  • Atomic Safety and Licensing Appeal Panel U.

S. Nuclear Regulatory Commission Washington, D. C.

20555

  • Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D. C.

20555

,* Docketing and Service Section Affico nf the Roc'ret~rv U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Richard B. Hubbard HHB Technical Associates 366 California Avenue Palo Alto, California 94306 Janice E. Kerr, Esq.

Lawrence g. Garcia, Esq.

350 HcAllister Street San Francisco, California 94102 Hr..James

0. Schuyler Nuclear Projects Engineer Pacific Gas and Elec'tric Company 77 Beale Street San Francisco, California 94106 Bruce Norton, Esq.,

3216 North 3rd Street.

Suite 202 Phoenix, Arizona 85012 John Harrs Hanaging Editor San Luis Obispo County Telegram-Tribune 1321 Johnson Avenue P..O.

Box 112 San Luis Obispo, California 93406

In the Matter of OFFSHORE POWER SYSTEMS (Floating Nuclear Power Plants)

Docket No.

STN 50-437 Sheldon J

~ Wolfe, Esq.,

Chairman" Atomic Safety and Licensing Board U.S. Nuclear, Regulatory Commission

. Washington, D.C.

20555 Dr. David R. Schink Department of Oceanography Texas A 8 M University College Station, Texas 7784'3 Mr. Lester Kornblith, Jr.*

Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Vincent W. Campbell, Esq.

Vice President and General Counsel Offshore Power Systems P.O.

Box 8000 8000 Arlington Expressway Jacksonville, Florida 32211 Dr. David L. Hetrick Professor of Nuclear Engineerinz The University of Arizona

Tucson, Arizona
85721, Docketing and Service Section*

Office of the Secretary

'.S.

Nuclear Regulatory Commi ssic

'ashington, D.C.-

20555 Richard M. Hluchan, Esq.

Deputy Attorney General State of New Jersey 36 West State Street

Trenton, New Jersey 08625 Anthony Z. Roisman, Esq.

Natural Resources Defense Council 917 15th Street, N.W.

Washington, D.C.

20005 Mary M. Cheh,. Esq.

Suite 1000 600 New Hampshire. Avenue, N.W.

Washington, D.C.

20037 Barton Z. Cowan, Esq.

'Eckert,

Seamans, Cherin 8 Mellot Forty-Second Fl oor 600 Grant Street Pittsburgh, Pennsylvania 15219

Thomas M. Daugherty, Esq.

Offshore Power Systems 8000 Arlington Expressway P.O.

Box 8000 Jacksonville, Florida 32211 Mr. John H. Williamson 211 Forest Drive

Linwood, New Jersey 08221 City of Brigantine Attn:

Mr. George B. Ward Brigantine, New Jersey 08203 Harold P. Green, Esq.

600 New Hampshire

Avenue, N.W.

Washington, D.C.

20037 Carl Yalore, Esq.

535 Tilton Road P.O.

Box 152 Northfield, New Jersey '8225 Dr. Willard W. Rosenberg 8 N.

Rumson Avenue

Margate, New Jersey 08221 Dr. Glenn L. Paulson Assistant Commissioner of the State of New Jersey Department of Environmental Protection Labor 8 Industry Building John Fitch Plaza
Trenton, New Jersey 08625 Samuel J. Chilk, Secretary*

Office of the Secretary of the Commiss'ion U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Harold P. Abrams 9100 Amherst Avenue

Margate, New Jersey 08402 Mr. Mitchell Attalla 4028 Ponce De Leon Avenue Jacksonville, Florida 32217 Keith A. Onsdorff, Esq.

Department of Public Advocate Division of Public Interest Advocate P.O.

Box 141 520 East State Street

Trenton, New Jersey '8625 Atomic Safety and Licensing Board Panel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing Appeal Panel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555

In the Matter of POWER AUTHORITY OF THE STATE OF NEW YORK Docket No. 50-549 (Greene County Nuclear Power Plant))

Andrew C.

Goodhope, Esq.,

Chairman*

Atomic Safety and Licensing Board 3320 Estelle Terrace

Wheaton, Maryland

'20906 Dr. George A. Ferguson Professor of Nuclear Engineering Howard University Washington, D.

C.

20001 Dr. Richard F. Cole*

Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Ms.

Rosemary S: Pooler Executive Director New York State Consumer Protection Board 99 Washington Avenue

Albany, New York 12210 Lewis R. Bennett, Esq.

Assistant General Manager-General Counsel Power Auth'ority of the State of New York-10 Columbus Circle New York, New'ork 10010 Arthur L. Reuter, Esq.

Attorney at Law Sharpe's Landing.

Germantown, New York 12526 Mr; Peter D.

G.

Brown Chairman Mid-Hudson Nuclear Opponents P.O.

Box 666 New Paltz, New York 12561

Citizens to Preserve the Hudson Valley c/o Robert J. Kafin, Esq.

Miller, Mannix, Lemery 8

Yafin, P.C.

11 Chester Street Glenns Falls, New York 12801 i,'.",ncy'Spiegel, Esq.

Staff Counsel, State of New York Public Service C:.mmission Empire State Plaza

Albany, New York 12223 Village of Catskill c/o Daniel K. Lalor, Esq.
Meadow, Ruf ard Lalor, P.C.

75 Water Street G tskill, New York 12414 Algird F. White,'r.,

Esq.

DeGraff, Foy, Conway and Holt-Harris 90 State Street

Albany, New York 12207

'<illiam J. Spampinato, Esq.

Rosenberg 5 Spampinato 443 Warren Street

Hudson, New York

'12534 Mr.

kahn N'.ckol itch Cementon Civic Association 70 Short Street

Cementon, New York 12415

~'frey Cohen, Esq.

lew York State Energy Office Swan Street Building Core 1, Second Floor
Albany, New York 12223 Daniel Riesel, Esq.

Winer, Neuburger 8 Sive 425 Park Avenue New York, New York 10022 Mayor George.A. Turner, Jr.

Village Clerk's Office Petition Street P. 0.

Box 96 Saugerties, New York 12477 Albert K. Butzel, Esq.

Butzel and Kass 45 Rockefeller Plaza Suite 2350 New York, New'ork 10020 Honorable Edward D.

Cohen Presiding Examiner Public Service Commission Empire State Plaza Agency Building

Albany, New York 12223 David H. Engel, Esq.

Assistant Counsel for Energy New York State Department of Environmental Conservation 50 Wolf Road

Albany, New York 12233 Honorable Donald Carson Associate Hearing Examiner Department, of Environmental Conservation

.50 Wolf Road

Albany, New York 12233
  • Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washinaton, D.

C.

20555

  • Atomic Safety and Licensing Appeal Panel U.S.

%clear Regulatory Commission Washington, D. C.

20555

  • Docketing and Service Section Office of the Secretary U.S.

hbclear Regulatory Commission Washington, D. -C.

20555

I I

In the Matter of LONG ISLAND LIGHTIflG COMPANY (Jamesport Nuclear Power Station, Units 1

and 2)

)

)

)

Docket Nos.

50-516 50-517

)

)

A

  • Jerome E. Sharfman, Esq.,

Chairman Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Dr.

W.

Reed Johnson Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Richard S.
Salzman, Esq.

Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Sheldon J. Wolfe, Esq.

Atomic Safety and Licensing Board U.S.

Nuclear Regulatory Commission Washington, D. C.

20555 Mr-. Ralph S.

Decker Route 1, Box 190D Cambridge, Maryland 21613 Dr. E. Leonard Cheatum Route ¹3, Box 350A Watkinsville, Georgia 30677 Edward J. Walsh, Jr.,

Esq.

Long Island Lighting Company 250 Old County Road

Mineola, New York 11501 W. Taylor Reveley, III, Esq.

Hunton 5 Williams P. 0.

Box 1535 Richmond, Virginia 23212 Mr. A.

E. Kintigh Vice President-Generation New Yo'rk State Electric 8

Gas Co.

4500 Vestal Parkway East Binghampton, New York 13902 Environmental Protection and Progress Committee Local 25, I.,B. E.

W.

Box 997 41 Pinelawn Road Melville, New York 11746

Dr. Caryl R. Granttham Co-Chairman, Concerned Citizens of Suffolk County Box 550 Jamesport, New York 11947 Ms. Jean H. Tiedke Box 1103

Southold, New York 11971 Dr. Harris Fischer Suffolk County Department of Environmental Control 1324 Motor Parkway Hauppauge, New York 11787 Irving Like, Esq.

Reilly, Like 5 Schneider 200 West Main Street

Babylon, New York 11702 Mrs. Laetitia deK. Bradley 144 quaker Path
Setauket, New York 11733 Ms. Shirley L. Bachrach Box 1054
Southold, New York 11971 Ms. Adelaide Flatau 30 Dartmouth Road
Shoreham, New York 11786 William C.

Chapek Box 997 melville, New York 11746 Joseph C. Gramer, Esq.

425 Broadhollow Road Melville, New York 11746 Frederick H. Lawrence, Esq.

Huber, Magill, Lawrence and Farrell 99 Park Avenue New York, New York 10016 Ira Lee Zebrak, Esq.

Huber, Magill, Lawrence and Farrell 99 Park Avenue New York, New York 10016 Dr. Arthur Tamplin c/o Natural Resources Defense Council 917 - 15th Street, N.W.

Washington, D.

C.

20005

  • Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Jeffrey Cohen, Esq.

Deputy Commissioner and Counsel New York State Energy Office Agency Building 2 Empire State Plaza

Albany, New York 12223 CarI G.

Dworkin., Esq.

Senior Attorney for Energy New York State Department of Envi ronmenta1 Cons ervati on 50 Wolf Road.

Albany, New York 12233
  • Atomic Safety and Licensing Appeal Panel U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

In the Matter of PUBLIC SERVICE COMPANY OF INDIANA, INC.

WABASH VALLEY POWER ASSOCIA. ION, INC.

'Marble Hill Nuclear Generating

Station, Units 1 and 2)

)

)

)

Docket Nos.

STN 50-546

)

STN 50-547

)

)

)

Richard S.

Salzman, Esq.,

Chairman*

Atomic Safety and Licensina Appeal Board U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555

.1ohn H. Buck+

'tomic Safety and Licensina Appeal Board U. S. Nuclear Requlatory Commission Washington, D.

C.

20555 Michael C. Farrar, Esa.

  • Atomic Safety and'icensino Aooeal Board U.

S,. Nuclear Regulatory'ommission Washinqton, D.

C.

20555 Elizabeth,-S.

Bowers, Eso.,

Chairman*

Atomic Safety and Licensing Board U.

S. Nuclear Peoulatory Commission Washington, D. C.

20555 Mr. Gustave A..Linenberger+

Atomic Safety and Licensing Board U. S. Nuclear Regulatory Cormission

'ashington, D.

C.

20555.

Walker.....C. Cunningham,,'r.,

Esq.

1129 Kentucky Home Life, Building Office of the.Jefferson County Attorney Louisville, Kentucky 40202 Or. Ouentin

). Stober Fisheries Research Institute University of Washington

Seattle, llashinqton 98195 Robert Grav Rura.l Route

Ã1

Hanover, Indiana 47243 Harry H. Voiqt, Esq.-

Le Boeuf, Lamb, Lei by and MacRae 1757 N Street,.N.

W.

Washinqton, D.

C.

20036 Charles

!!. Camnbell, Esa.

Vice President and General Counsel Public Service Comoany of Indiana 1000 East Hain Street Plainfield, Indiana 46168 Peter F.

Mann>ng, Eso.

Assistant Director of Law City of Louisville.

200 City Hall Loui svi 1 1 e, Kentucky 40202 David K. Martin, Esq.

Assistant Attorney General Room 34, State Capitol Frankfort, Kentucky 40601

Ted R. Todd, Esq.

Attorney for the Board of Commissioners of the County of Jefferson, Indiana P.O.

Box 4007 427 East Main Street Madison, Indiana 47250 Thomas M. Datti lo, Esq.

404 East Main Street Madison; Indiana 47250

,Ralph C. Pickard Environmental Management Board of the State of Indiana 1330 West Michigan Street Indianapolis, Indiana 46206 Mrs. David G.

Frey Indiana Sassafras Audubon Society 2625 S.

Smith Road Bloomington, Indiana 47401" Robert C. Slover Save the Valley, Inc.

P.O.

Box 813 Madison, Indiana 47250 Donald J. Ridings, Esq.

Attorney for Jefferson

County, KY 610 Old Louisville Trust Building Louisville, KY

<0202 George A. Leininger, Jr

, Esq.

City Attorney, City of Madison 1327 Iroquois Drive, P.O.

Box 826

Madison, Indiana 47250 J.

Bruce Miller, Esq.

Jefferson County Attorney 1129 Kentucky Home Life Building Louisville, KY 40202 Mrs. Marie Horine, President Save Marble Hill Route 2

Le'xington, Indiana 47138 Joseph B. Helm, Esq.

Brown, Todd 8 Heyburn Sixteenth Floor, Citizens Plaza Louisville, KY 40202 Michael J. Walro, Esq.

Attorney for the Plan Board and the Board of Zoning Appeals of Jefferson County, Indiana 427 East Main Street

Madison, Indiana 47250 Atomic Safety and Licensing Appeal Board*

U.S. Nuclear Regulatory Commission Washington, DC 20555 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Docketing and Service Section*

Office of the'Secretary U.S. Nuclear Regulatory Commission Washington, DC 20555

In the Hatter of DUKE POWER COMPANY (William B. HcGuire Nuclear Station, Units 1

and 2)

)

)

)

)

)

)

Docket Nos.

50-369 50-370

  • Robert H. Lazo, Esq.,

Chairman Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.

G.

20555

  • Dr.

Emmeth A. Luebke Atomic Safety 'and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.

C. '0555, Dr.'adet H. Mand, Jr., Director Bodega Marine Lab of California P.O.

Box 247 Bodega,Bay, California 94923 J.

Michael McGarry, III, Esq.

Debevoise 5 Liberman 1200 Seventeenth

Street, N.W.

Washington, D.

C.

20036 William Larry Porter, Esq.

Associate General Counsel Duke Power Company P.O.

Box 2178 422 South Church Street Charlotte, North Carolina Hr. Jesse L. Riley, President Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207

+ Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C'.

20555

  • Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission-Washington, D. C.

20555 Shelley Blum, Esq.

418 Law Building 730 East Trade Street Charlotte, North Carolina 28202

In the Matter of, VIRGINIA ELECTRIC AND POWER COMPANY (North Anna Nuclear Power Station, Units 1 and 2)

)

)

)

Docket Nos; 50-338 OL

)

50-339 OL

)

)

Alan S. Rosenthal, Esq.,'hairman*

Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Dr. Paul W. Purdom, Director Environmental Studies Institute Drexel University 32nd

& Chestnut Streets Philadelphia, Pennsylvania

  • 19104 Dr. John Buck*

Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Michael C. Farrar, Esq.*

Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Mr. Bradford Whitman.

Assistant Chief Pollution Control. Section U.S. Justice Department Room 2623 10th Street

& Pennsylvania

Avenue, N.W.

Washington, D.C.

20530 Mr. R.

B. Briggs 110 Evans Lane Oak Ridge, Tennessee 37830 Michael W. Maupin, Esq.

Hunton

& Williams P.

O.

Box 1535

'ichmond, Virginia 23212 Richard Foster, Esq.

1908 A Lewis Mountain Road "Charlottesville, Virginia 22903 Mr.. James M. Torson 501 Leroy

Socorro, New Mexico 87801 Mrs.

James C. Arnold Box 3951 Charlottesville, Virginia 22903

John J.

Runzer, Esq.
Pepper, Hamilton

& Schea tz 123 South Broad Street Philadelphia, Pennsylvania 19109 Mr. Dean P.

Agee

,, Executive Secretary

'Board of Supervisors Louisa Courthouse Louisa, Virginia '23090 Dr. Kenneth A.,McCollom Assistant Dean College of Engineering Oklahoma State University Stillwater, Oklahoma 74074 Anthony Gambardella, Esq.

Office. of the Attorney General 11 South 12th Street Room 308 Richmond, Virginia 23219 Mrs. June Allen 412 Owens Drive Huntsville, Alabama 35801 Mrs. Margaret Dietrich Route 2, Box 568 Gordonsville, Virginia 22042 William H. Rodgers, Jr.,

Esq.

Georgetown University Law Center 600 New, Jersey

Avenue, N.W.

,Washington, D.

C.

20001 Ellyn R.'eiss, Esq.

Sheldon, Harmon, Roisman

& Weiss 1025 15th Street, N.W.

Suite 500 Washington, D.C.

20005 Atomic Safety and Licensing Board Panel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing, Appeal Panel (5)*

U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Docketing and Service Section (3)*

Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555

In the Matter of PORTLAND GENERAL ELECTRIC COMPANY (Pebble Sorings Nuclear Plant, Units 1

and 2)

Docket Nos.

50-514 50-515 Alan S. Rosenthal, Esa.,

Chairman Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Dr. Lawrence R. quarles Atomic Safety and Licensing Appeal Board U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555 Richard S. 'Salzman, Esq.

Atomic Safety. and Licensinq Appeal Board U.

S. Nuclear Requlatory Commission Washington, D.

C.

20555 James R. Yore, Esq.,

Chafrman Atomic Safety and Licensing Board U. S. Nuclear Regulatory Cormission Washington, D.

C.

20555 Dr. William E. Martin Seni or Ecol ogist Battelle Memorial Institute

Columbus, Ohi o 43201 Dr. Walter H. Jordan 881 West Outer Drive Oak Ridge, Tennessee 37830 H.

H. Phillips, Esq.

Vice President, Coroorate Counsel and Secretary 121 S.

!J.

Salmon Street

Portland, Oreoon 97204 Richard M. Sandvi k,- Esq.

Department of Justice

'20 S..W.

Yamhi 11

Portland, Oreaon, 97204 Mr. Lloyd K. Marbet Forelaws on Board 19142 S.

Bakers Ferry Road Boring, Oregon 97009

Donald W. Godard, Supervisor Siting and Regulation Department of Energy P~nm 111; Lahor a~~ Tndustries Bldg.

Salem, Oregon 97310 Hs. Bernice Ireland Coalition for Safe Power 10544 N.E.

Simpson

Portland, Oregon 97220

. Kathleen H. Shea, Esq.

Lowenstei n,

Newman, Reis

& Axelrad 1025 Connecticut

Avenue, N.W.

Washington, D.

C.

20036 Frank Josselson, Esq.

William L. Hallmark, Esq.

R. Elaine Hallmark, Esq.-

8th Floor

" One Southwest Columbia

Portland, Oregon 97258 Atomic Safety and Licensing Appeal Panel U. S.

Nuclear Regulatory Commission Washington, D.

C.

20555 Atomic Safety and Licensing Board Panel U." S. Nuclear Pegulatory Commission Washington, D.

C.

20555 Docketing and Service Section Office of the Secretary U. S. Nuclear Regulatory Coranission Washington, D.

C.

20555

In the Matter of

DUKE-POWER COMPANY (Perkins Nuclear Station Units 1, 2 and 3)

Docket Nos.

STN 50-488 STN 50-489, STN 50-490

. *Elizabeth S.

Bowers, Esq.,

Chairman Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. Donal,d P. deSylva Associat'e Professor of Marine Science Rosenstiel School of, Marine and Atmospheric Science

,University of Miami Miami, Florida 33149 Dr.

Wal ter H. Jordan 881 W. Outer Drive Oak Ridge, Tennessee

=37830 J. Michael McGarry, III, Esq.

Debevoise and Liberman

- 1200 Seventeenth

Street, N.W.

Washington, D.C.

20036 William A. Raney, Jr.,

Esq.

Speci al Deputy Attorney General P.O.

Box 629 Raleigh, North Carolina

.27602 William L. Porter, Esq.

Associate General Counsel Duke Power Company 422 South Church Street Charlotte.

North Carolina 28242 William G. 'Pfefferkorn Esq.

P.O.

Box 43 Winston-Salem,

.North Carolina 27102

'rs.

Mary Davis Route 4

Box 261 Mocksville, North. Carolina 27028

~Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555

+Atomic Safety and Licensing Appeal Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Rocketing and Service Section Office of.,the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555

In the Matter of

).

)

BOSTON EDISON COMPANY, et al.

Docket No.

50-471 (Pil grim Nuclear Generating Station,

)

Unit 2.)

)

  • Edward Luton, Esq.

Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Dr. A. Dixon Callihan Union Carbide Corporation P. 0.

Box Y

Oak Ridge, Tennessee 37830

  • Dr. Richard F. Cole Atomic -Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 George H. Lewald, Esq.

Ropes 8 Gray 225 Franklin Street

Boston, Massachusetts 02110 Dale G. Stoodley, Es'q.

'oston Edison Company 800 Boylston Street Boston, Massachusetts

02199, Henry Herrmann, Esq.

Room 1045 50 Congress Street

Boston, Massach'usetts 02108 Mr. and M'"s Alan R. Cleeton 22 Mackintosh Street Franklin, Massachusetts 02038

-The Board of Selectmen Town of Plymouth

Plymouth, Massachusetts 02360 William S. Abbott, Esq.

50, Congress Street, Suite 925 Boston, Massachusetts 02109

(,

  • Atomic Safety and L'icensing Appeal Board U.

S. Nuclear Regulatory

.".ommission Washington, D.

C.

'20555

  • Atomic Safety and Licensing Board Panel U. S.'Nuclear Regulatory Commission Washington, D. C.

20555 Mr. Lester B. Smith Director of Conservation Massachusetts Wildlife Federation P.O.

Box 343

Hatick, MA 01761
  • Docketing and Service Section Office of the Secretary U.. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Laurie Burt, Esq..

Charles Corkin, II, Esq.

Jonathan Brant, Esq.

Assistant Attorneys General Commonwealth of Massachusetts Environmental Protection Division One Ashburton Place, 19th Floor Boston, Massachusetts 02108

In the Matter of PUBLIC SERYICE COMPANY OF NEW HAMPSHIRE, et al.

(Seabrook Station, Units 1

and 2)

Docket Nos. 50-443 50-444 Alan S. Rosenthal, Esq.,

Chairman*

Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Coamission Washington, D. C.

20555 Dr. John H.

Buck"-

Atomic Safety and Licensing

-Appeal Board U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Michael C. Farrar, Esq.*

Atomic Safety and Licen'sing Appeal, Board U. S. Nuclear Regulatory. Commission, Washington, D. C.

20555 Ivan W. Smith, Esq."'tomi'c Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Joseph F. Tubridy, Esq.

4100 Cathedral

Avenue, N.W.

Washington, D.C.

20016 Dr. Marvin M. Mann

  • Atomic Safety'nd Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. Ernest O. Salo Professor of Fisheries Research Institute Colle'ge of Fisheries University of Washington

Seattle, Washington 98195 Dr. Kenneth A. McCollom 1107 West Knapp Street-Stillwater, Oklahoma 74074

Robert A. Backus, Esq.

O'eill, Backus, Spielman, Little 116 Lowell Street Manchester, New Hampshire 03101 Thomas G. Dignan, Jr.,

Esq.

John A. Ritsher,'sq.

Ropes 5 Gray 225 Franklin Street Boston, Massachusetts 02110 Norman Ross, Esq.

30 Francis Street Brookline, Massachusetts 02146 E. Tupper Kinder, Esq.

Assistant Attorney General Office of Attorney General State House Annex Room 208,

Concord, New Hampshire 03301 Laurie Burt, Esq.

Assistant Attorney General Cormonwealth of Massachusetts Environmental: Protection Division One Ashburton Place 19th Floor

Boston, Massachusetts 02108 Karin P. Sheldon, Esq.
Sheldon, Harmon 5 Roisman 1025 15th Street, N.W.

5th Floor Washington, D.C.

20005 Atomic Safety and Licensing Board Panel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing Appeal Board*

U.S. Nuclear Regulatory Coranission Washington, D.C.

20555 Docketing and Service Section*

Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555

In the Matter of CAROLINA POWER AND LI'GHT COMPANY' (Shearon Harris Nuclear Power Plant,

)

Un'its 1, 2, 3 and 4)

)

Docket Nos.

50-400 50-401 50-402 50-403 Ivan W. Smith, Esq.,

Chairman*

Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Gle'nn 0. Bright*

Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. J.

V. Leeds, Jr.

10807 Atwell Drive

Houston, Texas 77096 Richard E. Jones, Esq.

Associate General Counsel Carolina Power

& Light Company 336 Fayetteville, Street

Raleigh, North Carolina 27602 Thomas Erwin, Esq.

115 West Morgan Street Raleigh, North Carolina 27602 Atomic Safety and Licensing Appeal Board*

U.S. Nuclear Regulatory Comnission Washington, D.C.

20555 Atomic Safety and Licensing Board Panel*

U.S. Nuclear Regulatory Coranission Washington, D.C.

20555 Docketing and Service Section*

Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Wake.County Public Library 104 Fayettevil le Street Raleigh, North Carolina 27601

George F. Trowbridge, Esq.

Shaw, Pittman, Potts 8 Trowbridge 1800 M Street, N.W.

Washington, D.C.

20036 Dennis P.

Myers Attorney General's Office State of North Carolina P. 0.

Box 629 Raleigh, North Carolina 27602 Office of,the General Counsel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555

In the Matter of ROCHESTER.GAS AND ELECTRIC CORPORATION, ET AL.

(Sterling Power Project Nuclear Unit No. 1)

Docket No.

STN 50-485 Alan S. Rosenthal, Esq.,

Chairman

  • Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, DC 20555 Dr. John H. Buck
  • Atomic Safety and Licensing Appeal Board U.S.

Nuclear Regulatory Commission Washington, DC 20555 Richard S.

Salzman, Esq.
  • Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, DC 20555 Edward Luton, Esq.
  • Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, DC 20555 Dr. George C. Anderson Department of Oceanography University of Washington
Seattle, Washington 98195 Mr. Lester Kornblith, Jr.
  • Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, DC 20555 Lex K. Larson, Esq.

1757 N Street, N;W.

Washington, DC 20036 Dirk S.

Adams, Esq.

Attorney for Movant Ecology Action of Oswego Office and P.O.

Address 1600 First Federal Plaza Rochester, NY 146I4

Ecology Action Box 94

Oswego, New York 13126 Jeffrey Cohen, Esq.

New York State Energy Office Swan Street Building, Core 1

Second F'loor, Empire State Plaza

Albany, New York 12223 Gerald Charnoff, Esq.

Shaw, Pittman, Potts 5 Trowbridge 1800 N Street, N.W.

'ashington, DC 20036 Ns.

Sharon Morey RD 3

Oswego, New York 13126 Samuel J.

Chi 1k, Secretary*

Office of the Secretary of the Coranission U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing Board Panel

  • U.S. Nuclear Regulatory Commission Washington, DC 20555 Atomic Safety and Licensing Appeal Board
  • U.S. Nuclear Regulatory Commission Washington, DC 20555 Docketing and Service Section
  • Office of the Secretary U.S. Nuclear Regulatory Commission Washington, DC

'20555

In the Matter of FLORIDA POWER 8( LIGHT COMPANY

)

)

(St. Lucie Nuclear Power Plant,

)

Unit 2)

Docket No. 50-389

  • Michael C. Farrar, Esq.,

Chairman Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Dr.

W.

Reed Johnson Atomic Safety and Licensing. Appeal Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555

  • Richard S.
Salzman, Esq.

Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Edward Luton, Esq.,

Chairman Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555 Michael Glaser, Esq., Alternate Chairman Atomic Safety and Licensing Board 1150 17th Street, N.

W.

'Washington, D.

C.

.20036 Dr. David L. Hetrick Professor of Nuclear Engineering University of Arizona Tucson, Arizona 85721 Martin Harold Hodder, Esq.

1131 N.E. 86th Street Miami, Florida 33138 Dr. Frank Hooper Resource Ecology Program School of Natural Resources

'niversity of Michigan Ann Arbor, Michigan 48104 Dr. Marvin M. Mann Alternate Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Harold F. Reis, Esq.

Lowenstein,

Newman, Reis 8 Axelrad 1025 Connecticut
Avenue, N.W.

Washington, D. C.

20036

Norman A, Coll, Esq.

Steel, Hector

& Davis 1400 S.E. First National Bank Bldg.

Miami, Florida 33131 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Atomic Safety and Licensing Appeal Board UPS. Nuclear Regulatory Commission Washington, D. C.

20555 Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.

C.

20555 Mr. Samuel J. Chilk Secretary of the Commission U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

In the Matter of METROPOLITAN EDISON COMPANY, et al.

(Three Mile Island Nuclear Station, Unit.2)

)

Docket Ho. 50-320

)

)

)

)

~ Alan S. Rosenthal, Esq.,

Chairman*

Atomic Safety and Licensing Appeal Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Dr.

W.

Reed

Johnson, Member*

Atomic Safety and Licensing Appeal Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Jerome E. Sharfman, Esq.,

Member*

Atomic Safety and Licensing Appeal-Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Edward Luton, Esq.,

Chairman*

Atomic Safety and Licensing Baord U.S. Nuclear Regulatory Commission Washington, DC 20555 Samuel J. Chilk (12)*

Secretary of the Commission U.S. Nuclear Regulatory Commission Washington, DC 20555 Mr. Gustave A. Linenberger*

Atomic Safety and Licensino Board U.S. Nuclear Regulatory Commission Washington, DC 20555 George F. Trowbridge, Esq.

Shaw, Pittman, Potts 5 Trowbridge 1800 M Street, N.W.

Washington, DC 20555 Dr. Ernest 0. Salo Professor, Fisheries Research Institute, WH-10 College of Fisheries University of Washington

Seattle, Washington 98195 Dr. Chauncey R. Kepford Citizens for a Safe Environment 433 Orlando Avenue State College, Pennsylvania 16801 Karin W. Carter, Assistant Attorney General Office of Enforcement Department of Environmental Resources 709 Health and Welfare Building Harrisburg, Pennsylvania 17120 Ms. Judith H. Johnsrud 433 Orlando Avenue State College, Pennsylvania 16801 Atomic Safety and Licensing Board Panel*

U.S. Nuclear Regulatory Commissio Washington, DC 20555 Atomic Safety and Licensing Appeal Panel (5)*

U.S. Nuclear Regulatory Commission Washington, DC 20555 Docketing and Service Section (3)

Office of the Secretary U.S. Nuclear Regulatory Commission Washington, DC 20555

In the Matter of NORTHERN STATES POWER COMPANY (MINNESOTA) AND NORTHERN STATES ROWER COMPANY (WISCONSIN)

(Tyrone Energy Park, Unit 1)

Docket No.

STN 50-484 Ivan W. Smith, Esq.,

Chairman Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. George C. Anderson Department of Oceanography University of Washington

Seattle, Washington 98195 Mr. Lester Kornblith, Jr.

Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Gerald Charnoff, Esq.

.Shaw, Pittman, Potts 8 Trowbridge 1800 M Street, NW.

Washington, D.C.

20036 Jocelyn F. Olson, Esq.

Minnesota Pollution Control Agency 1935 W. County Road, B2 Roseville, Minnesota 55113 Mr. Tom Galazen R.R.

2 Box 64 Turtle Lake, Wisconsin 54889 Michae'.

Cain, Esq.

, Bureau of Legal Services Department of Natural Resources Box 7921 Madison, Wisconsin 53707

Tyrone Energy Park Mr. Stanley Cider c/o Durand Postmaster Tyrone, Wisconsin 54736 Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commissinn Washington, D.C.

20555 Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Barbara J. Willard, Esq.

Public Service Commission of Wisconsin Hill Farms State Office Bldg.

4802 Sheboygan Avenue Madison, Wisconsin 53702 fir. EdvIard Gold 612-13th Street Menomonie, Wisconsin 54751 Richard Ihrig, Esq.

400 Exchange Building 4th and Center Winona, Minnesota 55987

In the Matter of

)

)

KANSAS GAS AND ELECTRIC COMPANY 5 KANSAS CITY POWER AND LIGHT COMPANY

)

(Wolf Creek Generating Station, Unit No.

1)

Docket No. 50-482 Alan S.

Rosenthal, Esq.,

Chairman Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. John H. Buck Atomic Safety and Licensing Appeal Board U.

S. Nuclear Regulatory Commis'sion Washington, D;C.

20555 Michael C. Farrar, Esq.'tomic Safety and Licensing Appeal Board U. S. 'Nuclear Regulatory Commission Washington,'.-C.

20555 Mr. Lester Kornblith, Jr.

Atomic Safety and Licensing Board U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. George C. Anderson Department of Oceanography, WB-10 University of Washington

Seattle, Washington 98195 Gerald Charnoff, Esq.

Shaw, Pittman, Potts

'8 Trowbridge lQOO M Street, N.W.

Washington, D.C.

20036 Ralph Foster, Esq.

Kansas Gas and Electric Building P.

0.

Box 208

'ichita, Kansas 67201

William H. Griffin, Esq.

Assistant Attorney General Chief, Consumer Protection Division State Capitol Building

Topeka, Kansas 66612 James T. Wiglesworth, Esq.

Rainey, Wiglesworth and Dewey 9800 Metcalf Suite 400 General Square Center Overland Park, Kansas 66212 Edward G. Collister, Jr.

Collister 8 Kampschroeder Attorneys at Law

.1203 Iowa

Lawrence, Kansas 66044 Treva J. Laska, E.sq.

Assistant General Counsel P. 0.

Box 360 Jefferson City, Mo.

65102 Honorable Robert Bennett Governor of Kansas

Topeka, Kansas 66612

)ffice of the County Clerk

/o Jack E. Scott Coffey County Courthouse Burlington, Kansas 66839 Mr. John M. Wylie, II Energy Reporter Kansas City Star 1729 Grand Kansas City, Mo.

64108 Mr. Ernest H. Cannon, Jr.

Chief State Boiler'nspector Kansas Department of Human Resources 610 West 10th, 2nd Floor North

Topeka, Kansas 66612

.Mrs. Diane Tegtmeier 5130 Mission Road Shawnee Mission, Kansas 66205 Atomic.Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety. and Licensing Appeal Board U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Docketing and Service Section Office of the Secretary U. S. Nuclear Regulatory Commission Washington, D.C.

20555 William H. Ward, Esq.

Mid-America Coalition for Energy Alternatives

. 5130 Mission Road Shawnee Mission, Kansas 66205

In the Matter of WASHINGTON PUBLIC POWER SUPPLY SYSTEM (WPPSS Nuclear Project Nos.

1 and 4)

)

)

Docket Nos.

50-460 50-513

  • Richard S.
Salzman, Esq.,

Chairman Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555

  • Dr. John H. Buck Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555

  • Jerome E. Sharfman Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.

C.

20555

  • Robert M. Lazo, Esq.,

Chairman Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555

  • Dr. Marvin Mann Atomic. Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Nicholas D. Lewis, Chairman Energy Facility Siting Evaluation.

Council 820 East Fifth Avenue Olympi,a, Washington 98504 Joseph B. Knotts, Jr.,

Esq.

Nicholas S. Reynolds, Esq.

Debevoise 8 Liberman 700 Shoreham Building 806 Fifteenth Street, N.W.

Washington, D.C.

20005 Richard g. guigley, Esq.

Washington Public Power Supply System P.O.

Box 968

Richland, Washington 99352
  • Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. Donald P. deSylva Assoc; Prof. of Marine Science Rosenstiel School of Marine and Atmospheric Science University of Miami Miami, Florida 33149

  • Atomic Safety and Licensing Appeal Panel*

U.S. Nuclear Regulatory Commission Washington, D.C.

20555

+. Docketing and Service Section

'ffice of the Secretary U.S. Nuclear Regulatory Commission Washington, D.C.

20555

y,ll AK00

<p

+

0

~y 4 ~*y 4'NrI'ED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 SEP 2 5

1978 MEMORANDUM FOR:

Milton J.

Grossman.,

Hearing Division Director and Chief Counsel, OELD FROM:

SUBJECT'.

B. Vassallo, Assistant Director for Light Water Reactors,'ivision of Project Management, NRR BOARD NOTIFICATION - SEMISCALE EXPERIMENT S-A7-6 (BN-78-17)

The enclosed staff memorandum discusses unanticipated results during recent semiscale tests and I think is self-explanatory in terms of in-formation available to date.

Although the memorandum recommends notifying Boards following the avail-abilityy of additional information and a more detailed staff assessment, I feel that the memorandum, as written, should be provided to appropriate PWR Boards at this time.

We will provide the additional information and assessments as soon as they -are available, but the enclosed'emorandum will serve the purpose of alerting Boards of a potential problem.

Our list of PWR cases before Boards in the service list time frame.is as follows:

Cherokee 1-3 Diablo Canyon 1-2 FNP Greene County Jamesport 1-2 Marble Hill 1-2 McGuire 1-2 North Anna 1

Pebble Springs Perkins 1-3 Pilgrim 2 Seabrook Shearon Harris

Sterling, St. Lucie 2 1-2 Three Mile Island 2

Tyrone Wolf Creek WPPSS 4

1-4

. Yellow Creek

Enclosure:

Memo, 0.

Ross-to D. Vassallo dtd. 9/22/78 w/enclosures cc w/enclosure:

See page 2

U. B. Vassallo, Assistant Director for Light Water Reactors Division of Project Management

Milton J.

Grossman SEP 2 5 1978 cc w/enclosure:

H. Oenton E.

Case J.

Davis R.

Boyd R.

DeYoung D. Eisenhut T. Engelhardt L. Nichols B. Grimes J. Stolz, R. Baer

0. Parr Yarga rE (7) 0.

Ross R. Mattson Y. Stello P.

Check T. Novak Z. Rosztoczy T. Murley J. Scinto S.

Hanauer

~pQ R$0(

~6+

tp,

+

0 4 y**4 uNITED sTATEs NUCLEAR REGULATORYCOMMISSION WASHINGTON, D. C. 20555 PEP 2

2, 1978 MEMORANDUM FOR:

D. B. Vassallo, Assistant Director for LMRs,,

DPM FROM:

D. F. Ross, Jr., Assistant Director for Reactor Safety, DSS

SUBJECT:

BOARD NOTIFICATION - RECENT SEMISCALE EXPERIMENT S-A7-6 Semiscale experiment Mod-3, S-A7-6 was run on September 12, 1978.

It was inte'nded to model an integral blowdown-refill-reflood scenario for a double-ended cold-leg break.

On September 21, 1978 INEL staff provided for NRC a briefing of the results of the test.

Some of the results were unanticipated.

For example, the heated core simulator was projected (by Semiscale) to quench at 110 seconds.

Instead, it dried out again and went through several cycles of dryout and rewet (see enclosed Figure 1).

Other portions of the cladding temperature showed similar discrepancies wherein test temperatur were somewhat below predicted (see Figure 2, 3).

During the test the downcomer voided several times in the time span 100-400 seconds.

This was not predicted (Figure 4 shows one such void).

During the periods of downcomer voiding there was also negative (downward) flow from the heater to the lower plenum.

A quick-look report on this experiment will be published about October 1, 1978.

The significance to safety, in the sense of NRR Office Letter No.

19 is in the phrase "whether this information could reasonably be r'egarded as putting a

new or different light upon an issue before Boards or as raising a new issue".

The information from the experiment is that nearly complete downcomer voiding occurred after downcomer fill. This'is not predicted during EM-Appendix K applications.

Also, typical Appendix K calculations do not show successive dryout and rewets over the extended reflood cycle.

The present judgment by INEL is that experimental atypicalities, in particular in the stored heat in the downcomer pipe and in the 1-D arrangement of the downcomer, have produced an atypical and unanticipated result.

In the coming weeks we and INEL intend to further study the issue and find out answers for the questioned experimental atypicality as well as the questioa5d failure of RELAP to have anticipated the result.

D. B. Vassal lo

<<2 QP 2 8 l918 In my judgment, based on the INEL presentation, this experiment does not put in a new or different light the concept of PWR bottom - flooding ECCS.

Nevertheless, it does require us to get more information from a source external to the staff.

It is of sufficient importance to seek further information, first from HRC contractors, and perhaps licensees and vendors in due course.

In this event I conclude that it 'meets the notification test.

In HRR Office Letter 19, Enclosure 1,

page 6-7, I am supposed to provide you the following:

1.

the item for notification; 2.

considerations regarding relevancy and materiality; 3.

'statement on perceived significance;

and, 4.

relation to projects.

1.

The item This memo and the figures show that an integral experiment intended to simulate many of the PWR LOCA phenomena displayed several unanticipated expulsions of water from the downcomer during what was expected to be a tranquil reflood process.

2.

Relevanc and Materialit The experiment is-relevant to all bottom-flooding PWRs.

'I presently doubt that it is material due to perceived atypicality.

3.

~Si Ifi Current staff positions on this subject are through approval of Appendix K models.

If we thought a new phenomenon was discovered, we would alter our, staff positions on those models.

Until the atypicality issue and the code predictability issue is better documented, we do not propose to reopen PWR vendor model approvals.

This position is interim, and based on the expectation that the experiment is atypical and that proof will be available in the order of weeks.

Relation ~Projects This relates to PWRs in general.

As far as documentation is concerned, I believe it is preferable to distribute notification of the October 1 guick-Look Report along with a more. detailed staff assessment of relevancy, materiality, and significance.

COMPARISON OF ROD CLADDING TEMPERATURES AT CORE HIGH POWER ZONE WITH RELAP4 FOR ~~'.T S-A7-6 n

rl

~

f990 0

QOO 0

L t-.i.i))

TH-C3-184 2

TH-A5-184 3

RELAP4 (SRD7)

Time Acier Rupture Coca)

f lgure 2

(p ii00 COMPARISON OF HEASURED AND CALCULATED CLADDING TEHPERAUTRE IN LOWER PART OF CORE FOR TEST S-A7-6 10~30 y TH-E2'-109 TH-C3-11 6

~RELAP4

-58 8

5Q 180 158 208 250 308 350 408 450 580-Tltne Atter Ruptur e Ceb

COHPARISON OF HEASURED AND CALCULATED CLADDING TEHPERATURE I

IN UPPER PART QF CORE FOR TEST S-A7-6 f050

}008 g

9CO b ~0 8Qj3 p)o TH-A3-291

~RELAP4 55U 580 450

CALCULATED COLLAPSED DOWNCOHER LI(UI.D LEVEL FOR TEST S-A7-6 RELAP4 CALCULATION nf LJ Ca d

DATA CALCULATION Time A14yr Rupiur e Ca3

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 K.Jglij SEP 2.2 1978 MEMORANDUM FOR: ~D. B. Vassallo, Assistant Director for LWRs, DPM FROM:

SUBJECT:

D. F. Ross, Jr., Assistant Director for Reactor Safety, DSS BOARD NOTIFICATION - RECENT SEMISCALE EXPERIMENT S-A7-6 Semiscale experiment Mod-3, S-A7-6 was run on September 12, 1978.

It was intended to model an integral blowdown-refill-reflood scenario for a double-ended cold-leg break.

On September 21,.1978 INEL,.staff provided for NRC a briefing of the results of the test.

Some of the results were unanticipated.

For example, the heated core simulator was projected (by Semiscale) to quench at 110 seconds.

Instead, it dried out again and went through several cycles of dryout and rewet (see enclosed Figure 1).

Other portions of the cladding temperature showed similar discrepancies wherein test temper ature4 were somewhat below predicted (see Figure 2, 3).

During the test the downcomer voided several times in the time span 100-400 seconds.

This was not predicted (Figure 4 shows one such void).

During the periods of downcomer voiding ther e was also negative (downward) flow from the heater to the lower plenum.

A quick-look report on this experiment will be published'about October. 1, 1978.

The significance to safety, in the sense of NRR Office Letter No.

19 is in the phrase "whether this information could reasonably be regarded as putting a

new or different light upon an issue before Boards or as raising a new issue".

The information from the experiment is that nearly complete downcomer voiding occurred after downcomer fill. This is not predicted during EM-Appendix K applications.

Also, typical Appendix K calculations do not show successive dryout and rewets over the extended reflood cycle.

The present judgment by INEL is that experimental. atypicalities, in particular in the stored heat in the downcomer'pipe and in the 1-D arrangement of the downcomer, have produced an atypical and unanticipated result.

In the coming'eeks we and INEL intend to further study the issue and find out answers for the questioned experimental a'typicality as yell as the questioIIed fai lure of RELAP to have anticipated the resul,t.

D. B. Vassallo

@pa s >8 In my judgment, based on the INEL presentation, this experiment, does not put in a new or different light the concept of PWR bottom - flooding ECCS.

Nevertheless, it does'equire us to get more information from a source exte'mal to the staff. It is of sufficient importance to seek further information, first from NRC contractors, and perhaps licensees and vendors in due course.

In this event I conclude that it meets the notification test.

In NRR Office Letter 19, Enclosure 1, page 6-7, I am,supposed to provide you the following:

1.

the item for notification;

2. 'onsiderations regarding relevancy and materiality; 3.

statement on perceived significance;

and, 4.

relation to projects.

1.

The item h

This, memo and the figures show that an integral experiment intended to simulate many of the PWR LOCA phenomena displayed several unanticipated expulsions of water from the downcomer during what was expected to be a tranquil reflood process.

2.

Relevanc and Materialit'.

4.

The experiment is relevant to all bottom-flooding PWRs.

I presently doubt that it is material due to perceived atypicality.

S~iifi Current staff positions on this subject are through approval. of Appendix K models.

If we thought a new phenomenon was discovered, we would alter our staff positions on those models.

Until the atypicality issue and the code predictability issue is better.

documented, we do not propose to reopen PWR vendor model approvals.

This position is interim, and based on the expectation that the experiment is atypical and that proof will be available in the order of weeks.

Relation <0 Projects This relates to PWRs in general.

As far as documentation is concerned; I believe it is preferable to distribute notification of the October 1 guick-Look Report along with a more detailed staff assessment of, relevancy, materiality, and significance.

D. B. Vassallo 8pp p g %78 I

We could have this by October 15.

If, however, more prompt notification is neede'd, this memo should suffice.

Enclosures:

As stated

'q "ii /

D. F. Ross, Jr;,'ssistant Director for Reactor Safety Division of Systems Safety cc:

R.

V.

R.

D.

B.

P.

T:

Z'.

T.

J.

S.

Mattson Stello Boyd Eisenhut Grimes Check Novak Rosztoczy Murley Scinto Hanauer

Figure I

f'-Q9 COHPARISON OF ROD CLADDING TEHPERATURES AT CORE HIGH POWER ZONE WITH RELAP4 FOR TEST S-A7-6 n

JQQA 0

0 CL l~AO t"'i"l0 1

TH-C3-184 2

TH.-A5-184 3

RELAP4 (SRD7)

Time Attoe Ruptur ~

Ceoe)

Figure.2 f fi10 COHPARISON OF HEASURED AND CALCULATED CLADDING TEHPERAUTRE IN LOWER PART OF CORE FOR TEST S-A7-6 f Ci30

)

TH-E2-109 TH-C3-115

+RELAP4

-58 8

58 1>38 158 288 250 308 358 488 450 588 Time After Ruptur e Ce3

COMPARISON OF MEASURED AND CALCULATED CLADDING TEMPERATURE IN UPPER PART OF CORE'FOR TEST S-A7-6 i050

!008-g Aq 900 TH-C2-277 h~0l1

5Q 780 ig ~0 f..eQ

/&0 TH-'A3-291

~RELAP4 450 480

-50, o

~8 188 i58 288 250 388 358 480 450 500 Twomo Af(or Rupiure Co3

CALCULATED COLLAPSED DOMNCOMER LIQUID LEVEL FOR TEST S-A7-6 RELAP4 CALCULATION C0 cl DATA CALCULATION

- O 60 0=

38 90 188 1i0 120 130 140 158 160 1

0 180 198 00 Time h l4er Rupture (a)

T

'v 1'