Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381 November 4,2016 10 cFR 72.212 ATTN: Document Control Desk Director, Division of Spent Fuel Management, Office of Nuclear Material Safety and Safeguards, Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Units 1 and2 Facility Operating License Nos. NPF-90 and NPF-96 NRC Docket Nos. 50-390, 50-391, and72-1048

Subject:

Watts Bar Nuclear Plant - Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(bl(21 ln accordance with 10 CFR 72.212, "Conditions of General License lssued Under 572.210,"

paragraph (bX2), Watts Bar Nuclear Plant (WBN) is registering with the Nuclear Regulatory Commission (NRC) the use of spent fuel storage casks at WBN's lndependent Spent Fuel Storage lnstallation. Accordingly, WBN provides the following information:

Licensee Name:

Tennessee Valley Authority Licensee Address:

Post Office Box 2000 Spring City, Tennessee 37381-2000 Reactor License Numbers:

Reactor Docket Numbers:

NPF-90 and NPF-96 50-390 and 50-391 Responsible lndividual:

Gordon Arent Director, Watts Bar Nuclear Licensing Cask Certificate Number:

1032, Amendment No. 0, June 13,2011 Cask Mode! Number:

HI-STORM FW MPC Storage System

U.S. Nuclear Regulatory Commission Page 2 November 4,2016 For the initial use of the cask system on Cask ldentification Numbers:

For the initial use of the cask system on Cask ldentification Numbers:

For the initial use of the cask system Cask ldentification Numbers:

For the initial use of the cask system Cask ldentification Numbers:

October 5,2016:

Mu lti-Purpose Canister Type 37 Serial No. 017 Overpack Serial No. 029 October 14,2016:

Mu lti-Purpose Can ister Type 37 Serial No. 117 Overpack Serial No. 030 on October 21,2016:

Mu lti-Purpose Canister Type 37 Serial No. 019 Overpack Serial No. 031 on October 28,2016:

Multi-Purpose Canister Type 37 Serial No. 020 Overpack Serial No. 032 This document contains no regulatory commitments.

Please direct any questions concerning this matter to Gordon Arent, WBN Licensing Director, at (423) 365-2004.

Respectfully, /

Paul Simmons Site Vice President Watts Bar Nuclear Plant cc:

NRC Regional Administrator - Region ll NRC Senior Resident lnspector - Watts Bar Nuclear Plant Robert Carrion - Region Il ISFSI Coordinator