UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 3, 2016 Mr. Charles R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.
P.O. Box 1295, Bin 038 Birmingham, AL 35201-1295
SUBJECT:
VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 - CORRECTION TO TECHNICAL SPECIFICATION PAGE FOR AMENDMENT NO. 164 RE: ISSUANCE OF AMENDMENT FOR 2B NUCLEAR SERVICE COOLING WATER TRANSFER PUMP (CAC NO. MF8274)
Dear Mr. Pierce:
By letter dated October 31, 2016 (Agencywide Documents Access and Management System Accession No. ML16265A162), the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 164 to Renewed Facility Operating License No. NPF-81 for the Vogtle Electric Generating Plant, Unit 2. Revised Technical Specification (TS) page 3.7.9-2 contained a typographical error. Specifically, the error consisted of the omission of "Amendment No. 179 (Unit 1 )" at the bottom right of the page. Also, a change bar should have appeared after "Amendment No. 164 (Unit 2)" at the bottom right of the page.
This was an administrative error on the part of the NRC. The correction does not change any of the NRC staff's conclusions in the safety evaluation associated with the license amendment or the no significant hazards consideration determination as published in the Federal Register.
A corrected TS page 3.7.9-2 is enclosed. We apologize if this error has caused any inconvenience.
Docket No. 50-425
Enclosure:
Corrected TS page 3.7.9-2 cc w/enclosure: Distribution via Listserv Sincerely,
/~#fr)~
/Bob Martirf; Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
ENCLOSURE Corrected TS page 3.7.9-2 for Vogtle Electric Generating Plant, Unit 2 for Amendment No. 164 dated October 31, 2016
ACTIONS (continued}
CONDITION D.
One NSCW basin transfer pump inoperable.
E.
Required Action and associated Completion Time not met.
OR UHS inoperable for reasons other than Conditions A, B, C, or D.
Vogtle Units 1 and 2 UHS 3.7.9 REQUIRED ACTION COMPLETION TIME 0.1 QB D.2.1 AND D.2.2 E.1 AND E.2 Restore the transfer 8 days pump to OPERABLE status.
Implement an alternate 8 days method of basin transfer.
Restore the transfer
NOTE-------
pump to OPERABLE A one-time only status.
change of the Completion Time to 46 days is permitted for the 28 NSCW transfer pump refurbishment during Vogtle Unit 2, Cycle 19. The increased Completion Time is applicable only to the 28 NSCW transfer pump.
31 days Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />
NOTE-----------
LCO 3.0.4.a is not applicable when entering MODE4.
Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 3.7.9-2 Amendment No. 179 (Unit 1)
Amendment No. 164 (Unit 2)
ML16308A225 OFFICE DORL/LPL2-1/PM DORL/LPL2-1/LA DORL/LPL2-1 /BC NAME BMartin LRonewicz MMarkley DATE 11/03/16 11/03/16 11/03/16