CNL-16-144, Use of Encryption Software for Electronic Transmission of Safeguards Information

From kanterella
(Redirected from ML16302A438)
Jump to navigation Jump to search

Use of Encryption Software for Electronic Transmission of Safeguards Information
ML16302A438
Person / Time
Site: Browns Ferry, Watts Bar, Sequoyah  Tennessee Valley Authority icon.png
Issue date: 10/28/2016
From: James Shea
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CNL-16-144
Download: ML16302A438 (11)


Text

Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-16-144 October 28, 2016 10 CFR 73.22 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296 Sequoyah Nuclear Plant, Units 1 and 2 Renewed Facility Operating License Nos. DPR-77 and DPR-79 NRC Docket Nos. 50-327 and 50-328 Watts Bar Nuclear Plant, Units 1 and 2 Facility Operating License Nos. NPF-90 and NPF-96 NRC Docket No. 50-390 and 50-391

Subject:

Use of Encryption Software for Electronic Transmission of Safeguards Information

References:

1.

NRC Regulatory Guide 5.79, Protection of Safeguards Information, April 2011

2.

NRC Regulatory Issue Summary 2002-15, Revision 1, NRC Approval of Commercial Data Encryption Systems for the Electronic Transmission of Safeguards lnformation, dated January 26, 2006 Pursuant to the requirements of Title 10 of the Code of Federal Regulations (10CFR) 73.22(f)(3) and the guidance provided in Nuclear Regulatory Commission (NRC) Regulatory Guide 5.79 (Reference 1) and Regulatory Issue Summary 2002-15, Revision 1 (Reference 2), Tennessee Valley Authority (TVA) requests approval to process and transmit safeguards information (SGI) using Symantec Endpoint Encryption by PGP Technology, 11.1, or the latest validated version.

This version of encryption product was developed with PGP Cryptographic Engine Software Version 4.3 and complies with Federal Information Processing Standard (FIPS) 140-2 as validated by the National Institute of Standards and Technology (NIST) Consolidated Certificate No. 0053 (Enclosure).

U.S. Nuclear Regulatory Commission CNL-16-144 Page 2 October 28, 2016 TVA has and continues to maintain an established written procedure in place that describes, as a minimum: access controls; where and when encrypted communications can be made; how encryption keys, codes and passwords are protected from compromise; actions to be taken if the encryption keys, codes or passwords are, or are suspected to have been, compromised (such as notification of all authorized users); and how the identity and access authorization of the recipient will be verified.

TVA intends to exchange SGI with the NRC, Nuclear Energy Institute, and other SGI holders who have received NRC approval to use PGP software. Pursuant to 10 CFR 73.22(f)(3), the transmission of encrypted material to other authorized SGI holders who have received NRC approval to use PGP software would be considered a protected telecommunications system.

The transmission and dissemination of unencrypted SGI is subject to the provisions of 10 CFR 73.22(g).

Patrick J. Asendorf, Senior Program Manager, Security Regulatory Oversight, is responsible for the overall implementation of the SGI encryption program at TVA. Mr. Asendorf is also responsible for collecting, safeguarding and disseminating the software tools needed for encryption and decryption of SGI.

There are no new regulatory commitments contained in this submittal. If you have any questions concerning this matter, please contact Patrick J. Asendorf at (423) 751-8150.

Respectfully, J. W. Shea Vice President, Nuclear Licensing

Enclosure:

FIPS 140-2 Consolidated Certificate No. 0053 cc (Enclosure):

NRC Regional Administrator - Region II NRC Senior Resident Inspector-Browns Ferry Nuclear Plant NRC Senior Resident Inspector - Sequoyah Nuclear Plant NRC Senior Resident Inspector - Watts Bar Nuclear Plant NRC Project Manager - Browns Ferry Nuclear Plant NRC Project Manager - Sequoyah Nuclear Plant NRC Project Manager-Watts Bar Nuclear Plant

ENCLOSURE FlPS 140-2 Consolidated Certificate No. 0053

FIPS 140-2 Consolidated Validation Certificate The National Institute of Standards and Technology of the United States of America The Communications Security EstabHshment of the Government of Canada Consolidated Certificate No. 0053 The National Institute of Standards and Technology, as the United States FIPS 140-2 Cryptographic Module Validation Authority; and the Communications Security Establishment Canada, as the Canadian FIPS 140-2 Cryptographic Module Validation Authority; hereby validate the FIPS 140-2 testing results of the cryptographic modules listed below in accordance with the Derived Test Requirements for FIPS 140-2, Security Requirements for Cryptographic Modules. FIPS 140-2 specifies the security requirements that are to be satisfied by a cryptographic module utilized within a security system protecting Sensitive Information (United States) or Protected Information (Canada) within computer and telecommunications systems (including voice systems).

Products which use a cryptographic module identified below may be labeled as complying with the requirements of FIPS 140-2 so long as the product, throughout its life-cycle, continues to use the validated version of the cryptographic module as specified in this consolidated certificate.

The validation report contains additional details concerning test results. No reliability test has been performed and no warranty of the products by both agencies is either expressed or implied.

FIPS 140-2 provides four increasing, qualitative levels of security: Level 1, Level 2, Level 3, and Level 4. These levels are intended to cover the wide range and potential applications and environments in which cryptographic modules may be employed. The security requirements cover eleven areas related to the secure design and implementation of a cryptographic module.

The scope of conformance achieved by the cryptographic modules as tested are identified and listed on the Cryptographic Module Validation Program website. The website listing is the official list of validated cryptographic modules. Each validation entry corresponds to a uniquely assigned certificate number. Associated with each certificate number is the module name(s}, module versioning information, applicable caveats, module type, date of initial validation and applicable revisions, Overall Level, individual Levels if different than the Overall Level, FIPS-approved and other algorithms, vendor contact information, a vendor provided description and the accredited Cryptographic Module Testing laboratory which performed the testing.

Signature:-~....,.;,.;............ ~"""""""""'""'........... __..._

Dated:

Chief, Computer Security Division National Institute of Standards and Technology Page 1of8

...___.~ e Gov;r?m1 of Canada Signature:

~~

---~~~..,...~~_;_......;;;;...~~~~~~~

Dated:

'5 ~ u.:ng_, 2..o~ c; Director, Architecture and Technology Assurance Communications Security Establishment Canada

  • . il !

6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Number Validation /

Posting Date Module Name(s)

Vendor Name Version Information 2356 05/19/2015 Kernel Mode Cryptographic Primitives Library (cng.sys) in Microsoft W indows 8.1 Enterprise, W indows Server 2012 R2, W indows Storage Server 2012 R2, Surface Pro 3, Surface Pro 2, Surface Pro, Surface 2, Surface, W indows RT 8.1, Windows Phone 8.1, W indows Embedded 8.1 Industry Enterprise, StorSimple 8000 Series Microsoft Corporation Software Versions: 6.3.9600 and 6.3.9600.17042 2365 5/4/2015 Cisco Systems 5508 Wireless LAN Controller Cisco Systems, Inc.

Hardware Version: 5508 with 5508 FIPS kit (AIR-CT5508FIPSKIT=)

and CN56XX; Firmware Version:

8.0 with SNMP Stack v15.3, OPENSSL-0.9.8g-8.0.0, QUICKSEC-2.0-8.0 and FP-CRYPTO-7.0.0 2366 5/4/2015 FortiGate-60C/60D/80C and FortiW iFi-60C/60D Fortinet, Inc.

Hardware Versions: C4DM93 [1],

C1AB28 [2], C4BC61[3], C4DM95

[4], and C1AB32 [5] with Tamper Evident Seal Kits: FIPS-SEAL-BLUE [3] or FIPS-SEAL-RED

[1,2,4,5]; Firmware Version: 5.0, build0305, 141216 2367 5/4/2015 FortiGate-100D, FortiGate-200B, FortiGate-200D, FortiGate-300C, FortiGate-600C and FortiGate-800C Fortinet, Inc.

Hardware Versions: C4LL40 [1],

C4CD24 [2], C4KV72 [3], C4HY50

[4], C4HZ51 [5] and C4LH81 [6] with Tamper Evident Seal Kits: FIPS-SEAL-BLUE [2] or FIPS-SEAL-RED

[1,3,4,5,6]; Firmware Version: 5.0, build0305,141216 2368 5/4/2015 FortiGate-1000C, FortiGate-1240B, FortiGate-3140B and FortiGate-3240C Fortinet, Inc.

Hardware Versions: C4HR40 [1],

C4CN43 [2], C4XC55 [3] and C4KC75 [4] with Tamper Evident Seal Kits: FIPS-SEAL-RED [1,3,4]

or FIPS-SEAL-BLUE [2]; Firmware Version: FortiOS 5.0, build0305,141216 Page 2 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Number Validation /

Posting Date Module Name(s)

Vendor Name Version Information 2369 5/4/2015 FortiGate-1500D and 3700D Fortinet, Inc.

Hardware Versions: C1AA64 [1] and C1AA92 [2] with Tamper Evident Seal Kits: FIPS-SEAL-RED [1,2];

Firmware Version: FortiOS 5.0, build0305,141216 2370 5/4/2015 FortiOS' 5.0 Fortinet, Inc.

Firmware Version: 5.0, build0305, 141216 2371 5/4/2015 FortiGate-3600C and FortiGate-3950B Fortinet, Inc.

Hardware Versions: C4MH12,

[C4DE23 with P06698-02] with Tamper Evident Seal Kits: FIPS-SEAL-RED; Firmware Version:

FortiOS 5.0, build0305,141216 2372 05/05/2015 FortiGate-5140B Chassis with FortiGate/FortiSwitch 5000 Series Blades Fortinet, Inc.

Hardware Version: Chassis:

P09297-01; Blades: P4CJ36-04, P4EV74, C4LG17 and P4EX84; AMC Component: P4FC12; Air Filter: PN P10938-01; Front Filler Panel: PN P10945-01: ten; Rear Filler Panel: PN P10946-01:

fourteen; Tamper Evident Seal Kit:

FIPS-SEAL-RED; Firmware Version: FortiOS 5.0, build0305, 141216 2373 05/05/2015 Neopost Postal Security Device (PSD)

Neopost Technologies, S.A.

Hardware Version: A0014227-B; Firmware Version: a30.00; P/N:

A0038091-A 2374 05/08/2015 Avaya WLAN 9100 Access Points Avaya Inc.

Hardware Versions: P/Ns W AO912200-E6GS [1],

W AP913200-E6GS [2],

W AP913300-E6GS [2],

W AP917300-E6GS [2]; Enclosure (Form Factor): WAO912200-E6GS

[1], W AB910003-E6 [2]; SKU W LB910001-E6; Firmware Version:

AOS-7.1 2375 05/20/2015 HP P-Class Smart Array RAID Controllers Hewlett-Packard Development Company, L.P.

Hardware Versions: P230i, P430, P431, P731m, P830, and P830i; Firmware Version: 1.66 Page 3 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Number Validation /

Posting Date Module Name(s)

Vendor Name Version Information 2376 05/21/2015 Aegis Secure Key 3.0 Cryptographic Module Apricorn Inc.

Hardware Version: RevD; Firmware Version: 6.5 2377 5/21/2015 Symantec PGP Cryptographic Engine Symantec Corporation Software Version: 4.3 2379 05/21/2015 Ciena 6500 Packet-Optical Platform 4x10G Ciena Corporation Hardware Version: 1.0; Firmware Version: 1.10 2380 05/21/2015 Samsung UFS (Universal Flash Storage) Shark SED Samsung Electronics Co., Ltd.

Hardware Versions: KLUAG2G1BD-B0B2, KLUBG4G1BD-B0B1, KLUCG8G1BD-B0B1; Firmware Version: 0102 Page 4 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Validation /

Module Name(s)

Vendor Name Version Information Number Posting Date 2381 05/21/2015 Brocade MLXe, Brocade Brocade Communications NetIron CER 2000 Ethernet Systems, Inc.

Routers and Brocade CES 2000 Routers and Switches Hardware Versions: {[BR-MLXE MR-M-AC (P/N: 80-1006853-01),

BR-MLXE-4-MR-M-DC (P/N: 80-1006854-01), BR-MLXE-8-MR-M-AC (P/N: 80-1004809-04), BR-MLXE-8-MR-M-DC (P/N: 80-1004811-04), BR-MLXE-16-MR-M-AC (P/N: 80-1006820-02), BR-MLXE-16-MR-M-DC (P/N: 80-1006822-02), BR-MLXE-4-MR2-M-AC (P/N: 80-1006870-01), BR-MLXE-4-MR2-M-DC (P/N: 80-1006872-01), BR-MLXE-8-MR2-M-AC (P/N: 80-1007225-01), BR-MLXE-8-MR2-M-DC (P/N: 80-1007226-01), BR-MLXE-16-MR2-M-AC (P/N: 80-1006827-02), BR-MLXE-16-MR2-M-DC (P/N: 80-1006828-02)] with Component P/Ns 80-1006778-01, 80-1005643-01, 80-1003891-02, 80-1002983-01,80-1003971-01,80-1003972-01, 80-1003811-02, 80-1002756-03, 80-1004114-01,80-1004113-01,80-1004112-01, 80-1004760-02, 80-1006511-02, 80-1004757-02, 80-1003009-01, 80-1003052-01, 80-1003053-01, NI-CER-2048F-ADVPREM-AC (P/N: 80-1003769-07), NI-CER-2048F-ADVPREM-DC (P/N: 80-1003770-08), NI-CER-2048FX-ADVPREM-AC (P/N: 80-1003771-07), NI-CER-2048FX-ADVPREM-DC (P/N: 80-1003772-08), NI-CER-2024F-ADVPREM-AC (P/N: 80-1006902-02), NI-CER-2024F-ADVPREM-DC (P/N: 80-1006904-02), NI-CER-2024C-ADVPREM-AC (P/N: 80-1007032-02), NI-CER-2024C-ADVPREM-DC (P/N: 80-1007034-02), NI-CER-2048C-ADVPREM-AC (P/N: 80-Page 5 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Number Validation /

Posting Date Module Name(s)

Vendor Name Version Information 1007039-02), NI-CER-2048C-ADVPREM-DC (P/N: 80-1007040-02), NI-CER-2048CX-ADVPREM-AC (P/N: 80-1007041-02), NI-CER-2048CX-ADVPREM-DC (P/N: 80-1007042-02), BR-CER-2024F-4X-RT-DC (P/N: 80-1007212-01), BR-CER-2024C-4X-RT-DC (P/N: 80-1007213-01), BR-CER-2024F-4X-RT-AC (P/N: 80-1006529-01), BR-CER-2024C-4X-RT-AC (P/N: 80-1006530-01), NI-CER-2024C-2X10G (P/N: 80-1003719-03), BR-CES-2024C-4X-AC (P/N: 80-1000077-01), BR-CES-2024C-4X-DC (P/N: 80-1007215-01), BR-CES-2024F-4X-AC (P/N: 80-1000037-01), BR-CES-2024F-4X-DC (P/N:

80-1007214-01), RPS9 (P/N: 80-1003868-01) and RPS9DC (P/N: 80-1003869-02)} with FIPS Kit XBR-000195; Firmware Version: Multi-Service IronWare R05.7.00 2382 05/21/2015 HGST Ultrastar 7K6000 TCG Enterprise HDDs HGST, Inc.

Hardware Versions: P/Ns HUS726060AL5215 (0001);

HUS726060AL4215 (0001);

HUS726050AL5215 (0001);

HUS726050AL4215 (0001);

HUS726040AL5215 (0001);

HUS726040AL4215 (0001);

HUS726030AL5215 (0001);

HUS726030AL4215 (0001);

HUS726020AL5215 (0001);

HUS726020AL4215 (0001);

Firmware Version: R519 2383 05/21/2015 HP Virtual Connect 16Gb 24-Port FC Module Hewlett-Packard Company Hardware Version: 40-1000779-08 Rev C (80-1007799-04); Firmware Version: VC 4.40 Page 6 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Validation /

Module Name(s)

Vendor Name Version Information Number Posting Date 2384 05/21/2015 Brocade DCX, DCX 8510-8, DCX-Brocade Communications 4S and DCX 8510-4 Backbones, Systems, Inc.

6510 FC Switch, 6520 FC Switch and 7800 Extension Switch Hardware Versions: {[DCX Backbone (P/Ns 80-1001064-10, 80-1006751-01, 80-1004920-04 and 80-1006752-01), DCX-4S Backbone (P/Ns 80-1002071-10, 80-1006773-01, 80-1002066-10 and 80-1006772-01), DCX 8510-4 Backbone (P/Ns 80-1004697-04, 80-1006963-01, 80-1005158-04 and 80-1006964-01),

DCX 8510-8 Backbone (P/Ns 80-1004917-04 and 80-1007025-01)]

with Blades (P/Ns 80-1001070-07, 80-1006794-01, 80-1004897-01, 80-1004898-01, 80-1002000-02, 80-1006771-01, 80-1001071-02, 80-1006750-01, 80-1005166-02, 80-1005187-02, 80-1001066-01, 80-1006936-01, 80-1001067-01, 80-1006779-01, 80-1001453-01, 80-1006823-01, 80-1003887-01, 80-1007000-01, 80-1002839-03, 80-1007017-01, 49-1000016-04, 49-1000064-02 and 49-1000294-05),

6510 FC Switch (P/Ns 80-1005232-03, 80-1005267-03, 80-1005268-03, 80-1005269-03, 80-1005271-03 and 80-1005272-03), 6520 FC Switch (P/Ns 80-1007245-03, 80-1007246-03, 80-1007242-03, 80-1007244-03, 80-1007257-03), 7800 Extension Switch (P/Ns 80-1002607-07, 80-1006977-02, 80-1002608-07, 80-1006980-02, 80-1002609-07 and 80-1006979-02)} with FIPS Kit P/N Brocade XBR-000195; Firmware Version: Fabric OS v7.2.1 (P/N 63-1001421-01) 2385 05/22/2015

µMACE Motorola Solutions, Inc.

Hardware Version: P/N AT58Z04; Firmware Version: R01.07.01 Page 7 of 8 6/1/2015

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm Certificate Number Validation /

Posting Date Module Name(s)

Vendor Name Version Information 2386 05/22/2015 Hitachi Virtual Storage Platform (VSP) Encryption Engine Hitachi, Ltd.

Hardware Version: R800L1; Firmware Version: 02.09.28.00 and 02.09.32.00 2387 05/22/2015 HP XP7 Encryption Ready Disk Adapter (eDKA) Level1 Hewlett-Packard Company Hardware Version: R800L1; Firmware Version: 02.09.28.00 and 02.09.32.00 2388 05/28/2015 IOS Common Cryptographic Module (IC2M) Rel5 Cisco System, Inc.

Firmware Version: Rel 5 Page 8 of 8 6/1/2015