ML16294A326

From kanterella
Jump to navigation Jump to search
Lr Hearing - (External_Sender) Ucs Bolt Assessment of Operability
ML16294A326
Person / Time
Site: Indian Point  
Issue date: 09/08/2016
From:
- No Known Affiliation
To:
Division of License Renewal
References
Download: ML16294A326 (3)


Text

1 IPRenewal NPEmails From:

DR WILLIAM CORCORAN <williamcorcoran@sbcglobal.net>

Sent:

Thursday, September 08, 2016 6:51 PM To:

Dentel, Glenn Cc:

McKenzie, Kieta; Scott, Michael; Pelton, David

Subject:

[External_Sender] Re: Re: UCS bolt assessment of operability Mr. Dentel, Thanks ever so much.

Do you have the ML# for a root cause analysis?

Take care, Bill Corcoran William R. Corcoran, Ph.D., P.E.

21 Broadleaf Circle Windsor, CT 06095-1634 860-285-8779 William.R.Corcoran@1959.USNA.com http://www.linkedin.com/in/williamcorcoranphdpe https://www.box.com/shared/kfxg1lt9dh On Thursday, September 8, 2016 2:45 PM, "Dentel, Glenn" wrote:

Dear Dr. Corcoran:

As promised in my June 16 email response to you, I am writing to let you know the NRC has issued an inspection report on baffle-former bolting conditions at Indian Point Units 2 and 3. This inspection report can be found by using the NRCs publicly available web-based Agencywide Documents Access and Management System. To retrieve the document, enter the Accession Number (ML16243A245) in the Document Properties field located in the Advanced Search tab at the following webpage:

http://adams.nrc.gov/wba/.

The NRC implemented significant, comprehensive inspections after learning of the degraded baffle-former bolt issues at Indian Point. This included various baseline inspection samples to assess the issue at Unit 2, and the extent of the issue as it pertains to Unit 3. The inspections included reviews of Entergys non-destructive examination techniques and results; observations of a portion of bolt replacement activities on-site; assessments of foreign material controls and loose parts analysis; and reviews of the design change package and evaluations associated with both the degraded and new, replacement baffle-former bolts. Enforcement action was taken for Entergys failure to perform an operability evaluation on the baffle-former bolts associated with Unit 3. All of these inspections and other reviews are documented in the above mentioned report. In summary, NRC inspectors reviewed Entergys actions to address the baffle-former bolting issue and concluded there are no concerns pertaining to the safe operation of Units 2 and 3 Thank you for your concerns about the safe operations of the Indian Point nuclear plant. If you have any questions regarding this email or the inspection report, please contact me at (610) 337-5233.

2 Sincerely, Glenn Dentel, Chief Division of Reactor Projects Branch 2 NRC Region I

Hearing Identifier:

IndianPointUnits2and3NonPublic_EX Email Number:

8360 Mail Envelope Properties (56375569.1251062.1473375056328)

Subject:

[External_Sender] Re: Re: UCS bolt assessment of operability Sent Date:

9/8/2016 6:50:56 PM Received Date:

9/8/2016 6:51:01 PM From:

DR WILLIAM CORCORAN Created By:

williamcorcoran@sbcglobal.net Recipients:

"McKenzie, Kieta" <Kieta.McKenzie@nrc.gov>

Tracking Status: None "Scott, Michael" <Michael.Scott@nrc.gov>

Tracking Status: None "Pelton, David" <David.Pelton@nrc.gov>

Tracking Status: None "Dentel, Glenn" <Glenn.Dentel@nrc.gov>

Tracking Status: None Post Office:

mail.yahoo.com Files Size Date & Time MESSAGE 2312 9/8/2016 6:51:01 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: