ML16263A072

From kanterella
Jump to navigation Jump to search
University of Missouri - Columbia Research Reactor, Regarding Changes to the Emergency Plan Without Prior Commission Approval
ML16263A072
Person / Time
Site: University of Missouri-Columbia
Issue date: 09/15/2016
From: Rhonda Butler, Meffert B
Univ of Missouri - Columbia
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML16263A072 (6)


Text

~ University of Missouri Research Reactor Center 1513 Research Park Drive Columbia, MO 65211 PHONE 5l3-8S2-4211 WEB murr.missouri.edu September 15, 2016 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Mail Station Pl-37 Washington, DC 20555-0001

REFERENCE:

Docket 50-186 University of Missouri-Columbia Research Reactor Amended Facility License R-103

SUBJECT:

Written communication specified in 10 CFR 50.4(b)(5) regarding changes to the University of Missouri Research Reactor Emergency Plan without prior Commission approval pursuant to 10 CFR 50.54(q)

Attached are the September 15, 2016, changes to the University of Missouri Research Reactor (MURR)

Emergency Plan and the justification for each change. Additionally, the revised pages to the Emergency Plan are included to help explain the change.

Changes to the MURR Emergency Plan were performed for the following reason:

1. Updating the agreement between the City of Columbia and MURR, Appendix A These changes do not decrease the effectiveness of the MURR Emergency Plan and are being made without prior Commission approval pursuant to 10 CFR 50.54(q). If you have any questions regarding these changes, please contact me at MeffertB@missouri.edu or by calling (573) 882-5118.

ENDORSEMENT:

Sincerely, Reviewed and Approved

~A.~e~

Reactor Manager .

Ralph A. Butler, P .E.

Director

Enclosures:

1. Attachment 1 - Changes and Justifications to the University of Missouri Research Reactor Facility Emergency Plan
2. Attachment 2-Revised Pages to the University of Missouri Research Reactor Facility Emergency Plan xc w/enclosures: Mr. Johnny Eads, U.S. NRC Mr. Geoffrey Wertz, U.S. NRC

ATTACHMENT 1 Changes and Justifications to the

Appendix A, Page A-1 Update Agreement Letter.

Justification for the change:

This change updates the agreement between the City of Columbia and MURR, in that the City of Columbia Fire Department will respond to fires and other emergency situations should they occur at the facility.

11

ATTACHMENT 2 Revised Pages to the University of Missouri Research Reactor Facility Emergency Plan

LIST OF EFFECTIVE PAGES Page Number Date Revised Title Page I Assignment Sheet ................................................................................... 12/8/89 Table of Contents: ii ................................................................................................... Original

  • List of Effective Page: iii ........................................................................................... 9/15/16 1 ................................................................................................................... 4/13/07 2 ******************************************************************************************************************* 3/30/12 3 ................................................................................................................... 4/13/07 4 ................................................................................................................... 3/19/04 5 .......................... :........................................................................................ 2/20/87 6 ******************************************************************************************************************* 3/19/04 7 ................................................................................................................... 3/19/04 8 ******************************************************************************************************************* 4/13/07 9 ................................................................................................................... 4/13/07 10 ................................................................................................................. 4/13/07 11 ................................................... :............................................................. 3/30/12 12 ................................................................................................................. 9/18/91 13 ................................................................................................................. 3/19/04 14 ................................................................................................................. 3/19/04 15 ................................................................................................................. 3/19/04 16 ................................................ ;................................................................ 3/19/04 17 ................................................................................................................. 3/30/12 18 ................................................................................................................. 3/19/04

- -- -- - _!9_. *-*-~* "_._-_:_:_"_"_'.__"_"" :*. ::*_._._..._._.._.._. ~~~ . ._.._, ... , _._._,_,_._,._._............................................................ 3/19/04 20 ................................................................................................................. 3/30/12 21 ................................................................................................................. 12/28/93 22 ................................................................................................................. 3/19/04 23 ***************************************************************************************************************** 3/19/04 24 ................................................................................................................. 3/30/12 25 ................................................................................................................. 4/13/07 26 ................................................................................................................. 3/30/12 27 ................................................................................................................. 4/13/07 Appendix A (title page) ............................................................................................. Original*

A-1 ............................................................................................................................. 9/15/16 Appendix B (title page) .............................................................................................. Original

  • B-1 .............................................................................................................................. 3/19/04 B-2 .............................................................................................................................. 3/19/04
  • Original page as written in the August 12, 1982, submittal to the NRC; these pages have no revision dates on them.

iii Rev. 9/15/16 I

A-1 CITY OF COLUMBIA, MISSOURI OFFICE OF CITY MANAGER September 7, 2016 Bruce A. Meffert, Reactor Manager University of Missouri - Columbia 1513 Research Park Drive Columbia, MO 65211-3400

Dear Mr. Meffert,

This letter is to provide assurance that the City of Columbia Fire Department will respond to fires or other emergency situations should they occur at the research reactor. We understand that the research reactor staff will continue to conduct training sessions at least every two years for Fire Department personnel, including MURR facility orientation and review of selected health physics procedures specific to the MURR facility. The responsibility for maintaining and scheduling training for our Fire Department, which will participate in such training, will remain with the MURR staff.

Mike Matthes City Manager Cc: Randy White, Fire Chief 701 E. BROADWAY* P.O. Box 6015 ° CoLuMmA, M1ssouR1 65205-6015 (573) 874-7214 ° FAX (573) 442-8828 *TTY (800) 735-2966 vvww. GoCoLUMBIAMo. COM Rev. 9/15/16 I