Text
OFFICIAL USE ONLY - PROPRIETARY INFORMATION January 3, 2018 Brian Burgos MRP Program Manager Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA 94304
SUBJECT:
DRAFT SAFETY EVALUATION OF ACTION ITEMS 1 AND 7 FROM TOPICAL REPORT MRP-227-A, MATERIALS RELIABILITY PROGRAM: PRESSURIZED WATER REACTOR INTERNALS INSPECTION AND EVALUATIONS GUIDELINE (CAC NO. MF7223 EPID: L-2016-TOP-0001)
Dear Ms. Demma:
By letter dated January 12, 2009 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML090160204), the Electric Power Research Institute (EPRI) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review, TR [Topical Report]
Materials Reliability Program (MRP) Report 1016596 (MRP-227), Revision 0, Pressurized Water Reactor (PWR) Internals Inspection and Evaluation Guidelines. By letter dated December 16, 2011, the NRC staff issued its safety evaluation (SE) on MRP-227, Revision 0. A copy of the NRC staff transmittal letter and SE can be found in ADAMS Accession No. ML11308A770.
The SEs on MRP-227 contained a number of applicant/licensee action items (A/LAIs). Two of these, A/LAI 1 and A/LAI 7, have been under staff review to determine if they can be closed on a generic basis instead of in plant-specific evaluations. Based on its review of the information submitted by EPRI, the NRC staff finds the information submitted to address A/LAI 1 and A/LA 7 on a generic-basis acceptable subject to the limitations specified in the EPRI submissions and in the NRC staff SE. Enclosed for EPRI review and comment is the NRC staff draft SE.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR 2.390), we have determined that the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for EPRI to comment on any proprietary information, factual errors, or clarity concerns contained in the draft SE.
NOTICE: Enclosure transmitted herewith contains SUNSI. When separated from Enclosure, this transmittal document is decontrolled.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
OFFICIAL USE ONLY - PROPRIETARY INFORMATION B. Burgos The final SE will be issued after making any necessary changes and will be made publicly available. The NRC staff disposition of your comments on the draft SE will be discussed in the final SE.
To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact the Project Manager for the review, Joseph J. Holonich at 301-415-7297 or Joseph.Holonich@nrc.gov.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 99902021
Enclosure:
Draft SE OFFICIAL USE ONLY - PROPRIETARY INFORMATION
ML16238A128 (Package); ML16238A133 (Letter/Public);
ML16238A134 (Draft SE/Non-Public); *concurrence via e-mail NRR-106 OFFICE DLP/PLPB/PM DLP/PLPB/LA* DE/DMLR/MVIB* DLP/PLPB/BC NAME JHolonich DHarrison SRuffin DMorey DATE 11/8/2017 12/14/2017 12/14/2017 1/3/2018