ML16176A177

From kanterella
Jump to navigation Jump to search
University of Utah, Response to Generic Letter 2016-01: Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools
ML16176A177
Person / Time
Site: University of Utah
(R-126)
Issue date: 06/13/2016
From: Schow R
Univ of Utah
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-16-001
Download: ML16176A177 (1)


Text

THEU UNIVERSITY OF UTAH Utah Nuclear ~ngineering Program 50 S. Central Campus Drive, Suite 2298 Salt Lake City, Utah 84112 801-581-4188 Fax 801-585-5477 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 June 13, 2016

SUBJECT:

RESPONSE TO GENERIC LETTER 2016-01: MONITORING OF NEUTRON-ABSORBING MATERIALS IN SPENT FUEL POOLS License No. R-126 Docket No. 50-407 This letter is submitted to fulfill the 210-day response requirement to Generic Letter 2016-01: Monitoring of Neutron-Absorbing Materials in Spent Fuels dated April 7, 2016 for the University of Utah.

Non-Power'Reactors - Question 1:

Are neutron-absorbing materials used in a reactor pool, fuel storage pool, or other wet locations designed for the storage of reactor or spent fl.lei?

Response 1:

The University of Utah TRIGA Reactor does not use any neutron-absorbing materials in the reactor pool, fuel storage pools, or any other wet locatio.ns for the storage of fuel.

Such materials are also not credited in our Safety Analysis Report.

Questions 2 and 3 are not applicable.

Sincerely, Ryan C. Schow Reactor Supervisor SOS Central Campus Drive, Room 1206 801-581-4188 rvan.c.schow@utah.edu cc: Xiaosong Yin, USN RC Craig Bassett, USNRC