Fisher Information Notice, (FIN) 2016-05 - Insufficient Valve Cage Hardfacing
ML16174A395
Person / Time
Site: Summer, Vogtle  
Issue date: 06/21/2016
From: Baitinger G
Fisher Controls International
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
FIN 2016-05
Download: ML16174A395 (5)


Text

EMERSON' Process Management June 21, 2016 To Whom It May Concern:

Attached is a Fisher Information Notice, (FIN) 2016-05 Fisher Controls International LLC 301 South First Ave.

P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Emerson Process Management - Fisher Valves complies with the reporting requirements of 10 CFR Part 21 Section 21.21 (b) and 10 CFR Part 50.55 (e) by informing the U.S. Nuclear Regulatory Commission Licensees or Purchaser of deviations or failures to comply.

Please review the attached FIN notice for applicability to your facility.

George Baitinger Director, Quality Americas Attachments (FISHER)

~

§

~

EMERSON..

Process Management Fisher Information Notice: FIN 2016-05 20 June 2016

Subject:

Insufficient Valve Cage Hardfacing Equipment Affected by this Fisher Information Notice:

Fisher Controls International LLC 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Items subject to this Fisher Information Notice (FIN) are confined to the equipment and orders referred to in Table 1 attached below ("Equipment"). Specifically, "Equipment" refers to the 8" sized hardfaced HPNS cages supplied per the order numbers listed in Table 1.

Purpose:

The purpose of this FIN is to alert affected customers that, as of 29 April 2016, Fisher Controls International LLC (Fisher) became aware of a situation which !)lay affect the performance of the aforementioned Equipment, including its safety-related function.

Fisher is informing affected customers of this circumstance in accordance with Section 21.21 (b) of10CFR21.

Applicability:

This FIN applies only to the Equipment identified in Table 1, which lists serial and order numbers of the Equipment that was delivered to affected customers.

Discussion:

The Equipment in question is subject to CoCr-A hardface overlay requirements. The CoCr-A overlay deposit thickness must be 0.060" minimum after machining. However, the cages supplied in fulfilment of the orders listed in Table 1 may have insufficient hardfacing depth on the inside bore diameter at the top of the cages (approximately 1.50" from top).

This issue first came to Fisher's attention when a material grade inspection revealed insufficient cobalt. Subsequent PMI testing confirmed the upper section at the top of the cage fell short of expected CoCr-A. Two in-stock cages were sent to a third party accredited laboratory for macroetch examination and hardness survey. The results of this survey confirmed the top of the cages did not meet the minimum hardness requirement of 34 HRC and further confirmed the insufficiency is limited to the uppermost 1.50" of the inside bore diameter of the cages.

~

~

~

EMERSON..

Process Management Fisher Controls International LLC 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 The absence of hardfacing at the mating surface between cage and plug creates the potential for galling, which could prevent the valve from performing its intended safety function. Testing has been conducted to analyze the risk of galling. Typically, galling is observed in cycle tests well exceeding the 600 cycle recommended lifetime for the Equipment. However, testing has proven galling to be an unpredictable phenomenon and could occur prior to the recommended lifetime of the Equipment. There are no known field issues with the affected Equipment.

Extent of Condition:

The problem of post-hardfacing material shrinkage is associated with the ratio of bore diameter to cage wall thickness. Large bore diameter thin-walled cages are at greater risk for material shrinkage. A third party accredited laboratory performed additional macroetch supplemental tests and evaluations on similar cages of varying bore sizes. It was determined that this issue is unique to the 8" sized HPNS cages.

Action Required:

Fisher will provide the affected customers with a properly coated cages at Fisher's cost. In addition, a Corrective Action Request (CAR 1804) has been initiated by Fisher to prevent reoccurrence of this issue.

~

~

~

EMERSON..

Process Management 10 CFR 21 Implications:

Fisher Controls International LLC 301 South First Ave P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Fisher requests that the recipient of this FIN review it and take appropriate action in accordance with 10 CFR 21. If there are any technical questions or concerns, please contact:

Ben Ahrens Quality Manager Emerson Process Management Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Phone: (641) 754-2249 Benjamin.ahrens@emerson.com f11j YI!( l.}

Chad Engle Nuclear Business Unit Director Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Fax: (641) 754-2854

Table 1 Affected Equipment and Orders

~~:

_ LB_P~rd~r# :~~I cus~Lm~,

19073487 San men 004 -X012140579 25 4500280610 25 19073491 Haiyang 004 -X012140579 46 4500280610 46 19073488 San men 004 -X012140579 25A 4500280610 25 19073489 San men 004 -X012140579 258 4500280610 25 19073490 San men 004 -X012140579 25C 4500280610 25 19073492 Haiyang 004 -X012140579 46A 4500280610 46 19073493 Haiyang 004-X012140579 468 4500280610 46 19073494 Haiyang 004-X012140579 46C 4500280610 46 19089916 Vogtle 004 -X012149977 43A 4500327665 43 19089915 Vogtle 004 -X012149977 43 4500327665 43 19089914 Vogtle 004 -X012149977 24A 4500327665 24 19089913 Vogtle 004 -X012149977 24 4500327665 24 19089912 Vogtle 004 -X012149977 42A 4500327665 42 19089911 Vogtle 004 -X012149977 42 4500327665 42 19089910 Vogtle 004 -X012149977 5A 4500327665 5

19089909 Vogtle 004 -XO 12149977 5

.4500327665 5

21294100 Summer 004 -X012149761

. 1A 4500327852 1

19089851 Summer 004 -X012149761 42A 4500327852 42 19089850 Summer 004 -X012149761 42 4500327852 42 19089849 Summer 004-X012149761 20A 4500327852 20 19089848 Summer 004 -X012149761

  • 20 4500327852 20 19089847 Summer 004-X012149761 40A 4500327852 40 19089846 Summer 004 -X012149761 40 4500327852 40 19089844 Summer 004 -X012149761 1

4500327852 1

19720772 Haiyang 860 -PV14HYG2 50 SEH210POVA051 F-ORG 5

19720771 Haiyang 860 -PV14HYG2 5C SEH210POVA051 F-ORG 5

19720770 Haiyang 860 -PV14HYG2 58 SEH210POVA051 F-ORG 5

19720769 Haiyang 860 -PV14HYG2 5A SEH210POVA051 F-ORG 5

19794752 San men 860 -PV14SAN2 50 SES21 OPOVA050F-ORG 5

19794751 San men 860 -PV14SAN2 5C SES21 OPOVA050F-ORG 5

19794750 San men 860 -PV14SAN2 58 SES210POVA050F-ORG 5

19794749 San men 860 -PV14SAN2 5A SES21 OPOVA050F-ORG 5