ML16169A012

From kanterella
Jump to navigation Jump to search
Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks
ML16169A012
Person / Time
Site: 07201027, Peach Bottom  
(DPR-044, DPR-056)
Issue date: 06/17/2016
From: Pat Navin
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
Download: ML16169A012 (1)


Text

Exelon Generation June 17, 2016 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277. 50-278. and 72-29 10 CFR 72.212

Subject:

Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks In accordance with 10 CFR 72.212(b)(2), the purpose of this letter is to register ISFSI casks that were recently placed into service.

The following information is provided in accordance with 10 CFR 72.212(b)(2).

Licensee Name:

Licensee Address:

Reactor License Numbers:

Reactor Docket Numbers:

ISFSI Docket Number:

Contact Person and

Title:

Cask ID#

Cask Model#

TN-68-76-D TN-68 TN-68-89-E TN-68 Exelon Generation Company, LLC Peach Bottom Atomic Power Station 1848 Lay Road, Delta, PA 17314 (Renewed) DPR-44 and DPR-56 50-277 and 50-278 72-29 D. J. Foss, Sr. Regulatory Engineer Cask Certificate #

72-1027, Amendment 1 72-1027, Amendment 1 If you have any questions, please contact D. J. Foss at 717-456-4311.

Patrick D. Navin Plant Manager Peach Bottom Atomic Power Station CCN: 16-46 cc:

NRC Regional Administrator - Region I NRG Senior Resident Inspector - Peach Bottom Atomic Power Station In-Service Date 5/27/16 6/13/16