ML16162A671

From kanterella
Jump to navigation Jump to search

North Carolina State University - Response Submittal 3 to the Request for Additional Information for Technical Specification Amendment 19 - Use of 6 Percent Enriched Fuel
ML16162A671
Person / Time
Site: North Carolina State University
Issue date: 06/10/2016
From: Hawari A
North Carolina State University
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML16162A671 (2)


Text



&ROOHJHRI(QJLQHHULQJ

'HSDUWPHQWRU1XFOHDU(QJLQHHULQJ

1XFOHDU5HDFWRU3URJUDP

ZZZQHQFVXHGXQUS

&DPSXV%R[

6WLQVRQ'ULYH

5DOHLJK1&

3

-XQH





U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC SUBJECT RESPONSE SUBMITTAL 3 TO THE REQUEST FOR ADDITIONAL INFORMATION FOR TECHINCAL SPECIFICATION AMENDMENT 19 - USE OF 6% ENRICHED FUEL License No. R-120 Docket No. 50-297 Please find enclosed submittal 3 to the Request for Additional Information for the License Amendment Request related to the use of six percent enriched fuel (TAC NO. MF6088).

This submittal is an update to Table 3.2 found in Examination of Mixed Enrichment Core Loading for the NCSU PULSTAR Reactor, Appendix A to NC State University License Amendment for the Use of 6% Enriched Fuel. (ADAMS Accession No. ML15076A020)

If you have any questions regarding this amendment or require additional information, please contact Andrew Cook at (919) 515-4602 or atcook@ncsu.edu.

I declare under penalty of perjury that the forgoing is true and correct. Executed on 10 June 2016.

Sincerely, Ayman I. Hawari, Ph.D.

Director, Nuclear Reactor Program North Carolina State University

Enclosures:

Submittal 3 - Response to Request for Additional Information





5(63216(725(48(67)25$,7,21$/,1)250$7,21

)25/,&(16($0(1'0(175(48(67)25

7+(86(2)6,;3(5&(17(15,&+(')8(/ 7$&120) 



68%0,77$/



1257+&$52/,1$67$7(81,9(56,7<

/,&(16(125'2&.(712

-XQH





&RUH  RI WKH 38/67$5 UHDFWRU ZDV UHDQDO\\]HG XVLQJ WKH VDPH DSSURDFK GHVFULEHG LQ WKH

GRFXPHQW³([DPLQDWLRQRI0L[HG(QULFKPHQW&RUH/RDGLQJIRUWKH1&6838/67$55HDFWRU

$SSHQGL[ $ WR 1& 6WDWH 8QLYHUVLW\\ /LFHQVH $PHQGPHQW IRU WKH 8VH RI  (QULFKHG )XHO

$'$06$FFHVVLRQ1R0/$ '$QXSGDWHG7DEOH RI$SSHQGL[$ LVSUHVHQWHG

EHORZVKRZLQJWKHUHVXOWVRIWKHUHDQDO\\VLV7KHXSGDWHGFRUHLQIRUPDWLRQLQWKHWDEOHDUH

KLJKOLJKWHG7KHPRVWUHFHQWO\\DYDLODEOHPHDVXUHGGDWDDUHFRPSDUHGWRWKHFDOFXODWHG 0&13 

GDWDFRUUHVSRQGLQJWRDVLPLODUEXUQXSVWDWHRIFRUHDQGWRDIORRGHGEHDPSRUW7KHRXWFRPH

RIFRUHUHDQDO\\VLVVKRZVWKDWWKHGHYLDWLRQVEHWZHHQPHDVXUHPHQWVDQGFDOFXODWLRQVDUHZLWKLQ

DQGDUHFRQVLVWHQWZLWKGHYLDWLRQVREVHUYHGIRUSUHYLRXVFRUHV,QSDUWLFXODUWKHFDOFXODWHG

6'0LVZLWKLQRIWKHPHDVXUHGYDOXH





7DEOH  6XPPDU\\ RI SDUDPHWHUV IRU KLVWRULF FRUH FRQILJXUDWLRQV )RU HDFK FRUH WKH ULJKW FROXPQ LV

WKH0&13YDOXHDQGWKHOHIWFROXPQLVWKHPHDVXUHGYDOXH )RUWKHVWDQGDUGFRUHWKHFRPSDULVRQLVPDGH

EDVHGRQSLQSRZHUSHDNLQJIDFWRUVDVWKHPHDVXUHPHQWLVPRUHUHSUHVHQWDWLYHRIWKLVSDUDPHWHU



6WDQGDUG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

5HIOHFWHG

&RUH

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

0HDV

&DOF

6

SFP 

































6

SFP 

































5HJ

SFP 

































6KLP

SFP 

































  • DQJ

SFP 

    























6'0

SFP 

               

)4 $