1 IPRenewal NPEmails From:
Dolansky, Robert J <RDolans@entergy.com>
Sent:
Friday, April 29, 2016 9:58 AM To:
Floyd, Niklas
Subject:
[External_Sender] FW: Extra screen shots for Baffle Bolts Attachments:
Screen Shots IPP BFB UT.docx From: Goodman, Matthew A [1]
Sent: Thursday, April 28, 2016 3:31 PM To: Allen, Robert E; Dolansky, Robert J
Subject:
RE: Extra screen shots for Baffle Bolts Attached is the document Pat pulled together, showing the screen shots of the bolts you requested. The left side is the calibration bolt to help compare to the results on the right hand side.
Let me know if you need anything else.
- Regards, Matt From: Allen, Robert E [2]
Sent: Thursday, April 28, 2016 1:36 PM To: Goodman, Matthew A; Dolansky, Robert J
Subject:
RE: Extra screen shots for Baffle Bolts
- Matt, The bolt & plate number listed below are correct.
Thanks for your support, Bob A.
From: Goodman, Matthew A [3]
Sent: Thursday, April 28, 2016 12:46 PM To: Dolansky, Robert J; Allen, Robert E
Subject:
Extra screen shots for Baffle Bolts
- Bob, I will get Pat working on the screen shots of all 10 channels for the following bolts.
Bolt #
Plate #
E-29 8R E-68 20 A-12 4
E-71 21 E-2 1R
2
- Regards, Matt Goodman Project Manager Office: (724) 722-6037 Mobile: (724) 689-6596 Fax: (724) 722-5830 This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).
This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).
Hearing Identifier:
IndianPointUnits2and3NonPublic_EX Email Number:
5864 Mail Envelope Properties (ECCFBB6589456C4185C63115574A08796B388351)
Subject:
[External_Sender] FW: Extra screen shots for Baffle Bolts Sent Date:
4/29/2016 9:57:42 AM Received Date:
4/29/2016 9:58:24 AM From:
Dolansky, Robert J Created By:
RDolans@entergy.com Recipients:
"Floyd, Niklas" <Niklas.Floyd@nrc.gov>
Tracking Status: None Post Office:
jdcxmetsp004.etrsouth.corp.entergy.com Files Size Date & Time MESSAGE 2481 4/29/2016 9:58:24 AM image001.jpg 4250 Screen Shots IPP BFB UT.docx 3384916 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
BOLT A-012, CHANNELS 1-3 Calibration Bolt NN1 Bolt A-012
BOLT A-012, CHANNELS 4-6 Calibration Bolt NN1 Bolt A-012
BOLT A-012, CHANNELS 7-10 Calibration Bolt NN1 Bolt A-012
BOLT E-002, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-002
BOLT E-002, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-002
BOLT E-002, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-002
BOLT E-29, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-029
BOLT E-029, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-029
BOLT E-029, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-029
BOLT E-068, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-068
BOLT E-068, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-068
BOLT E-068, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-068
BOLT E-071, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-071
BOLT E-071, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-071
BOLT E-071, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-071
1 IPRenewal NPEmails From:
Dolansky, Robert J <RDolans@entergy.com>
Sent:
Friday, April 29, 2016 9:58 AM To:
Floyd, Niklas
Subject:
[External_Sender] FW: Extra screen shots for Baffle Bolts Attachments:
Screen Shots IPP BFB UT.docx From: Goodman, Matthew A [4]
Sent: Thursday, April 28, 2016 3:31 PM To: Allen, Robert E; Dolansky, Robert J
Subject:
RE: Extra screen shots for Baffle Bolts Attached is the document Pat pulled together, showing the screen shots of the bolts you requested. The left side is the calibration bolt to help compare to the results on the right hand side.
Let me know if you need anything else.
- Regards, Matt From: Allen, Robert E [5]
Sent: Thursday, April 28, 2016 1:36 PM To: Goodman, Matthew A; Dolansky, Robert J
Subject:
RE: Extra screen shots for Baffle Bolts
- Matt, The bolt & plate number listed below are correct.
Thanks for your support, Bob A.
From: Goodman, Matthew A [6]
Sent: Thursday, April 28, 2016 12:46 PM To: Dolansky, Robert J; Allen, Robert E
Subject:
Extra screen shots for Baffle Bolts
- Bob, I will get Pat working on the screen shots of all 10 channels for the following bolts.
Bolt #
Plate #
E-29 8R E-68 20 A-12 4
E-71 21 E-2 1R
2
- Regards, Matt Goodman Project Manager Office: (724) 722-6037 Mobile: (724) 689-6596 Fax: (724) 722-5830 This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).
This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).
Hearing Identifier:
IndianPointUnits2and3NonPublic_EX Email Number:
5864 Mail Envelope Properties (ECCFBB6589456C4185C63115574A08796B388351)
Subject:
[External_Sender] FW: Extra screen shots for Baffle Bolts Sent Date:
4/29/2016 9:57:42 AM Received Date:
4/29/2016 9:58:24 AM From:
Dolansky, Robert J Created By:
RDolans@entergy.com Recipients:
"Floyd, Niklas" <Niklas.Floyd@nrc.gov>
Tracking Status: None Post Office:
jdcxmetsp004.etrsouth.corp.entergy.com Files Size Date & Time MESSAGE 2481 4/29/2016 9:58:24 AM image001.jpg 4250 Screen Shots IPP BFB UT.docx 3384916 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
BOLT A-012, CHANNELS 1-3 Calibration Bolt NN1 Bolt A-012
BOLT A-012, CHANNELS 4-6 Calibration Bolt NN1 Bolt A-012
BOLT A-012, CHANNELS 7-10 Calibration Bolt NN1 Bolt A-012
BOLT E-002, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-002
BOLT E-002, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-002
BOLT E-002, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-002
BOLT E-29, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-029
BOLT E-029, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-029
BOLT E-029, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-029
BOLT E-068, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-068
BOLT E-068, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-068
BOLT E-068, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-068
BOLT E-071, CHANNELS 1-3 Calibration Bolt NN1 Bolt E-071
BOLT E-071, CHANNELS 4-6 Calibration Bolt NN1 Bolt E-071
BOLT E-071, CHANNELS 7-10 Calibration Bolt NN1 Bolt E-071