NEXTeraM ENERGY~
DUANE ARNOLD April 11, 2016 NG-16-00B1 U.S. Nuclear Regulatory Commission A TIN: Document Control Desk Washington, DC 20555 Duane Arnold Energy Center Docket No. 50-331 Renewed Op. License No. DPR-49 Monitoring Well MW-OBA Tritium 30 Day Special Report
Reference:
- 1. Offsite Dose Assessment Manual, Revision 35, Section 6.3.2, "Radiological Environmental Monitoring Program" This report is being provided in accordance with Section 6.3.2 of the Duane Arnold Energy Center Offsite Dose Assessment Manual (ODAM) (Reference 1), due to exceedance of a limit defined in ODAM Section 6.3.2. Specifically, routine tritium analysis performed over the first calendar quarter of 2016 exceeded the limits of ODAM Table 6.3-3. ODAM Table 6.3-3 reporting level for tritium is 20,000 pCi/L. The tritium concentration for monitoring well location MW-OBA, averaged over the first quarter of 2016, was 39,700 pCi/L.
MW-OBA is located within the site's Protected Area and is a sentinel well for the condensate pump pit and turbine building sump. Analysis of onsite drinking water found tritium levels below the lower limit of detection (LLD), and the tritium plume is located entirely within the site's Protected Area. No other non-natural radionuclides were detected by gamma scan at MW-OBA Therefore, there is no risk to the public or water levels.
NextEra has retained the services of an independent expert vendor to obtain and analyze additional samples to further characterize the ground water tritium in order to assist in determining its source.
If you have any questions please contact Mr. Mike Davis, Licensing Manager, at 319-851-7032,~
T.A.Vehec Vice President, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC cc:
Administrator, Region Ill, USNRC Project Manager, DAEC, USNRC Resident Inspector, DAEC, USNRC NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324
NEXTeraM ENERGY~
DUANE ARNOLD April 11, 2016 NG-16-00B1 U.S. Nuclear Regulatory Commission A TIN: Document Control Desk Washington, DC 20555 Duane Arnold Energy Center Docket No. 50-331 Renewed Op. License No. DPR-49 Monitoring Well MW-OBA Tritium 30 Day Special Report
Reference:
- 1. Offsite Dose Assessment Manual, Revision 35, Section 6.3.2, "Radiological Environmental Monitoring Program" This report is being provided in accordance with Section 6.3.2 of the Duane Arnold Energy Center Offsite Dose Assessment Manual (ODAM) (Reference 1), due to exceedance of a limit defined in ODAM Section 6.3.2. Specifically, routine tritium analysis performed over the first calendar quarter of 2016 exceeded the limits of ODAM Table 6.3-3. ODAM Table 6.3-3 reporting level for tritium is 20,000 pCi/L. The tritium concentration for monitoring well location MW-OBA, averaged over the first quarter of 2016, was 39,700 pCi/L.
MW-OBA is located within the site's Protected Area and is a sentinel well for the condensate pump pit and turbine building sump. Analysis of onsite drinking water found tritium levels below the lower limit of detection (LLD), and the tritium plume is located entirely within the site's Protected Area. No other non-natural radionuclides were detected by gamma scan at MW-OBA Therefore, there is no risk to the public or water levels.
NextEra has retained the services of an independent expert vendor to obtain and analyze additional samples to further characterize the ground water tritium in order to assist in determining its source.
If you have any questions please contact Mr. Mike Davis, Licensing Manager, at 319-851-7032,~
T.A.Vehec Vice President, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC cc:
Administrator, Region Ill, USNRC Project Manager, DAEC, USNRC Resident Inspector, DAEC, USNRC NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324