91120, Rev. 0, University of Maryland Reactor Analysis and Support - Support Calculations for Mutrs Maximum Inlet Temperature
ML16061A004
Person / Time
Site: University of Maryland
(R-070)
Issue date: 08/01/2011
From: Crozier J
General Atomics, Univ of Maryland - College Park
To:
Office of Nuclear Reactor Regulation, US Dept of Energy (DOE)
References
00096970, 39364 91120, Rev 0
Download: ML16061A004 (13)


Text

,

%I(

ISSUED RCMAPvd 2011/08101 911206 Revision 0 UNIVERSITY OF MARYLAND REACTOR ANALYSIS AND SUPPORT Support Calculations for MUTR's Maximum Inlet Ternperatu re Prepared by:

Address:

TRIGA Reactor Division of General Atom ics P0 Box 85608 San Diego, CA 92186-5608 Prepared under Contract No. 00096970 for the U.S. Department of Energy GA PROJECT 39364

+GENERAL ATOMilCS

+GENERAL ATOMI~CS GA 14385 (REV. 08106E)

ISSUE/RELEASE

SUMMARY

[] R & D APPVL DISC QA LEVEL SYS DOC. TYPE PROJECT DOCUMENT :NO.

'REV

[] DV&S LEVEL

]

TNE 2

N lB D CR 39364 911206 C)

TITLE:'

Support Calculations for MUJTR's Maximum Inlet Temperature APPROVAL(S)

REVISION CM APPROVAL!

PREPARED DESCRIPTIONI DATE,,

REV BY ENGINEERING

___A__

PROJECT W.O. NO.

7 S U D0 J. Crozier J. Bolirn K. Partain Initial Issue

(

1 01A39364

-0410 CONTINUE ON GA FORM 1435-1 NEXT INDENTURED COMPUTER PROGRAM PIN(S)

El GA PROPRIETARY INFORMATION THIS DOCUMENT IS THE PROPERTY OF GENERAL ATOMICS. ANY TRANSMITTAL OF THIS DOCUMENT OUTSIDE GA WILL BE IN CONFIDENCE. EXCEPT WITH THE WRITTEN CONSENT OF GA, (1) THIS DOCUMENT MAY NOT BE COPIED IN WHOLE OR IN PART AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT AND (2) INFORMATION CONTAINED HEREIN MAY NOT BE COMMUNICATED TO OTHERS AND MAY BE USED BY RECIPIENT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITrED.

[]

NO GA PROPRIETARY INFORMATION PAGE ii OF 14

Support Calculations for M UTR's Maximum Inlet Temperature 911206/0 TABLE OF CONTENTS AC RONYMS/ABBREVIATIONS.......................................................................

i I

PURPOSE.........................................................................................

2 METHODS - RELAP5/IMOD3.3-Patch03 CODE.........................................

I...

3 RESULTS -RELAP5.........................................................................I..

4 CONCLUSIONS................................................................................. 3 5

REFERENCES.................................................................................. 4 6

INDEPENDENT REVIEW...................................................................... 4 APPENDIX A - INDEPENDENT REVIEW REPORT............................................... A-I APPENDIX B - CALCULATION FILE LISTINGS.................................................. B-I LIST OF FIGURES' Figure 3-1 RELAP Natural Convection (No Primary Coolant Flow) Block Diagram............... 2 Figure 3-2: MUTR DNBR as a Function of Pool Inlet Temperature.................................. 3 iii

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 ACRONYMSIABB REVIATIONS Acronym/Abbreviation Description DNBR Departure from Nucleate Boiling Ratio GA General Atom ics MUTR University of Maryland TRIGA Reactor PRNC Puerto Rico TRIGA reactor RAI Request for Additional Information SAR Safety Analysis Report TAMU Texas A&M University TRIGA Training Research Isotope General Atomics iii

Support Calculations for MUTR's Maximum Inlet Temperature9110/

911206/0 I

PURPOSE The purpose of this calculation file is to document the thermal hydraulic analyses that were performed by General Atomics (GA) in support of the activities necessary to answer the University of Maryland TRIGA Reactor (MUTR) Safety Analysis Report (SAR) submittal Request for Additional Information (RAI) question regarding the maximum inlet temperature. The nuclear analyses used in these analyses are reported in "Support Calculations for MUTR's Request for Additional Information" (Ref. 1).

Additional explanation and calculations were requested for the question: "For a DNBR of 2.0, what is the inlet (bulk fluid) temperature under natural circulation conditions? This temperature would be used as the Lim iting Condition for Operation.'

2 METHODS - RELAP5/IMOD3.3-PATGHO3 CODE RELAP has been an industry standard code for the analysis of power reactors. Its development and improvements have occurred over at least 25 years. The code performs steady state and transient reactor neutronics, thermal hydraulics and fuel rod thermal analysis. It allows for very general modeling - multiple rod and channel configurations and heat structures for rod thermal performance. The code has sophisticated single and two phase flow modeling both in its continuity, momentum and energy formulations, as well as for wall and interfacial friction and heat transfer correlations.

The version RELAP5/MOD3.3-Patch03 is the latest available validated version of the code (Ref. 2) (Ref.3).

3 RESULTS -RELAP5 The latest version of the RELAP Code (RELAP5/MOD3.3-Patch03) was used to evaluate the MUTR thermal/hydraulic performance for this RAI.

The RELAP model for this request contains an average powered rod representing the entire core and a hot rod representing the maximum powered rod. The MUTR TRIGA reactor uses four rod fuel element clusters as used in the Neutron Radiography Facility at Idaho National Laboratory (Ref. 4), Puerto Rico Nuclear Center (PRNC) (Ref. 5), and Texas A&M University (TAMU) TRIGA reactors (Ref. 6). As such, the RELAP modeling of the average and hot rods used in the RELAP model for these previous HEU-to-LEU conversions is used for the MUTR RELAP model, see Figure 3-1.

I

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 Relucnr, tnw Irrnln, top tmrnk tocoyc inltt for rJvcnnna*

cinayrort Som o te mprtat oniton i bthe UrnRLA mol~de13l incude o rdpoel.ato akna 1.597.or FiDparure f-1rom Nulatera BoilngvRation (DNBr)icalyCuolante using Bernat corgreatin (Ref. 7)

Natural circulation core cooling.

Tank diameter - 7 ft., water depth from surface to reactor top - 17.1 ft.

14.7 psia pressure above tank water.

2

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 Using these conditions, a RELAP run was performed at,a reactor power of 600 kW for various pool temperatures.

The RELAP results were used to construct a plot of pool temperature versus DNBR, Figure 3-2. The plot shows that the inlet pool temperature can reach 92 00 and only yield a DNBR of 2.96, at 600 kW. This is approximately equal to a DNBR of 5.92 for a reactor power level of 300 kW. At a pool inlet temperature of 95 00, the RELAP5 code fails to generate a stable solution due to the large vapor volume. The results demonstrate significant vapor formation. Additionally, the hot channel flow rate, quality, and bulk temperature vary irregularly along the flow channel.

This RELAP5 behavior may be indicative of parametric fluctuations in the actual core at this power level and pool inlet temperature.

Based on the RELAP model, the maximum theoretical achievable inlet temperature of the MUTR reactor would be 92 00, at which point DNB would be predicted to occur. Associated RELAP run files and MathCad calculations are listed in Appendix B and included in a local subdirectory.

DNBR vs Pool Temp - 600 kW 6.0 5.5 5.0 4.5 4.0

  • 3.5 3.0 2.5 2.0 1.5 1.0 40 45 50 55 60 65 70 75 80 85 90 95 Pool Temp, °C Figure 3-2: MUTR DNBR as a Function of Pool Inlet Temperature 4

CONCLUSIONS The analyses herein demonstrates that the MUTR TRIGA reactor reaches a DNBR of 2.96 when operating at a maximum pool inlet temperature of 92 00 and a power level of 600 kW.

Hence, for normal operations at a power level of 300 kW and a maximum pool inlet temperature 3

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 of 92 00, the DNBR is greater than 2.0. Based on the data from Figure 3-2, with a maximum pool inlet temperature of 92 °C, a DNBR of 2.0 could not occur.

5 REFERENCES

1.

Ellis, C. "Support Calculations for MUTR's Request for Additional Information," GA 911199, December 2010.

2.

"RELAP5/MOD3.3 Code Manual Volume 3: Developmental Assessment Problems,'

NUREG-CR-5535/Rev. P3 - Volume IIl, 2006.

3.

Tuey, J. "RELAP5/MOD 3.3 Code Verification Report," General Atomics, 09490R00001, Rev. A, July 2011

4.

Crozier, J. and Ellis, C., "LEU Upgrade of the NRAD Reactor Final Report," GA Document No. 911193 Revi sion 0, February 2011

5.

Safeguards Summary Report for the TRIGA Reactor at the Puerto Rico Nuclear Center, Mayaquez, Puerto Rico, PRNC 123, April 1969.

6.

"Safety and Accident Analyses Report Texas A&M University (TAM U) Conversion from HEU to LEU Fuel," Texas A&M University, Docket 50-1 28, December 2005.

7.

Bernath, L.B., "A Theory of Local Boiling Burnout and Its Application to Existing Data",

Chem. Eng. Progress Symposium Series No. 30, Vol. 56, pp 95-116., 1960 6

INDEPENDENT REVIEW John Bolin -

Review results (Thermal Hydraulics):

No comments on the thermal hydraulic analyses.

4

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 APPENDIX A - INDEPENDENT REVlIEW REPORT A-i

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 CALCULATION REVIEW REPORT TITLE DOCUMENT NUMBER REV Suppori Colculallono for MUTR's Maxirnum Inlet Tcmporuhurn 911200 0

INDEPENDENT REVIEWER:

NAIME:

John Bolin ORGANIZATION:

480 MODULAR HELIUM REACTOR MANAGER:

Tony Veca NAMEIATR REVIEW CRITERIA YES NO COMMENT REVIEW CALCULATION METHOD 0]

COMPARE CALCULATION METHOD WITH SIMILAR APPROVED METHOD 0-'

0 PREPARE ALTERNATE CALCULATION USING DIFFERENT METHOD 0]

[]

REVIEW ASSUMPTIONS:

  • UNIQUELY IDENTIFIED 0]

- ADEQUATELY DESCRIBED 0]

0

- REASONABLE, 0]

0

- UNCONFIRMED SPECIFICALLY IDENTIFIED 0]

0 REV1EW INPUTS 0*

0]

REVIEW RESULTSJCONCLUSIONS 0]

0 VERIFY COMPUTER CODE INFORMATION coRRECT

]

[

VERIFY GUALITY ASSURANCE LEVEL 0]

0

[]

D RECORD OR ATTACH 0] LIST OF DOCUMENTS USED IN REVIEW lAND/OR) 0] ALTERNATE CALCULATIONS OTHER REMARKS:

SCALCULATION FOUND TO BE VALID AND CONCLUSIONS TO BE CORRECT (OR) 0 EXCEPT AS NOTED ABOVE.

IN*DEPENDENT REVIEWER

/~G]'

'**DATE 7/

/`

FINAL REVIEW BEFORE ISSUEJRELEASE:

INDEPENDNT REVIWER

(

IGNATURE

~DT A-2

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 APPENDIX B - CALCULATION FILE LISTINGS B-1

Support Calculations for MUTR's Maximum Inlet Temperature Calculation files in support of Section 3.

911206/0 File Description File Type DVD Director Location MUT RLAPDNR npu fle RELAP5 input MUTR_dnbr 600kW_40C.inp 600kW, 40C___________________________

MUTR RELAP DNBR output file RELAP5 output MUTR_dnbr 600kW_40C.out 600kW, 40C MUT RLAPDNR npu fle RELAP5 input MUTR dnbr_600kW_80C.inp 600kW, 80C______________

MUTR RELAP DNBR output file RELAP5 output MUTR dnbr_600kW_80C.out 600kW, 80C MUT RLAPDNR npu fle RELAP5 input MUTR dnbr_600kW_90C.inp 600kW, 90C MUTR RELAP DNBR output file RELAP5 output MUTR_dnbr_600kW_90C.out 600kW, 90C MUT RLAPDNR npu fle RELAP5 input MUTR_dnbr_600kW_92C.inp 600kW, 92C_

MUTR RELAP DNBR output file RELAP5 output MUTR dnbr_600kW_92C.out 600kW, 92C____________________________

MUTR MathCAD file MathCAD Bernath dnbr.rncd B-2

+GENERAL ATOMVICS P.O0 BOX 85608 SAN DIEGO, GA 92186-5608 (858) 455-3000

%I(

ISSUED RCMAPvd 2011/08101 911206 Revision 0 UNIVERSITY OF MARYLAND REACTOR ANALYSIS AND SUPPORT Support Calculations for MUTR's Maximum Inlet Ternperatu re Prepared by:

Address:

TRIGA Reactor Division of General Atom ics P0 Box 85608 San Diego, CA 92186-5608 Prepared under Contract No. 00096970 for the U.S. Department of Energy GA PROJECT 39364

+GENERAL ATOMilCS

+GENERAL ATOMI~CS GA 14385 (REV. 08106E)

ISSUE/RELEASE

SUMMARY

[] R & D APPVL DISC QA LEVEL SYS DOC. TYPE PROJECT DOCUMENT :NO.

'REV

[] DV&S LEVEL

]

TNE 2

N lB D CR 39364 911206 C)

TITLE:'

Support Calculations for MUJTR's Maximum Inlet Temperature APPROVAL(S)

REVISION CM APPROVAL!

PREPARED DESCRIPTIONI DATE,,

REV BY ENGINEERING

___A__

PROJECT W.O. NO.

7 S U D0 J. Crozier J. Bolirn K. Partain Initial Issue

(

1 01A39364

-0410 CONTINUE ON GA FORM 1435-1 NEXT INDENTURED COMPUTER PROGRAM PIN(S)

El GA PROPRIETARY INFORMATION THIS DOCUMENT IS THE PROPERTY OF GENERAL ATOMICS. ANY TRANSMITTAL OF THIS DOCUMENT OUTSIDE GA WILL BE IN CONFIDENCE. EXCEPT WITH THE WRITTEN CONSENT OF GA, (1) THIS DOCUMENT MAY NOT BE COPIED IN WHOLE OR IN PART AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT AND (2) INFORMATION CONTAINED HEREIN MAY NOT BE COMMUNICATED TO OTHERS AND MAY BE USED BY RECIPIENT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITrED.

[]

NO GA PROPRIETARY INFORMATION PAGE ii OF 14

Support Calculations for M UTR's Maximum Inlet Temperature 911206/0 TABLE OF CONTENTS AC RONYMS/ABBREVIATIONS.......................................................................

i I

PURPOSE.........................................................................................

2 METHODS - RELAP5/IMOD3.3-Patch03 CODE.........................................

I...

3 RESULTS -RELAP5.........................................................................I..

4 CONCLUSIONS................................................................................. 3 5

REFERENCES.................................................................................. 4 6

INDEPENDENT REVIEW...................................................................... 4 APPENDIX A - INDEPENDENT REVIEW REPORT............................................... A-I APPENDIX B - CALCULATION FILE LISTINGS.................................................. B-I LIST OF FIGURES' Figure 3-1 RELAP Natural Convection (No Primary Coolant Flow) Block Diagram............... 2 Figure 3-2: MUTR DNBR as a Function of Pool Inlet Temperature.................................. 3 iii

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 ACRONYMSIABB REVIATIONS Acronym/Abbreviation Description DNBR Departure from Nucleate Boiling Ratio GA General Atom ics MUTR University of Maryland TRIGA Reactor PRNC Puerto Rico TRIGA reactor RAI Request for Additional Information SAR Safety Analysis Report TAMU Texas A&M University TRIGA Training Research Isotope General Atomics iii

Support Calculations for MUTR's Maximum Inlet Temperature9110/

911206/0 I

PURPOSE The purpose of this calculation file is to document the thermal hydraulic analyses that were performed by General Atomics (GA) in support of the activities necessary to answer the University of Maryland TRIGA Reactor (MUTR) Safety Analysis Report (SAR) submittal Request for Additional Information (RAI) question regarding the maximum inlet temperature. The nuclear analyses used in these analyses are reported in "Support Calculations for MUTR's Request for Additional Information" (Ref. 1).

Additional explanation and calculations were requested for the question: "For a DNBR of 2.0, what is the inlet (bulk fluid) temperature under natural circulation conditions? This temperature would be used as the Lim iting Condition for Operation.'

2 METHODS - RELAP5/IMOD3.3-PATGHO3 CODE RELAP has been an industry standard code for the analysis of power reactors. Its development and improvements have occurred over at least 25 years. The code performs steady state and transient reactor neutronics, thermal hydraulics and fuel rod thermal analysis. It allows for very general modeling - multiple rod and channel configurations and heat structures for rod thermal performance. The code has sophisticated single and two phase flow modeling both in its continuity, momentum and energy formulations, as well as for wall and interfacial friction and heat transfer correlations.

The version RELAP5/MOD3.3-Patch03 is the latest available validated version of the code (Ref. 2) (Ref.3).

3 RESULTS -RELAP5 The latest version of the RELAP Code (RELAP5/MOD3.3-Patch03) was used to evaluate the MUTR thermal/hydraulic performance for this RAI.

The RELAP model for this request contains an average powered rod representing the entire core and a hot rod representing the maximum powered rod. The MUTR TRIGA reactor uses four rod fuel element clusters as used in the Neutron Radiography Facility at Idaho National Laboratory (Ref. 4), Puerto Rico Nuclear Center (PRNC) (Ref. 5), and Texas A&M University (TAMU) TRIGA reactors (Ref. 6). As such, the RELAP modeling of the average and hot rods used in the RELAP model for these previous HEU-to-LEU conversions is used for the MUTR RELAP model, see Figure 3-1.

I

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 Relucnr, tnw Irrnln, top tmrnk tocoyc inltt for rJvcnnna*

cinayrort Som o te mprtat oniton i bthe UrnRLA mol~de13l incude o rdpoel.ato akna 1.597.or FiDparure f-1rom Nulatera BoilngvRation (DNBr)icalyCuolante using Bernat corgreatin (Ref. 7)

Natural circulation core cooling.

Tank diameter - 7 ft., water depth from surface to reactor top - 17.1 ft.

14.7 psia pressure above tank water.

2

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 Using these conditions, a RELAP run was performed at,a reactor power of 600 kW for various pool temperatures.

The RELAP results were used to construct a plot of pool temperature versus DNBR, Figure 3-2. The plot shows that the inlet pool temperature can reach 92 00 and only yield a DNBR of 2.96, at 600 kW. This is approximately equal to a DNBR of 5.92 for a reactor power level of 300 kW. At a pool inlet temperature of 95 00, the RELAP5 code fails to generate a stable solution due to the large vapor volume. The results demonstrate significant vapor formation. Additionally, the hot channel flow rate, quality, and bulk temperature vary irregularly along the flow channel.

This RELAP5 behavior may be indicative of parametric fluctuations in the actual core at this power level and pool inlet temperature.

Based on the RELAP model, the maximum theoretical achievable inlet temperature of the MUTR reactor would be 92 00, at which point DNB would be predicted to occur. Associated RELAP run files and MathCad calculations are listed in Appendix B and included in a local subdirectory.

DNBR vs Pool Temp - 600 kW 6.0 5.5 5.0 4.5 4.0

  • 3.5 3.0 2.5 2.0 1.5 1.0 40 45 50 55 60 65 70 75 80 85 90 95 Pool Temp, °C Figure 3-2: MUTR DNBR as a Function of Pool Inlet Temperature 4

CONCLUSIONS The analyses herein demonstrates that the MUTR TRIGA reactor reaches a DNBR of 2.96 when operating at a maximum pool inlet temperature of 92 00 and a power level of 600 kW.

Hence, for normal operations at a power level of 300 kW and a maximum pool inlet temperature 3

Support Calculations for MUTR's Maximum Inlet Temperature 910/

911206/0 of 92 00, the DNBR is greater than 2.0. Based on the data from Figure 3-2, with a maximum pool inlet temperature of 92 °C, a DNBR of 2.0 could not occur.

5 REFERENCES

1.

Ellis, C. "Support Calculations for MUTR's Request for Additional Information," GA 911199, December 2010.

2.

"RELAP5/MOD3.3 Code Manual Volume 3: Developmental Assessment Problems,'

NUREG-CR-5535/Rev. P3 - Volume IIl, 2006.

3.

Tuey, J. "RELAP5/MOD 3.3 Code Verification Report," General Atomics, 09490R00001, Rev. A, July 2011

4.

Crozier, J. and Ellis, C., "LEU Upgrade of the NRAD Reactor Final Report," GA Document No. 911193 Revi sion 0, February 2011

5.

Safeguards Summary Report for the TRIGA Reactor at the Puerto Rico Nuclear Center, Mayaquez, Puerto Rico, PRNC 123, April 1969.

6.

"Safety and Accident Analyses Report Texas A&M University (TAM U) Conversion from HEU to LEU Fuel," Texas A&M University, Docket 50-1 28, December 2005.

7.

Bernath, L.B., "A Theory of Local Boiling Burnout and Its Application to Existing Data",

Chem. Eng. Progress Symposium Series No. 30, Vol. 56, pp 95-116., 1960 6

INDEPENDENT REVIEW John Bolin -

Review results (Thermal Hydraulics):

No comments on the thermal hydraulic analyses.

4

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 APPENDIX A - INDEPENDENT REVlIEW REPORT A-i

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 CALCULATION REVIEW REPORT TITLE DOCUMENT NUMBER REV Suppori Colculallono for MUTR's Maxirnum Inlet Tcmporuhurn 911200 0

INDEPENDENT REVIEWER:

NAIME:

John Bolin ORGANIZATION:

480 MODULAR HELIUM REACTOR MANAGER:

Tony Veca NAMEIATR REVIEW CRITERIA YES NO COMMENT REVIEW CALCULATION METHOD 0]

COMPARE CALCULATION METHOD WITH SIMILAR APPROVED METHOD 0-'

0 PREPARE ALTERNATE CALCULATION USING DIFFERENT METHOD 0]

[]

REVIEW ASSUMPTIONS:

  • UNIQUELY IDENTIFIED 0]

- ADEQUATELY DESCRIBED 0]

0

- REASONABLE, 0]

0

- UNCONFIRMED SPECIFICALLY IDENTIFIED 0]

0 REV1EW INPUTS 0*

0]

REVIEW RESULTSJCONCLUSIONS 0]

0 VERIFY COMPUTER CODE INFORMATION coRRECT

]

[

VERIFY GUALITY ASSURANCE LEVEL 0]

0

[]

D RECORD OR ATTACH 0] LIST OF DOCUMENTS USED IN REVIEW lAND/OR) 0] ALTERNATE CALCULATIONS OTHER REMARKS:

SCALCULATION FOUND TO BE VALID AND CONCLUSIONS TO BE CORRECT (OR) 0 EXCEPT AS NOTED ABOVE.

IN*DEPENDENT REVIEWER

/~G]'

'**DATE 7/

/`

FINAL REVIEW BEFORE ISSUEJRELEASE:

INDEPENDNT REVIWER

(

IGNATURE

~DT A-2

Support Calculations for MUTR's Maximum Inlet Temperature 911206/0 APPENDIX B - CALCULATION FILE LISTINGS B-1

Support Calculations for MUTR's Maximum Inlet Temperature Calculation files in support of Section 3.

911206/0 File Description File Type DVD Director Location MUT RLAPDNR npu fle RELAP5 input MUTR_dnbr 600kW_40C.inp 600kW, 40C___________________________

MUTR RELAP DNBR output file RELAP5 output MUTR_dnbr 600kW_40C.out 600kW, 40C MUT RLAPDNR npu fle RELAP5 input MUTR dnbr_600kW_80C.inp 600kW, 80C______________

MUTR RELAP DNBR output file RELAP5 output MUTR dnbr_600kW_80C.out 600kW, 80C MUT RLAPDNR npu fle RELAP5 input MUTR dnbr_600kW_90C.inp 600kW, 90C MUTR RELAP DNBR output file RELAP5 output MUTR_dnbr_600kW_90C.out 600kW, 90C MUT RLAPDNR npu fle RELAP5 input MUTR_dnbr_600kW_92C.inp 600kW, 92C_

MUTR RELAP DNBR output file RELAP5 output MUTR dnbr_600kW_92C.out 600kW, 92C____________________________

MUTR MathCAD file MathCAD Bernath dnbr.rncd B-2

+GENERAL ATOMVICS P.O0 BOX 85608 SAN DIEGO, GA 92186-5608 (858) 455-3000