Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Placing an RPS Channel in Trip JPM NUMBER:

557 REVISION: 1 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-099-SU-06 Assist US in performing of TSV RPS Surveillance.

K/A RATINGS:

RO: 3.9 SRO: 4.2 K/A No. &STATEMENT: 2.1.25 Ability to interpret reference materials, such as graphs, curves, tables, etc.

RELATED PRA INFORMATION: Risk Significant RPS Scram Reduction SAFETY FUNCTION:

Conduct of Operations EVALUATION LOCATION: In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number: _557___

RO ____

SRO ____

DATE: _______

TASK STANDARD: For failed Turbine Stop Valve #3 limit switches determine how to place the RPS instrument channel in the tripped condition PRA: NA REFERENCES/PROCEDURES NEEDED: Hard Copy of 3-OI-99, Reactor Protection System VALIDATIONTIME:

PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

IF UNSAT results are obtained THEN Retain entire JPM for records.(Otherwise just retain this page.)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

05/27/10 All Initial issue 1

07/23/15 All Reformatted to match template

Job Performance Measure (JPM) 4 INITIAL CONDITIONS: Turbine Stop Valve #3 limit switches failed the surveillance 3-SR-3.3.1.1.14(8I) Turbine Stop Valve Closure - RPS Trip (Channel A1/A2) and RPT Trip (System A & B) Logic System Functional Test. Unit 3 is currently at 75% power.

INITIATING CUES: The Unit Supervisor directs you as the Reactor Operator to identify how to place Turbine Stop Valve #3 (3-FCV-1-84) RPS channel in trip to satisfy Technical Specifications. You will need to identify any procedure you may need for the task, to the evaluator.

Answer:

Job Performance Measure (JPM) 5 START TIME:

STEP / STANDARD SAT / UNSAT Step 1: Refers to 3-OI-99 Reactor Protection System Standard:

Determines fuses 3-FU1-1-84A (5A-F10C) need to be removed Critical Step SAT UNSAT N/A Step 2: Refers to 3-OI-99 Reactor Protection System Standard:

Determines fuses 3-FU1-1-84 B (5A-F10F) need to be removed Critical Step SAT UNSAT N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT / UNSAT Termination Criteria: Once the Operator identifies that both the 3-FU1-1-84 A and 3-FI1-1-84 B must be removed the JPM can be ended.

STOP TIME:

End of Task

Job Performance Measure (JPM) 7 Provide to Applicant INITIAL CONDITIONS: Turbine Stop Valve #3 limit switches failed the surveillance 3-SR-3.3.1.1.14(8I) Turbine Stop Valve Closure - RPS Trip (Channel A1/A2) and RPT Trip (System A & B) Logic System Functional Test. Unit 3 is currently at 75% power.

INITIATING CUES: The Unit Supervisor directs you as the Reactor Operator to identify how to place Turbine Stop Valve #3 (3-FCV-1-84) RPS channel in trip to satisfy Technical Specifications. You will need to identify any procedure you may need for the task, to the evaluator.

Answer:

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine the Shift Staffing is adequate for your Crew JPM NUMBER:

678 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-000-AD-17, Observe Conduct Of Operations Guidelines K/A RATINGS:

RO 3.3 SRO 3.8 K/A STATEMENT:

2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR55, etc.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 678.

SRO DATE: _______

TASK STANDARD: Using OPDP-1 for Shift staffing, determines that a callout is required for one RO and one AUO.

PRA: NA REFERENCES/PROCEDURES NEEDED: OPDP-1; Conduct of Operations and Shift Managers Manning Sheet attached.

OPDP-10 License Status Maintenance, Reactivation and Proficiency for Non-Licensed Positions VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

07/24/15 All Initial issue

Job Performance Measure (JPM) 4 INITIAL CONDITIONS: You are the Shift Manager on nights, who is assigned to verify shift staffing requirements are met for upcoming Day Shift crew.

INITIATING CUES: Review the attached manning sheet in accordance with plant procedures and determine if any action is required.

Job Performance Measure (JPM) 5 START TIME STEP / STANDARD SAT /

UNSAT Step 1:

Reviews, Conduct of Operations OPDP-1 Rev. 0034 Page 57 of 74 (Page 2 of 2)

Shift Staffing 1.0 SHIFT STAFFING (continued)

Minimum Staffing BFN Shift Manager (SRO) 1 Unit Supervisor (SRO) 4 Unit Operator (UO) 6 Non Licensed (AUO) 9 STA 1

Incident Commander 1

Standard:

Reviews, Conduct of Operations OPDP-1 Attachment 1 for BFN Staffing requirements

___SAT

___UNSAT

___N/A Note to Examiner, the applicant may just identify the missing people and then state that he would call out for 2 ROs and 1 AUO. If he does that, he should be cued that on the call out that only 1 RO and 1 AUO are available, and ask if he has minimum staffing.

Manning can be met by doing any of the following for the missing RO:

1. Hold someone over for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> until a callout for an additional RO can be made, per OPDP-1
2. Move an SRO down to cover the missing RO, per OPDP-10.

Step 2: Applicant notes that U1BOARD RO and Unit 2 BOARD ROs are vacant.

Standard: Applicant notes that there are 2, too few ROs for minimal staffing, and will call out for two ROs or move one SRO down and call out for one RO, or hold someone over for up to four hours until additional callouts can be made.

Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT /

UNSAT Step 3: Applicant notes that RW DEMINS AUO is vacant.

Standard:

Applicant notes that there is 1 too few AUOs to man Emergency Responder positions, and they cannot be filled on shift, because the two extra people are shown with an (s) beside their names, meaning that they cannot fill an ER position. A callout will need to be made for an additional AUO.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 7 Provide to Applicant INITIAL CONDITIONS: You are the Shift Manager on nights, who is assigned to verify shift staffing requirements are met for upcoming Day Shift crew.

INITIATING CUES: Review the attached manning sheet in accordance with plant procedures and determine if any action is required.

Job Performance Measure (JPM) 8 Provide to Applicant Shift Managers Manning Sheet Todays Date / Time DAYS NIGHTS Pager Group 2 Group 5 SM 30-590 7860 Hill SM Break-in STA 10-794 2168 Martin U1 SRO 2175 Jones U2 SRO 2269 Rodgers U3 SRO 2373 Speckman WCC 16-139 Hardin IC Holder Extra U1BOARD RO 2192 U1DESK RO 2191 Oleson U2 BOARD RO 2292 U2 DESK RO 2291 Werner U3 BOARD RO 2392 Astoske U3 DESK RO 2391 Block RELIEF / SST 2166 Support Support Break-in RW UO 60-793 2372 James (s)

U1 TB (#)15-026 6465 Aman ER1 ER1 U1 RB 14-335 6457 Intauno ER2 ER2 RW DEMINS14-878 2370 ER3 ER3 U2 TB 94-749 6444 Mascareno ER4 ER4 U2 RB 15-957 6441 Tew ER5 ER5 OUTSIDE AUO 14-414 6451 Becker ER6 ER6 U3 TB (#)94-016 6450 Best ER7 ER7 U3 RB 16-598 Logins ER8 ER8 CONTROL BAY 91-673 6453 Morton ER9 ER9 Fire Watch Fire Watch WCC Harrison (s)

WCC WCC WCC SGPO SGPO Maintenance MGR 729-7677 / 434-0824 / 16-057 (I) Incident Commander OPS Clerks 729-2302 (TRN) Training Cooling Towers 614-6297 / 434-0830 (J) JITT

(#) Fire Cage Responder ER1-ER9 Assume Emergency Responder Positions (s) Not Emergency Responder Qualified ER9 NRC Phone Communicator

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine the required action for rod pull (calculate period)

JPM NUMBER:

675 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-000NO-03 Perform Reactor Startup K/A RATINGS:

RO 4.3 SRO 4.6 K/A STATEMENT:

2.1.37 Knowledge of procedures, guidelines, or limitations associated with reactivity management.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 675.

RO DATE: _______

TASK STANDARD: Calculates reactor period to be 55 seconds and list the steps for inserting the notched control rod until reactor period is greater than 60 seconds.

PRA: NA REFERENCES/PROCEDURES NEEDED: GOI-100-1A, Unit Startup and Power Operation VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: You are a Reactor Operator performing a startup in accordance with GOI-100-1A Unit Startup and Power Operation, where initial IRM readings are as follows:

A. 25/125 on range 3 B. 27/125 on range 3 INITIATING CUES: A control rod is withdrawn one notch and 38 seconds later the IRMs are reading the following:

A. 50/125 on range 3 B. 54/125 on range 3 What action(s) is/are required?

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: Applicant calculates reactor period given the initial and final IRM readings.

Standard:

Period of 55 seconds + 3 seconds is determined.

Doubling Time x 1.445 = period 38 seconds x 1.445 = 54.9 seconds Critical Step

___SAT

___UNSAT

___N/A Step 2: Applicant determines required actions in accordance with GOI-100-1A, Unit Startup and Power Operation.

Standard:

Determines that the rod just pulled is required to be inserted until a stable period of greater than 60 seconds is observed.

Also that Reactor Engineer, Reactivity Manager, and Shift Managers permission is obtained prior to subsequent control rod withdrawal.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant INITIAL CONDITIONS: You are a Reactor Operator performing a startup in accordance with GOI-100-1A Unit Startup and Power Operation, where initial IRM readings are as follows:

A. 25/125 on range 3 B. 27/125 on range 3 INITIATING CUES: A control rod is withdrawn one notch and 38 seconds later the IRMs are reading the following:

A. 50/125 on range 3 B. 54/125 on range 3 What action(s) is/are required? Provide answer below

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine Fuel Handling fuel storage compliance JPM NUMBER:

677 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-NO-105; Receipt of New Fuel K/A RATINGS:

RO 2.2 SRO 3.9 K/A STATEMENT:

2.1.35;Knowledge of the fuel-handling responsibilities of SROs.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 677.

SRO DATE: _______

TASK STANDARD: Using 0-GOI-100-2 and a set of conditions for new fuel stored on the refueling floor, determines that some of the bundles are not in compliance with the GOI.

PRA: NA REFERENCES/PROCEDURES NEEDED:

0-GOI-100-2 VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Classroom INITIAL CONDITIONS: You are an SRO directing new fuel inspections for Unit 1. You find the following:

1. Two un-irradiated nuclear fuel bundles are in the fuel handling area.
2. Three un-irradiated nuclear fuel bundles are in the new fuel storage vault.
3. Four full Inner Shipping Containers (ISCs) are stacked within a couple of feet to the Equipment Hatch.
4. Two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

INITIATING CUES:

Determine compliance with Fuel Handling Procedures for Un-irradiated fuel being unloaded on the refuel floor.

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the two un-irradiated nuclear fuel bundles are in the fuel handling area.

Standard:

Determines that it is acceptable to have two un-irradiated nuclear fuel bundles are in the fuel handling area.

___SAT

___UNSAT

___N/A Step 2: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the three un-irradiated nuclear fuel bundles are in the new fuel storage vault.

Standard:

Determines that it is NOT acceptable to have three un-irradiated nuclear fuel bundles are in the new fuel storage vault. Reference 0-GOI-100-2 Step 3.7 H Critical Step

___SAT

___UNSAT

___N/A Step 3: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the four full Inner Shipping Containers (ISCs) that are stacked within a couple of feet to the Equipment Hatch.

Standard:

Determines that it is NOT acceptable to have Four full Inner Shipping Containers (ISCs) that are stacked within a couple of feet to the Equipment Hatch. Reference 0-GOI-100-2 Step 3.2 B Critical Step

___SAT

___UNSAT

___N/A Step 4: Applicant assesses the two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools Standard:

Determines that it is acceptable to have two full Inner Shipping Containers (ISCs) lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant Classroom INITIAL CONDITIONS: You are an SRO directing new fuel inspections for Unit 1.

1. Two un-irradiated nuclear fuel bundles are in the fuel handling area.
2. Three un-irradiated nuclear fuel bundles are in the new fuel storage vault.
3. Four full Inner Shipping Containers (ISCs) are stacked within a couple of feet to the Equipment Hatch.
4. Two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

INITIATING CUES:

Determine compliance with Fuel Handling Procedures for Un-irradiated fuel being unloaded on the refuel floor.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Perform Jet Pump Mismatch and Operability SR (RO)

JPM NUMBER:

680 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-068-SU-05; Perform Jet Pump Mismatch and Operability K/A RATINGS:

RO 3.7 SRO 4.1 K/A STATEMENT:

2.2.12; Knowledge of surveillance procedures.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Equipment Control EC EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 680.

RO DATE: _______

TASK STANDARD:

PRA: NA REFERENCES/PROCEDURES NEEDED: 2-SR-3.4.2.1 Jet Pump Mismatch and Operability VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 Operator.

CALC002 = 3456 CMWT 2-XR-68-50 Green Pen = 17 2-XR-68-50 Red Pen =

97 Recirc Motor Speeds 2A 2-SI-96-61 = 1456 2B 2-SI-96-73 = 1455 Recirc Pump Discharge Flows 2-FI-68-5 = 45 2-FI-68-81 = 44 (Continued)

Job Performance Measure (JPM) 4 INITIATING CUES: Perform 2-SR-3.4.2.1; Jet Pump Mismatch and Operability starting at step 7.2.1, using the provided readings.

Job Performance Measure (JPM) 5 START TIME STEP / STANDARD SAT /

UNSAT Step 1: 7.2.1 Core Power and Flow Readings

[1] RECORD the Core Thermal Power from Core Power and Flow Log. (N/A if ICS is NOT available) Point CALC002 _________CMWT Standard:

Records 3456 CMWT Critical Step

___SAT

___UNSAT

___N/A Step 2:

[2] RECORD the Core Plate Differential Pressure from ICS point 68-52 or 2-XR-68-50 (Green Pen). (N/A if not available)

Core Press Drop 68-52 __________PSID Standard:

Records 17 PSID Critical Step

___SAT

___UNSAT

___N/A Step 3:

[3] RECORD the Total Core Flow. Total Core Flow (Red Pen) 2-XR-68-50

________ Mlb/hr Standard:

Records 97 Mlb/hr Critical Step

___SAT

___UNSAT

___N/A Step : 7.2.2 Recirculation Pump Loops

[1] RECORD the Recirc Pump 2A and 2B Mtr Speeds for operating Recirc Pumps and MARK instrumentation used.

Pump Motor 2A Pump Motor 2B 2-SI-68-59 2-SI-68-71 2-SIT-068-0059 2-SIT-068-0071 2-SI-96-61 2-SI-96-73

________ RPM ________ RPM Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT /

UNSAT Standard:

Records the following.

Pump Motor 2A Pump Motor 2B 2-SI-68-59 2-SI-68-71 2-SIT-068-0059 2-SIT-068-0071 2-SI-96-61 2-SI-96-73

_1456__ RPM __1455__ RPM Step :

[2] RECORD the Recirc Pump Discharge flows.

Loop 2A Loop 2B 2-FI-68-5 2-FI-68-81

________ gpm X 1000 ________ gpm X 1000 Standard:

Records the following.

Loop 2A Loop 2B 2-FI-68-5 2-FI-68-81

___45 _ gpm X 1000 ___44 _ gpm X 1000 Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 7 STEP / STANDARD SAT /

UNSAT Step :

[3] RECORD the Recirc Loop 2A and 2B Jet Pump Flow.

Loop 2A Loop 2B 2-FI-68-46 2-FI-68-48

________ Mlb/hr ________ Mlb/hr Standard:

Records the following.

Loop 2A Loop 2B 2-FI-68-46 2-FI-68-48

___50 _Mlb/hr _ 49 _Mlb/hr Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 8 STEP / STANDARD SAT /

UNSAT Step : 7.2.3 Jet Pump Loops

[1] RECORD the following Differential Pressure readings below:

Standard:

Critical Step

___SAT

___UNSAT

___N/A 11 11 11 11 17.5 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11

Job Performance Measure (JPM) 9 STEP / STANDARD SAT /

UNSAT Step : 7.3 Tech Spec 3.4.1.1 - Recirculation Loop Mismatch Verification With Both Recirculation Loops In Operation Checks

[1] CALCULATE percent of Rated Core Flow (%WT) using data obtained in Section 7.2.1[3] as follows.

(Step 7.2.1[3] ÷102.5) X 100 =

% Core Flow

(__________ ÷ 102.5) X 100 =

Standard:

Records the following (Step 7.2.1[3] ÷102.5) X 100 =

% Core Flow

( 97 Mlb/hr ÷ 102.5) X 100 = _94.63 %__

Critical Step

___SAT

___UNSAT

___N/A Step :

[2] CALCULATE the absolute value for Recirculation Loop Jet Pump Flow Mismatch using data obtained in Section 7.2.2[3] as follows.

2-FI-68-46 2-FI-68-48

=

Mismatch

_______ Mlb/hr -

_______ Mlb/hr = _______ Mlb/hr Standard:

Records the following 2-FI-68-46 2-FI-68-48

=

Mismatch

_50 _Mlb/hr -

_49 _ Mlb/hr = _1 _ Mlb/hr Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 10 STEP / STANDARD SAT /

UNSAT Step :

[3] IF %WT is < 70% as recorded in Step 7.3[1], THEN CHECK Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is < 10.25.12 Mlb/hr.

Standard:

Marks step N/A

___SAT

___UNSAT

___N/A Step :

[4] IF %WT is > 70% as recorded in Step 7.3[1], THEN CHECK Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is <5.12 Mlb/hr.

Standard:

CHECKS Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is < 5.12 Mlb/hr. and initials the step Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.1 Loop 2A Recirculation Pump and Jet Pump Flow to Recirculation Pump Speed

[1] Using the 2A Pump Speed recorded in Step 7.2.2[1] and the 2A Pump Flow recorded in Step 7.2.2[2]:

CHECK the plot falls between the two bold lines on and RECORD below.

Plot falls between the bold lines Yes No Standard: CHECKS the plot falls between the two bold lines on Attachment 1 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 11 STEP / STANDARD SAT /

UNSAT Step :

[2] Using the 2A Pump Speed recorded in Step 7.2.2[1] and the 2A Jet Pump Flow in Step 7.2.2[3]: CHECK the plot falls between the two bold lines on and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 2 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.1[1] and 7.4.1[2] from above: DETERMINE if the Jet Pump Loop 2A criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2A criteria is satisfied Yes No Standard:

DETERMINES if the Jet Pump Loop 2A criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2A criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.2 Loop 2B Recirculation Pump and Jet Pump Flow to Recirculation Pump Speed

[1] Using the 2B Pump Speed recorded in Step 7.2.2[1] and 2B Pump Flow recorded in Step 7.2.2[2]:

CHECK the plot falls between the two bold lines on Attachment 3 and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 3 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 12 STEP / STANDARD SAT /

UNSAT Step :

[2] Using the 2B Pump Speed recorded in Step 7.2.2[1] and 2B Jet Pump Flow recorded in Step 7.2.2[3]:

CHECK the plot falls between the two bold lines on Attachment 4 and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 4 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.2[1] and 7.4.2[2] from above:

DETERMINE if the Jet Pump Loop 2B criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2B criteria is satisfied Yes No Standard:

DETERMINE if the Jet Pump Loop 2B criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2B criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.3 Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification:

[1] Using the individual 2A Jet Pump DPs recorded in Step 7.2.3[1]

CHECK each individual Jet Pump DP recorded fall between the two bold lines on for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2A Individual DPs are between the bold lines. Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 13 STEP / STANDARD SAT /

UNSAT Standard:

CHECKS each individual Jet Pump DP recorded fall between the two bold lines on Attachment 5 for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2A Individual DPs are between the bold lines. Yes No Step :

[2] Using the individual 2B Jet Pump DPs recorded in Step 7.2.3[1]

CHECK each individual Jet Pump DP recorded fall between the two bold lines on for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2B Individual DPs are between the bold lines. Yes No Standard:

CHECKS each individual Jet Pump DP recorded fall between the two bold lines on Attachment 6 for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2B Individual DPs are between the bold lines. Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.3[1] and 7.4.3[2]

DETERMINE whether the Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied Yes No Standard:

DETERMINES whether the Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 14 STEP / STANDARD SAT /

UNSAT Step : 7.4.4 Engineering Judgment/Review Criteria

[1] IF any of the following conditions apply:

  • Following Refueling Outage. (See Caution above)

OR

  • The Reactor is in Single Loop Operation (See Caution above)

OR

  • If point(s) plotted in Sections 7.4.1 or 7.4.2, AND 7.4.3 fall on or outside the bolded lines, to determine if the graph(s) need updating, THEN PERFORM Attachment 7, Engineering Judgment/Review:

(Otherwise N/A this step and Mark all of Attachment 7 as N/A)

Standard:

Evaluates step and determines that this step is N/A

___SAT

___UNSAT

___N/A Step :

7.4.5 Operability Determination

[1] MARK the appropriate criteria results for the following. (N/A any criteria not performed)

Steps Criteria Results Yes No N/A 7.4.1[3] and 7.4.2[3]

Both Jet Pump Loops steps are marked as YES 7.4.3[3]

Jet Pump DP to criteria is marked as YES.

Engineering Evaluation is marked as YES.

Standard:

MARKS the appropriate criteria results for the following. (N/A any criteria not performed)

Steps Criteria Results Yes No N/A 7.4.1[3] and 7.4.2[3]

Both Jet Pump Loops steps are marked as YES 7.4.3[3]

Jet Pump DP to criteria is marked as YES.

Engineering Evaluation is marked as YES.

Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 15 STEP / STANDARD SAT /

UNSAT Step :

7.5 Completion and Notifications

[1] IF an Engineering Judgment/Review was performed, THEN ENSURE the Engineering Judgment/Review documentation is attached to this SR. (Otherwise N/A) ________

Standard:

Determines this step is N/A

___SAT

___UNSAT

___N/A Step :

[2] On the Surveillance Task Sheet (STS)

[2.1] RECORD the Completion Date & Time. ________

[2.2] REVIEW and COMPLETE through the Test Director/Lead Performer & Date fields. ________

Standard:

[2] On the Surveillance Task Sheet (STS)

[2.1] RECORDS the Completion Date & Time. ________

[2.2] REVIEWS and COMPLETES through the Test Director/Lead Performer &

Date fields. ________

___SAT

___UNSAT

___N/A Step :

[3] NOTIFY the Unit Supervisor that this test is complete.

Standard:

NOTIFIES the Unit Supervisor that this test is complete.

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 16 Provide to Applicant INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 Operator.

CALC002 = 3456 CMWT 2-XR-68-50 Green Pen = 17 2-XR-68-50 Red Pen =

97 Recirc Motor Speeds 2A 2-SI-96-61 = 1456 2B 2-SI-96-73 = 1455 Recirc Pump Discharge Flows 2-FI-68-5 = 45 2-FI-68-81 = 44

Job Performance Measure (JPM) 17 (Continued)

INITIATING CUES: Perform 2-SR-3.4.2.1; Jet Pump Mismatch and Operability starting at step 7.2.1, using the provided readings.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Review Completed SR (SRO)

JPM NUMBER:

676 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-AD-27, Assess LCO/TRM Actions to determine operability K/A RATINGS:

RO SRO 4.7 K/A STATEMENT:

2.2.22; Knowledge of limiting conditions for operations and safety limits RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Equipment Control EC EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 676 A.

SRO DATE: _______

TASK STANDARD: Determines that the SR for the Jet Pump Operability has not been filled out correctly and that Jet Pump 15 is actually inoperable. And enters LCO 3.4.2 Jet Pumps Condition A, Required Action A.1 Be in mode 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

PRA: NA REFERENCES/PROCEDURES NEEDED: Completed 2-SR-3.4.2.1 Jet Pump Mismatch

& Operability, with Jet pump 15 inop, but not identified by the Unit Operator.

VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 US and the UO has just completed the Jet Pump SR and it is ready to review.

INITIATING CUES: As the Unit Supervisor review the attached completed 2-SR-3.4.2.1.

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: US checks that the Unit Operator has checked and initialed each step.

Standard:

US notes that all initials are present and all calculations are completed.

___SAT

___UNSAT

___N/A Step 2: US checks that the UO has identified any anomalies.

Standard:

US notes that the UO incorrectly identified that Jet Pump 15 was within the graph curves however it fell outside the curves.

Critical Step

___SAT

___UNSAT

___N/A Step 3: US declares Jet Pump Inoperable.

Standard:

US reviews Tech Spec 3.4.2.1 and Bases and declares Jet Pump 15 Inoperable.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant INITIAL CONDITIONS: Unit 1 is operating at 100% power. You are the Unit 1 US and the UO has just completed the Jet Pump SR and it is ready to review.

INITIATING CUES: As the Unit Supervisor review the attached completed 1-SR-3.4.2.1.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Upgrade PAR on wind shift.

JPM NUMBER:

679 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-EM Classify and Declare an Abnormal /

Emergency Event K/A RATINGS:

RO: SRO: 4.4 K/A No. &STATEMENT: 2.4.44; Knowledge of emergency plan protective action recommendations RELATED PRA INFORMATION: Risk Significant SAFETY FUNCTION:

EP EVALUATION LOCATION: In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number: _679___

SRO DATE: _______

TASK STANDARD: Addresses the change in conditions and performs Attachment H of EPIP-5 then with that assessment completed, updates the Protective Action Requirement of EPIP-5 Appendix F.

Operator Fundamental evaluated:

OF-1 Monitoring plant indications and conditions closely.

PRA: NA REFERENCES/PROCEDURES NEEDED:

EPIP - 5 partially filled out.

VALIDATIONTIME:

PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

IF UNSAT results are obtained THEN Retain entire JPM for records. (Otherwise just retain this page.)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

08-4-15 All Initial issue

Job Performance Measure (JPM) 4 CLASSROOM INITIAL CONDITIONS: You are the Shift Manager during a General Emergency Classification for Unit 1 and the attached EPIP-5 Appendix A was filled out 45 minutes ago. The TSC is not operational yet.

Conditions at the current time are as follows:

Unit1: Parameters consistent with 2.1-G.

Onsite Protective Actions Assembly and Accountability are completed.

Unit 2: At Power Unit 3: At Power Meteorological Wind speed 20 mph gusting to 30 mph Wind direction 280º INITIATING CUES: Assess the new information and perform the required actions using the attached EPIP-5.

Job Performance Measure (JPM) 5

Job Performance Measure (JPM) 6 KEY

Job Performance Measure (JPM) 7 KEY

Job Performance Measure (JPM) 8 START TIME:

STEP / STANDARD SAT / UNSAT Step 1:

The applicant reviews the new information provided.

Standard:

The applicant notes that the only significant change is Wind direction.

SAT UNSAT N/A Step 2:

EPIP-5 3.6 Monitor / Re-evaluate the Event Appendix E

[1] IF significant changes in plant conditions occur, THEN DIRECT a member of the Operations staff (SRO if available) to complete Appendix F General Emergency Follow-Up Information Form, otherwise Continue in this Appendix at Step 2.0.

Standard:

The applicant identifies that Appendix F is needed.

Critical Step SAT UNSAT N/A Step 3:

EPIP-5 Appendix H PAR Flowchart is used to determine that the PAR essentially stays the same and proceeds to fill out Appendix F Standard:

Appendix H PAR Flowchart is marked similarly to the KEY provided.

SAT UNSAT N/A

Job Performance Measure (JPM) 9 STEP / STANDARD SAT / UNSAT Step 2:

EPIP-5 3.6 Monitor / Re-evaluate the Event Appendix F is used to communicate Follow-Up information. Continue to conduct State Follow-Ups until the CECC has assumed State Communications responsibilities.

Standard:

The applicant fills out EPIP-5 Appendix F to match the KEY Provided.

Critical Step SAT UNSAT N/A Termination Criteria: When the candidate has completed filling out Appendix F, the JPM can end.

STOP TIME:

Job Performance Measure (JPM) 10 Provide to Applicant CLASSROOM INITIAL CONDITIONS: You are the Shift Manager during a General Emergency Classification for Unit 1 and the attached EPIP-5 Appendix A was filled out 45 minutes ago. The TSC is not operational yet.

Conditions at the current time are as follows:

Unit1: Parameters consistent with 2.1-G.

Onsite Protective Actions Assembly and Accountability are completed.

Unit 2: At Power Unit 3: At Power Meteorological Wind speed 20 mph gusting to 30 mph Wind direction 280º INITIATING CUES: Assess the new information and perform the required actions using the attached EPIP-5

Job Performance Measure (JPM) 11 Provide to Applicant

Job Performance Measure (JPM) 12 Provide to Applicant within 15 minutes

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Review a Radiological Survey Map JPM NUMBER:

544 REVISION: 3 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): A-000-AD-35 / Use a Radiation Work Permit K/A RATINGS:

K/A RATING: RO 3.5 SRO 3.6 K/A STATEMENT:

2.3.7 Ability to comply with radiation work permit requirements during normal or abnormal conditions.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION: RAD CONTROL EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number __544___

RO SRO DATE: _______

TASK STANDARD: Review a Radiological Survey Map to determine if a task can be completed without exceeding exposure limits PRA: NA REFERENCES/PROCEDURES NEEDED:

None VALIDATION TIME: 10 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Classroom INITIAL CONDITIONS:

You are a Browns Ferry employee who has obtained a cumulative yearly dose of 500 mrem.

The job will require you to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. To manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 15 minutes to install the mechanical restraining device.

The map of the room has radiological survey information you must interpret to successfully complete this JPM.

Assume that any transit time has NO dose.

INITIATING CUE:

Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding and RWP or TVA limits.

Job Performance Measure (JPM) 4 EXAMINER KEY ANSWER:

10 min to close valve + 15 min to install device = 25 min 25/60 = 0.417 hrs 0.417 hrs x 300 mr/hr = 125 mrem to close valve & install device (Between 122.0 to 127.0) (Critical) 125 + 500 = 625 (Yes - within both TVA annual limit of 1Rem and RWP Dose and Dose Rate limits, work areas at 30cm dose rate 300 mrem < 500 mrem rate alarm) (Critical)

Job Performance Measure (JPM) 5 Provide to Applicant Classroom INITIAL CONDITIONS:

You are a Browns Ferry employee who has obtained a cumulative yearly dose of 500 mrem.

The job will require you to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. To manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 15 minutes to install the mechanical restraining device.

The map of the room has radiological survey information you must interpret to successfully complete this JPM.

Assume that any transit time has NO dose.

INITIATING CUE:

Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding and RWP or TVA limits.

Job Performance Measure (JPM) 6 Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY GENERAL DESCRIPTION Status: Active Start Date: 01-Jan-This year End Date: 01-Jan-Next year Type: SPECIFIC MAP ID: Outage: Y Name:

Task: ROUTINE PLANT MAINTENANCE PSE: N HP CONTINUOUS Authorization Type: INDIVIDUAL ALARA Review Number: 0A-0010 Primary Work Doc:

Person-mrem Estimate: 1904 Person-Hrs Estimate: 1082 Dose Alarm: 300 Dose Rate Alarm: 500 DAC-Hrs Tracked: N Work Area

Description:

Unit 3 Areas All Elevations DESCRIPTION OF WORK TO BE PERFORMED Unit 3 Maintenance on RWCU (69) Systems (LHRA VARIOUS DRESS) 200 / 250 / 500 ANTI-CONTAMINATION CLOTHING REQUIREMENTS 1 LAB COAT 1,2 BOOTIES, CLOTH, ONE PAIR 1,2 GLOVES, RUBBER, ONE PAIR 1,2,3 CLOTH INSERTS 1,2,3 SHOE COVERS, ONE PAIR 1,2,3 MODESTY CLOTHING 1,2,3 NO PERSONAL OUTER CLOTHING 1,2,3 SURGEON'S CAP 2,3 COVERALLS, ONE PAIR 3 BOOTIES, PLASTIC, TWO PAIR 3 FACE SHIELD 3 RAIN SUIT 3 GLOVES, RUBBER, TWO PAIR 3,4 HOOD DOSIMETRY REQUIREMENTS ELECTRONIC DOSIMETER TLD BRIEFING REQUIREMENTS PRE-JOB BRIEFING EQUIS WORK STEPS 1 MANAGEMENT / WO WALKDOWN 2 3-CI-412 3 OPS VALVE LINEUP OI-69 & HX VENTING 4 07-712928-000 5 06-722560-000

Job Performance Measure (JPM) 7 Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY WORKER INSTRUCTIONS 1 DRESSOUT CODE APPLICATIONS

1) FLOOR LEVEL INSP, LOW TO MODERATE CONTAMINATION.
2) MINOR MAINTENANCE, NO PRIMARY SYSTEM BREACH.
3) PRIMARY SYSTEM BREACH, HEAT EXCHANGER VENTING.
4) ANY WORK ABOVE FLOOR LEVEL REQUIRES SAFETY BELT W/ LIFELINE.
5) REQUIRED TO WEAR HEADGEAR OTHER THAN PERSONAL HARDHAT.

2 MONITOR YOUR ED (DAD) FREQUENTLY, EXIT THE AREA PRIOR TO REACHING THE DOSE ALARM SET POINT OR UPON RECEIVING ANY UNEXPECTED ALARMS.

3 DO NOT EXCEED 250 mrem PER ENTRY OR DOSE MARGIN (RAD-REMAINING ALLOWABLE DOSE).

4 REMOTE MONITORING, PEA, OR SIMILAR DEVICE REQUIRED.

5 ED (DAD) TO BE BAGGED (WRAPPED) AND WORN OUTSIDE OF C-ZONE CLOTHING.

6 REVIEW PLANNED WORK OR INSPECTIONS WITH RAD PROTECTION PRIOR TO ENTRY.

7 UTILIZE TIME, DISTANCE, AND SHIELDING ALARA PRINCIPLES.

8 REVIEW APPROPRIATE SURVEY DATA PRIOR TO ENTRY. NOTE AND AVOID POSTED HOT SPOTS. LOCATE AND UTILIZE LOW DOSE WAITING AREAS.

9 RADWORKER SHALL ADHERE TO ANY SPECIAL INSTRUCTIONS (APR, ETC) ON WHICH HE/SHE HAS BEEN BRIEFED BY RAD PROTECTION.

10 NOTIFY RADCON PRIOR TO ANY SYSTEM BREACH.

11 RAD PROTECTION COVERAGE MAY BE PROVIDED FROM OUTSIDE THE C-ZONE.

12 SECURE ALL HOSES, ELECTRICAL CORDS, WELDING LEADS AND OTHER SERVICES ENTERING THE C-ZONE AT THE C-ZONE BOUNDRY AND NOTIFY RAD PROTECTION.

13 NOTIFY RAD PROTECTION OF ANY UNUSUAL RADIOLOGICAL CONDITIONS (FOR EXAMPLE:

WATER, LEAKS, RADIATION MONITOR ALARMS).

14 RAD PROTECTION PERMISSION REQUIRED PRIOR TO WELDING, GRINDING, BUFFING OR OTHER SURFACE DISTURBING ACTIVITIES.

APPROVAL Prepaired by: TJFRANK Approved by: MJHAZEL Final Approval: JWSMITH3 End of RWP

Job Performance Measure (JPM) 8 Provide to Applicant DR 11

  • 600

+300 45 Date/Time: Today 1 Hr ago DR 8

  • 1200

+500 320

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Placing an RPS Channel in Trip JPM NUMBER:

557 REVISION: 1 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-099-SU-06 Assist US in performing of TSV RPS Surveillance.

K/A RATINGS:

RO: 3.9 SRO: 4.2 K/A No. &STATEMENT: 2.1.25 Ability to interpret reference materials, such as graphs, curves, tables, etc.

RELATED PRA INFORMATION: Risk Significant RPS Scram Reduction SAFETY FUNCTION:

Conduct of Operations EVALUATION LOCATION: In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number: _557___

RO ____

SRO ____

DATE: _______

TASK STANDARD: For failed Turbine Stop Valve #3 limit switches determine how to place the RPS instrument channel in the tripped condition PRA: NA REFERENCES/PROCEDURES NEEDED: Hard Copy of 3-OI-99, Reactor Protection System VALIDATIONTIME:

PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

IF UNSAT results are obtained THEN Retain entire JPM for records.(Otherwise just retain this page.)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

05/27/10 All Initial issue 1

07/23/15 All Reformatted to match template

Job Performance Measure (JPM) 4 INITIAL CONDITIONS: Turbine Stop Valve #3 limit switches failed the surveillance 3-SR-3.3.1.1.14(8I) Turbine Stop Valve Closure - RPS Trip (Channel A1/A2) and RPT Trip (System A & B) Logic System Functional Test. Unit 3 is currently at 75% power.

INITIATING CUES: The Unit Supervisor directs you as the Reactor Operator to identify how to place Turbine Stop Valve #3 (3-FCV-1-84) RPS channel in trip to satisfy Technical Specifications. You will need to identify any procedure you may need for the task, to the evaluator.

Answer:

Job Performance Measure (JPM) 5 START TIME:

STEP / STANDARD SAT / UNSAT Step 1: Refers to 3-OI-99 Reactor Protection System Standard:

Determines fuses 3-FU1-1-84A (5A-F10C) need to be removed Critical Step SAT UNSAT N/A Step 2: Refers to 3-OI-99 Reactor Protection System Standard:

Determines fuses 3-FU1-1-84 B (5A-F10F) need to be removed Critical Step SAT UNSAT N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT / UNSAT Termination Criteria: Once the Operator identifies that both the 3-FU1-1-84 A and 3-FI1-1-84 B must be removed the JPM can be ended.

STOP TIME:

End of Task

Job Performance Measure (JPM) 7 Provide to Applicant INITIAL CONDITIONS: Turbine Stop Valve #3 limit switches failed the surveillance 3-SR-3.3.1.1.14(8I) Turbine Stop Valve Closure - RPS Trip (Channel A1/A2) and RPT Trip (System A & B) Logic System Functional Test. Unit 3 is currently at 75% power.

INITIATING CUES: The Unit Supervisor directs you as the Reactor Operator to identify how to place Turbine Stop Valve #3 (3-FCV-1-84) RPS channel in trip to satisfy Technical Specifications. You will need to identify any procedure you may need for the task, to the evaluator.

Answer:

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine the Shift Staffing is adequate for your Crew JPM NUMBER:

678 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-000-AD-17, Observe Conduct Of Operations Guidelines K/A RATINGS:

RO 3.3 SRO 3.8 K/A STATEMENT:

2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR55, etc.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 678.

SRO DATE: _______

TASK STANDARD: Using OPDP-1 for Shift staffing, determines that a callout is required for one RO and one AUO.

PRA: NA REFERENCES/PROCEDURES NEEDED: OPDP-1; Conduct of Operations and Shift Managers Manning Sheet attached.

OPDP-10 License Status Maintenance, Reactivation and Proficiency for Non-Licensed Positions VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

07/24/15 All Initial issue

Job Performance Measure (JPM) 4 INITIAL CONDITIONS: You are the Shift Manager on nights, who is assigned to verify shift staffing requirements are met for upcoming Day Shift crew.

INITIATING CUES: Review the attached manning sheet in accordance with plant procedures and determine if any action is required.

Job Performance Measure (JPM) 5 START TIME STEP / STANDARD SAT /

UNSAT Step 1:

Reviews, Conduct of Operations OPDP-1 Rev. 0034 Page 57 of 74 (Page 2 of 2)

Shift Staffing 1.0 SHIFT STAFFING (continued)

Minimum Staffing BFN Shift Manager (SRO) 1 Unit Supervisor (SRO) 4 Unit Operator (UO) 6 Non Licensed (AUO) 9 STA 1

Incident Commander 1

Standard:

Reviews, Conduct of Operations OPDP-1 Attachment 1 for BFN Staffing requirements

___SAT

___UNSAT

___N/A Note to Examiner, the applicant may just identify the missing people and then state that he would call out for 2 ROs and 1 AUO. If he does that, he should be cued that on the call out that only 1 RO and 1 AUO are available, and ask if he has minimum staffing.

Manning can be met by doing any of the following for the missing RO:

1. Hold someone over for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> until a callout for an additional RO can be made, per OPDP-1
2. Move an SRO down to cover the missing RO, per OPDP-10.

Step 2: Applicant notes that U1BOARD RO and Unit 2 BOARD ROs are vacant.

Standard: Applicant notes that there are 2, too few ROs for minimal staffing, and will call out for two ROs or move one SRO down and call out for one RO, or hold someone over for up to four hours until additional callouts can be made.

Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT /

UNSAT Step 3: Applicant notes that RW DEMINS AUO is vacant.

Standard:

Applicant notes that there is 1 too few AUOs to man Emergency Responder positions, and they cannot be filled on shift, because the two extra people are shown with an (s) beside their names, meaning that they cannot fill an ER position. A callout will need to be made for an additional AUO.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 7 Provide to Applicant INITIAL CONDITIONS: You are the Shift Manager on nights, who is assigned to verify shift staffing requirements are met for upcoming Day Shift crew.

INITIATING CUES: Review the attached manning sheet in accordance with plant procedures and determine if any action is required.

Job Performance Measure (JPM) 8 Provide to Applicant Shift Managers Manning Sheet Todays Date / Time DAYS NIGHTS Pager Group 2 Group 5 SM 30-590 7860 Hill SM Break-in STA 10-794 2168 Martin U1 SRO 2175 Jones U2 SRO 2269 Rodgers U3 SRO 2373 Speckman WCC 16-139 Hardin IC Holder Extra U1BOARD RO 2192 U1DESK RO 2191 Oleson U2 BOARD RO 2292 U2 DESK RO 2291 Werner U3 BOARD RO 2392 Astoske U3 DESK RO 2391 Block RELIEF / SST 2166 Support Support Break-in RW UO 60-793 2372 James (s)

U1 TB (#)15-026 6465 Aman ER1 ER1 U1 RB 14-335 6457 Intauno ER2 ER2 RW DEMINS14-878 2370 ER3 ER3 U2 TB 94-749 6444 Mascareno ER4 ER4 U2 RB 15-957 6441 Tew ER5 ER5 OUTSIDE AUO 14-414 6451 Becker ER6 ER6 U3 TB (#)94-016 6450 Best ER7 ER7 U3 RB 16-598 Logins ER8 ER8 CONTROL BAY 91-673 6453 Morton ER9 ER9 Fire Watch Fire Watch WCC Harrison (s)

WCC WCC WCC SGPO SGPO Maintenance MGR 729-7677 / 434-0824 / 16-057 (I) Incident Commander OPS Clerks 729-2302 (TRN) Training Cooling Towers 614-6297 / 434-0830 (J) JITT

(#) Fire Cage Responder ER1-ER9 Assume Emergency Responder Positions (s) Not Emergency Responder Qualified ER9 NRC Phone Communicator

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine the required action for rod pull (calculate period)

JPM NUMBER:

675 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-000NO-03 Perform Reactor Startup K/A RATINGS:

RO 4.3 SRO 4.6 K/A STATEMENT:

2.1.37 Knowledge of procedures, guidelines, or limitations associated with reactivity management.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 675.

RO DATE: _______

TASK STANDARD: Calculates reactor period to be 55 seconds and list the steps for inserting the notched control rod until reactor period is greater than 60 seconds.

PRA: NA REFERENCES/PROCEDURES NEEDED: GOI-100-1A, Unit Startup and Power Operation VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: You are a Reactor Operator performing a startup in accordance with GOI-100-1A Unit Startup and Power Operation, where initial IRM readings are as follows:

A. 25/125 on range 3 B. 27/125 on range 3 INITIATING CUES: A control rod is withdrawn one notch and 38 seconds later the IRMs are reading the following:

A. 50/125 on range 3 B. 54/125 on range 3 What action(s) is/are required?

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: Applicant calculates reactor period given the initial and final IRM readings.

Standard:

Period of 55 seconds + 3 seconds is determined.

Doubling Time x 1.445 = period 38 seconds x 1.445 = 54.9 seconds Critical Step

___SAT

___UNSAT

___N/A Step 2: Applicant determines required actions in accordance with GOI-100-1A, Unit Startup and Power Operation.

Standard:

Determines that the rod just pulled is required to be inserted until a stable period of greater than 60 seconds is observed.

Also that Reactor Engineer, Reactivity Manager, and Shift Managers permission is obtained prior to subsequent control rod withdrawal.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant INITIAL CONDITIONS: You are a Reactor Operator performing a startup in accordance with GOI-100-1A Unit Startup and Power Operation, where initial IRM readings are as follows:

A. 25/125 on range 3 B. 27/125 on range 3 INITIATING CUES: A control rod is withdrawn one notch and 38 seconds later the IRMs are reading the following:

A. 50/125 on range 3 B. 54/125 on range 3 What action(s) is/are required? Provide answer below

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Determine Fuel Handling fuel storage compliance JPM NUMBER:

677 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-NO-105; Receipt of New Fuel K/A RATINGS:

RO 2.2 SRO 3.9 K/A STATEMENT:

2.1.35;Knowledge of the fuel-handling responsibilities of SROs.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Conduct of Operations EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 677.

SRO DATE: _______

TASK STANDARD: Using 0-GOI-100-2 and a set of conditions for new fuel stored on the refueling floor, determines that some of the bundles are not in compliance with the GOI.

PRA: NA REFERENCES/PROCEDURES NEEDED:

0-GOI-100-2 VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Classroom INITIAL CONDITIONS: You are an SRO directing new fuel inspections for Unit 1. You find the following:

1. Two un-irradiated nuclear fuel bundles are in the fuel handling area.
2. Three un-irradiated nuclear fuel bundles are in the new fuel storage vault.
3. Four full Inner Shipping Containers (ISCs) are stacked within a couple of feet to the Equipment Hatch.
4. Two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

INITIATING CUES:

Determine compliance with Fuel Handling Procedures for Un-irradiated fuel being unloaded on the refuel floor.

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the two un-irradiated nuclear fuel bundles are in the fuel handling area.

Standard:

Determines that it is acceptable to have two un-irradiated nuclear fuel bundles are in the fuel handling area.

___SAT

___UNSAT

___N/A Step 2: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the three un-irradiated nuclear fuel bundles are in the new fuel storage vault.

Standard:

Determines that it is NOT acceptable to have three un-irradiated nuclear fuel bundles are in the new fuel storage vault. Reference 0-GOI-100-2 Step 3.7 H Critical Step

___SAT

___UNSAT

___N/A Step 3: Using GOI-100-2 and NPG-SPP-8.1 the applicant assesses the four full Inner Shipping Containers (ISCs) that are stacked within a couple of feet to the Equipment Hatch.

Standard:

Determines that it is NOT acceptable to have Four full Inner Shipping Containers (ISCs) that are stacked within a couple of feet to the Equipment Hatch. Reference 0-GOI-100-2 Step 3.2 B Critical Step

___SAT

___UNSAT

___N/A Step 4: Applicant assesses the two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools Standard:

Determines that it is acceptable to have two full Inner Shipping Containers (ISCs) lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant Classroom INITIAL CONDITIONS: You are an SRO directing new fuel inspections for Unit 1.

1. Two un-irradiated nuclear fuel bundles are in the fuel handling area.
2. Three un-irradiated nuclear fuel bundles are in the new fuel storage vault.
3. Four full Inner Shipping Containers (ISCs) are stacked within a couple of feet to the Equipment Hatch.
4. Two full Inner Shipping Containers (ISCs) are lying side by side between the Unit 1 and Unit 2 Spent Fuel Pools.

INITIATING CUES:

Determine compliance with Fuel Handling Procedures for Un-irradiated fuel being unloaded on the refuel floor.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Perform Jet Pump Mismatch and Operability SR (RO)

JPM NUMBER:

680 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): U-068-SU-05; Perform Jet Pump Mismatch and Operability K/A RATINGS:

RO 3.7 SRO 4.1 K/A STATEMENT:

2.2.12; Knowledge of surveillance procedures.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Equipment Control EC EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 680.

RO DATE: _______

TASK STANDARD:

PRA: NA REFERENCES/PROCEDURES NEEDED: 2-SR-3.4.2.1 Jet Pump Mismatch and Operability VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 Operator.

CALC002 = 3456 CMWT 2-XR-68-50 Green Pen = 17 2-XR-68-50 Red Pen =

97 Recirc Motor Speeds 2A 2-SI-96-61 = 1456 2B 2-SI-96-73 = 1455 Recirc Pump Discharge Flows 2-FI-68-5 = 45 2-FI-68-81 = 44 (Continued)

Job Performance Measure (JPM) 4 INITIATING CUES: Perform 2-SR-3.4.2.1; Jet Pump Mismatch and Operability starting at step 7.2.1, using the provided readings.

Job Performance Measure (JPM) 5 START TIME STEP / STANDARD SAT /

UNSAT Step 1: 7.2.1 Core Power and Flow Readings

[1] RECORD the Core Thermal Power from Core Power and Flow Log. (N/A if ICS is NOT available) Point CALC002 _________CMWT Standard:

Records 3456 CMWT Critical Step

___SAT

___UNSAT

___N/A Step 2:

[2] RECORD the Core Plate Differential Pressure from ICS point 68-52 or 2-XR-68-50 (Green Pen). (N/A if not available)

Core Press Drop 68-52 __________PSID Standard:

Records 17 PSID Critical Step

___SAT

___UNSAT

___N/A Step 3:

[3] RECORD the Total Core Flow. Total Core Flow (Red Pen) 2-XR-68-50

________ Mlb/hr Standard:

Records 97 Mlb/hr Critical Step

___SAT

___UNSAT

___N/A Step : 7.2.2 Recirculation Pump Loops

[1] RECORD the Recirc Pump 2A and 2B Mtr Speeds for operating Recirc Pumps and MARK instrumentation used.

Pump Motor 2A Pump Motor 2B 2-SI-68-59 2-SI-68-71 2-SIT-068-0059 2-SIT-068-0071 2-SI-96-61 2-SI-96-73

________ RPM ________ RPM Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 6 STEP / STANDARD SAT /

UNSAT Standard:

Records the following.

Pump Motor 2A Pump Motor 2B 2-SI-68-59 2-SI-68-71 2-SIT-068-0059 2-SIT-068-0071 2-SI-96-61 2-SI-96-73

_1456__ RPM __1455__ RPM Step :

[2] RECORD the Recirc Pump Discharge flows.

Loop 2A Loop 2B 2-FI-68-5 2-FI-68-81

________ gpm X 1000 ________ gpm X 1000 Standard:

Records the following.

Loop 2A Loop 2B 2-FI-68-5 2-FI-68-81

___45 _ gpm X 1000 ___44 _ gpm X 1000 Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 7 STEP / STANDARD SAT /

UNSAT Step :

[3] RECORD the Recirc Loop 2A and 2B Jet Pump Flow.

Loop 2A Loop 2B 2-FI-68-46 2-FI-68-48

________ Mlb/hr ________ Mlb/hr Standard:

Records the following.

Loop 2A Loop 2B 2-FI-68-46 2-FI-68-48

___50 _Mlb/hr _ 49 _Mlb/hr Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 8 STEP / STANDARD SAT /

UNSAT Step : 7.2.3 Jet Pump Loops

[1] RECORD the following Differential Pressure readings below:

Standard:

Critical Step

___SAT

___UNSAT

___N/A 11 11 11 11 17.5 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11

Job Performance Measure (JPM) 9 STEP / STANDARD SAT /

UNSAT Step : 7.3 Tech Spec 3.4.1.1 - Recirculation Loop Mismatch Verification With Both Recirculation Loops In Operation Checks

[1] CALCULATE percent of Rated Core Flow (%WT) using data obtained in Section 7.2.1[3] as follows.

(Step 7.2.1[3] ÷102.5) X 100 =

% Core Flow

(__________ ÷ 102.5) X 100 =

Standard:

Records the following (Step 7.2.1[3] ÷102.5) X 100 =

% Core Flow

( 97 Mlb/hr ÷ 102.5) X 100 = _94.63 %__

Critical Step

___SAT

___UNSAT

___N/A Step :

[2] CALCULATE the absolute value for Recirculation Loop Jet Pump Flow Mismatch using data obtained in Section 7.2.2[3] as follows.

2-FI-68-46 2-FI-68-48

=

Mismatch

_______ Mlb/hr -

_______ Mlb/hr = _______ Mlb/hr Standard:

Records the following 2-FI-68-46 2-FI-68-48

=

Mismatch

_50 _Mlb/hr -

_49 _ Mlb/hr = _1 _ Mlb/hr Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 10 STEP / STANDARD SAT /

UNSAT Step :

[3] IF %WT is < 70% as recorded in Step 7.3[1], THEN CHECK Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is < 10.25.12 Mlb/hr.

Standard:

Marks step N/A

___SAT

___UNSAT

___N/A Step :

[4] IF %WT is > 70% as recorded in Step 7.3[1], THEN CHECK Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is <5.12 Mlb/hr.

Standard:

CHECKS Recirculation Loop Jet Pump Flow Mismatch recorded in Step 7.3[2] is < 5.12 Mlb/hr. and initials the step Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.1 Loop 2A Recirculation Pump and Jet Pump Flow to Recirculation Pump Speed

[1] Using the 2A Pump Speed recorded in Step 7.2.2[1] and the 2A Pump Flow recorded in Step 7.2.2[2]:

CHECK the plot falls between the two bold lines on and RECORD below.

Plot falls between the bold lines Yes No Standard: CHECKS the plot falls between the two bold lines on Attachment 1 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 11 STEP / STANDARD SAT /

UNSAT Step :

[2] Using the 2A Pump Speed recorded in Step 7.2.2[1] and the 2A Jet Pump Flow in Step 7.2.2[3]: CHECK the plot falls between the two bold lines on and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 2 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.1[1] and 7.4.1[2] from above: DETERMINE if the Jet Pump Loop 2A criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2A criteria is satisfied Yes No Standard:

DETERMINES if the Jet Pump Loop 2A criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2A criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.2 Loop 2B Recirculation Pump and Jet Pump Flow to Recirculation Pump Speed

[1] Using the 2B Pump Speed recorded in Step 7.2.2[1] and 2B Pump Flow recorded in Step 7.2.2[2]:

CHECK the plot falls between the two bold lines on Attachment 3 and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 3 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 12 STEP / STANDARD SAT /

UNSAT Step :

[2] Using the 2B Pump Speed recorded in Step 7.2.2[1] and 2B Jet Pump Flow recorded in Step 7.2.2[3]:

CHECK the plot falls between the two bold lines on Attachment 4 and RECORD below.

Plot falls between the bold lines Yes No Standard:

CHECKS the plot falls between the two bold lines on Attachment 4 and RECORD below.

Plot falls between the bold lines Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.2[1] and 7.4.2[2] from above:

DETERMINE if the Jet Pump Loop 2B criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2B criteria is satisfied Yes No Standard:

DETERMINE if the Jet Pump Loop 2B criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Loop 2B criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

7.4.3 Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification:

[1] Using the individual 2A Jet Pump DPs recorded in Step 7.2.3[1]

CHECK each individual Jet Pump DP recorded fall between the two bold lines on for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2A Individual DPs are between the bold lines. Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 13 STEP / STANDARD SAT /

UNSAT Standard:

CHECKS each individual Jet Pump DP recorded fall between the two bold lines on Attachment 5 for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2A Individual DPs are between the bold lines. Yes No Step :

[2] Using the individual 2B Jet Pump DPs recorded in Step 7.2.3[1]

CHECK each individual Jet Pump DP recorded fall between the two bold lines on for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2B Individual DPs are between the bold lines. Yes No Standard:

CHECKS each individual Jet Pump DP recorded fall between the two bold lines on Attachment 6 for the recorded Total Flow in Step 7.2.1[3] and RECORD results below.

2B Individual DPs are between the bold lines. Yes No Critical Step

___SAT

___UNSAT

___N/A Step :

[3] Using Steps 7.4.3[1] and 7.4.3[2]

DETERMINE whether the Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied Yes No Standard:

DETERMINES whether the Recirculation Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied by marking below if both steps are marked as Yes.

Jet Pump Diffuser to Lower Plenum Differential Pressure Verification criteria is satisfied Yes No Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 14 STEP / STANDARD SAT /

UNSAT Step : 7.4.4 Engineering Judgment/Review Criteria

[1] IF any of the following conditions apply:

  • Following Refueling Outage. (See Caution above)

OR

  • The Reactor is in Single Loop Operation (See Caution above)

OR

  • If point(s) plotted in Sections 7.4.1 or 7.4.2, AND 7.4.3 fall on or outside the bolded lines, to determine if the graph(s) need updating, THEN PERFORM Attachment 7, Engineering Judgment/Review:

(Otherwise N/A this step and Mark all of Attachment 7 as N/A)

Standard:

Evaluates step and determines that this step is N/A

___SAT

___UNSAT

___N/A Step :

7.4.5 Operability Determination

[1] MARK the appropriate criteria results for the following. (N/A any criteria not performed)

Steps Criteria Results Yes No N/A 7.4.1[3] and 7.4.2[3]

Both Jet Pump Loops steps are marked as YES 7.4.3[3]

Jet Pump DP to criteria is marked as YES.

Engineering Evaluation is marked as YES.

Standard:

MARKS the appropriate criteria results for the following. (N/A any criteria not performed)

Steps Criteria Results Yes No N/A 7.4.1[3] and 7.4.2[3]

Both Jet Pump Loops steps are marked as YES 7.4.3[3]

Jet Pump DP to criteria is marked as YES.

Engineering Evaluation is marked as YES.

Critical Step

___SAT

___UNSAT

___N/A

Job Performance Measure (JPM) 15 STEP / STANDARD SAT /

UNSAT Step :

7.5 Completion and Notifications

[1] IF an Engineering Judgment/Review was performed, THEN ENSURE the Engineering Judgment/Review documentation is attached to this SR. (Otherwise N/A) ________

Standard:

Determines this step is N/A

___SAT

___UNSAT

___N/A Step :

[2] On the Surveillance Task Sheet (STS)

[2.1] RECORD the Completion Date & Time. ________

[2.2] REVIEW and COMPLETE through the Test Director/Lead Performer & Date fields. ________

Standard:

[2] On the Surveillance Task Sheet (STS)

[2.1] RECORDS the Completion Date & Time. ________

[2.2] REVIEWS and COMPLETES through the Test Director/Lead Performer &

Date fields. ________

___SAT

___UNSAT

___N/A Step :

[3] NOTIFY the Unit Supervisor that this test is complete.

Standard:

NOTIFIES the Unit Supervisor that this test is complete.

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 16 Provide to Applicant INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 Operator.

CALC002 = 3456 CMWT 2-XR-68-50 Green Pen = 17 2-XR-68-50 Red Pen =

97 Recirc Motor Speeds 2A 2-SI-96-61 = 1456 2B 2-SI-96-73 = 1455 Recirc Pump Discharge Flows 2-FI-68-5 = 45 2-FI-68-81 = 44

Job Performance Measure (JPM) 17 (Continued)

INITIATING CUES: Perform 2-SR-3.4.2.1; Jet Pump Mismatch and Operability starting at step 7.2.1, using the provided readings.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE:

Review Completed SR (SRO)

JPM NUMBER:

676 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-AD-27, Assess LCO/TRM Actions to determine operability K/A RATINGS:

RO SRO 4.7 K/A STATEMENT:

2.2.22; Knowledge of limiting conditions for operations and safety limits RELATED PRA INFORMATION: N/A SAFETY FUNCTION:

Admin - Equipment Control EC EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number 676 A.

SRO DATE: _______

TASK STANDARD: Determines that the SR for the Jet Pump Operability has not been filled out correctly and that Jet Pump 15 is actually inoperable. And enters LCO 3.4.2 Jet Pumps Condition A, Required Action A.1 Be in mode 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

PRA: NA REFERENCES/PROCEDURES NEEDED: Completed 2-SR-3.4.2.1 Jet Pump Mismatch

& Operability, with Jet pump 15 inop, but not identified by the Unit Operator.

VALIDATION TIME: 15 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 INITIAL CONDITIONS: Unit 2 is operating at 100% power. You are the Unit 2 US and the UO has just completed the Jet Pump SR and it is ready to review.

INITIATING CUES: As the Unit Supervisor review the attached completed 2-SR-3.4.2.1.

Job Performance Measure (JPM) 4 START TIME STEP / STANDARD SAT /

UNSAT Step 1: US checks that the Unit Operator has checked and initialed each step.

Standard:

US notes that all initials are present and all calculations are completed.

___SAT

___UNSAT

___N/A Step 2: US checks that the UO has identified any anomalies.

Standard:

US notes that the UO incorrectly identified that Jet Pump 15 was within the graph curves however it fell outside the curves.

Critical Step

___SAT

___UNSAT

___N/A Step 3: US declares Jet Pump Inoperable.

Standard:

US reviews Tech Spec 3.4.2.1 and Bases and declares Jet Pump 15 Inoperable.

Critical Step

___SAT

___UNSAT

___N/A STOP TIME END OF TASK

Job Performance Measure (JPM) 5 Provide to Applicant INITIAL CONDITIONS: Unit 1 is operating at 100% power. You are the Unit 1 US and the UO has just completed the Jet Pump SR and it is ready to review.

INITIATING CUES: As the Unit Supervisor review the attached completed 1-SR-3.4.2.1.

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Upgrade PAR on wind shift.

JPM NUMBER:

679 REVISION: 0 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): S-000-EM Classify and Declare an Abnormal /

Emergency Event K/A RATINGS:

RO: SRO: 4.4 K/A No. &STATEMENT: 2.4.44; Knowledge of emergency plan protective action recommendations RELATED PRA INFORMATION: Risk Significant SAFETY FUNCTION:

EP EVALUATION LOCATION: In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number: _679___

SRO DATE: _______

TASK STANDARD: Addresses the change in conditions and performs Attachment H of EPIP-5 then with that assessment completed, updates the Protective Action Requirement of EPIP-5 Appendix F.

Operator Fundamental evaluated:

OF-1 Monitoring plant indications and conditions closely.

PRA: NA REFERENCES/PROCEDURES NEEDED:

EPIP - 5 partially filled out.

VALIDATIONTIME:

PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

IF UNSAT results are obtained THEN Retain entire JPM for records. (Otherwise just retain this page.)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Revision Summary Rev No.

Effective Date Pages Affected Description 0

08-4-15 All Initial issue

Job Performance Measure (JPM) 4 CLASSROOM INITIAL CONDITIONS: You are the Shift Manager during a General Emergency Classification for Unit 1 and the attached EPIP-5 Appendix A was filled out 45 minutes ago. The TSC is not operational yet.

Conditions at the current time are as follows:

Unit1: Parameters consistent with 2.1-G.

Onsite Protective Actions Assembly and Accountability are completed.

Unit 2: At Power Unit 3: At Power Meteorological Wind speed 20 mph gusting to 30 mph Wind direction 280º INITIATING CUES: Assess the new information and perform the required actions using the attached EPIP-5.

Job Performance Measure (JPM) 5

Job Performance Measure (JPM) 6 KEY

Job Performance Measure (JPM) 7 KEY

Job Performance Measure (JPM) 8 START TIME:

STEP / STANDARD SAT / UNSAT Step 1:

The applicant reviews the new information provided.

Standard:

The applicant notes that the only significant change is Wind direction.

SAT UNSAT N/A Step 2:

EPIP-5 3.6 Monitor / Re-evaluate the Event Appendix E

[1] IF significant changes in plant conditions occur, THEN DIRECT a member of the Operations staff (SRO if available) to complete Appendix F General Emergency Follow-Up Information Form, otherwise Continue in this Appendix at Step 2.0.

Standard:

The applicant identifies that Appendix F is needed.

Critical Step SAT UNSAT N/A Step 3:

EPIP-5 Appendix H PAR Flowchart is used to determine that the PAR essentially stays the same and proceeds to fill out Appendix F Standard:

Appendix H PAR Flowchart is marked similarly to the KEY provided.

SAT UNSAT N/A

Job Performance Measure (JPM) 9 STEP / STANDARD SAT / UNSAT Step 2:

EPIP-5 3.6 Monitor / Re-evaluate the Event Appendix F is used to communicate Follow-Up information. Continue to conduct State Follow-Ups until the CECC has assumed State Communications responsibilities.

Standard:

The applicant fills out EPIP-5 Appendix F to match the KEY Provided.

Critical Step SAT UNSAT N/A Termination Criteria: When the candidate has completed filling out Appendix F, the JPM can end.

STOP TIME:

Job Performance Measure (JPM) 10 Provide to Applicant CLASSROOM INITIAL CONDITIONS: You are the Shift Manager during a General Emergency Classification for Unit 1 and the attached EPIP-5 Appendix A was filled out 45 minutes ago. The TSC is not operational yet.

Conditions at the current time are as follows:

Unit1: Parameters consistent with 2.1-G.

Onsite Protective Actions Assembly and Accountability are completed.

Unit 2: At Power Unit 3: At Power Meteorological Wind speed 20 mph gusting to 30 mph Wind direction 280º INITIATING CUES: Assess the new information and perform the required actions using the attached EPIP-5

Job Performance Measure (JPM) 11 Provide to Applicant

Job Performance Measure (JPM) 12 Provide to Applicant within 15 minutes

Job Performance Measure (JPM) 1 SITE:

BFN JPM TITLE: Review a Radiological Survey Map JPM NUMBER:

544 REVISION: 3 TASK APPLICABILITY:

SRO STA UO NAUO TASK NUMBER / TASK TITLE(S): A-000-AD-35 / Use a Radiation Work Permit K/A RATINGS:

K/A RATING: RO 3.5 SRO 3.6 K/A STATEMENT:

2.3.7 Ability to comply with radiation work permit requirements during normal or abnormal conditions.

RELATED PRA INFORMATION: N/A SAFETY FUNCTION: RAD CONTROL EVALUATION LOCATION:

In-Plant Simulator Control Room Lab Other - List Classroom APPLICABLE METHOD OF TESTING: Discussion Simulate/Walkthrough Perform TIME FOR COMPLETION: N/A TIME CRITICAL (Y/N) ALTERNATE PATH (Y/N)

Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1)

(See JPM Validation Checklist in NPG-SPP-17.8.2)

Validated by:

Approved by:

Validator Date Approved by:

Site Training Management Date Site Training Program Owner Date N

N

Job Performance Measure (JPM) 2 OPERATOR: ________________________________

JPM Number __544___

RO SRO DATE: _______

TASK STANDARD: Review a Radiological Survey Map to determine if a task can be completed without exceeding exposure limits PRA: NA REFERENCES/PROCEDURES NEEDED:

None VALIDATION TIME: 10 Minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____ (Retain entire JPM for records)

SIGNATURE: ___________________________ DATE: __________

EXAMINER

Job Performance Measure (JPM) 3 Classroom INITIAL CONDITIONS:

You are a Browns Ferry employee who has obtained a cumulative yearly dose of 500 mrem.

The job will require you to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. To manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 15 minutes to install the mechanical restraining device.

The map of the room has radiological survey information you must interpret to successfully complete this JPM.

Assume that any transit time has NO dose.

INITIATING CUE:

Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding and RWP or TVA limits.

Job Performance Measure (JPM) 4 EXAMINER KEY ANSWER:

10 min to close valve + 15 min to install device = 25 min 25/60 = 0.417 hrs 0.417 hrs x 300 mr/hr = 125 mrem to close valve & install device (Between 122.0 to 127.0) (Critical) 125 + 500 = 625 (Yes - within both TVA annual limit of 1Rem and RWP Dose and Dose Rate limits, work areas at 30cm dose rate 300 mrem < 500 mrem rate alarm) (Critical)

Job Performance Measure (JPM) 5 Provide to Applicant Classroom INITIAL CONDITIONS:

You are a Browns Ferry employee who has obtained a cumulative yearly dose of 500 mrem.

The job will require you to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. To manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 15 minutes to install the mechanical restraining device.

The map of the room has radiological survey information you must interpret to successfully complete this JPM.

Assume that any transit time has NO dose.

INITIATING CUE:

Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding and RWP or TVA limits.

Job Performance Measure (JPM) 6 Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY GENERAL DESCRIPTION Status: Active Start Date: 01-Jan-This year End Date: 01-Jan-Next year Type: SPECIFIC MAP ID: Outage: Y Name:

Task: ROUTINE PLANT MAINTENANCE PSE: N HP CONTINUOUS Authorization Type: INDIVIDUAL ALARA Review Number: 0A-0010 Primary Work Doc:

Person-mrem Estimate: 1904 Person-Hrs Estimate: 1082 Dose Alarm: 300 Dose Rate Alarm: 500 DAC-Hrs Tracked: N Work Area

Description:

Unit 3 Areas All Elevations DESCRIPTION OF WORK TO BE PERFORMED Unit 3 Maintenance on RWCU (69) Systems (LHRA VARIOUS DRESS) 200 / 250 / 500 ANTI-CONTAMINATION CLOTHING REQUIREMENTS 1 LAB COAT 1,2 BOOTIES, CLOTH, ONE PAIR 1,2 GLOVES, RUBBER, ONE PAIR 1,2,3 CLOTH INSERTS 1,2,3 SHOE COVERS, ONE PAIR 1,2,3 MODESTY CLOTHING 1,2,3 NO PERSONAL OUTER CLOTHING 1,2,3 SURGEON'S CAP 2,3 COVERALLS, ONE PAIR 3 BOOTIES, PLASTIC, TWO PAIR 3 FACE SHIELD 3 RAIN SUIT 3 GLOVES, RUBBER, TWO PAIR 3,4 HOOD DOSIMETRY REQUIREMENTS ELECTRONIC DOSIMETER TLD BRIEFING REQUIREMENTS PRE-JOB BRIEFING EQUIS WORK STEPS 1 MANAGEMENT / WO WALKDOWN 2 3-CI-412 3 OPS VALVE LINEUP OI-69 & HX VENTING 4 07-712928-000 5 06-722560-000

Job Performance Measure (JPM) 7 Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY WORKER INSTRUCTIONS 1 DRESSOUT CODE APPLICATIONS

1) FLOOR LEVEL INSP, LOW TO MODERATE CONTAMINATION.
2) MINOR MAINTENANCE, NO PRIMARY SYSTEM BREACH.
3) PRIMARY SYSTEM BREACH, HEAT EXCHANGER VENTING.
4) ANY WORK ABOVE FLOOR LEVEL REQUIRES SAFETY BELT W/ LIFELINE.
5) REQUIRED TO WEAR HEADGEAR OTHER THAN PERSONAL HARDHAT.

2 MONITOR YOUR ED (DAD) FREQUENTLY, EXIT THE AREA PRIOR TO REACHING THE DOSE ALARM SET POINT OR UPON RECEIVING ANY UNEXPECTED ALARMS.

3 DO NOT EXCEED 250 mrem PER ENTRY OR DOSE MARGIN (RAD-REMAINING ALLOWABLE DOSE).

4 REMOTE MONITORING, PEA, OR SIMILAR DEVICE REQUIRED.

5 ED (DAD) TO BE BAGGED (WRAPPED) AND WORN OUTSIDE OF C-ZONE CLOTHING.

6 REVIEW PLANNED WORK OR INSPECTIONS WITH RAD PROTECTION PRIOR TO ENTRY.

7 UTILIZE TIME, DISTANCE, AND SHIELDING ALARA PRINCIPLES.

8 REVIEW APPROPRIATE SURVEY DATA PRIOR TO ENTRY. NOTE AND AVOID POSTED HOT SPOTS. LOCATE AND UTILIZE LOW DOSE WAITING AREAS.

9 RADWORKER SHALL ADHERE TO ANY SPECIAL INSTRUCTIONS (APR, ETC) ON WHICH HE/SHE HAS BEEN BRIEFED BY RAD PROTECTION.

10 NOTIFY RADCON PRIOR TO ANY SYSTEM BREACH.

11 RAD PROTECTION COVERAGE MAY BE PROVIDED FROM OUTSIDE THE C-ZONE.

12 SECURE ALL HOSES, ELECTRICAL CORDS, WELDING LEADS AND OTHER SERVICES ENTERING THE C-ZONE AT THE C-ZONE BOUNDRY AND NOTIFY RAD PROTECTION.

13 NOTIFY RAD PROTECTION OF ANY UNUSUAL RADIOLOGICAL CONDITIONS (FOR EXAMPLE:

WATER, LEAKS, RADIATION MONITOR ALARMS).

14 RAD PROTECTION PERMISSION REQUIRED PRIOR TO WELDING, GRINDING, BUFFING OR OTHER SURFACE DISTURBING ACTIVITIES.

APPROVAL Prepaired by: TJFRANK Approved by: MJHAZEL Final Approval: JWSMITH3 End of RWP

Job Performance Measure (JPM) 8 Provide to Applicant DR 11

  • 600

+300 45 Date/Time: Today 1 Hr ago DR 8

  • 1200

+500 320